@article{AggeloussisGiannakouAlbrachtetal.2010, author = {Aggeloussis, Nickos and Giannakou, Erasmia and Albracht, Kirsten and Arampatzis, Adamantios}, title = {Reproducibility of fascicle length and pennation angle of gastrocnemius medialis in human gait in vivo}, series = {Gait and Posture}, volume = {31}, journal = {Gait and Posture}, number = {1}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0966-6362}, doi = {10.1016/j.gaitpost.2009.08.249}, pages = {73 -- 77}, year = {2010}, abstract = {The purpose of the current study was to examine the reproducibility of fascicle length and pennation angle of gastrocnemius medialis while human walking. To the best of our knowledge, this is the first study of the reproducibility of fascicle length and pennation angle of gastrocnemius medialis in vivo during human gait. Twelve males performed 10 gait trials on a treadmill, in 2 separate days. B-mode ultrasonography, with the ultrasound probe firmly adjusted in the transverse and frontal planes using a special cast, was used to measure the fascicle length and the pennation angle of the gastrocnemius medialis (GM). A Vicon 624 system with three cameras operating at 120 Hz was also used to record the ankle and knee joint angles. The results showed that measurements of fascicle length and pennation angle showed high reproducibility during the gait cycle, both within the same day and between different days. Moreover, the root mean square differences between the repeated waveforms of both variables were very small, compared with their ranges (fascicle length: RMS = ∼3 mm, range: 38-63 mm; pennation angle: RMS = ∼1.5°, range: 22-32°). However, their reproducibility was lower compared to the joint angles. It was found that representative data have to be derived by a wide number of gait trials (fascicle length ∼six trials, pennation angle more than 10 trials), to assure the reliability of the fascicle length and pennation angle in human gait.}, language = {en} } @article{ArampatzisKaramanidisMademlietal.2009, author = {Arampatzis, Adamantios and Karamanidis, Kiros and Mademli, Lida and Albracht, Kirsten}, title = {Plasticity of the human tendon to short and long-term mechanical loading}, series = {Exercise and Sport Sciences Reviews}, volume = {37}, journal = {Exercise and Sport Sciences Reviews}, number = {2}, issn = {1538-3008}, doi = {10.1097/JES.0b013e31819c2e1d}, pages = {66 -- 72}, year = {2009}, language = {en} } @article{MiyamotoSatoAbeetal.2016, author = {Miyamoto, Ko-Ichiro and Sato, Takuya and Abe, Minami and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Light-addressable potentiometric sensor as a sensing element in plug-based microfluidic devices}, series = {Micromachines}, volume = {7}, journal = {Micromachines}, number = {7}, publisher = {MDPI}, address = {Basel}, issn = {2072-666X}, doi = {10.3390/mi7070111}, pages = {111}, year = {2016}, abstract = {A plug-based microfluidic system based on the principle of the light-addressable potentiometric sensor (LAPS) is proposed. The LAPS is a semiconductor-based chemical sensor, which has a free addressability of the measurement point on the sensing surface. By combining a microfluidic device and LAPS, ion sensing can be performed anywhere inside the microfluidic channel. In this study, the sample solution to be measured was introduced into the channel in a form of a plug with a volume in the range of microliters. Taking advantage of the light-addressability, the position of the plug could be monitored and pneumatically controlled. With the developed system, the pH value of a plug with a volume down to 400 nL could be measured. As an example of plug-based operation, two plugs were merged in the channel, and the pH change was detected by differential measurement.}, language = {en} } @article{MahmoudiFleischhakerSahraietal.2008, author = {Mahmoudi, Mohammad and Fleischhaker, Robert and Sahrai, Mostafa and Evers, J{\"o}rg}, title = {Group velocity control in the ultraviolet domain via interacting dark-state resonances}, series = {Journal of physics B: Atomic, molecular and optical physics}, volume = {41}, journal = {Journal of physics B: Atomic, molecular and optical physics}, number = {2}, issn = {0953-4075}, doi = {10.1088/0953-4075/41/2/025504}, pages = {25504 -- 25600}, year = {2008}, language = {en} } @article{FleischhakerKraussSchaettigeretal.2013, author = {Fleischhaker, Robert and Krauß, Nico and Sch{\"a}ttiger, Farina and Dekorsy, Thomas}, title = {Consistent characterization of semiconductor saturable absorber mirrors with singe-pulse and pump-probe spectroscopy}, series = {Optics Express}, volume = {21}, journal = {Optics Express}, number = {6}, publisher = {Optica}, address = {Washington, DC}, issn = {1094-4087}, doi = {10.1364/OE.21.006764}, pages = {6764 -- 6776}, year = {2013}, language = {en} } @article{FleischhakerEvers2011, author = {Fleischhaker, Robert and Evers, J{\"o}rg}, title = {A Maxwell-Schr{\"o}dinger solver for quantum optical few-level systems}, series = {Computer Physics Communications}, volume = {182}, journal = {Computer Physics Communications}, number = {3}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0010-4655}, doi = {10.1016/j.cpc.2010.10.018}, pages = {739 -- 747}, year = {2011}, abstract = {The msprop program presented in this work is capable of solving the Maxwell-Schr{\"o}dinger equations for one or several laser fields propagating through a medium of quantum optical few-level systems in one spatial dimension and in time. In particular, it allows to numerically treat systems in which a laser field interacts with the medium with both its electric and magnetic component at the same time. The internal dynamics of the few-level system is modeled by a quantum optical master equation which includes coherent processes due to optical transitions driven by the laser fields as well as incoherent processes due to decay and dephasing. The propagation dynamics of the laser fields is treated in slowly varying envelope approximation resulting in a first order wave equation for each laser field envelope function. The program employs an Adams predictor formula second order in time to integrate the quantum optical master equation and a Lax-Wendroff scheme second order in space and time to evolve the wave equations for the fields. The source function in the Lax-Wendroff scheme is specifically adapted to allow taking into account the simultaneous coupling of a laser field to the polarization and the magnetization of the medium. To reduce execution time, a customized data structure is implemented and explained. In three examples the features of the program are demonstrated and the treatment of a system with a phase-dependent cross coupling of the electric and magnetic field component of a laser field is shown.}, language = {en} } @article{FleischhakerEvers2008, author = {Fleischhaker, Robert and Evers, J{\"o}rg}, title = {Nonlinear effects in pulse propagation through Doppler-broadened closed-loop atomic media}, series = {Physical Review A - Atomic, molecular, and optical physics}, volume = {77}, journal = {Physical Review A - Atomic, molecular, and optical physics}, number = {4}, issn = {1050-2947}, doi = {10.1103/PhysRevA.77.043805}, pages = {043805}, year = {2008}, language = {en} } @article{FleischhakerEvers2008, author = {Fleischhaker, Robert and Evers, J{\"o}rg}, title = {Four-wave mixing enhanced white-light cavity}, series = {Physical Review A - Atomic, molecular, and optical physics}, volume = {78}, journal = {Physical Review A - Atomic, molecular, and optical physics}, number = {5}, issn = {0556-2791}, pages = {051802(R)}, year = {2008}, language = {en} } @article{FleischhakerEvers2009, author = {Fleischhaker, Robert and Evers, J{\"o}rg}, title = {Phase-controlled pulse propagation in media with cross coupling of electric and magnetic probe field component}, series = {Physical Review A - Atomic, molecular, and optical physics}, volume = {80}, journal = {Physical Review A - Atomic, molecular, and optical physics}, number = {6}, issn = {1050-2947}, doi = {10.1103/PHYSREVA.80.063816}, pages = {063816}, year = {2009}, language = {en} } @article{WeldenSchejaSchoeningetal.2018, author = {Welden, Rene and Scheja, Sabrina and Sch{\"o}ning, Michael Josef and Wagner, Patrick and Wagner, Torsten}, title = {Electrochemical Evaluation of Light-Addressable Electrodes Based on TiO2 for the Integration in Lab-on-Chip Systems}, series = {physica status solidi a : applications and materials sciences}, volume = {215}, journal = {physica status solidi a : applications and materials sciences}, number = {15}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201800150}, pages = {Article number 1800150}, year = {2018}, abstract = {In lab-on-chip systems, electrodes are important for the manipulation (e.g., cell stimulation, electrolysis) within such systems. An alternative to commonly used electrode structures can be a light-addressable electrode. Here, due to the photoelectric effect, the conducting area can be adjusted by modification of the illumination area which enables a flexible control of the electrode. In this work, titanium dioxide based light-addressable electrodes are fabricated by a sol-gel technique and a spin-coating process, to deposit a thin film on a fluorine-doped tin oxide glass. To characterize the fabricated electrodes, the thickness, and morphological structure are measured by a profilometer and a scanning electron microscope. For the electrochemical behavior, the dark current and the photocurrent are determined for various film thicknesses. For the spatial resolution behavior, the dependency of the photocurrent while changing the area of the illuminated area is studied. Furthermore, the addressing of single fluid compartments in a three-chamber system, which is added to the electrode, is demonstrated.}, language = {en} }