@article{ConzenAlbannaWeissetal.2018, author = {Conzen, Catharina and Albanna, Walid and Weiss, Miriam and K{\"u}rten, David and Vilser, Walthard and Kotliar, Konstantin and Z{\"a}ske, Charlotte and Clusmann, Hans and Schubert, Gerrit Alexander}, title = {Vasoconstriction and Impairment of Neurovascular Coupling after Subarachnoid Hemorrhage: a Descriptive Analysis of Retinal Changes}, series = {Translational Stroke Research}, journal = {Translational Stroke Research}, number = {9}, publisher = {Springer Nature}, address = {Cham}, issn = {1868-601X}, doi = {10.1007/s12975-017-0585-8}, pages = {284 -- 293}, year = {2018}, abstract = {Impaired cerebral autoregulation and neurovascular coupling (NVC) contribute to delayed cerebral ischemia after subarachnoid hemorrhage (SAH). Retinal vessel analysis (RVA) allows non-invasive assessment of vessel dimension and NVC hereby demonstrating a predictive value in the context of various neurovascular diseases. Using RVA as a translational approach, we aimed to assess the retinal vessels in patients with SAH. RVA was performed prospectively in 24 patients with acute SAH (group A: day 5-14), in 11 patients 3 months after ictus (group B: day 90 ± 35), and in 35 age-matched healthy controls (group C). Data was acquired using a Retinal Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and NVC using flicker-light excitation. Diameter of retinal vessels—central retinal arteriolar and venular equivalent—was significantly reduced in the acute phase (p < 0.001) with gradual improvement in group B (p < 0.05). Arterial NVC of group A was significantly impaired with diminished dilatation (p < 0.001) and reduced area under the curve (p < 0.01) when compared to group C. Group B showed persistent prolonged latency of arterial dilation (p < 0.05). Venous NVC was significantly delayed after SAH compared to group C (A p < 0.001; B p < 0.05). To our knowledge, this is the first clinical study to document retinal vasoconstriction and impairment of NVC in patients with SAH. Using non-invasive RVA as a translational approach, characteristic patterns of compromise were detected for the arterial and venous compartment of the neurovascular unit in a time-dependent fashion. Recruitment will continue to facilitate a correlation analysis with clinical course and outcome.}, language = {en} } @article{RiekeStollenwerkDahmenetal.2018, author = {Rieke, Christian and Stollenwerk, Dominik and Dahmen, Markus and Pieper, Martin}, title = {Modeling and optimization of a biogas plant for a demand-driven energy supply}, series = {Energy}, volume = {145}, journal = {Energy}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0360-5442}, doi = {10.1016/j.energy.2017.12.073}, pages = {657 -- 664}, year = {2018}, abstract = {Due to the Renewable Energy Act, in Germany it is planned to increase the amount of renewable energy carriers up to 60\%. One of the main problems is the fluctuating supply of wind and solar energy. Here biogas plants provide a solution, because a demand-driven supply is possible. Before running such a plant, it is necessary to simulate and optimize the process. This paper provides a new model of a biogas plant, which is as accurate as the standard ADM1 model. The advantage compared to ADM1 is that it is based on only four parameters compared to 28. Applying this model, an optimization was installed, which allows a demand-driven supply by biogas plants. Finally the results are confirmed by several experiments and measurements with a real test plant.}, language = {en} } @incollection{PielenRoethFlatten2018, author = {Pielen, Michael and R{\"o}th, Thilo and Flatten, T.}, title = {Erfolgsfaktoren k{\"u}nftiger Gesch{\"a}ftsmodelle von urbanen, geteilten Mobilit{\"a}tsdienstleistungen}, series = {Mobilit{\"a}t und digitale Transformation. (9. Wissenschaftsforum Mobilit{\"a}t. Tagungsband)}, booktitle = {Mobilit{\"a}t und digitale Transformation. (9. Wissenschaftsforum Mobilit{\"a}t. Tagungsband)}, editor = {Proff, H.}, publisher = {Springer Gabler}, address = {Wiesbaden}, isbn = {978-3-658-20779-3}, doi = {10.1007/978-3-658-20779-3_2}, pages = {435 -- 448}, year = {2018}, abstract = {Digitalisierung bezeichnet die Nutzung großer Datenmengen, die zu einer umfassenden Vernetzung aller Bereiche der Wirtschaft und Gesellschaft f{\"u}hren wird (BMWi, 2015 und {\"a}hnlich K{\"o}hler/Wollschl{\"a}ger, 2014: 79). Sie umfasst die Erhebung von analogen Informationen („Big Data" in einem engen Sinne; z.B. O´Leary, 2013), ihre Speicherung in einem digitaltechnischen System (lokale Speicherung oder „Cloud Computing" durch die Weiterentwickelung des Internets; z.B. Hashem et al., 2015: 101), die Analyse und Interpretation sowie den Transfer in andere Systeme („Internet der Dinge" bzw. „Internet of Things"; z.B. Ashton, 2009).}, language = {de} } @article{BhattaraiJabbariAndingetal.2018, author = {Bhattarai, Aroj and Jabbari, Medisa and Anding, Ralf and Staat, Manfred}, title = {Surgical treatment of vaginal vault prolapse using different prosthetic mesh implants: a finite element analysis}, series = {tm - Technisches Messen}, volume = {85}, journal = {tm - Technisches Messen}, number = {5}, publisher = {De Gruyter}, address = {Berlin}, issn = {2196-7113}, doi = {10.1515/teme-2017-0115}, pages = {331 -- 342}, year = {2018}, abstract = {Particularly multiparous elderly women may suffer from vaginal vault prolapse after hysterectomy due to weak support from lax apical ligaments. A decreased amount of estrogen and progesterone in older age is assumed to remodel the collagen thereby reducing tissue stiffness. Sacrocolpopexy is either performed as open or laparoscopic surgery using prosthetic mesh implants to substitute lax ligaments. Y-shaped mesh models (DynaMesh, Gynemesh, and Ultrapro) are implanted in a 3D female pelvic floor finite element model in the extraperitoneal space from the vaginal cuff to the first sacral (S1) bone below promontory. Numerical simulations are conducted during Valsalva maneuver with weakened tissues modeled by reduced tissue stiffness. Tissues are modeled as incompressible, isotropic hyperelastic materials whereas the meshes are modeled either as orthotropic linear elastic or as isotropic hyperlastic materials. The positions of the vaginal cuff and the bladder base are calculated from the pubococcygeal line for female pelvic floor at rest, for prolapse and after repair using the three meshes. Due to mesh mechanics and mesh pore deformation along the loaded direction, the DynaMesh with regular rectangular mesh pores is found to provide better mechanical support to the organs than the Gynemesh and the Ultrapro with irregular hexagonal mesh pores. Insbesondere {\"a}ltere, mehrgeb{\"a}hrende Frauen leiden h{\"a}ufiger an einem Scheidenvorfall nach einer Hysterektomie aufgrund der schwachen Unterst{\"u}tzung durch laxe apikale B{\"a}nder. Es wird angenommen, dass eine verringerte Menge an {\"O}strogen und Progesteron im h{\"o}heren Alter das Kollagen umformt, wodurch die Gewebesteifigkeit reduziert wird. Die Sakrokolpopexie ist eine offene oder laparoskopische Operation, die mit prothetischen Netzimplantaten durchgef{\"u}hrt wird, um laxe B{\"a}nder zu ersetzen. Y-f{\"o}rmige Netzmodelle (DynaMesh, Gynemesh und Ultrapro) werden in einem 3D-Modell des weiblichen Beckenbodens im extraperitonealen Raum vom Vaginalstumpf bis zum Promontorium implantiert. Numerische Simulationen werden w{\"a}hrend des Valsalva-Man{\"o}vers mit geschw{\"a}chtem Gewebe durchgef{\"u}hrt, das durch eine reduzierte Gewebesteifigkeit modelliert wird. Die Gewebe werden als inkompressible, isotrop hyperelastische Materialien modelliert, w{\"a}hrend die Netze entweder als orthotrope linear elastische oder als isotrope hyperlastische Materialien modelliert werden. Die Positionen des Vaginalstumpfs, der Blase und der Harnr{\"o}hrenachse werden anhand der Pubococcygeallinie aus der Ruhelage, f{\"u}r den Prolaps und nach der Reparatur unter Verwendung der drei Netze berechnet. Aufgrund der Netzmechanik und der Netzporenverformung bietet das DynaMesh mit regelm{\"a}ßigen rechteckigen Netzporen eine bessere mechanische Unterst{\"u}tzung und eine Neupositionierung des Scheidengew{\"o}lbes, der Blase und der Urethraachse als Gynemesh und Ultrapro mit unregelm{\"a}ßigen hexagonalen Netzporen.}, language = {en} } @article{BirgelLeschingerWegmannetal.2018, author = {Birgel, Stefan and Leschinger, Tim and Wegmann, Kilian and Staat, Manfred}, title = {Calculation of muscle forces and joint reaction loads in the shoulder area via an OpenSim based computer model}, series = {tm - Technisches Messen}, volume = {85}, journal = {tm - Technisches Messen}, number = {5}, publisher = {De Gruyter}, address = {Berlin}, issn = {2196-7113}, doi = {10.1515/teme-2017-0114}, pages = {321 -- 330}, year = {2018}, abstract = {Using the OpenSim software and verified anatomical data, a computer model for the calculation of biomechanical parameters is developed and used to determine the effect of a reattachment of the Supraspinatus muscle with a medial displacement of the muscle attachment point, which may be necessary for a rupture of the supraspinatus tendon. The results include the influence of the operation on basic biomechanical parameters such as the lever arm, as well as the calculated the muscle activations for the supraspinatus and deltoid. In addition, the influence on joint stability is examined by an analysis of the joint reaction force. The study provides a detailed description of the used model, as well as medical findings to a reattachment of the supraspinatus. Mit der Software OpenSim und {\"u}berpr{\"u}ften anatomischen Daten wird ein Computermodell zur Berechnung von biomechanischen Parametern entwickelt und genutzt, um den Effekt einer Refixierung des Supraspinatusmuskels mit einer medialen Verschiebung des Muskelansatzpunktes zu ermitteln, wie sie unter anderem nach einem Riss der Supraspinatussehne notwendig sein kann. Die Ergebnisse umfassen hierbei den Einfluss der Operation auf grundlegende biomechanische Parameter wie den Hebelarm sowie die berechneten Muskelaktivierungen f{\"u}r den Supraspinatus und Deltoideus. Zus{\"a}tzlich wird der Einfluss auf die Gelenkstabilit{\"a}t betrachtet und durch eine Analyse der Gelenkreaktionskraft untersucht. Die Studie bietet eine detaillierte Beschreibung des genutzten Modells, sowie medizinische Erkenntnisse zu einer Refixierung des Supraspinatus.}, language = {en} } @inproceedings{HansenLaack2018, author = {Hansen, Frank and Laack, Walter van}, title = {Schnittstelle Tod: Sind Religionen religi{\"o}s und Wissenschaften wissend?}, publisher = {van Laack GmbH}, address = {Aachen}, isbn = {978-3-936624-36-6}, pages = {172 S.}, year = {2018}, language = {de} } @article{MolinnusHardtSiegertetal.2018, author = {Molinnus, Denise and Hardt, Gabriel and Siegert, Petra and Willenberg, Holger S. and Poghossian, Arshak and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Detection of Adrenaline in Blood Plasma as Biomarker for Adrenal Venous Sampling}, series = {Electroanalysis}, volume = {30}, journal = {Electroanalysis}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1521-4109}, doi = {10.1002/elan.201800026}, pages = {937 -- 942}, year = {2018}, abstract = {An amperometric bi-enzyme biosensor based on substrate recycling principle for the amplification of the sensor signal has been developed for the detection of adrenaline in blood. Adrenaline can be used as biomarker verifying successful adrenal venous sampling procedure. The adrenaline biosensor has been realized via modification of a galvanic oxygen sensor with a bi-enzyme membrane combining a genetically modified laccase and a pyrroloquinoline quinone-dependent glucose dehydrogenase. The measurement conditions such as pH value and temperature were optimized to enhance the sensor performance. A high sensitivity and a low detection limit of about 0.5-1 nM adrenaline have been achieved in phosphate buffer at pH 7.4, relevant for measurements in blood samples. The sensitivity of the biosensor to other catecholamines such as noradrenaline, dopamine and dobutamine has been studied. Finally, the sensor has been successfully applied for the detection of adrenaline in human blood plasma.}, language = {en} } @inproceedings{HueningHeuermannWache2018, author = {H{\"u}ning, Felix and Heuermann, Holger and Wache, Franz-Josef}, title = {Wireless CAN}, series = {Tagungsband AALE 2018 : das Forum f{\"u}r Fachleute der Automatisierungstechnik aus Hochschulen und Wirtschaft ; 15. Fachkonferenz, Regensburg ; [15. Konferenz f{\"u}r Angewandte Automatisierungstechnik in Lehre und Entwicklung / TH K{\"o}ln; VFAALE, Verein der Freunde und F{\"o}rderer der Angewandten Automatisierungstechnik]}, booktitle = {Tagungsband AALE 2018 : das Forum f{\"u}r Fachleute der Automatisierungstechnik aus Hochschulen und Wirtschaft ; 15. Fachkonferenz, Regensburg ; [15. Konferenz f{\"u}r Angewandte Automatisierungstechnik in Lehre und Entwicklung / TH K{\"o}ln; VFAALE, Verein der Freunde und F{\"o}rderer der Angewandten Automatisierungstechnik]}, publisher = {VDE Verlag}, pages = {135 -- 144}, year = {2018}, abstract = {Das vorgestellte System zu Wireless CAN bietet die M{\"o}glichkeit, CAN kabellos zu {\"u}bertragen. Beide vorgestellten und entwickelten Konzepte funktionieren korrekt und erm{\"o}glichen den Auf-bau von kabellosen CAN Schnittstellen. Durch den kleinen Aufbau kann diese Technologie auch f{\"u}r eingebettete Systeme verwendet werden. Zudem bietet dieser Ansatz die M{\"o}glichkeit, durch die Entwicklung von geeigneten ICs die Gr{\"o}ße des Systems bis auf Bauteilgr{\"o}ße zu reduzieren, um eine noch bessere Integration in eingebettete Systeme zu erm{\"o}glichen. Dadurch wird die Technologie attraktiv f{\"u}r Einsatzgebiete, wo die oben aufgelisteten Vorteile zum Tragen kommen k{\"o}nnen. Diese Einsatzgebiete k{\"o}nnen sowohl im Automobil als auch im Industriebereich liegen.}, language = {de} } @article{OberlaenderMayerGreeffetal.2018, author = {Oberl{\"a}nder, Jan and Mayer, Marlena and Greeff, Anton and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Spore-based biosensor to monitor the microbicidal efficacy of gaseous hydrogen peroxide sterilization processes}, series = {Biosensors and Bioelectronics}, volume = {104}, journal = {Biosensors and Bioelectronics}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0956-5663}, doi = {10.1016/j.bios.2017.12.045}, pages = {87 -- 94}, year = {2018}, abstract = {In this work, a spore-based biosensor is evaluated to monitor the microbicidal efficacy of sterilization processes applying gaseous hydrogen peroxide (H2O2). The sensor is based on interdigitated electrode structures (IDEs) that have been fabricated by means of thin-film technologies. Impedimetric measurements are applied to study the effect of sterilization process on spores of Bacillus atrophaeus. This resilient microorganism is commonly used in industry to proof the sterilization efficiency. The sensor measurements are accompanied by conventional microbiological challenge tests, as well as morphological characterizations with scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The sensor measurements are correlated with the microbiological test routines. In both methods, namely the sensor-based and microbiological one, a tailing effect has been observed. The results are evaluated and discussed in a three-dimensional calibration plot demonstrating the sensor's suitability to enable a rapid process decision in terms of a successfully performed sterilization.}, language = {en} } @incollection{BhattaraiFrotscherStaat2018, author = {Bhattarai, Aroj and Frotscher, Ralf and Staat, Manfred}, title = {Computational Analysis of Pelvic Floor Dysfunction}, series = {Women's Health and Biomechanics}, booktitle = {Women's Health and Biomechanics}, publisher = {Springer}, address = {Cham}, isbn = {978-3-319-71574-2}, doi = {10.1007/978-3-319-71574-2_17}, pages = {217 -- 230}, year = {2018}, abstract = {Pelvic floor dysfunction (PFD) is characterized by the failure of the levator ani (LA) muscle to maintain the pelvic hiatus, resulting in the descent of the pelvic organs below the pubococcygeal line. This chapter adopts the modified Humphrey material model to consider the effect of the muscle fiber on passive stretching of the LA muscle. The deformation of the LA muscle subjected to intra-abdominal pressure during Valsalva maneuver is compared with the magnetic resonance imaging (MRI) examination of a nulliparous female. Numerical result shows that the fiber-based Humphrey model simulates the muscle behavior better than isotropic constitutive models. Greater posterior movement of the LA muscle widens the levator hiatus due to lack of support from the anococcygeal ligament and the perineal structure as a consequence of birth-related injury and aging. Old and multiparous females with uncontrolled urogenital and rectal hiatus tend to develop PFDs such as prolapse and incontinence.}, language = {en} }