@inproceedings{Bung2009, author = {Bung, Daniel Bernhard}, title = {Optimierung des potentiellen Sauerstoffeintrags auf Treppenschussrinnen mit gem{\"a}ßigter Neigung}, series = {9. JuWi-Treffen : Beitr{\"a}ge zum Treffen junger Wissenschaftlerinnen und junger Wissenschaftler deutschsprachiger Wasserbauinstitute}, booktitle = {9. JuWi-Treffen : Beitr{\"a}ge zum Treffen junger Wissenschaftlerinnen und junger Wissenschaftler deutschsprachiger Wasserbauinstitute}, editor = {Theobald, S.}, publisher = {Universit{\"a}t Kassel}, address = {Kassel}, pages = {73 -- 78}, year = {2009}, language = {de} } @inproceedings{BungValero2017, author = {Bung, Daniel Bernhard and Valero, Daniel}, title = {FlowCV - An open-source toolbox for computer vision applications in turbulent flows}, series = {Proceedings of the 37th IAHR World Congress August 13 - 18, 2017, Kuala Lumpur, Malaysia}, booktitle = {Proceedings of the 37th IAHR World Congress August 13 - 18, 2017, Kuala Lumpur, Malaysia}, issn = {2521-716X}, pages = {5356 -- 5365}, year = {2017}, language = {en} } @article{BungErpicumTullis2020, author = {Bung, Daniel Bernhard and Erpicum, S{\´e}bastien and Tullis, Blanke P.}, title = {Advances in hydraulic structures engineering}, series = {Journal of Hydraulic Engineering}, volume = {147}, journal = {Journal of Hydraulic Engineering}, number = {1}, publisher = {ASCE}, address = {Reston, Va.}, issn = {0733-9429 (Druckausgabe)}, doi = {10.1061/(ASCE)HY.1943-7900.0001851}, pages = {1 Seite}, year = {2020}, language = {en} } @article{Bung2011, author = {Bung, Daniel Bernhard}, title = {Fließcharakteristik und Sauerstoffeintrag bei selbstbel{\"u}fteten Gerinnestr{\"o}mungen auf Kaskaden mit gem{\"a}ßigter Neigung}, series = {{\"O}sterreichische Wasser- und Abfallwirtschaft}, volume = {Vol. 63}, journal = {{\"O}sterreichische Wasser- und Abfallwirtschaft}, number = {Iss. 3-4}, publisher = {Springer}, address = {Berlin}, issn = {1613-7566 (E-Journal); 0945-358X (Print)}, pages = {76 -- 81}, year = {2011}, language = {de} } @article{ValeroChansonBung2019, author = {Valero, Daniel and Chanson, Hubert and Bung, Daniel Bernhard}, title = {Robust estimators for turbulence properties assessment}, pages = {1 -- 24}, year = {2019}, language = {en} } @inproceedings{Bung2012, author = {Bung, Daniel Bernhard}, title = {Sensitivity of phase detection techniques in aerated chute flows to hydraulic design parameters}, series = {2nd European IAHR congress : 27. - 29. June 2012, M{\"u}nchen}, booktitle = {2nd European IAHR congress : 27. - 29. June 2012, M{\"u}nchen}, publisher = {Lehrstuhl u. Versuchsanst. f{\"u}r Wasserbau u. Wasserwirtschaft d. TU M{\"u}nchen}, address = {M{\"u}nchen}, organization = {International Association for Hydraulic Engineering and Research}, isbn = {978-3-943683-03-5}, pages = {Artikelkennnummer: B15}, year = {2012}, language = {en} } @article{HagenkampBlankeDoering2021, author = {Hagenkamp, Markus and Blanke, Tobias and D{\"o}ring, Bernd}, title = {Thermoelectric building temperature control: a potential assessment}, series = {International Journal of Energy and Environmental Engineering}, volume = {13}, journal = {International Journal of Energy and Environmental Engineering}, publisher = {Springer}, address = {Berlin}, doi = {10.1007/s40095-021-00424-x}, pages = {241 -- 254}, year = {2021}, abstract = {This study focuses on thermoelectric elements (TEE) as an alternative for room temperature control. TEE are semi-conductor devices that can provide heating and cooling via a heat pump effect without direct noise emissions and no refrigerant use. An efficiency evaluation of the optimal operating mode is carried out for different numbers of TEE, ambient temperatures, and heating loads. The influence of an additional heat recovery unit on system efficiency and an unevenly distributed heating demand are examined. The results show that TEE can provide heat at a coefficient of performance (COP) greater than one especially for small heating demands and high ambient temperatures. The efficiency increases with the number of elements in the system and is subject to economies of scale. The best COP exceeds six at optimal operating conditions. An additional heat recovery unit proves beneficial for low ambient temperatures and systems with few TEE. It makes COPs above one possible at ambient temperatures below 0 ∘C. The effect increases efficiency by maximal 0.81 (from 1.90 to 2.71) at ambient temperature 5 K below room temperature and heating demand Q˙h=100W but is subject to diseconomies of scale. Thermoelectric technology is a valuable option for electricity-based heat supply and can provide cooling and ventilation functions. A careful system design as well as an additional heat recovery unit significantly benefits the performance. This makes TEE superior to direct current heating systems and competitive to heat pumps for small scale applications with focus on avoiding noise and harmful refrigerants.}, language = {en} } @article{KerpenBungValeroetal.2017, author = {Kerpen, Nils B. and Bung, Daniel Bernhard and Valero, Daniel and Schlurmann, Torsten}, title = {Energy dissipation within the wave run-up at stepped revetments}, series = {Journal of Ocean University of China}, volume = {16}, journal = {Journal of Ocean University of China}, number = {4}, publisher = {Springer}, address = {Berlin}, issn = {1993-5021}, doi = {10.1007/s11802-017-3355-z}, pages = {649 -- 654}, year = {2017}, language = {en} } @article{ValeroBung2016, author = {Valero, Daniel and Bung, Daniel Bernhard}, title = {Development of the interfacial air layer in the non-aerated region of high-velocity spillway flows: Instabilities growth, entrapped air and influence on the self-aeration onset}, series = {International Journal of Multiphase Flow}, volume = {84}, journal = {International Journal of Multiphase Flow}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0301-9322}, doi = {10.1016/j.ijmultiphaseflow.2016.04.012}, pages = {66 -- 74}, year = {2016}, abstract = {Self-aeration is traditionally explained by the water turbulent boundary layer outer edge intersection with the free surface. This paper presents a discussion on the commonly accepted hypothesis behind the computation of the critical point of self-aeration in spillway flows and a new formulation is proposed based on the existence of a developing air flow over the free surface. Upstream of the inception point of self-aeration, some surface roughening has been often reported in previous studies which consequently implies some entrapped air transport and air-water flows coupling. Such air flow is proven in this study by presenting measured air velocities and computing the air boundary layer thickness for a 1V:2H smooth chute flow. Additionally, the growth rate of free surface waves has been analysed by means of Ultrasonic Sensors measurements, obtaining also the entrapped air concentration. High-speed camera imaging has been used for qualitative study of the flow perturbations.}, language = {en} } @inproceedings{BungSchlenkhoff2010, author = {Bung, Daniel Bernhard and Schlenkhoff, Andreas}, title = {Self-aerated skimming flow on embankment stepped spillways : the effect of additional micro-roughness on energy dissipation and oxygen transfer}, series = {Proceedings from first IAHR European congress : May 2010, Edinburgh}, booktitle = {Proceedings from first IAHR European congress : May 2010, Edinburgh}, publisher = {Heriot-Watt University, School of the Built Environment}, address = {Edinburgh}, organization = {International Association for Hydraulic Engineering and Research}, isbn = {9780956595102}, pages = {Artikelkennnummer HSIIId}, year = {2010}, language = {en} }