@article{NabilPetersonSchmidtetal.2010, author = {Nabil, F. and Peterson, Leif Arne and Schmidt, A. and Geerdes, D.}, title = {Die Holzkuppel des Neuen Palais in Potsdam}, series = {Bauingenieur}, volume = {85}, journal = {Bauingenieur}, number = {8}, publisher = {Springer-VDI-Verlag}, address = {D{\"u}sseldorf}, issn = {0005-6650}, pages = {324 -- 330}, year = {2010}, language = {de} } @article{BergPostweilerSteuerDankertLeichtScholten2023, author = {Berg-Postweiler, Julia and Steuer-Dankert, Linda and Leicht-Scholten, Carmen}, title = {One size does not fit all: Applying antibias trainings in academia}, series = {The International Journal of Organizational Diversity}, volume = {24}, journal = {The International Journal of Organizational Diversity}, number = {1}, publisher = {Common Ground Research Networks}, issn = {2328-6261 (Print)}, doi = {10.18848/2328-6261/CGP/v24i01/1-23}, pages = {1 -- 23}, year = {2023}, abstract = {Antibias training is increasingly demanded and practiced in academia and industry to increase employees' sensitivity to discrimination, racism, and diversity. Under the heading of "Diversity Management," antibias trainings are mainly offered as one-off workshops intending to raise awareness of unconscious biases, create a diversity-affirming corporate culture, promote awareness of the potential of diversity, and ultimately enable the reflection of diversity in development processes. However, coming from childhood education, research and scientific articles on the sustainable effectiveness of antibias in adulthood, especially in academia, are very scarce. In order to fill this research gap, the article aims to explore how sustainable the effects of individual antibias trainings on participants' behavior are. In order to investigate this, participant observation in a qualitative pre-post setting was conducted, analyzing antibias training in an academic context. Two observers actively participated in the training sessions and documented the activities and reflection processes of the participants. Overall, the results question the effectiveness of single antibias trainings and show that a target-group adaptive approach is mandatory owing to the background of the approach in early childhood education. Therefore, antibias work needs to be adapted to the target group's needs and realities of life. Furthermore, the study reveals that single antibias trainings must be embedded in a holistic diversity management approach to stimulate sustainable reflection processes among the target group. This article is one of the first to scientifically evaluate antibias training effectiveness, especially in engineering sciences and the university context.}, language = {en} } @article{Timme2024, author = {Timme, Michael}, title = {Kaufvertrag: Das Zusammentreffen von Beschaffenheitsvereinbarung und Gew{\"a}hrleistungsausschluss - ein Spannungsverh{\"a}ltnis}, series = {Monatsschrift f{\"u}r Deutsches Recht}, volume = {78}, journal = {Monatsschrift f{\"u}r Deutsches Recht}, number = {12}, publisher = {Verlag Dr. Otto Schmidt}, address = {K{\"o}ln}, issn = {2194-4202 (online)}, doi = {10.9785/mdtr-2024-781203}, pages = {745 -- 748}, year = {2024}, abstract = {Wer A sagt, muss zumindest im Kaufrecht nicht immer B sagen: Es kommt nicht selten vor, dass sich in einem Kaufvertrag einerseits ein wirksamer Ausschluss der Gew{\"a}hrleistung des Verk{\"a}ufers f{\"u}r Sachm{\"a}ngel findet, die Parteien aber andererseits gleichwohl eine Beschaffenheitsvereinbarung f{\"u}r bestimmte Eigenschaften vertraglich festlegen. In diesem Problemfeld f{\"u}hrt eine aktuelle Entscheidung des BGH zu weiteren Kl{\"a}rungen f{\"u}r die Praxis (BGH, Urt. v. 10.4.2024 - VIII ZR 161/23, MDR 2024, 706). Der folgende Beitrag setzt sich mit den vielf{\"a}ltigen Aspekten der Entscheidung auseinander und erl{\"a}utert, aus welchen Gr{\"u}nden der BGH dem K{\"a}ufer einige goldene Br{\"u}cken f{\"u}r einen Schadensersatzanspruch gebaut hat.}, language = {de} } @article{OezsoyluAliaziziWagneretal.2024, author = {{\"O}zsoylu, Dua and Aliazizi, Fereshteh and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Template bacteria-free fabrication of surface imprinted polymer-based biosensor for E. coli detection using photolithographic mimics: Hacking bacterial adhesion}, series = {Biosensors and Bioelectronics}, volume = {261}, journal = {Biosensors and Bioelectronics}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-4235 (eISSN)}, doi = {10.1016/j.bios.2024.116491}, pages = {11 Seiten}, year = {2024}, abstract = {As one class of molecular imprinted polymers (MIPs), surface imprinted polymer (SIP)-based biosensors show great potential in direct whole-bacteria detection. Micro-contact imprinting, that involves stamping the template bacteria immobilized on a substrate into a pre-polymerized polymer matrix, is the most straightforward and prominent method to obtain SIP-based biosensors. However, the major drawbacks of the method arise from the requirement for fresh template bacteria and often non-reproducible bacteria distribution on the stamp substrate. Herein, we developed a positive master stamp containing photolithographic mimics of the template bacteria (E. coli) enabling reproducible fabrication of biomimetic SIP-based biosensors without the need for the "real" bacteria cells. By using atomic force and scanning electron microscopy imaging techniques, respectively, the E. coli-capturing ability of the SIP samples was tested, and compared with non-imprinted polymer (NIP)-based samples and control SIP samples, in which the cavity geometry does not match with E. coli cells. It was revealed that the presence of the biomimetic E. coli imprints with a specifically designed geometry increases the sensor E. coli-capturing ability by an "imprinting factor" of about 3. These findings show the importance of geometry-guided physical recognition in bacterial detection using SIP-based biosensors. In addition, this imprinting strategy was employed to interdigitated electrodes and QCM (quartz crystal microbalance) chips. E. coli detection performance of the sensors was demonstrated with electrochemical impedance spectroscopy (EIS) and QCM measurements with dissipation monitoring technique (QCM-D).}, language = {en} } @article{GraesslRenzHezeletal.2013, author = {Gr{\"a}ßl, Andreas and Renz, Wolfgang and Hezel, Fabian and Dieringer, Matthias A. and Winter, Lukas and {\"O}zerdem, Celal and Rieger, Jan and Kellmann, Peter and Santoro, Davide and Lindel, Tomasz D. and Frauenrath, Tobias and Pfeiffer, Harald and Niendorf, Thoralf}, title = {Modular 32-channel transceiver coil array for cardiac MRI at 7.0T}, series = {Magnetic Resonance in Medicine}, volume = {72}, journal = {Magnetic Resonance in Medicine}, number = {1}, publisher = {Wiley-Liss}, address = {New York}, issn = {1522-2594}, doi = {10.1002/mrm.24903}, pages = {276 -- 290}, year = {2013}, abstract = {Purpose To design and evaluate a modular transceiver coil array with 32 independent channels for cardiac MRI at 7.0T. Methods The modular coil array comprises eight independent building blocks, each containing four transceiver loop elements. Numerical simulations were used for B1+ field homogenization and radiofrequency (RF) safety validation. RF characteristics were examined in a phantom study. The array's suitability for accelerated high spatial resolution two-dimensional (2D) FLASH CINE imaging of the heart was examined in a volunteer study. Results Transmission field adjustments and RF characteristics were found to be suitable for the volunteer study. The signal-to-noise intrinsic to 7.0T together with the coil performance afforded a spatial resolution of 1.1 × 1.1 × 2.5 mm3 for 2D CINE FLASH MRI, which is by a factor of 6 superior to standardized CINE protocols used in clinical practice at 1.5T. The 32-channel transceiver array supports one-dimensional acceleration factors of up to R = 4 without impairing image quality significantly. Conclusion The modular 32-channel transceiver cardiac array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0T.}, language = {en} } @article{FrauenrathFuchsDieringeretal.2012, author = {Frauenrath, Tobias and Fuchs, Katharina and Dieringer, Matthias A. and {\"O}zerdem, Celal and Patel, Nishan and Renz, Wolfgang and Greiser, Andreas and Elgeti, Thomas and Niendorf, Thoralf}, title = {Detailing the use of magnetohydrodynamic effects for synchronization of MRI with the cardiac cycle: A feasibility study}, series = {Journal of Magnetic Resonance Imaging}, volume = {36}, journal = {Journal of Magnetic Resonance Imaging}, number = {2}, publisher = {Wiley-Liss}, address = {New York}, issn = {1522-2586}, doi = {10.1002/jmri.23634}, pages = {364 -- 372}, year = {2012}, abstract = {Purpose: To investigate the feasibility of using magnetohydrodynamic (MHD) effects for synchronization of magnetic resonance imaging (MRI) with the cardiac cycle. Materials and Methods: The MHD effect was scrutinized using a pulsatile flow phantom at B0 = 7.0 T. MHD effects were examined in vivo in healthy volunteers (n = 10) for B0 ranging from 0.05-7.0 T. Noncontrast-enhanced MR angiography (MRA) of the carotids was performed using a gated steady-state free-precession (SSFP) imaging technique in conjunction with electrocardiogram (ECG) and MHD synchronization. Results: The MHD potential correlates with flow velocities derived from phase contrast MRI. MHD voltages depend on the orientation between B0 and the flow of a conductive fluid. An increase in the interelectrode spacing along the flow increases the MHD potential. In vivo measurement of the MHD effect provides peak voltages of 1.5 mV for surface areas close to the common carotid artery at B0 = 7.0 T. Synchronization of MRI with the cardiac cycle using MHD triggering is feasible. MHD triggered MRA of the carotids at 3.0 T showed an overall image quality and richness of anatomic detail, which is comparable to ECG-triggered MRAs. Conclusion: This feasibility study demonstrates the use of MHD effects for synchronization of MR acquisitions with the cardiac cycle. J. Magn. Reson. Imaging 2012;36:364-372. © 2012 Wiley Periodicals, Inc.}, language = {en} } @article{GrandeMeffertSchoenbergeretal.2012, author = {Grande, Marion and Meffert, Elisabeth and Schoenberger, Eva and Jung, Stefanie and Frauenrath, Tobias and Huber, Walter and Hussmann, Katja and Moormann, Mareike and Heim, Stefan}, title = {From a concept to a word in a syntactically complete sentence: An fMRI study on spontaneous language production in an overt picture description task}, series = {NeuroImage}, volume = {61}, journal = {NeuroImage}, number = {3}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1522-2586}, doi = {10.1016/j.neuroimage.2012.03.087}, pages = {702 -- 714}, year = {2012}, abstract = {Spontaneous language has rarely been subjected to neuroimaging studies. This study therefore introduces a newly developed method for the analysis of linguistic phenomena observed in continuous language production during fMRI. Most neuroimaging studies investigating language have so far focussed on single word or — to a smaller extent — sentence processing, mostly due to methodological considerations. Natural language production, however, is far more than the mere combination of words to larger units. Therefore, the present study aimed at relating brain activation to linguistic phenomena like word-finding difficulties or syntactic completeness in a continuous language fMRI paradigm. A picture description task with special constraints was used to provoke hesitation phenomena and speech errors. The transcribed speech sample was segmented into events of one second and each event was assigned to one category of a complex schema especially developed for this purpose. The main results were: conceptual planning engages bilateral activation of the precuneus. Successful lexical retrieval is accompanied - particularly in comparison to unsolved word-finding difficulties - by the left middle and superior temporal gyrus. Syntactic completeness is reflected in activation of the left inferior frontal gyrus (IFG) (area 44). In sum, the method has proven to be useful for investigating the neural correlates of lexical and syntactic phenomena in an overt picture description task. This opens up new prospects for the analysis of spontaneous language production during fMRI.}, language = {en} } @article{MartinFrauenrathOezerdemetal.2011, author = {Martin, Conrad and Frauenrath, Tobias and {\"O}zerdem, Celal and Renz, Wolfgang and Niendorf, Thoralf}, title = {Development and evaluation of a small and mobile Magneto Alert Sensor (MALSE) to support safety requirements for magnetic resonance imaging}, series = {European Radiology}, volume = {21}, journal = {European Radiology}, publisher = {Springer}, address = {Berlin, Heidelberg}, issn = {1432-1084}, doi = {10.1007/s00330-011-2153-z}, pages = {2187 -- 2192}, year = {2011}, abstract = {Objective The purpose of this study is to (i) design a small and mobile Magnetic field ALert SEnsor (MALSE), (ii) to carefully evaluate its sensors to their consistency of activation/deactivation and sensitivity to magnetic fields, and (iii) to demonstrate the applicability of MALSE in 1.5 T, 3.0 T and 7.0 T MR fringe field environments. Methods MALSE comprises a set of reed sensors, which activate in response to their exposure to a magnetic field. The activation/deactivation of reed sensors was examined by moving them in/out of the fringe field generated by 7TMR. Results The consistency with which individual reed sensors would activate at the same field strength was found to be 100\% for the setup used. All of the reed switches investigated required a substantial drop in ambient magnetic field strength before they deactivated. Conclusions MALSE is a simple concept for alerting MRI staff to a ferromagnetic object being brought into fringe magnetic fields which exceeds MALSEs activation magnetic field. MALSE can easily be attached to ferromagnetic objects within the vicinity of a scanner, thus creating a barrier for hazardous situations induced by ferromagnetic parts which should not enter the vicinity of an MR-system to occur.}, language = {en} } @article{DieringerRenzLindeletal.2011, author = {Dieringer, Matthias A. and Renz, Wolfgang and Lindel, Tomasz D. and Seifert, Frank and Frauenrath, Tobias and von Knobelsdorf-Brenkenhoff, Florian and Waiczies, Helmar and Hoffmann, Werner and Rieger, Jan and Pfeiffer, Harald and Ittermann, Bernd and Schulz-Menger, Jeanette and Niendorf, Thoralf}, title = {Design and application of a four-channel transmit/receive surface coil for functional cardiac imaging at 7T}, series = {Journal of Magnetic Resonance Imaging}, volume = {33}, journal = {Journal of Magnetic Resonance Imaging}, number = {3}, publisher = {Wiley-Liss}, address = {New York}, issn = {1522-2586}, doi = {10.1002/jmri.22451}, pages = {736 -- 741}, year = {2011}, abstract = {Purpose To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T. Materials and Methods A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3. Results Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach. Conclusion A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated.}, language = {en} } @article{AyalaHarrisKleefeldetal.2023, author = {Ayala, Rafael Ceja and Harris, Isaac and Kleefeld, Andreas and Pallikarakis, Nikolaos}, title = {Analysis of the transmission eigenvalue problem with two conductivity parameters}, series = {Applicable Analysis}, journal = {Applicable Analysis}, publisher = {Taylor \& Francis}, issn = {0003-6811}, doi = {10.1080/00036811.2023.2181167}, pages = {37 Seiten}, year = {2023}, abstract = {In this paper, we provide an analytical study of the transmission eigenvalue problem with two conductivity parameters. We will assume that the underlying physical model is given by the scattering of a plane wave for an isotropic scatterer. In previous studies, this eigenvalue problem was analyzed with one conductive boundary parameter whereas we will consider the case of two parameters. We prove the existence and discreteness of the transmission eigenvalues as well as study the dependence on the physical parameters. We are able to prove monotonicity of the first transmission eigenvalue with respect to the parameters and consider the limiting procedure as the second boundary parameter vanishes. Lastly, we provide extensive numerical experiments to validate the theoretical work.}, language = {en} }