@article{TippkoetterRoikaewUlber2008, author = {Tippk{\"o}tter, Nils and Roikaew, W. and Ulber, Roland}, title = {Nitrate removal from whey concentrate with biotechnological regeneration of the waste water}, series = {European dairy magazine : EDM}, journal = {European dairy magazine : EDM}, number = {1}, isbn = {0936-6318}, pages = {30 -- 32}, year = {2008}, language = {en} } @article{UndenBeckerBongaertsetal.1995, author = {Unden, G. and Becker, S. and Bongaerts, Johannes and Holighaus, G. and Schirawski, J. and Six, S.}, title = {O2-sensing and O2-dependent gene regulation in facultatively anaerobic bacteria}, series = {Archives of microbiology}, volume = {Vol. 164}, journal = {Archives of microbiology}, number = {Iss. 2}, issn = {1432-072X (E-Journal); 0003-9276 (Print); 0302-8933 (Print)}, pages = {81 -- 90}, year = {1995}, language = {en} } @inproceedings{TippkoetterStueckmannWinkelmannetal.2007, author = {Tippk{\"o}tter, Nils and St{\"u}ckmann, H. and Winkelmann, G. and Noack, U. and Beutel, S. and Scheper, T. and Ulber, Roland}, title = {Optimisation of antibody-labelling of gold colloids for their application in an immunchromatographic assay for microcystin-LR}, series = {European BioPerspectives : celebrating the 25th DECHEMA annual convention of biotechnologists ; 30 May - 1 June 2007, Cologne, Germany ; book of abstracts ; abstracts, poster programme}, booktitle = {European BioPerspectives : celebrating the 25th DECHEMA annual convention of biotechnologists ; 30 May - 1 June 2007, Cologne, Germany ; book of abstracts ; abstracts, poster programme}, publisher = {Dechema}, address = {Frankfurt am Main}, pages = {126}, year = {2007}, language = {en} } @misc{AlKaidyTippkoetterUlber2016, author = {Al-Kaidy, Huschyar and Tippk{\"o}tter, Nils and Ulber, Roland}, title = {Vorrichtung und Verfahren zur Bestimmung des Kontaktwinkels eines Fl{\"u}ssigk{\"o}rpers mit einer Festk{\"o}rperoberfl{\"a}che}, year = {2016}, abstract = {Die vorliegende Erfindung betrifft eine Vorrichtung und ein Verfahren zur Bestimmung des Kontaktwinkels eines fl{\"u}ssigen oder mit Fl{\"u}ssigkeit gef{\"u}llten K{\"o}rpers. Dieser besteht aus einem Tr{\"a}ger (1) und einer damit verbundenen, in einem Winkelbereich von mehr als 0 ° bis maximal 90 ° neigbaren Ebene (8) mit einer darin ausgebildeten Abrollbahn (9) f{\"u}r den fl{\"u}ssigen oder mit Fl{\"u}ssigkeit gef{\"u}llten K{\"o}rper. An der Ebene (8) sind mehrere Sensoren (11,12) zur Erfassung der Rolldauer des K{\"o}rpers entlang der Rollstrecke angeordnet. Erfindungsgem{\"a}ß ist vorgesehen, dass die Einstellung des Neigungswinkels der Ebene (8) {\"u}ber ein Winkelmessger{\"a}t (10) erfolgt, wodurch ein Abrollwinkel erfassbar ist, bei dem der K{\"o}rper in Bewegung ger{\"a}t. Aus der Rolldauer, der Rollstrecke und dem Abrollwinkel wird der Kontaktwinkel des K{\"o}rpers ermittelt.}, language = {de} } @article{TippkoetterDeterdingUlber2008, author = {Tippk{\"o}tter, Nils and Deterding, A. and Ulber, Roland}, title = {Determination of acetic acid in fermentation broth by gas-diffusion technique}, series = {Engineering in Life Sciences}, volume = {8}, journal = {Engineering in Life Sciences}, number = {1, Special Issue: Technical Systems for the Use in Life Sciences}, doi = {10.1002/elsc.200820227}, pages = {62 -- 67}, year = {2008}, abstract = {Due to the interfering effects of acetic acid in many fermentation processes, a gas-diffusion technique was developed for the online determination of acetic acid. The measurements were accomplished with a flow diffusion analysis (FDA) unit from the TRACE Analytics GmbH, Braunschweig, Germany. The diffusion analysis is based on the UV-absorbance of acetic acid at 205 nm. The measurement was achieved by the separation of an acceptor and a carrier stream (acidified fermentation broth) using a gas permeable polytetrafluoroethylene (PTFE) membrane, whereby broth constituents that would otherwise disturb the UV-measurement of acetic acid, are held back efficiently. Merely, the fermentation by-products, e.g. formic acid, is capable of diffusing through the membrane. While formic acid can disturb the measurement, carbon dioxide does not absorb at 205 nm. The method operates with time-dependent sample enrichment. During the analysis, a small volume of the acceptor stream is stopped for a defined time interval in the acceptor chamber. During this period, the gaseous acetic acid diffuses through the membrane and is enriched in the acceptor chamber. Subsequently after the enrichment, the acceptor stream flows through a UV-detector. The intensity of the signal is proportional to the acetic acid concentration. Online measurements in bioreactors via a sterile filtration probe have been accomplished. A linear calibration in the range of 0.5-5.0 g/L acetic acid with a relative standard deviation of <5 \% was obtained. A sampling rate of 8 samples per hour was possible. The system was applied for the determination of acetic acid in E. coli fermentation broth. The instrument is easy to clean, very user-friendly and does not require any toxic or expensive reagents.}, language = {en} } @article{BaeckerRakowskiPoghossianetal.2013, author = {B{\"a}cker, Matthias and Rakowski, D. and Poghossian, Arshak and Biselli, Manfred and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Chip-based amperometric enzyme sensor system for monitoring of bioprocesses by flow-injection analysis}, series = {Journal of Biotechnology}, volume = {163}, journal = {Journal of Biotechnology}, number = {4}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0168-1656}, doi = {10.1016/j.jbiotec.2012.03.014}, pages = {371 -- 376}, year = {2013}, abstract = {A microfluidic chip integrating amperometric enzyme sensors for the detection of glucose, glutamate and glutamine in cell-culture fermentation processes has been developed. The enzymes glucose oxidase, glutamate oxidase and glutaminase were immobilized by means of cross-linking with glutaraldehyde on platinum thin-film electrodes integrated within a microfluidic channel. The biosensor chip was coupled to a flow-injection analysis system for electrochemical characterization of the sensors. The sensors have been characterized in terms of sensitivity, linear working range and detection limit. The sensitivity evaluated from the respective peak areas was 1.47, 3.68 and 0.28 μAs/mM for the glucose, glutamate and glutamine sensor, respectively. The calibration curves were linear up to a concentration of 20 mM glucose and glutamine and up to 10 mM for glutamate. The lower detection limit amounted to be 0.05 mM for the glucose and glutamate sensor, respectively, and 0.1 mM for the glutamine sensor. Experiments in cell-culture medium have demonstrated a good correlation between the glutamate, glutamine and glucose concentrations measured with the chip-based biosensors in a differential-mode and the commercially available instrumentation. The obtained results demonstrate the feasibility of the realized microfluidic biosensor chip for monitoring of bioprocesses.}, language = {en} } @article{TranBongaertsVladetal.1997, author = {Tran, Quang Hon and Bongaerts, Johannes and Vlad, Dorina and Unden, Gottfried}, title = {Requirement for the proton-pumping NADH dehydrogenase I of Escherichia coli in respiration of NADH to fumarate and its bioenergetic implications}, series = {European journal of biochemistry}, volume = {Vol. 244}, journal = {European journal of biochemistry}, number = {Iss. 1}, issn = {0014-2956}, pages = {155 -- 160}, year = {1997}, language = {en} } @article{WiegandVoigtAlbrechtetal.2013, author = {Wiegand, Sandra and Voigt, Birgit and Albrecht, Dirk and Bongaerts, Johannes and Evers, Stefan and Hecker, Michael and Daniel, Rolf and Liesegang, Heiko}, title = {Fermentation stage-dependent adaptations of Bacillus licheniformis during enzyme production}, series = {Microbial Cell Factories}, volume = {12}, journal = {Microbial Cell Factories}, publisher = {Biomed Central}, address = {London}, issn = {1475-2859}, doi = {10.1186/1475-2859-12-120}, pages = {120}, year = {2013}, language = {en} } @inproceedings{TippkoetterRoikaewUlber2008, author = {Tippk{\"o}tter, Nils and Roikaew, W. and Ulber, Roland}, title = {An automated pilot plant for the bioengineering processing of concentrated whey}, series = {European BioPerspectives : in cooperation with BIOTECHNICA 2008 : 7 - 9 October 2008 Hannover, Germany ; book of abstracts ; abstracts, poster programme}, booktitle = {European BioPerspectives : in cooperation with BIOTECHNICA 2008 : 7 - 9 October 2008 Hannover, Germany ; book of abstracts ; abstracts, poster programme}, publisher = {Dechema}, address = {Frankfurt am Main}, pages = {98}, year = {2008}, language = {en} } @article{ZientzBongaertsUnden1998, author = {Zientz, Evelyn and Bongaerts, Johannes and Unden, Gottfried}, title = {Fumarate regulation of gene expression in Escherichia coli by the DcuSR (dcuSR genes) two-component regulatory system}, series = {Journal of bacteriology}, volume = {Vol. 180}, journal = {Journal of bacteriology}, number = {No. 20}, issn = {1098-5530 (E-Journal); 0021-9193 (Print)}, pages = {5421 -- 5425}, year = {1998}, language = {en} }