@article{FrauenrathHezelRenzetal.2010, author = {Frauenrath, Tobias and Hezel, Fabian and Renz, Wolfgang and de Geyer d'Orth, Thibaut and Dieringer, Matthias and von Knobelsdorf-Brenkenhoff, Florian and Prothmann, Marcel and Schulz-Menger, Jeanette and Niendorf, Thoralf}, title = {Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla}, series = {Journal of Cardiovascular Magnetic Resonance}, volume = {12}, journal = {Journal of Cardiovascular Magnetic Resonance}, number = {1}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1532-429X}, doi = {10.1186/1532-429X-12-67}, year = {2010}, abstract = {Background To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oximetry (POX) triggered 2D CINE acquisitions together with (i) a qualitative image quality analysis, (ii) an assessment of the left ventricular function parameter and (iii) an examination of trigger reliability and trigger detection variance derived from the signal waveforms. Results ECG was susceptible to severe distortions at 7.0 T. POX and ACT provided waveforms free of interferences from electromagnetic fields or from magneto-hydrodynamic effects. Frequent R-wave mis-registration occurred in ECG-triggered acquisitions with a failure rate of up to 30\% resulting in cardiac motion induced artifacts. ACT and POX triggering produced images free of cardiac motion artefacts. ECG showed a severe jitter in the R-wave detection. POX also showed a trigger jitter of approximately Δt = 72 ms which is equivalent to two cardiac phases. ACT showed a jitter of approximately Δt = 5 ms only. ECG waveforms revealed a standard deviation for the cardiac trigger offset larger than that observed for ACT or POX waveforms. Image quality assessment showed that ACT substantially improved image quality as compared to ECG (image quality score at end-diastole: ECG = 1.7 ± 0.5, ACT = 2.4 ± 0.5, p = 0.04) while the comparison between ECG vs. POX gated acquisitions showed no significant differences in image quality (image quality score: ECG = 1.7 ± 0.5, POX = 2.0 ± 0.5, p = 0.34). Conclusions The applicability of acoustic triggering for cardiac CINE imaging at 7.0 T was demonstrated. ACT's trigger reliability and fidelity are superior to that of ECG and POX. ACT promises to be beneficial for cardiovascular magnetic resonance at ultra-high field strengths including 7.0 T.}, language = {en} } @article{MartinFrauenrathOezerdemetal.2011, author = {Martin, Conrad and Frauenrath, Tobias and {\"O}zerdem, Celal and Renz, Wolfgang and Niendorf, Thoralf}, title = {Development and evaluation of a small and mobile Magneto Alert Sensor (MALSE) to support safety requirements for magnetic resonance imaging}, series = {European Radiology}, volume = {21}, journal = {European Radiology}, publisher = {Springer}, address = {Berlin, Heidelberg}, issn = {1432-1084}, doi = {10.1007/s00330-011-2153-z}, pages = {2187 -- 2192}, year = {2011}, abstract = {Objective The purpose of this study is to (i) design a small and mobile Magnetic field ALert SEnsor (MALSE), (ii) to carefully evaluate its sensors to their consistency of activation/deactivation and sensitivity to magnetic fields, and (iii) to demonstrate the applicability of MALSE in 1.5 T, 3.0 T and 7.0 T MR fringe field environments. Methods MALSE comprises a set of reed sensors, which activate in response to their exposure to a magnetic field. The activation/deactivation of reed sensors was examined by moving them in/out of the fringe field generated by 7TMR. Results The consistency with which individual reed sensors would activate at the same field strength was found to be 100\% for the setup used. All of the reed switches investigated required a substantial drop in ambient magnetic field strength before they deactivated. Conclusions MALSE is a simple concept for alerting MRI staff to a ferromagnetic object being brought into fringe magnetic fields which exceeds MALSEs activation magnetic field. MALSE can easily be attached to ferromagnetic objects within the vicinity of a scanner, thus creating a barrier for hazardous situations induced by ferromagnetic parts which should not enter the vicinity of an MR-system to occur.}, language = {en} } @misc{CapitainLukebaUlberetal.2018, author = {Capitain, C. C. and Lukeba, L. and Ulber, Roland and Tippk{\"o}tter, Nils}, title = {Biomimetische Klebstoffe aus Organosolv-Lignin}, series = {Chemie Ingenieur Technik}, volume = {90}, journal = {Chemie Ingenieur Technik}, number = {9}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.201855076}, pages = {1167}, year = {2018}, abstract = {Aufgrund von EU-Regularien und Umweltinitiativen w{\"a}chst der Markt f{\"u}r nachhaltige und abbaubare Klebstoffe stetig. Organosolv (OS)-Lignin ist ein kommerziell wenig ertragreicher Nebenstrom der Lignocellulose-Bioraffinerie. Durch das "Nachahmen" der Adh{\"a}sionseigenschaften mit strukturverwandten Muschel-Aminos{\"a}uren soll OS-Lignin in einen starkes, vollst{\"a}ndig biobasiertes Adh{\"a}siv umgewandelt werden. Funktionsweisend f{\"u}r die Adh{\"a}sion des Muschelklebstoffes ist die Catecholgruppe der Aminos{\"a}ure L-DOPA. Die laccase-katalysierte Polymerisationsreaktion von Lignin und L-DOPA ist schwierig zu kontrollieren, da L-DOPA eine Ringschlussreaktion eingeht. Stattdessen wurde eine zweistufige Reaktion mit einem Diamin als Ankermolek{\"u}l etabliert. Die Catecholgruppe, die im zweiten Schritt enzymatisch an das Lignin-Amin gebunden wird, kann durch Komplexbildung mit Fe(III)-Ionen sowohl zur Adh{\"a}sion als auch zur Koh{\"a}sion des Klebstoffes beitragen. Der Lignin-Catechol-Klebstoff ist frei von petrochemischen Chemikalien und biologisch abbaubar. In ersten Stirnzugversuchen konnte eine Haftkraft von 0,3 MPa erreicht werden.}, language = {de} } @article{Gaigall2021, author = {Gaigall, Daniel}, title = {Test for Changes in the Modeled Solvency Capital Requirement of an Internal Risk Model}, series = {ASTIN Bulletin}, volume = {51}, journal = {ASTIN Bulletin}, number = {3}, publisher = {Cambridge Univ. Press}, address = {Cambridge}, issn = {1783-1350}, doi = {10.1017/asb.2021.20}, pages = {813 -- 837}, year = {2021}, abstract = {In the context of the Solvency II directive, the operation of an internal risk model is a possible way for risk assessment and for the determination of the solvency capital requirement of an insurance company in the European Union. A Monte Carlo procedure is customary to generate a model output. To be compliant with the directive, validation of the internal risk model is conducted on the basis of the model output. For this purpose, we suggest a new test for checking whether there is a significant change in the modeled solvency capital requirement. Asymptotic properties of the test statistic are investigated and a bootstrap approximation is justified. A simulation study investigates the performance of the test in the finite sample case and confirms the theoretical results. The internal risk model and the application of the test is illustrated in a simplified example. The method has more general usage for inference of a broad class of law-invariant and coherent risk measures on the basis of a paired sample.}, language = {en} } @article{DerschGeyerHerrmannetal.2004, author = {Dersch, J{\"u}rgen and Geyer, Michael and Herrmann, Ulf and Jones, Scott A. and Kelly, Bruce and Kistner, Rainer and Ortmanns, Winfried and Pitz-Paal, Robert and Price, Henry}, title = {Trough integration into power plants—a study on the performance and economy of integrated solar combined cycle systems}, series = {Energy : the international journal}, volume = {29}, journal = {Energy : the international journal}, number = {5-6 (Special Issue SolarPaces)}, issn = {0360-5442}, doi = {10.1016/S0360-5442(03)00199-3}, pages = {947 -- 959}, year = {2004}, language = {en} } @techreport{DammAnthrakidisFend2015, author = {Damm, Marc Andr{\´e} and Anthrakidis, Anette and Fend, Thomas}, title = {Partikelminderungssystem mit einstellbarem Partikelr{\"u}ckhaltegrad : Varytrap : Schlussbericht : Laufzeit: 01.07.2010-28.02.2014}, address = {J{\"u}lich}, doi = {10.2314/GBV:848651863}, pages = {1 Online-Ressource (44 Seiten)}, year = {2015}, language = {de} } @techreport{Benner1982, author = {Benner, Joachim}, title = {Dynamisches Verhalten drehelastischer Kupplungen unter Ber{\"u}cksichtigung allgemeiner Materialgleichungen und Einbeziehung von Ausfallkriterien : Literaturrecherche; Berichtszeitraum 1981 - 1982. - (Forschungsheft / Forschungsvereinigung Antriebstechnik e.V. ; 132)}, publisher = {Forschungsvereinigung Antriebstechnik e.V.}, address = {Frankfurt/M.}, pages = {113 S. : zahlr. Ill.}, year = {1982}, language = {de} } @incollection{Fabo2022, author = {Fabo, Sabine}, title = {Pandemische Momente}, series = {Interaktion - Emotion - Desinfektion ; Kunst und Museum in Zeiten von Corona / Birgit Richard, Jana M{\"u}ller, Niklas von Reischach (Hrsg.)}, booktitle = {Interaktion - Emotion - Desinfektion ; Kunst und Museum in Zeiten von Corona / Birgit Richard, Jana M{\"u}ller, Niklas von Reischach (Hrsg.)}, publisher = {Campus}, address = {Frankfurt ; New York}, isbn = {978-3-593-51520-5 (Print)}, pages = {137 -- 140}, year = {2022}, language = {de} } @book{Laack2019, author = {Laack, Walter van}, title = {Weltbilder gestern und heute - Was bleibt und wor{\"u}ber lacht man morgen?}, series = {Vortr{\"a}ge \& Einsichten, Lectures \& Insights}, journal = {Vortr{\"a}ge \& Einsichten, Lectures \& Insights}, number = {Band 2}, publisher = {van Laack Buchverlag}, address = {Aachen}, isbn = {ISBN 978-3936624-44-1}, pages = {56 Seiten}, year = {2019}, language = {de} } @misc{TippkoetterStaubSohlingetal.2012, author = {Tippk{\"o}tter, Nils and Staub, C. and Sohling, U. and Ruf, N. and Ulber, Roland}, title = {Adsorptive Aufreinigung von Molkeproteinen}, series = {Chemie Ingenieur Technik}, volume = {84}, journal = {Chemie Ingenieur Technik}, number = {8}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.201250395}, pages = {1285}, year = {2012}, abstract = {In der Molkeverarbeitung dominieren Membranfiltrationsverfahren die Prozessf{\"u}hrung. Hierbei werden {\"u}blicherweise Aufkonzentrierungen der Proteine und deren Trennung von dem Milchzucker Lactose durchgef{\"u}hrt. Der Prozess der adsorptiven Aufreinigung soll als kosteng{\"u}nstige Alternative zu den bisher gebr{\"a}uchlichen Verfahren dienen. Weiterhin er{\"o}ffnet sich durch das Verfahren die M{\"o}glichkeit, einzelne Proteinfraktionen w{\"a}hrend der Verarbeitung anzureichern. Als Proteinquellen wurden f{\"u}r die Untersuchungen Modellproteine, L{\"o}sungen aus Molkenproteinisolat, D{\"u}nnmolke und Molkekonzentrat verwendet. Die Eignung zur Proteinbindung wurden an Tonmaterialien, Silicaten und y-Aluminiumoxiden in Pulverform, in Form von Granulaten sowie Extrudaten als auch sph{\"a}rischen Partikeln {\"u}berpr{\"u}ft. Adsorbentien aus Bentonit/Silica und c-Aluminiumoxid k{\"o}nnen sowohl a-Lactalbumin (aLA) als auch b-Lactoglobulin (bLG) binden, wohingegen Materialien aus Siliciumoxid lediglich ein starkes Adsorptionsverhalten gegen{\"u}ber bLG zeigen. Mischmaterialien aus Siliciumoxid und a-Aluminiumoxid zeigen dasselbe Verhalten wie Materialien aus Siliciumoxid, weisen jedoch eine geringere Kapazit{\"a}t auf. Die Materialen wurden hinsichtlich ihres Einsatzes in chromatographischen Verfahren und Batch-Prozessen untersucht und ein Prozessentwurf f{\"u}r einen zweistufigen Batch-Prozess im R{\"u}hrkessel erarbeitet.}, language = {de} }