@article{ElMoussaouiTalbiAtmaneetal.2020, author = {El Moussaoui, Noureddine and Talbi, Sofian and Atmane, Ilyas and Kassmi, Khalil and Schwarzer, Klemens and Chayeb, Hamid and Bachiri, Najib}, title = {Feasibility of a new design of a Parabolic Trough Solar Thermal Cooker (PSTC)}, series = {Solar Energy}, volume = {201}, journal = {Solar Energy}, number = {Vol. 201 (May 2020)}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0038-092X}, doi = {10.1016/j.solener.2020.03.079}, pages = {866 -- 871}, year = {2020}, abstract = {In this article, we describe the structure, the functioning, and the tests of parabolic trough solar thermal cooker (PSTC). This oven is designed to meet the needs of rural residents, including Urban, which requires stable cooking temperatures above 200 °C. The cooking by this cooker is based on the concentration of the sun's rays on a glass vacuum tube and heating of the oil circulate in a big tube, located inside the glass tube. Through two small tubes, associated with large tube, the heated oil, rise and heats the pot of cooking pot containing the food to be cooked (capacity of 5 kg). This cooker is designed in Germany and extensively tested in Morocco for use by the inhabitants who use wood from forests. During a sunny day, having a maximum solar radiation around 720 W/m2 and temperature ambient around 26 °C, maximum temperatures recorded of the small tube, the large tube and the center of the pot are respectively: 370 °C, 270 °C and 260 °C. The cooking process with food at high (fries, ..), we show that the cooking oil temperature rises to 200 °C, after 1 h of heating, the cooking is done at a temperature of 120 °C for 20 min. These temperatures are practically stable following variations and decreases in the intensity of irradiance during the day. The comparison of these results with those of the literature shows an improvement of 30-50 \% on the maximum value of the temperature with a heat storage that could reach 60 min of autonomy. All the results obtained show the good functioning of the PSTC and the feasibility of cooking food at high temperature (>200 °C).}, language = {en} } @article{DammSauerbornFendetal.2017, author = {Damm, Marc Andr{\´e} and Sauerborn, Markus and Fend, Thomas and Herrmann, Ulf}, title = {Optimisation of a urea selective catalytic reduction system with a coated ceramic mixing element}, series = {Journal of ceramic science and technology}, volume = {8}, journal = {Journal of ceramic science and technology}, number = {1}, publisher = {G{\"o}ller}, address = {Baden-Baden}, isbn = {2190-9385 (Print)}, issn = {2190-9385 (Online)}, doi = {10.4416/JCST2016-00056}, pages = {19 -- 24}, year = {2017}, language = {en} } @article{AlexopoulosHoffschmidt2017, author = {Alexopoulos, Spiros and Hoffschmidt, Bernhard}, title = {Advances in solar tower technology}, series = {Wiley interdisciplinary reviews : Energy and Environment : WIREs}, volume = {6}, journal = {Wiley interdisciplinary reviews : Energy and Environment : WIREs}, number = {1}, publisher = {Wiley}, address = {Weinheim}, issn = {2041-840X}, doi = {10.1002/wene.217}, pages = {1 -- 19}, year = {2017}, language = {en} } @article{GoettscheAlexopoulosDuemmleretal.2019, author = {G{\"o}ttsche, Joachim and Alexopoulos, Spiros and D{\"u}mmler, Andreas and Maddineni, S. K.}, title = {Multi-Mirror Array Calculations With Optical Error}, pages = {1 -- 6}, year = {2019}, abstract = {The optical performance of a 2-axis solar concentrator was simulated with the COMSOL Multiphysics® software. The concentrator consists of a mirror array, which was created using the application builder. The mirror facets are preconfigured to form a focal point. During tracking all mirrors are moved simultaneously in a coupled mode by 2 motors in two axes, in order to keep the system in focus with the moving sun. Optical errors on each reflecting surface were implemented in combination with the solar angular cone of ± 4.65 mrad. As a result, the intercept factor of solar radiation that is available to the receiver was calculated as a function of the transversal and longitudinal angles of incidence. In addition, the intensity distribution on the receiver plane was calculated as a function of the incidence angles.}, language = {en} } @article{GorzalkaSchmiedtSchorn2021, author = {Gorzalka, Philip and Schmiedt, Jacob Estevam and Schorn, Christian}, title = {Automated Generation of an Energy Simulation Model for an Existing Building from UAV Imagery}, series = {Buildings}, volume = {11}, journal = {Buildings}, number = {9}, publisher = {MDPI}, address = {Basel}, issn = {2075-5309}, doi = {10.3390/buildings11090380}, pages = {15 Seiten}, year = {2021}, abstract = {An approach to automatically generate a dynamic energy simulation model in Modelica for a single existing building is presented. It aims at collecting data about the status quo in the preparation of energy retrofits with low effort and costs. The proposed method starts from a polygon model of the outer building envelope obtained from photogrammetrically generated point clouds. The open-source tools TEASER and AixLib are used for data enrichment and model generation. A case study was conducted on a single-family house. The resulting model can accurately reproduce the internal air temperatures during synthetical heating up and cooling down. Modelled and measured whole building heat transfer coefficients (HTC) agree within a 12\% range. A sensitivity analysis emphasises the importance of accurate window characterisations and justifies the use of a very simplified interior geometry. Uncertainties arising from the use of archetype U-values are estimated by comparing different typologies, with best- and worst-case estimates showing differences in pre-retrofit heat demand of about ±20\% to the average; however, as the assumptions made are permitted by some national standards, the method is already close to practical applicability and opens up a path to quickly estimate possible financial and energy savings after refurbishment.}, language = {en} } @article{PeereBlanke2022, author = {Peere, Wouter and Blanke, Tobias}, title = {GHEtool: An open-source tool for borefield sizing in Python}, series = {Journal of Open Source Software}, volume = {7}, journal = {Journal of Open Source Software}, number = {76}, editor = {Vernon, Chris}, issn = {2475-9066}, doi = {10.21105/joss.04406}, pages = {1 -- 4, 4406}, year = {2022}, abstract = {GHEtool is a Python package that contains all the functionalities needed to deal with borefield design. It is developed for both researchers and practitioners. The core of this package is the automated sizing of borefield under different conditions. The sizing of a borefield is typically slow due to the high complexity of the mathematical background. Because this tool has a lot of precalculated data, GHEtool can size a borefield in the order of tenths of milliseconds. This sizing typically takes the order of minutes. Therefore, this tool is suited for being implemented in typical workflows where iterations are required. GHEtool also comes with a graphical user interface (GUI). This GUI is prebuilt as an exe-file because this provides access to all the functionalities without coding. A setup to install the GUI at the user-defined place is also implemented and available at: https://www.mech.kuleuven.be/en/tme/research/thermal_systems/tools/ghetool.}, language = {en} } @article{GrossTimmer1998, author = {Groß, Rolf Fritz and Timmer, H.}, title = {Energetische und betriebswirtschaftliche Bewertung von K{\"u}hlsystemen f{\"u}r K{\"u}hllager}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {49}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {9}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {74 -- 77}, year = {1998}, language = {de} } @article{ThulfautGross2000, author = {Thulfaut, Christian and Groß, Rolf Fritz}, title = {Experimentelle Untersuchung der Luftstromvermischung in Hybridzellenk{\"u}hlt{\"u}rmen}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {51}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {8}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {48 -- 49}, year = {2000}, abstract = {Zwangsbel{\"u}ftete Nassk{\"u}hlt{\"u}rme haben im Gegensatz zur Trockenk{\"u}hlung bei naßkaltem Wetter Nebelschwaden zur Folge. Dagegen ist bei Naßk{\"u}hlung die spezifische K{\"u}hlleistung durch abgef{\"u}hrte Kondensationsw{\"a}rme h{\"o}her als bei der Trockenk{\"u}hlung. Hybridzellenk{\"u}hlt{\"u}rme kombinieren beide Methoden, so daß ein Mischstrom beider Abluftstr{\"o}me die Wasserdampf-S{\"a}ttigungsgrenze nicht {\"u}berschreitet. Durch das Mischungsverh{\"a}ltnis kann man den gew{\"u}nschten S{\"a}ttigungsgrad einstellen. Je dichter dieser an der S{\"a}ttigungsgrenze liegt, desto h{\"o}her ist die K{\"u}hlleistung. Der von unten zugef{\"u}hrte Luftstrom der Naßk{\"u}hlung und der seitlich zugef{\"u}hrte trockene Abluftstrom m{\"u}ssen sehr gut durchmischt werden, um {\"u}ber den gesamten Austrittsquerschnitt des K{\"u}hlturms die S{\"a}ttigungsgrenze nicht zu {\"u}berschreiten. In einem maßstabsgerechten Modell wurde der Mischungsgrad mit und ohne Einbauten untersucht. {\"U}ber ein Raster von 10 mal 10 Punkten wurde die {\"o}rtliche Temperaturverteilung ermittelt. W{\"a}rmebilanzen ergeben dann die Mischungsg{\"u}te in einer Ebene oberhalb der Zellenkrone. W{\"a}hrend ohne Mischeinbauten der Trockenluftanteil in der Mitte des Querschnitts bei unter 15 \% liegt erh{\"o}hen Einbauten den Trockenluftanteil auf 30 \% bis {\"u}ber 40 \%. Dabei wurde die Trockenluft auf jeder K{\"u}hlturmseite durch 4 konisch zulaufende, unten offene und oben geschlitzte Einbauten kanalisiert. Die Nassluft wurde durch eine im Querschnitt dreieckige Rinne in Richtung der Trockenluftausl{\"a}sse umgelenkt. Im Raster leicht zu lokalisierende Abweichungen vom gew{\"u}nschten Mittelwert zeigen Potential f{\"u}r die weitere Verbesserung der Einbauten.}, language = {de} } @article{GrossBerger2005, author = {Groß, Rolf Fritz and Berger, J.}, title = {Quo Vadis - Ausblick in die Geb{\"a}udeleittechnik der Zukunft}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {56}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {1}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {39 -- 41}, year = {2005}, abstract = {Auf dem Weg zum vernetzten Haus stoßen Hersteller und Planer, insbesondere im privaten Wohnungsbau, zur Zeit noch auf erhebliche Widerst{\"a}nde bei der Durchdringung des Marktes.}, language = {de} } @article{GrossBergerGross2003, author = {Groß, Rolf Fritz and Berger, J. and Groß, H.}, title = {Geb{\"a}udeautomation - Betriebsdatenerfassung und Geb{\"a}udeleittechnik im Klartext}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {54}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {2}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {81}, year = {2003}, language = {de} }