@article{RichterBraunsteinStaeudleetal.2021, author = {Richter, Charlotte and Braunstein, Bjoern and St{\"a}udle, Benjamin and Attias, Julia and Suess, Alexander and Weber, Tobias and Mileva, Katja N. and Rittweger, Joern and Green, David A. and Albracht, Kirsten}, title = {Gastrocnemius medialis contractile behavior is preserved during 30\% body weight supported gait training}, series = {Frontiers in Sports and Active Living}, volume = {2021}, journal = {Frontiers in Sports and Active Living}, number = {2}, publisher = {Frontiers}, address = {Lausanne}, issn = {2624-9367}, doi = {10.3389/fspor.2020.614559}, pages = {Artikel 614559}, year = {2021}, abstract = {Rehabilitative body weight supported gait training aims at restoring walking function as a key element in activities of daily living. Studies demonstrated reductions in muscle and joint forces, while kinematic gait patterns appear to be preserved with up to 30\% weight support. However, the influence of body weight support on muscle architecture, with respect to fascicle and series elastic element behavior is unknown, despite this having potential clinical implications for gait retraining. Eight males (31.9 ± 4.7 years) walked at 75\% of the speed at which they typically transition to running, with 0\% and 30\% body weight support on a lower-body positive pressure treadmill. Gastrocnemius medialis fascicle lengths and pennation angles were measured via ultrasonography. Additionally, joint kinematics were analyzed to determine gastrocnemius medialis muscle-tendon unit lengths, consisting of the muscle's contractile and series elastic elements. Series elastic element length was assessed using a muscle-tendon unit model. Depending on whether data were normally distributed, a paired t-test or Wilcoxon signed rank test was performed to determine if body weight supported walking had any effects on joint kinematics and fascicle-series elastic element behavior. Walking with 30\% body weight support had no statistically significant effect on joint kinematics and peak series elastic element length. Furthermore, at the time when peak series elastic element length was achieved, and on average across the entire stance phase, muscle-tendon unit length, fascicle length, pennation angle, and fascicle velocity were unchanged with respect to body weight support. In accordance with unchanged gait kinematics, preservation of fascicle-series elastic element behavior was observed during walking with 30\% body weight support, which suggests transferability of gait patterns to subsequent unsupported walking.}, language = {en} } @article{RichterBraunsteinStaeudleetal.2021, author = {Richter, Charlotte and Braunstein, Bjoern and Staeudle, Benjamin and Attias, Julia and Suess, Alexander and Weber, Tobias and Mileva, Katya N. and Rittweger, Joern and Green, David A. and Albracht, Kirsten}, title = {Contractile behavior of the gastrocnemius medialis muscle during running in simulated hypogravity}, series = {npj Microgravity}, volume = {7}, journal = {npj Microgravity}, number = {Article number: 32}, publisher = {Springer Nature}, address = {New York}, issn = {2373-8065}, doi = {10.1038/s41526-021-00155-7}, pages = {7 Seiten}, year = {2021}, abstract = {Vigorous exercise countermeasures in microgravity can largely attenuate muscular degeneration, albeit the extent of applied loading is key for the extent of muscle wasting. Running on the International Space Station is usually performed with maximum loads of 70\% body weight (0.7 g). However, it has not been investigated how the reduced musculoskeletal loading affects muscle and series elastic element dynamics, and thereby force and power generation. Therefore, this study examined the effects of running on the vertical treadmill facility, a ground-based analog, at simulated 0.7 g on gastrocnemius medialis contractile behavior. The results reveal that fascicle-series elastic element behavior differs between simulated hypogravity and 1 g running. Whilst shorter peak series elastic element lengths at simulated 0.7 g appear to be the result of lower muscular and gravitational forces acting on it, increased fascicle lengths and decreased velocities could not be anticipated, but may inform the development of optimized running training in hypogravity. However, whether the alterations in contractile behavior precipitate musculoskeletal degeneration warrants further study.}, language = {en} } @article{PourshahidiAchtsnichtNambipareecheeetal.2021, author = {Pourshahidi, Ali Mohammad and Achtsnicht, Stefan and Nambipareechee, Mrinal Murali and Offenh{\"a}usser, Andreas and Krause, Hans-Joachim}, title = {Multiplex detection of magnetic beads using offset field dependent frequency mixing magnetic detection}, series = {Sensors}, volume = {21}, journal = {Sensors}, number = {17}, publisher = {MDPI}, address = {Basel}, issn = {1424-8220}, doi = {10.3390/s21175859}, pages = {16 Seiten}, year = {2021}, abstract = {Magnetic immunoassays employing Frequency Mixing Magnetic Detection (FMMD) have recently become increasingly popular for quantitative detection of various analytes. Simultaneous analysis of a sample for two or more targets is desirable in order to reduce the sample amount, save consumables, and save time. We show that different types of magnetic beads can be distinguished according to their frequency mixing response to a two-frequency magnetic excitation at different static magnetic offset fields. We recorded the offset field dependent FMMD response of two different particle types at frequencies ƒ₁ + n⋅ƒ₂, n = 1, 2, 3, 4 with ƒ₁ = 30.8 kHz and ƒ₂ = 63 Hz. Their signals were clearly distinguishable by the locations of the extremes and zeros of their responses. Binary mixtures of the two particle types were prepared with different mixing ratios. The mixture samples were analyzed by determining the best linear combination of the two pure constituents that best resembled the measured signals of the mixtures. Using a quadratic programming algorithm, the mixing ratios could be determined with an accuracy of greater than 14\%. If each particle type is functionalized with a different antibody, multiplex detection of two different analytes becomes feasible.}, language = {en} } @article{PoghossianWeldenBuniatyanetal.2021, author = {Poghossian, Arshak and Welden, Rene and Buniatyan, Vahe V. and Sch{\"o}ning, Michael Josef}, title = {An Array of On-Chip Integrated, Individually Addressable Capacitive Field-Effect Sensors with Control Gate: Design and Modelling}, series = {Sensors}, volume = {21}, journal = {Sensors}, number = {18}, publisher = {MDPI}, address = {Basel}, issn = {1424-8220}, doi = {10.3390/s21186161}, pages = {17}, year = {2021}, abstract = {The on-chip integration of multiple biochemical sensors based on field-effect electrolyte-insulator-semiconductor capacitors (EISCAP) is challenging due to technological difficulties in realization of electrically isolated EISCAPs on the same Si chip. In this work, we present a new simple design for an array of on-chip integrated, individually electrically addressable EISCAPs with an additional control gate (CG-EISCAP). The existence of the CG enables an addressable activation or deactivation of on-chip integrated individual CG-EISCAPs by simple electrical switching the CG of each sensor in various setups, and makes the new design capable for multianalyte detection without cross-talk effects between the sensors in the array. The new designed CG-EISCAP chip was modelled in so-called floating/short-circuited and floating/capacitively-coupled setups, and the corresponding electrical equivalent circuits were developed. In addition, the capacitance-voltage curves of the CG-EISCAP chip in different setups were simulated and compared with that of a single EISCAP sensor. Moreover, the sensitivity of the CG-EISCAP chip to surface potential changes induced by biochemical reactions was simulated and an impact of different parameters, such as gate voltage, insulator thickness and doping concentration in Si, on the sensitivity has been discussed.}, language = {en} } @article{PoghossianSchoening2021, author = {Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Recent progress in silicon-based biologically sensitive field-effect devices}, series = {Current Opinion in Electrochemistry}, journal = {Current Opinion in Electrochemistry}, number = {Article number: 100811}, publisher = {Elsevier}, address = {Amsterdam}, issn = {2451-9103}, doi = {10.1016/j.coelec.2021.100811}, year = {2021}, abstract = {Biologically sensitive field-effect devices (BioFEDs) advantageously combine the electronic field-effect functionality with the (bio)chemical receptor's recognition ability for (bio)chemical sensing. In this review, basic and widely applied device concepts of silicon-based BioFEDs (ion-sensitive field-effect transistor, silicon nanowire transistor, electrolyte-insulator-semiconductor capacitor, light-addressable potentiometric sensor) are presented and recent progress (from 2019 to early 2021) is discussed. One of the main advantages of BioFEDs is the label-free sensing principle enabling to detect a large variety of biomolecules and bioparticles by their intrinsic charge. The review encompasses applications of BioFEDs for the label-free electrical detection of clinically relevant protein biomarkers, deoxyribonucleic acid molecules and viruses, enzyme-substrate reactions as well as recording of the cell acidification rate (as an indicator of cellular metabolism) and the extracellular potential.}, language = {en} } @article{OliveiraMolinnusBegingetal.2021, author = {Oliveira, Danilo A. and Molinnus, Denise and Beging, Stefan and Siqueira Jr, Jos{\´e} R. and Sch{\"o}ning, Michael Josef}, title = {Biosensor Based on Self-Assembled Films of Graphene Oxide and Polyaniline Using a Field-Effect Device Platform}, series = {physica status solidi (a) applications and materials science}, volume = {218}, journal = {physica status solidi (a) applications and materials science}, number = {13}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.202000747}, pages = {1 -- 9}, year = {2021}, abstract = {A new functionalization method to modify capacitive electrolyte-insulator-semiconductor (EIS) structures with nanofilms is presented. Layers of polyallylamine hydrochloride (PAH) and graphene oxide (GO) with the compound polyaniline:poly(2-acrylamido-2-methyl-1-propanesulfonic acid) (PANI:PAAMPSA) are deposited onto a p-Si/SiO2 chip using the layer-by-layer technique (LbL). Two different enzymes (urease and penicillinase) are separately immobilized on top of a five-bilayer stack of the PAH:GO/PANI:PAAMPSA-modified EIS chip, forming a biosensor for detection of urea and penicillin, respectively. Electrochemical characterization is performed by constant capacitance (ConCap) measurements, and the film morphology is characterized by atomic force microscopy (AFM) and scanning electron microscopy (SEM). An increase in the average sensitivity of the modified biosensors (EIS-nanofilm-enzyme) of around 15\% is found in relation to sensors, only carrying the enzyme but without the nanofilm (EIS-enzyme). In this sense, the nanofilm acts as a stable bioreceptor onto the EIS chip improving the output signal in terms of sensitivity and stability.}, language = {en} } @article{Olbertz2021, author = {Olbertz, Klaus}, title = {Die Dienstreisezeit als Arbeitszeit - oder doch nicht? : Zur arbeitgeberfreundlichen Bewertung von Dienstreisezeiten durch das Bundesarbeitsgericht}, series = {NWB - Steuer- und Wirtschaftsrecht}, journal = {NWB - Steuer- und Wirtschaftsrecht}, number = {1}, issn = {0028-3460}, pages = {38 -- 44}, year = {2021}, abstract = {Der arbeitsrechtlich richtige Umgang mit Zeiten einer Dienstreise kann in der betrieblichen Praxis Probleme bereiten. Ob die Reisezeiten als solche Arbeitszeit i. S. des Arbeitszeitgesetzes (ArbZG ) darstellen, also bspw. auf die t{\"a}gliche H{\"o}chstarbeitszeit angerechnet werden m{\"u}ssen oder nicht, ist oftmals genauso unklar wie die Frage, ob und inwieweit Reisezeiten verg{\"u}tungspflichtig sind. Aber auch, ob ein Arbeitnehmer {\"u}berhaupt zur Durchf{\"u}hrung einer Dienstreise verpflichtet werden kann, ist ein m{\"o}glicher Anlass von Streitigkeiten zwischen den Arbeitsvertragsparteien, wie verschiedene Gerichtsentscheidungen zeigen. Der nachfolgende Beitrag beantwortet die aufgeworfenen Fragen und gibt hierzu einen praxisorientierten {\"U}berblick.}, language = {de} } @article{Olbertz2021, author = {Olbertz, Klaus}, title = {Wichtige arbeitsrechtliche Entwicklungen im Jahr 2020 : Der Jahresr{\"u}ckblick auf alles Wissenswerte im Arbeitsrecht des vergangenen Jahres}, series = {NWB - Steuer- und Wirtschaftsrecht}, journal = {NWB - Steuer- und Wirtschaftsrecht}, number = {10}, issn = {0028-3460}, pages = {703 -- 715}, year = {2021}, abstract = {Im Anschluss an die arbeitsrechtlichen Jahres{\"u}bersichten der vergangenen Jahre (NWB 5/2019 S. 266; NWB 8/2020 S. 557) gibt der nachfolgende Beitrag einen {\"U}berblick {\"u}ber relevante Entwicklungen im Arbeitsrecht des Jahres 2020. Der erste Teil besch{\"a}ftigt sich hierbei mit gesetzlichen {\"A}nderungen. Neben Regelungen, die auf die COVID-19-Pandemie zur{\"u}ckgef{\"u}hrt werden k{\"o}nnen, hat der Gesetzgeber auch andere Vorhaben umgesetzt. So wurde u. a. das Arbeitnehmerentsenderecht reformiert. F{\"u}r Diskussionen sorgt(e) zudem das Gesetzesvorhaben zur Regelung mobiler Arbeit. Im zweiten Teil werden f{\"u}r die Praxis wichtige h{\"o}chstrichterliche Gerichtsentscheidungen zum Arbeitsrecht erl{\"a}utert, alphabetisch sortiert von A (wie Antidiskriminierungsrecht) bis U (wie Urlaub).}, language = {de} } @article{Olbertz2021, author = {Olbertz, Klaus}, title = {Die Flexibilisierung von Arbeitszeit durch den Abruf von Arbeit : M{\"o}glichkeiten und Grenzen arbeitsvertraglicher Gestaltung zur Vermeidung von „Leerlaufzeiten"}, series = {NWB - Steuer- und Wirtschaftsrecht}, journal = {NWB - Steuer- und Wirtschaftsrecht}, number = {15}, issn = {0028-3460}, pages = {1055 -- 1063}, year = {2021}, abstract = {Die Arbeitswelt ist im Umbruch. Der Bedarf an flexiblen Arbeitszeitmodellen nimmt stetig zu, wobei die Corona-Pandemie dieses Bed{\"u}rfnis nochmals versch{\"a}rft hat. Gerade auch in kleineren und mittleren Unternehmen w{\"a}chst die Notwendigkeit, den Einsatz der Besch{\"a}ftigten m{\"o}glichst bedarfsgerecht zu steuern, also bei guter Auftragslage mehr Arbeitszeit abzurufen und bei ausbleibenden Auftr{\"a}gen die Arbeitszeit zu reduzieren und somit bezahlte „Leerlaufzeiten" zu vermeiden. Der Gesetzgeber stellt den Arbeitgebern hierf{\"u}r das Instrument der sog. Abrufarbeit ( \S 12 Teilzeit- und Befristungsgesetz - TzBfG ) zur Verf{\"u}gung. In dem nachfolgenden Beitrag werden M{\"o}glichkeiten und Grenzen der Abrufarbeit skizziert und konkrete arbeitsvertragliche Gestaltungsm{\"o}glichkeiten aufgezeigt.}, language = {de} } @article{Olbertz2021, author = {Olbertz, Klaus}, title = {Vertragsgestaltungen bei der Besch{\"a}ftigung von Rentnern in Unternehmen : (Befristete) Besch{\"a}ftigungsverh{\"a}ltnisse als sinnvolles Instrument zum Schließen von Personall{\"u}cken}, series = {NWB - Steuer- und Wirtschaftsrecht}, journal = {NWB - Steuer- und Wirtschaftsrecht}, number = {25}, issn = {0028-3460}, pages = {1810 -- 1817}, year = {2021}, language = {de} }