@article{WernerWagnerMiyamotoetal.2012, author = {Werner, Frederik and Wagner, Torsten and Miyamoto, Ko-ichiro and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {High speed and high resolution chemical imaging based on a new type of OLED-LAPS set-up}, series = {Sensors and Actuators B: Chemical}, volume = {175}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2011.12.102}, pages = {118 -- 122}, year = {2012}, abstract = {Light-addressable potentiometric sensors (LAPS) are field-effect-based sensors. A modulated light source is used to define the particular measurement spot to perform spatially resolved measurements of chemical species and to generate chemical images. In this work, an organic-LED (OLED) display has been chosen as a light source. This allows high measurement resolution and miniaturisation of the system. A new developed driving method for the OLED display optimised for LAPS-based measurements is demonstrated. The new method enables to define modulation frequencies between 1 kHz and 16 kHz and hence, reduces the measurement time of a chemical image by a factor of 40 compared to the traditional addressing of an OLED display.}, language = {en} } @article{WagnerWernerMiyamotoetal.2012, author = {Wagner, Torsten and Werner, Frederik and Miyamoto, Ko-Ichiro and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Development and characterisation of a compact light-addressable potentiometric sensor (LAPS) based on the digital light processing (DLP) technology for flexible chemical imaging}, series = {Sensors and Actuators B: Chemical}, volume = {170}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2010.12.003}, pages = {34 -- 39}, year = {2012}, abstract = {Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach to read out light-addressable potentiometric sensors (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device, which allows fast and flexible generation of light patterns. With the help of these light patterns, the sensor surface of the LAPS device can be addressed. The DLP approach has several advantages compared to conventional LAPS set-ups, e.g., the spot size and the shape of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of the measurement. In addition, the modulation frequency and intensity of the light beam are important parameters of the LAPS set-up. Within this work, the authors will discuss two different ways of light modulation by the DLP set-up, investigate the influence of different modulation frequencies and different light intensities as well as demonstrate the scanning capabilities of the new set-up by pH mapping on the sensor surface.}, language = {en} } @incollection{Vismann2012, author = {Vismann, Ulrich}, title = {Stahlbeton- und Spannbetonbau nach Eurocode 2}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_12}, pages = {601 -- 775}, year = {2012}, abstract = {Die bauaufsichtliche Einf{\"u}hrung der Eurocodes steht unmittelbar bevor. F{\"u}r den Bereich des Stahl- und Spannbetonbaus soll die Anwendung zum 1. Juli 2012 verbindlich sein, d. h. mit diesem Stichtag sollte nur noch der Eurocode 2 (DIN EN 1992-1-1, Ausgabe Januar 2011) mit seinem zugeh{\"o}rigen nationalen Anhang (DIN EN 1992-1-1/NA, Ausgabe Januar 2011) Verwendung finden, die DIN 1045-1 wird zur{\"u}ckgezogen. Bereits seit M{\"a}rz 2010 gilt eine {\"U}bergangsphase, ist der die Anwendung des Eurocodes alternativ zur DIN 1045-1 als bauaufsichtlich gleichwertige L{\"o}sung m{\"o}glich.}, language = {de} } @incollection{Vismann2012, author = {Vismann, Ulrich}, title = {Beton nach DIN 1045-2}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_11}, pages = {571 -- 600}, year = {2012}, language = {de} } @incollection{Feiser2012, author = {Feiser, Johannes}, title = {Geotechnik}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_17}, pages = {1221 -- 1332}, year = {2012}, abstract = {In der nationalen und der europ{\"a}ischen Normung werden die geotechnischen Aufgaben zwecks Mindestanforderungen an Baugrunduntersuchung, rechnerische Nachweise und {\"U}berwachung der Ausf{\"u}hrung in drei Klassen (Kategorien) eingeteilt. Sie richten sich nach der zu erwartenden Reaktion des Baugrundes, nach dem geotechnischen Schwierigkeitsgrad des Tragwerks und seiner Einfl{\"u}sse auf dieUmgebung.}, language = {de} } @incollection{Strohmeier2012, author = {Strohmeier, Andreas}, title = {Siedlungswasserwirtschaft}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_19}, pages = {1393 -- 1498}, year = {2012}, language = {de} } @incollection{Biener2012, author = {Biener, Ernst}, title = {Abfallwirtschaft}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_20}, pages = {1499 -- 1540}, year = {2012}, language = {de} } @book{Schmitz2012, author = {Schmitz, G{\"u}nter}, title = {Elektronik im Kraftfahrzeug : Innovationen bei System und Komponenten ; mit 7 Tabellen / Hrsg.: Schmitz, G{\"u}nter}, publisher = {expert-Verl.}, address = {Renningen}, isbn = {978-3-8169-3110-2}, pages = {185 S. : Ill., graph. Darst.}, year = {2012}, language = {de} } @book{Vismann2012, author = {Vismann, Ulrich}, title = {Wendehorst Bautechnische Zahlentafeln / hrsg. von Ulrich Vismann in Verbindung mit dem DIN Deutsches Institut f{\"u}r Normung e.V. Herwig Baumgartner ...}, edition = {34., vollst. {\"u}berarb. und erw. Aufl.}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2}, pages = {1688 S. : graph. Darst.}, year = {2012}, language = {de} } @article{MiyamotoKanekoMatsuoetal.2012, author = {Miyamoto, Ko-ichiro and Kaneko, Kazumi and Matsuo, Akira and Wagner, Torsten and Kanoh, Shin{\´i}chiro and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Miniaturized chemical imaging sensor system using an OLED display panel}, series = {Sensors and Actuators B: Chemical}, volume = {170}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2011.02.029}, pages = {82 -- 87}, year = {2012}, abstract = {The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the current-voltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated.}, language = {en} }