@article{Fabo2002, author = {Fabo, Sabine}, title = {Welcome to the training: Actionist Respoke interaktiv by Michael Jonoschek und R{\"u}diger Schl{\"o}mer}, series = {Bilder-Codes : Internationaler Medienkunstpreis 2002}, journal = {Bilder-Codes : Internationaler Medienkunstpreis 2002}, editor = {K{\"o}nches, Barbara}, publisher = {ZKM}, address = {Karlsruhe}, isbn = {3-928201-28-X}, pages = {41 -- 48}, year = {2002}, language = {en} } @article{Krause2006, author = {Krause, Thomas}, title = {Bauabrechnung und Mengenermittlung}, series = {Beispiele f{\"u}r die Baubetriebspraxis / Hoffmann, Manfred ; Kuhlmann, Willy [Hrsg.].}, journal = {Beispiele f{\"u}r die Baubetriebspraxis / Hoffmann, Manfred ; Kuhlmann, Willy [Hrsg.].}, publisher = {Teubner}, address = {Wiesbaden}, isbn = {978-3-8351-0002-2}, pages = {49 -- 62}, year = {2006}, language = {de} } @article{BaeckerRakowskiPoghossianetal.2013, author = {B{\"a}cker, Matthias and Rakowski, D. and Poghossian, Arshak and Biselli, Manfred and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Chip-based amperometric enzyme sensor system for monitoring of bioprocesses by flow-injection analysis}, series = {Journal of Biotechnology}, volume = {163}, journal = {Journal of Biotechnology}, number = {4}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0168-1656}, doi = {10.1016/j.jbiotec.2012.03.014}, pages = {371 -- 376}, year = {2013}, abstract = {A microfluidic chip integrating amperometric enzyme sensors for the detection of glucose, glutamate and glutamine in cell-culture fermentation processes has been developed. The enzymes glucose oxidase, glutamate oxidase and glutaminase were immobilized by means of cross-linking with glutaraldehyde on platinum thin-film electrodes integrated within a microfluidic channel. The biosensor chip was coupled to a flow-injection analysis system for electrochemical characterization of the sensors. The sensors have been characterized in terms of sensitivity, linear working range and detection limit. The sensitivity evaluated from the respective peak areas was 1.47, 3.68 and 0.28 μAs/mM for the glucose, glutamate and glutamine sensor, respectively. The calibration curves were linear up to a concentration of 20 mM glucose and glutamine and up to 10 mM for glutamate. The lower detection limit amounted to be 0.05 mM for the glucose and glutamate sensor, respectively, and 0.1 mM for the glutamine sensor. Experiments in cell-culture medium have demonstrated a good correlation between the glutamate, glutamine and glucose concentrations measured with the chip-based biosensors in a differential-mode and the commercially available instrumentation. The obtained results demonstrate the feasibility of the realized microfluidic biosensor chip for monitoring of bioprocesses.}, language = {en} } @article{HuckPoghossianWagneretal.2012, author = {Huck, Christina and Poghossian, Arshak and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Combined amperometric/field-effect sensor for the detection of dissolved hydrogen}, series = {Sensors and actuators B: Chemical}, volume = {187}, journal = {Sensors and actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2012.10.050}, pages = {168 -- 173}, year = {2012}, abstract = {Real-time and reliable monitoring of the biogas process is crucial for a stable and efficient operation of biogas production in order to avoid digester breakdowns. The concentration of dissolved hydrogen (H₂) represents one of the key parameters for biogas process control. In this work, a one-chip integrated combined amperometric/field-effect sensor for monitoring the dissolved H₂ concentration has been developed for biogas applications. The combination of two different transducer principles might allow a more accurate and reliable measurement of dissolved H₂ as an early warning indicator of digester failures. The feasibility of the approach has been demonstrated by simultaneous amperometric/field-effect measurements of dissolved H₂ concentrations in electrolyte solutions. Both, the amperometric and the field-effect transducer show a linear response behaviour in the H₂ concentration range from 0.1 to 3\% (v/v) with a slope of 198.4 ± 13.7 nA/\% (v/v) and 14.9 ± 0.5 mV/\% (v/v), respectively.}, language = {en} } @article{PoghossianMaiMourzinaetal.2004, author = {Poghossian, Arshak and Mai, D.-T. and Mourzina, Y. and Sch{\"o}ning, Michael Josef}, title = {Impedance effect of an ion-sensitive membrane: characterisation of an EMIS sensor by impedance spectroscopy, capacitance-voltage and constant-capacitance method}, series = {Sensors and Actuators B. 103 (2004), H. 1-2}, journal = {Sensors and Actuators B. 103 (2004), H. 1-2}, isbn = {0925-4005}, pages = {423 -- 428}, year = {2004}, language = {en} } @article{HeuermannSadeghfam2008, author = {Heuermann, Holger and Sadeghfam, Arash}, title = {Electrically tunable bandpass filter with integrated carrier suppression for UHF RFID systems / Sadeghfam, Arash ; Heuermann, Holger}, series = {European Conference on Wireless Technology, 2008. EuWiT 2008.}, journal = {European Conference on Wireless Technology, 2008. EuWiT 2008.}, isbn = {978-2-87487-008-8}, pages = {306 -- 309}, year = {2008}, language = {en} } @article{UllrichGrottkeRossaintetal.2010, author = {Ullrich, Sebastian and Grottke, Oliver and Rossaint, Rolf and Staat, Manfred and Deserno, Thomas M. and Kuhlen, Torsten}, title = {Virtual Needle Simulation with Haptics for Regional Anaesthesia}, pages = {1 -- 3}, year = {2010}, language = {en} } @article{Heuermann2008, author = {Heuermann, Holger}, title = {Calibration of a Network Analyzer Without a Thru Connection for Nonlinear and Multiport Measurements}, series = {IEEE Transactions on Microwave Theory and Techniques. 56 (2008), H. 11, 1}, journal = {IEEE Transactions on Microwave Theory and Techniques. 56 (2008), H. 11, 1}, isbn = {0018-9480}, pages = {2505 -- 2510}, year = {2008}, language = {en} } @article{SchoeningPoghossian2009, author = {Sch{\"o}ning, Michael Josef and Poghossian, Arshak}, title = {Silicon-based field-effect devices with nanostructured surfaces for bio-/chemical sensing}, series = {Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009}, journal = {Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009}, pages = {51 -- 53}, year = {2009}, language = {en} } @article{RauAlexopoulosBreitbachetal.2014, author = {Rau, Christoph and Alexopoulos, Spiros and Breitbach, Gerd and Hoffschmidt, Bernhard and Latzke, Markus and Sattler, Johannes Christoph}, title = {Transient simulation of a solar-hybrid tower power plant with open volumetric receiver at the location Barstow}, series = {Energy procedia : proceedings of the SolarPACES 2013 International Conference}, volume = {49}, journal = {Energy procedia : proceedings of the SolarPACES 2013 International Conference}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1876-6102}, doi = {10.1016/j.egypro.2014.03.157}, pages = {1481 -- 1490}, year = {2014}, abstract = {In this work the transient simulations of four hybrid solar tower power plant concepts with open-volumetric receiver technology for a location in Barstow-Daggett, USA, are presented. The open-volumetric receiver uses ambient air as heat transfer fluid and the hybridization is realized with a gas turbine. The Rankine cycle is heated by solar-heated air and/or by the gas turbine's flue gases. The plant can be operated in solar-only, hybrid parallel or combined cycle-only mode as well as in any intermediate load levels where the solar portion can vary between 0 to 100\%. The simulated plant is based on the configuration of a solar-hybrid power tower project, which is in planning for a site in Northern Algeria. The meteorological data for Barstow-Daggett was taken from the software meteonorm. The solar power tower simulation tool has been developed in the simulation environment MATLAB/Simulink and is validated.}, language = {en} }