@inproceedings{DalguerRenaultChurilovetal.2016, author = {Dalguer, Luis A. and Renault, Philippe and Churilov, Sergey and Butenweg, Christoph}, title = {Evaluation of fragility curves for a three-storey-reinforced-concrete mock-up of SMART 2013 project}, series = {Transactions, SMiRT-23 : 23rd Conference on Structural Mechanics in Reactor Technology : Manchester, United Kingdom - August 10-14, 2015}, booktitle = {Transactions, SMiRT-23 : 23rd Conference on Structural Mechanics in Reactor Technology : Manchester, United Kingdom - August 10-14, 2015}, organization = {Conference on Structural Mechanics in Reactor Technology <23, 2015, Manchester>}, pages = {1 -- 9}, year = {2016}, language = {en} } @inproceedings{ButenwegRosinKubalski2013, author = {Butenweg, Christoph and Rosin, Julia and Kubalski, Thomas}, title = {Seismic response of conventional and base-isolated liquid storage tanks}, series = {International Conference on Earthquake Engineering : 29.-31.05.2013, Skopje, Mazedonien}, booktitle = {International Conference on Earthquake Engineering : 29.-31.05.2013, Skopje, Mazedonien}, organization = {International Conference on Earthquake Engineering <2013, Skopje>}, pages = {1 -- 8}, year = {2013}, language = {en} } @inproceedings{ButenwegKleemannAltayetal.2013, author = {Butenweg, Christoph and Kleemann, Anne and Altay, Okyay and Renault, Philippe}, title = {Simulation of impact-loads on reinforced concrete structural elements}, series = {22nd International Conference on Structural Mechanics in Reactor Technology 2013 : (SMiRT 22) ; San Francisco, California, USA, 18 - 23 August 2013}, booktitle = {22nd International Conference on Structural Mechanics in Reactor Technology 2013 : (SMiRT 22) ; San Francisco, California, USA, 18 - 23 August 2013}, organization = {International Conference on Structural Mechanics in Reactor Technology, SMIRT <22, 2013, San Francisco, Calif.>}, pages = {1 -- 10}, year = {2013}, language = {en} } @inproceedings{KernDikta2009, author = {Kern, Alexander and Dikta, Gerhard}, title = {Probability of damage of electrical and electronic systems due to indirect lightning flashes - investigation of data from German insurance companies}, year = {2009}, abstract = {In the presented paper data collected from the field related to damage statistics of electrical and electronic apparatus in household are reported and investigated. These damages (total number approx. 74000 cases), registered by five German insurance companies in 2005 and 2006, were adviced by customers as caused by lightning overvoltages. With the use of stochastical methods it is possible, to reasses the collected data and to distinguish between cases, which are with high probability caused by lightning overvoltages, and those, which are not. If there was an indication for a direct strike, this case was excluded, so the focus was only on indirect lightning flashes, i.e. only flashes to ground near the structure and flashes to or nearby an incoming service line were investigated. The data from the field contain the location of damaged apparatus (residence of the policy holder) and the distances of the nearest cloud-to-ground stroke to the location of the damage registered by the German lightning location network BLIDS at the date of damage. The statistical data along with some complementary numerical simulations allow to verify the correspondence of the Standards rules used for IEC 62305-2 with the field data and to define some correction needs. The results could lead to a better understanding whether a damage reported to an insurance company is really caused by indirect lightning, or not.}, subject = {Blitzschutz}, language = {en} } @inproceedings{GellertNordaButenweg2008, author = {Gellert, Christoph and Norda, Hannah and Butenweg, Christoph}, title = {Nonlinear behaviour of masonry under cyclic loading}, series = {7th European Conference on Structural Dynamics, EURODYN 2008 : 7-9 July 2008, Southampton}, booktitle = {7th European Conference on Structural Dynamics, EURODYN 2008 : 7-9 July 2008, Southampton}, organization = {European Conference on Structural Dynamics, EURODYN <7, 2008, Southampton>}, pages = {1 -- 12}, year = {2008}, language = {en} } @inproceedings{Bruessermann2005, author = {Br{\"u}ssermann, Klaus}, title = {Platform of Excellence in "Energy and Environment"}, year = {2005}, abstract = {The Ministry of Science and Research in North Rhine-Westphalia created eight platforms of excellence, one in the research area „Energy and Environment" in 2002 at ACUAS. This platform concentrates the research and development of 13 professors in J{\"u}lich and Aachen and of two scientific institutes with different topics: - NOWUM-Energy with emphasis on efficient and economic energy conversion - The Solar Institute J{\"u}lich - SIJ - being the largest research institute in the field of renewables at a University of Applied Sciences in Germany With this platform each possible energy conversion - nuclear, fossil, renewable- can be dealt with to help solving the two most important problems of mankind, energy and potable water. At the CSE are presented the historical development, some research results and the combined master studies in „Energy Systems" and „Nuclear Applications"}, subject = {Energietechnik}, language = {en} } @inproceedings{BruessermannDeuster2005, author = {Br{\"u}ssermann, Klaus and Deuster, M.}, title = {Temperature measurement to optimise the burning process}, year = {2005}, abstract = {One of the most important parameters in a burning chamber - in power stations, in waste to energy plants - is the temperature. This temperature is in the range of 700-1500 °C - one of the most advanced measuring methods being the acoustic pyrometry with the possibility of producing temperature mapping in one level of the burning chamber - comparable to computer tomography. The results of these measurements discussed in the presentation can be used - to fulfil the legal requirements in the FRG or in the EU - to equalise the temperature in one level of the burning chamber to optimise the steam production (better efficiency of the plant) and to minimise the production of temperature controlled flue gas components (NO, CO a. o.) - to control the SNCR-process if used.}, subject = {Pyrometrie}, language = {en} } @inproceedings{RenaultButenweg2005, author = {Renault, Philippe and Butenweg, Christoph}, title = {Seismic vulnerability assessment of bridges}, series = {First Munich Bridge Assessment Conference, MBAC 2005 : Munich, 20.-25. June 2005}, booktitle = {First Munich Bridge Assessment Conference, MBAC 2005 : Munich, 20.-25. June 2005}, organization = {Munich Bridge Assessment Conference <1, 2005>}, pages = {1 -- 16}, year = {2005}, language = {en} } @inproceedings{SurteesGillespieKernetal.2004, author = {Surtees, A. J. and Gillespie, A. and Kern, Alexander and Rousseau, A.}, title = {DEVELOPMENT OF A RISK ASSESSMENT CALCULATOR BASED ON A SIMPLIFIED FORM OF THE IEC 62305-2 STANDARD ON LIGHTNING PROTECTION}, year = {2004}, abstract = {Neue Blitzschutznorm IEC 62305. Entwicklung einer einfachen Software zur Risikoabw{\"a}gung}, language = {en} } @inproceedings{KernHeidlerSeeversetal.2004, author = {Kern, Alexander and Heidler, Fridolin and Seevers, M. and Zischank, Wolfgang J.}, title = {Magnetic Fields and Induced Voltages in case of a Direct Strike - Comparison of Results obtained from Measurements at a Scaled Building to those of IEC 62305-4}, isbn = {0304-3886}, year = {2004}, abstract = {In the paper the results obtained from experiments at a modelled reinforced building in case of a direct lightning strike are compared with calculations. The comparison includes peak values of the magnetic field Hmax, its derivative (dH/dt)max and of induced voltages umax in typical cable routings. The experiments are performed at a 1:6 scaled building and the results are extrapolated using the similarity relations theory. The calculations are based on the approximate formulae given in IEC 62305-4 and have to be supplemented by a rough estimation of the additional shielding effect of a second reinforcement layer. The comparison shows, that the measured peak values of the magnetic field and its derivative are mostly lower than the calculated. The induced voltages are in good agreement. Hence, calculations of the induced voltages based on IEC 62305-4 are a good method for lightning protection studies of buildings, where the reinforcement is used as a grid-like electromagnetic shield.}, subject = {Blitz}, language = {en} }