@inproceedings{FrantzBinderBuschetal.2020, author = {Frantz, Cathy and Binder, Matthias and Busch, Konrad and Ebert, Miriam and Heinrich, Andreas and Kaczmarkiewicz, Nadine and Schl{\"o}gl-Knothe, B{\"a}rbel and Kunze, Tobias and Schuhbauer, Christian and Stetka, Markus and Schwager, Christian and Spiegel, Michael and Teixeira Boura, Cristiano Jos{\´e} and Bauer, Thomas and Bonk, Alexander and Eisen, Stefan and Funck, Bernhard}, title = {Basic Engineering of a High Performance Molten Salt Tower Receiver System}, series = {AIP Conference Proceedings}, booktitle = {AIP Conference Proceedings}, doi = {10.1063/5.0085895}, pages = {1 -- 10}, year = {2020}, abstract = {The production of dispatchable renewable energy will be one of the most important key factors of the future energy supply. Concentrated solar power (CSP) plants operated with molten salt as heat transfer and storage media are one opportunity to meet this challenge. Due to the high concentration factor of the solar tower technology the maximum process temperature can be further increased which ultimately decreases the levelized costs of electricity of the technology (LCOE). The development of an improved tubular molten salt receiver for the next generation of molten salt solar tower plants is the aim of this work. The receiver is designed for a receiver outlet temperature up to 600 °C. Together with a complete molten salt system, the receiver will be integrated into the Multi-Focus-Tower (MFT) in J{\"u}lich (Germany). The paper describes the basic engineering of the receiver, the molten salt tower system and a laboratory corrosion setup.}, language = {en} } @article{HueningBackes2020, author = {H{\"u}ning, Felix and Backes, Andreas}, title = {Direct observation of large Barkhausen jump in thin Vicalloy wires}, series = {IEEE Magnetics Letters}, volume = {11}, journal = {IEEE Magnetics Letters}, number = {Art. 2506504}, publisher = {IEEE}, address = {New York, NY}, isbn = {1949-307X}, doi = {10.1109/LMAG.2020.3046411}, pages = {1 -- 4}, year = {2020}, language = {en} } @article{GazdaMaurischat2020, author = {Gazda, Quentin and Maurischat, Andreas}, title = {Special functions and Gauss-Thakur sums in higher rank and dimension}, publisher = {De Gruyter}, address = {Berlin}, pages = {26 Seiten}, year = {2020}, language = {en} } @incollection{GebhardtHoetter2019, author = {Gebhardt, Andreas and Hoetter, Jan-Steffen}, title = {Rapid Tooling}, series = {CIRP Encyclopedia of Production Engineering}, booktitle = {CIRP Encyclopedia of Production Engineering}, publisher = {Springer}, address = {Berlin, Heidelberg}, isbn = {978-3-662-53120-4}, doi = {10.1007/978-3-662-53120-4}, pages = {39 -- 52}, year = {2019}, language = {en} } @inproceedings{ChavezBermudezWollert2020, author = {Chavez Bermudez, Victor Francisco and Wollert, J{\"o}rg}, title = {Arduino based Framework for Rapid Application Development of a Generic IO-Link interface}, series = {Kommunikation und Bildverarbeitung in der Automation. Ausgew{\"a}hlte Beitr{\"a}ge der Jahreskolloquien KommA und BVAu 2018}, booktitle = {Kommunikation und Bildverarbeitung in der Automation. Ausgew{\"a}hlte Beitr{\"a}ge der Jahreskolloquien KommA und BVAu 2018}, publisher = {Springer Vieweg}, address = {Berlin}, isbn = {978-3-662-59895-5}, doi = {10.1007/978-3-662-59895-5_2}, pages = {21 -- 33}, year = {2020}, abstract = {The implementation of IO-Link in the automation industry has increased over the years. Its main advantage is it offers a digital point-to-point plugand-play interface for any type of device or application. This simplifies the communication between devices and increases productivity with its different features like self-parametrization and maintenance. However, its complete potential is not always used. The aim of this paper is to create an Arduino based framework for the development of generic IO-Link devices and increase its implementation for rapid prototyping. By generating the IO device description file (IODD) from a graphical user interface, and further customizable options for the device application, the end-user can intuitively develop generic IO-Link devices. The peculiarity of this framework relies on its simplicity and abstraction which allows to implement any sensor functionality and virtually connect any type of device to an IO-Link master. This work consists of the general overview of the framework, the technical background of its development and a proof of concept which demonstrates the workflow for its implementation.}, language = {en} } @book{Pieper2019, author = {Pieper, Martin}, title = {Quantenmechanik: Einf{\"u}hrung in die mathematische Formulierung}, publisher = {Springer Spektrum}, address = {Wiesbaden}, isbn = {978-3-658-28328-5}, doi = {10.1007/978-3-658-28329-2}, pages = {XI, 33 Seiten}, year = {2019}, language = {de} } @article{ConzenAlbannaWeissetal.2018, author = {Conzen, Catharina and Albanna, Walid and Weiss, Miriam and K{\"u}rten, David and Vilser, Walthard and Kotliar, Konstantin and Z{\"a}ske, Charlotte and Clusmann, Hans and Schubert, Gerrit Alexander}, title = {Vasoconstriction and Impairment of Neurovascular Coupling after Subarachnoid Hemorrhage: a Descriptive Analysis of Retinal Changes}, series = {Translational Stroke Research}, journal = {Translational Stroke Research}, number = {9}, publisher = {Springer Nature}, address = {Cham}, issn = {1868-601X}, doi = {10.1007/s12975-017-0585-8}, pages = {284 -- 293}, year = {2018}, abstract = {Impaired cerebral autoregulation and neurovascular coupling (NVC) contribute to delayed cerebral ischemia after subarachnoid hemorrhage (SAH). Retinal vessel analysis (RVA) allows non-invasive assessment of vessel dimension and NVC hereby demonstrating a predictive value in the context of various neurovascular diseases. Using RVA as a translational approach, we aimed to assess the retinal vessels in patients with SAH. RVA was performed prospectively in 24 patients with acute SAH (group A: day 5-14), in 11 patients 3 months after ictus (group B: day 90 ± 35), and in 35 age-matched healthy controls (group C). Data was acquired using a Retinal Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and NVC using flicker-light excitation. Diameter of retinal vessels—central retinal arteriolar and venular equivalent—was significantly reduced in the acute phase (p < 0.001) with gradual improvement in group B (p < 0.05). Arterial NVC of group A was significantly impaired with diminished dilatation (p < 0.001) and reduced area under the curve (p < 0.01) when compared to group C. Group B showed persistent prolonged latency of arterial dilation (p < 0.05). Venous NVC was significantly delayed after SAH compared to group C (A p < 0.001; B p < 0.05). To our knowledge, this is the first clinical study to document retinal vasoconstriction and impairment of NVC in patients with SAH. Using non-invasive RVA as a translational approach, characteristic patterns of compromise were detected for the arterial and venous compartment of the neurovascular unit in a time-dependent fashion. Recruitment will continue to facilitate a correlation analysis with clinical course and outcome.}, language = {en} } @incollection{Blome2013, author = {Blome, Hans-Joachim}, title = {Die Tragweite der physikalischen Kosmologie}, series = {Exploring Uncertainty}, booktitle = {Exploring Uncertainty}, publisher = {Springer Gabler}, address = {Wiesbaden}, isbn = {978-3-658-00897-0}, doi = {10.1007/978-3-658-00897-0_6}, pages = {105 -- 150}, year = {2013}, language = {de} } @article{BerneckerBoyerGathmann2021, author = {Bernecker, Andreas and Boyer, Pierre C. and Gathmann, Christina}, title = {The Role of Electoral Incentives for Policy Innovation: Evidence from the US Welfare Reform}, series = {American Economic Journal: Economic Policy}, volume = {13}, journal = {American Economic Journal: Economic Policy}, number = {2}, publisher = {American Economic Association}, address = {Nashville, Tenn.}, issn = {1945-774X}, doi = {10.1257/pol.20190690}, pages = {26 -- 57}, year = {2021}, language = {en} } @techreport{Artmann2011, author = {Artmann, Gerhard}, title = {HPBioforce: Integrierte und automatisierte Screening Plattform eines 96-Well-Hochdurchsatz-Testsystems zur funktionellen Kraftmessung an einige um dicken Zell- und Gewebeschichten f{\"u}r die Arzneimittelforschung : gemeinsamer Abschlussbericht der FH Aachen, Hitec Zang GmbH, IKFE Mainz, IKFE Berlin und der Dr. Gerhard Schmidt GmbH zum InnoNet-Projekt ... ; Programm "F{\"o}rderung von innovativen Netzwerken" (InnoNet) des Bundesministerium f{\"u}r Wirtschaft und Technologie (BMWi) ; Laufzeit: 01.05.2007 bis 31.12.2010}, publisher = {Technische Informationsbibliothek u. Universit{\"a}tsbibliothek}, address = {Aachen [u.a.]}, doi = {10.2314/GBV:68757076X}, year = {2011}, language = {de} }