@article{GronsfeldJoachimMalecha2019, author = {Gronsfeld, Richard and Joachim, Klubert and Malecha, Hartmut}, title = {3-D-Visualisierung von vorhandenen Staubauwerken zur holistischen Planung und {\"U}berwachung}, series = {Wasserwirtschaft}, volume = {109}, journal = {Wasserwirtschaft}, number = {5}, publisher = {Springer}, address = {Berlin}, issn = {2192-8762}, doi = {10.1007/s35147-019-0075-x}, pages = {82 -- 85}, year = {2019}, language = {de} } @article{KuhnhenneRegerPyschnyetal.2020, author = {Kuhnhenne, Markus and Reger, Vitali and Pyschny, Dominik and D{\"o}ring, Bernd}, title = {Influence of airtightness of steel sandwich panel joints on heat losses}, series = {E3S Web of Conferences 12th Nordic Symposium on Building Physics (NSB 2020)}, volume = {172}, journal = {E3S Web of Conferences 12th Nordic Symposium on Building Physics (NSB 2020)}, number = {Art. 05008}, publisher = {EDP Sciences}, address = {Les Ulis}, doi = {10.1051/e3sconf/202017205008}, pages = {6}, year = {2020}, abstract = {Energy saving ordinances requires that buildings must be designed in such a way that the heat transfer surface including the joints is permanently air impermeable. The prefabricated roof and wall panels in lightweight steel constructions are airtight in the area of the steel covering layers. The sealing of the panel joints contributes to fulfil the comprehensive requirements for an airtight building envelope. To improve the airtightness of steel sandwich panels, additional sealing tapes can be installed in the panel joint. The influence of these sealing tapes was evaluated by measurements carried out by the RWTH Aachen University - Sustainable Metal Building Envelopes. Different installation situations were evaluated by carrying out airtightness tests for different joint distances. In addition, the influence on the heat transfer coefficient was also evaluated using the Finite Element Method (FEM). The combination of obtained air volume flow and transmission losses enables to create an "effective heat transfer coefficient" due to transmission and infiltration. This summarizes both effects in one value and is particularly helpful for approximate calculations on energy efficiency.}, language = {en} } @article{RegerDoeringKuhnhenne2016, author = {Reger, V. and D{\"o}ring, Bernd and Kuhnhenne, M.}, title = {Passive und aktive Maßnahmen zur Fl{\"a}chenk{\"u}hlung im Stahl(leicht)bau}, series = {Bauingenieur}, volume = {91}, journal = {Bauingenieur}, number = {Jul/Aug}, publisher = {VDI Fachmedien}, address = {D{\"u}sseldorf}, issn = {0005-6650}, doi = {10.37544/0005-6650-2016-07-08-63}, pages = {309 -- 316}, year = {2016}, abstract = {Mit steigenden D{\"a}mmstandards und h{\"o}heren Komfortanforderungen der Nutzer ger{\"a}t die Problematik der sommerlichen {\"U}berhitzung zunehmend in den Fokus. Um die {\"U}berhitzung m{\"o}glichst gering zu halten, sind Maßnahmen und L{\"o}sungen zu entwickeln, die den potenziellen K{\"u}hlbedarf eines Geb{\"a}udes vermeiden sowie reduzieren. Im Rahmen des europ{\"a}ischen Forschungsprojektes BATIMASS wurden Techniken untersucht, die die sommerliche Raumtemperatur ohne zus{\"a}tzliche K{\"u}hlung (passiv) oder aber mit energieeffizienter wasserbasierter Fl{\"a}chenk{\"u}hlung (aktiv) reduzieren und die besonders f{\"u}r Geb{\"a}ude in Stahl(leicht)bauweise geeignet sind. Daf{\"u}r wurde die Methodik der thermisch {\"a}quivalenten Decke weiterentwickelt, um das thermische Verhalten von Profilblechdecken in Geb{\"a}uden f{\"u}r beide L{\"o}sungsans{\"a}tze analysieren zu k{\"o}nnen. Dar{\"u}ber hinaus wurde der Einsatz von Phasenwechselmaterial (PCM) zur Steigerung der Speicherf{\"a}higkeit von leichten Decken mit besonders geringer thermischer Masse in Simulationen sowie im Labor untersucht und bewertet.}, language = {de} } @article{PyschnyDoeringFeldmann2014, author = {Pyschny, D. and D{\"o}ring, Bernd and Feldmann, M.}, title = {Ermittlung der thermischen Leistungsf{\"a}higkeit des neuartigen multifunktionalen Verbunddeckensystems InaDeck}, series = {Bauingenieur : die richtungsweisende Zeitschrift im Bauingenieurswesen}, volume = {89}, journal = {Bauingenieur : die richtungsweisende Zeitschrift im Bauingenieurswesen}, number = {3}, publisher = {VDI Fachmedien}, address = {D{\"u}sseldorf}, issn = {0005-6650}, pages = {116 -- 124}, year = {2014}, language = {de} } @article{HennesLaumann2021, author = {Hennes, Philipp and Laumann, J{\"o}rg}, title = {Ansatz der Drehbehinderung aus Koppelpfetten mit d{\"u}nnwandigen kaltgeformten Z-Profilen}, series = {Stahlbau}, volume = {90}, journal = {Stahlbau}, number = {3}, publisher = {Ernst \& Sohn}, address = {Berlin}, issn = {1437-1049}, doi = {10.1002/stab.202000104}, pages = {158 -- 168}, year = {2021}, language = {de} } @article{GrossTimmer1998, author = {Groß, Rolf Fritz and Timmer, H.}, title = {Energetische und betriebswirtschaftliche Bewertung von K{\"u}hlsystemen f{\"u}r K{\"u}hllager}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {49}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {9}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {74 -- 77}, year = {1998}, language = {de} } @article{ThulfautGross2000, author = {Thulfaut, Christian and Groß, Rolf Fritz}, title = {Experimentelle Untersuchung der Luftstromvermischung in Hybridzellenk{\"u}hlt{\"u}rmen}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {51}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {8}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {48 -- 49}, year = {2000}, abstract = {Zwangsbel{\"u}ftete Nassk{\"u}hlt{\"u}rme haben im Gegensatz zur Trockenk{\"u}hlung bei naßkaltem Wetter Nebelschwaden zur Folge. Dagegen ist bei Naßk{\"u}hlung die spezifische K{\"u}hlleistung durch abgef{\"u}hrte Kondensationsw{\"a}rme h{\"o}her als bei der Trockenk{\"u}hlung. Hybridzellenk{\"u}hlt{\"u}rme kombinieren beide Methoden, so daß ein Mischstrom beider Abluftstr{\"o}me die Wasserdampf-S{\"a}ttigungsgrenze nicht {\"u}berschreitet. Durch das Mischungsverh{\"a}ltnis kann man den gew{\"u}nschten S{\"a}ttigungsgrad einstellen. Je dichter dieser an der S{\"a}ttigungsgrenze liegt, desto h{\"o}her ist die K{\"u}hlleistung. Der von unten zugef{\"u}hrte Luftstrom der Naßk{\"u}hlung und der seitlich zugef{\"u}hrte trockene Abluftstrom m{\"u}ssen sehr gut durchmischt werden, um {\"u}ber den gesamten Austrittsquerschnitt des K{\"u}hlturms die S{\"a}ttigungsgrenze nicht zu {\"u}berschreiten. In einem maßstabsgerechten Modell wurde der Mischungsgrad mit und ohne Einbauten untersucht. {\"U}ber ein Raster von 10 mal 10 Punkten wurde die {\"o}rtliche Temperaturverteilung ermittelt. W{\"a}rmebilanzen ergeben dann die Mischungsg{\"u}te in einer Ebene oberhalb der Zellenkrone. W{\"a}hrend ohne Mischeinbauten der Trockenluftanteil in der Mitte des Querschnitts bei unter 15 \% liegt erh{\"o}hen Einbauten den Trockenluftanteil auf 30 \% bis {\"u}ber 40 \%. Dabei wurde die Trockenluft auf jeder K{\"u}hlturmseite durch 4 konisch zulaufende, unten offene und oben geschlitzte Einbauten kanalisiert. Die Nassluft wurde durch eine im Querschnitt dreieckige Rinne in Richtung der Trockenluftausl{\"a}sse umgelenkt. Im Raster leicht zu lokalisierende Abweichungen vom gew{\"u}nschten Mittelwert zeigen Potential f{\"u}r die weitere Verbesserung der Einbauten.}, language = {de} } @article{GrossBerger2005, author = {Groß, Rolf Fritz and Berger, J.}, title = {Quo Vadis - Ausblick in die Geb{\"a}udeleittechnik der Zukunft}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {56}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {1}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {39 -- 41}, year = {2005}, abstract = {Auf dem Weg zum vernetzten Haus stoßen Hersteller und Planer, insbesondere im privaten Wohnungsbau, zur Zeit noch auf erhebliche Widerst{\"a}nde bei der Durchdringung des Marktes.}, language = {de} } @article{GrossBergerGross2003, author = {Groß, Rolf Fritz and Berger, J. and Groß, H.}, title = {Geb{\"a}udeautomation - Betriebsdatenerfassung und Geb{\"a}udeleittechnik im Klartext}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {54}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {2}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {81}, year = {2003}, language = {de} } @article{LepkeLilliePetersonetal.2006, author = {Lepke, Dietrich and Lillie, Dirk and Peterson, Leif Arne and Hempe, Thomas}, title = {Liegedauer von Holzschwellen in Tunneln der Hamburger Hochbahn AG}, series = {EI - Der Eisenbahningenieur}, journal = {EI - Der Eisenbahningenieur}, number = {2}, publisher = {DVV Media Group}, address = {Hamburg}, issn = {0013-2810}, pages = {46 -- 50}, year = {2006}, abstract = {Die Hamburger Hochbahn AG ben{\"o}tigte im Rahmen der {\"U}berarbeitung einer langfristigen Instandhaltungs- und Erneuerungsstrategie f{\"u}r ihre U-Bahn-Infrastruktur eine belastbare Aussage {\"u}ber die Restlebensdauer der Holzschwellen im Tunnel. Aus diesem Grunde beauftragte sie das Institut f{\"u}r Verkehrswesen, Eisenbahnbau und -betrieb (IVE) der Universit{\"a}t Hannover mit der Erstellung eines entsprechenden Gutachtens. Das Ergebnis f{\"u}hrte zu der gesicherten Aussage einer erheblich l{\"a}ngeren Restlebensdauer der Tunnelschwellen gegen{\"u}ber den bisherigen, gesch{\"a}tzten Annahmen.}, language = {de} }