@article{MykoniouButenwegHoltschoppenetal.2016, author = {Mykoniou, Konstantin and Butenweg, Christoph and Holtschoppen, Britta and Klinkel, Sven}, title = {Seismic response analysis of adjacent liquid-storage tanks}, series = {Earthquake engineering and structural dynamics}, volume = {45}, journal = {Earthquake engineering and structural dynamics}, number = {11}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1096-9845 (E-Journal); 0098-8847 (Print)}, doi = {10.1002/eqe.2726}, pages = {1779 -- 1796}, year = {2016}, abstract = {A refined substructure technique in the frequency domain is developed, which permits consideration of the interaction effects among adjacent containers through the supporting deformable soil medium. The tank-liquid systems are represented by means of mechanical models, whereas discrete springs and dashpots stand for the soil beneath the foundations. The proposed model is employed to assess the responses of adjacent circular, cylindrical tanks for harmonic and seismic excitations over wide range of tank proportions and soil conditions. The influence of the number, spatial arrangement of the containers and their distance on the overall system's behavior is addressed. The results indicate that the cross-interaction effects can substantially alter the impulsive components of response of each individual element in a tank farm. The degree of this impact is primarily controlled by the tank proportions and the proximity of the predominant natural frequencies of the shell-liquid-soil systems and the input seismic motion. The group effects should be not a priori disregarded, unless the tanks are founded on shallow soil deposit overlying very stiff material or bedrock.}, language = {en} } @inproceedings{EdipGarevskiButenwegetal.2014, author = {Edip, Kemal and Garevski, Mihail and Butenweg, Christoph and Sesov, Vlatko and Bojadjieva, Julijana and Gjorgjiev, Igor}, title = {Boundary effects on seismic analysis of multi-storey frames considering soil structure interaction phenomenon}, series = {Seismic design of industrial facilities : proceedings of the International Conference on Seismic Design of Industrial Facilities (SeDIF-Conference) ; [Aachen, 26. - 27. September 2013] / Chair of Structural Statics and Dynamics, RWTH Aachen. Sven Klinkel ..., ed}, booktitle = {Seismic design of industrial facilities : proceedings of the International Conference on Seismic Design of Industrial Facilities (SeDIF-Conference) ; [Aachen, 26. - 27. September 2013] / Chair of Structural Statics and Dynamics, RWTH Aachen. Sven Klinkel ..., ed}, publisher = {Springer Vieweg}, address = {Wiesbaden}, organization = {International Conference on Seismic Design of Industrial Facilities <2013, Aachen>}, isbn = {978-3-658-02809-1 (Print) ; 978-3-658-02810-7}, doi = {10.1007/978-3-658-02810-7_47}, pages = {569 -- 576}, year = {2014}, language = {en} } @inproceedings{GiresiniButenwegAndreinietal.2014, author = {Giresini, Linda and Butenweg, Christoph and Andreini, M. and De Falco, A. and Sassu, M.}, title = {Numerical calibration of a macro-element for vaultes system in historic churches}, series = {9th International Conference on Structural Analyses of Historical Conctruction, 14 - 17 October, 2014, Mexico City}, booktitle = {9th International Conference on Structural Analyses of Historical Conctruction, 14 - 17 October, 2014, Mexico City}, organization = {International Conference on Structural Analyses of Historical Conctructions <9, 2014, Mexico City>}, pages = {1 -- 12}, year = {2014}, language = {en} } @inproceedings{RosinButenweg2014, author = {Rosin, Julia and Butenweg, Christoph}, title = {Seismic isolation of cylindrical liquid storage tanks}, series = {Proceedings of the 9th European Conference on Structural Dynamics, EURODYN 2014 Porto, Portugal, 30 June - 2 July 2014 / A. Cunha, E. Caetano, .... (eds.)}, booktitle = {Proceedings of the 9th European Conference on Structural Dynamics, EURODYN 2014 Porto, Portugal, 30 June - 2 July 2014 / A. Cunha, E. Caetano, .... (eds.)}, address = {Porto}, organization = {European Conference on Structural Dynamics, EURODYN <9, 2014, Porto>}, isbn = {978-972-752-165-4}, pages = {3145 -- 3152}, year = {2014}, language = {en} } @inproceedings{RosinButenwegBoesenetal.2018, author = {Rosin, Julia and Butenweg, Christoph and Boesen, Niklas and Gellert, Christoph}, title = {Evaluation of the Seismic Behavior of a Modern URM Building During the 2012 Northern Italy Earthquakes}, series = {16th European Conference on Earthquake Engineering, Thessaloniki, 18-21 June, 2018}, booktitle = {16th European Conference on Earthquake Engineering, Thessaloniki, 18-21 June, 2018}, pages = {1 -- 12}, year = {2018}, language = {en} } @incollection{AltayTaddeiButenwegetal.2014, author = {Altay, Okyay and Taddei, Francesca and Butenweg, Christoph and Klinkel, Sven}, title = {Vibration mitigation of wind turbine towers with tuned mass dampers}, series = {Wind turbine control and monitoring. (Advances in industrial control)}, booktitle = {Wind turbine control and monitoring. (Advances in industrial control)}, publisher = {Springer}, address = {Cham ; Heidelberg ; New York ; Dordrecht ; London}, isbn = {978-3-319-08412-1 (Print) ; 978-3-319-08413-8 (E-Book)}, doi = {10.1007/978-3-319-08413-8_12}, pages = {337 -- 373}, year = {2014}, abstract = {Because of its minor environmental impact, electricity generation using wind power is getting remarkable. The further growth of the wind industry depends on technological solutions to the challenges in production and construction of the turbines. Wind turbine tower vibrations, which limit power generation efficiency and cause fatigue problems with high maintenance costs, count as one of the main structural difficulties in the wind energy sector. To mitigate tower vibrations auxiliary measures are necessary. The effectiveness of tuned mass damper is verified by means of a numeric study on a 5 MW onshore reference wind turbine. Hereby, also seismic-induced vibrations and soil-structure interaction are considered. Acquired results show that tuned mass damper can effectively reduce resonant tower vibrations and improve the fatigue life of wind turbines. This chapter is also concerned with tuned liquid column damper and a semiactive application of it. Due to its geometric versatility and low prime costs, tuned liquid column dampers are a good alternative to other damping measures, in particular for slender structures like wind turbines.}, language = {en} } @inproceedings{KalkerNeumannButenwegetal.2005, author = {Kalker, Ines and Neumann, M. and Butenweg, Christoph and Holler, Stefan}, title = {Modelling of textile strengthened masonry}, series = {Proceedings of the Tenth International Conference on Civil, Structural and Environmental Engineering Computing : [Rome, Italy, 30. August - 2. September 2005] / ed. by B. H. V. Topping}, booktitle = {Proceedings of the Tenth International Conference on Civil, Structural and Environmental Engineering Computing : [Rome, Italy, 30. August - 2. September 2005] / ed. by B. H. V. Topping}, publisher = {Civil-Comp Press}, address = {Stirling}, organization = {International Conference on Civil, Structural and Environmental Engineering Computing <10, 2005, Rome>}, isbn = {1-905088-00-0}, doi = {10.4203/ccp.81.184}, pages = {447 -- 448}, year = {2005}, language = {en} } @inproceedings{KarimiButenwegToll2005, author = {Karimi, Iman and Butenweg, Christoph and Toll, Britta}, title = {Vulnerability assessment of industrial facilities}, series = {Proceedings of the Tenth International Conference on Civil, Structural and Environmental Engineering Computing : [Rome, Italy, 30. August - 2. September 2005] / ed. by B. H. V. Topping}, booktitle = {Proceedings of the Tenth International Conference on Civil, Structural and Environmental Engineering Computing : [Rome, Italy, 30. August - 2. September 2005] / ed. by B. H. V. Topping}, publisher = {Civil-Comp Press}, address = {Stirling}, organization = {International Conference on Civil, Structural and Environmental Engineering Computing <10, 2005, Rome>}, isbn = {1-905088-00-0}, doi = {10.4203/ccp.81.34}, pages = {34, 73 -- 75}, year = {2005}, language = {en} } @inproceedings{MistlerButenweg2005, author = {Mistler, Michael and Butenweg, Christoph}, title = {A seismic design procedure for masonry buildings}, series = {Proceedings of the Tenth International Conference on Civil, Structural and Environmental Engineering Computing : [Rome, Italy, 30. August - 2. September 2005] / ed. by B. H. V. Topping}, booktitle = {Proceedings of the Tenth International Conference on Civil, Structural and Environmental Engineering Computing : [Rome, Italy, 30. August - 2. September 2005] / ed. by B. H. V. Topping}, publisher = {Civil-Comp Press}, address = {Stirling}, organization = {International Conference on Civil, Structural and Environmental Engineering Computing <10, 2005, Rome>}, isbn = {1-905088-00-0}, doi = {10.4203/ccp.81.193}, pages = {465 -- 467}, year = {2005}, language = {en} } @inproceedings{RenaultButenwegMistler2005, author = {Renault, Philippe and Butenweg, Christoph and Mistler, Michael}, title = {Seismic vulnerability assessment system for bridges}, series = {Proceedings of the Tenth International Conference on Civil, Structural and Environmental Engineering Computing : [Rome, Italy, 30. August - 2. September 2005] / ed. by B. H. V. Topping}, booktitle = {Proceedings of the Tenth International Conference on Civil, Structural and Environmental Engineering Computing : [Rome, Italy, 30. August - 2. September 2005] / ed. by B. H. V. Topping}, publisher = {Civil-Comp Press}, address = {Stirling}, organization = {International Conference on Civil, Structural and Environmental Engineering Computing <10, 2005, Rome>}, isbn = {1-905088-00-0}, pages = {1 -- 14}, year = {2005}, language = {en} }