@inproceedings{MeckMuellerAltherretal.2020, author = {Meck, Marvin M. and M{\"u}ller, Tim M. and Altherr, Lena and Pelz, Peter F.}, title = {Improving an industrial cooling system using MINLP, considering capital and operating costs}, series = {Operations Research Proceedings 2019}, booktitle = {Operations Research Proceedings 2019}, publisher = {Springer}, address = {Cham}, isbn = {978-3-030-48438-5 (Print)}, doi = {10.1007/978-3-030-48439-2_61}, pages = {505 -- 512}, year = {2020}, abstract = {The chemical industry is one of the most important industrial sectors in Germany in terms of manufacturing revenue. While thermodynamic boundary conditions often restrict the scope for reducing the energy consumption of core processes, secondary processes such as cooling offer scope for energy optimisation. In this contribution, we therefore model and optimise an existing cooling system. The technical boundary conditions of the model are provided by the operators, the German chemical company BASF SE. In order to systematically evaluate different degrees of freedom in topology and operation, we formulate and solve a Mixed-Integer Nonlinear Program (MINLP), and compare our optimisation results with the existing system.}, language = {en} } @inproceedings{MuellerAltherrLeiseetal.2020, author = {M{\"u}ller, Tim M. and Altherr, Lena and Leise, Philipp and Pelz, Peter F.}, title = {Optimization of pumping systems for buildings: Experimental validation of different degrees of model detail on a modular test rig}, series = {Operations Research Proceedings 2019}, booktitle = {Operations Research Proceedings 2019}, publisher = {Springer}, address = {Cham}, isbn = {978-3-030-48438-5}, doi = {10.1007/978-3-030-48439-2_58}, pages = {481 -- 488}, year = {2020}, abstract = {Successful optimization requires an appropriate model of the system under consideration. When selecting a suitable level of detail, one has to consider solution quality as well as the computational and implementation effort. In this paper, we present a MINLP for a pumping system for the drinking water supply of high-rise buildings. We investigate the influence of the granularity of the underlying physical models on the solution quality. Therefore, we model the system with a varying level of detail regarding the friction losses, and conduct an experimental validation of our model on a modular test rig. Furthermore, we investigate the computational effort and show that it can be reduced by the integration of domain-specific knowledge.}, language = {en} } @inproceedings{EssingholtMeyerKuhnetal.2018, author = {Essingholt, Felix and Meyer, Frederic and Kuhn, Peter and Schmidt, Philip and Benkner, Thorsten and Grabmaier, Anton}, title = {Non-invasive heart beat measurement using microwave resonators}, series = {Proceedings, Vol. 2, Eurosensors 2018 Conference, Graz, Austria, 9-12 September 2018}, booktitle = {Proceedings, Vol. 2, Eurosensors 2018 Conference, Graz, Austria, 9-12 September 2018}, publisher = {MDPI}, address = {Basel}, issn = {2504-3900}, doi = {10.3390/proceedings2131002}, pages = {1002}, year = {2018}, language = {en} } @inproceedings{HoegenDonckerRuetters2020, author = {Hoegen, Anne von and Doncker, Rik W. De and R{\"u}tters, Ren{\´e}}, title = {Teaching Digital Control of Operational Amplifier Processes with a LabVIEW Interface and Embedded Hardware}, series = {2020 23rd International Conference on Electrical Machines and Systems (ICEMS)}, booktitle = {2020 23rd International Conference on Electrical Machines and Systems (ICEMS)}, publisher = {IEEE}, address = {New York, NY}, doi = {10.23919/ICEMS50442.2020.9290928}, pages = {1117 -- 1122}, year = {2020}, abstract = {Control engineering theory is hard to grasp for undergraduates during the first semesters, as it deals with the dynamical behavior of systems also in combination with control strategies on an abstract level. Therefore, operational amplifier (OpAmp) processes are reasonable and very effective systems to connect mathematical description with actual system's behavior. In this paper, we present an experiment for a laboratory session in which an embedded system, driven by a LabVIEW human machine interface (HMI) via USB, controls the analog circuits.With this setup we want to show the possibility of firstly, analyzing a first order process and secondly, designing a P-and PI-controller. Thereby, the theory of control engineering is always applied to the empirical results in order to break down the abstract level for the students.}, language = {en} } @inproceedings{SchubaHoefkenLinzbach2022, author = {Schuba, Marko and H{\"o}fken, Hans-Wilhelm and Linzbach, Sophie}, title = {An ICS Honeynet for Detecting and Analyzing Cyberattacks in Industrial Plants}, series = {2021 International Conference on Electrical, Computer and Energy Technologies (ICECET)}, booktitle = {2021 International Conference on Electrical, Computer and Energy Technologies (ICECET)}, publisher = {IEEE}, isbn = {978-1-6654-4231-2}, doi = {10.1109/ICECET52533.2021.9698746}, pages = {6 Seiten}, year = {2022}, abstract = {Cybersecurity of Industrial Control Systems (ICS) is an important issue, as ICS incidents may have a direct impact on safety of people or the environment. At the same time the awareness and knowledge about cybersecurity, particularly in the context of ICS, is alarmingly low. Industrial honeypots offer a cheap and easy to implement way to raise cybersecurity awareness and to educate ICS staff about typical attack patterns. When integrated in a productive network, industrial honeypots may not only reveal attackers early but may also distract them from the actual important systems of the network. Implementing multiple honeypots as a honeynet, the systems can be used to emulate or simulate a whole Industrial Control System. This paper describes a network of honeypots emulating HTTP, SNMP, S7communication and the Modbus protocol using Conpot, IMUNES and SNAP7. The nodes mimic SIMATIC S7 programmable logic controllers (PLCs) which are widely used across the globe. The deployed honeypots' features will be compared with the features of real SIMATIC S7 PLCs. Furthermore, the honeynet has been made publicly available for ten days and occurring cyberattacks have been analyzed}, language = {en} } @inproceedings{ChristianMontagSchubaetal.2018, author = {Christian, Esser and Montag, Tim and Schuba, Marko and Allhof, Manuel}, title = {Future critical infrastructure and security - cyberattacks on charging stations}, series = {31st International Electric Vehicle Symposium \& Exhibition and International Electric Vehicle Technology Conference (EVS31 \& EVTeC 2018)}, booktitle = {31st International Electric Vehicle Symposium \& Exhibition and International Electric Vehicle Technology Conference (EVS31 \& EVTeC 2018)}, publisher = {Society of Automotive Engineers of Japan (JSAE)}, address = {Tokyo}, isbn = {978-1-5108-9157-9}, pages = {665 -- 671}, year = {2018}, language = {en} } @inproceedings{AlhaskirTschescheLinkeetal.2023, author = {Alhaskir, Mohamed and Tschesche, Matteo and Linke, Florian and Schriewer, Elisabeth and Weber, Yvonne and Wolking, Stefan and R{\"o}hrig, Rainer and Koch, Henner and Kutafina, Ekaterina}, title = {ECG matching: an approach to synchronize ECG datasets for data quality comparisons}, series = {Proceedings of the 68th Annual Meeting of the German Association of Medical Informatics, Biometry, and Epidemiology e.V. (gmds) 2023}, volume = {307}, booktitle = {Proceedings of the 68th Annual Meeting of the German Association of Medical Informatics, Biometry, and Epidemiology e.V. (gmds) 2023}, editor = {R{\"o}hrig, Rainer and Grabe, Niels and Haag, Martin and H{\"u}bner, Ursula and Sax, Ulrich and Schmidt, Carsten Oliver and Sedlmayr, Martin and Zapf, Antonia}, publisher = {IOS Press}, isbn = {978-1-64368-428-4 (Print)}, doi = {10.3233/SHTI230718}, pages = {225 -- 232}, year = {2023}, abstract = {Clinical assessment of newly developed sensors is important for ensuring their validity. Comparing recordings of emerging electrocardiography (ECG) systems to a reference ECG system requires accurate synchronization of data from both devices. Current methods can be inefficient and prone to errors. To address this issue, three algorithms are presented to synchronize two ECG time series from different recording systems: Binned R-peak Correlation, R-R Interval Correlation, and Average R-peak Distance. These algorithms reduce ECG data to their cyclic features, mitigating inefficiencies and minimizing discrepancies between different recording systems. We evaluate the performance of these algorithms using high-quality data and then assess their robustness after manipulating the R-peaks. Our results show that R-R Interval Correlation was the most efficient, whereas the Average R-peak Distance and Binned R-peak Correlation were more robust against noisy data.}, language = {en} } @inproceedings{TischbeinKeanVertgewalletal.2023, author = {Tischbein, Franziska and Kean, Kilian and Vertgewall, Chris Martin and Ulbig, Andreas and Altherr, Lena}, title = {Determination of the topology of low-voltage distribution grids using cluster methods}, series = {27th International Conference on Electricity Distribution (CIRED 2023)}, booktitle = {27th International Conference on Electricity Distribution (CIRED 2023)}, publisher = {IEEE}, isbn = {978-1-83953-855-1}, doi = {10.1049/icp.2023.0478}, pages = {1 -- 5}, year = {2023}, abstract = {Due to the decarbonization of the energy sector, the electric distribution grids are undergoing a major transformation, which is expected to increase the load on the operating resources due to new electrical loads and distributed energy resources. Therefore, grid operators need to gradually move to active grid management in order to ensure safe and reliable grid operation. However, this requires knowledge of key grid variables, such as node voltages, which is why the mass integration of measurement technology (smart meters) is necessary. Another problem is the fact that a large part of the topology of the distribution grids is not sufficiently digitized and models are partly faulty, which means that active grid operation management today has to be carried out largely blindly. It is therefore part of current research to develop methods for determining unknown grid topologies based on measurement data. In this paper, different clustering algorithms are presented and their performance of topology detection of low voltage grids is compared. Furthermore, the influence of measurement uncertainties is investigated in the form of a sensitivity analysis.}, language = {en} } @inproceedings{SchulteTiggesMatheisRekeetal.2023, author = {Schulte-Tigges, Joschua and Matheis, Dominik and Reke, Michael and Walter, Thomas and Kaszner, Daniel}, title = {Demonstrating a V2X enabled system for transition of control and minimum risk manoeuvre when leaving the operational design domain}, series = {HCII 2023: HCI in Mobility, Transport, and Automotive Systems}, booktitle = {HCII 2023: HCI in Mobility, Transport, and Automotive Systems}, editor = {Kr{\"o}mker, Heidi}, publisher = {Springer}, address = {Cham}, isbn = {978-3-031-35677-3 (Print)}, doi = {10.1007/978-3-031-35678-0_12}, pages = {200 -- 210}, year = {2023}, abstract = {Modern implementations of driver assistance systems are evolving from a pure driver assistance to a independently acting automation system. Still these systems are not covering the full vehicle usage range, also called operational design domain, which require the human driver as fall-back mechanism. Transition of control and potential minimum risk manoeuvres are currently research topics and will bridge the gap until full autonomous vehicles are available. The authors showed in a demonstration that the transition of control mechanisms can be further improved by usage of communication technology. Receiving the incident type and position information by usage of standardised vehicle to everything (V2X) messages can improve the driver safety and comfort level. The connected and automated vehicle's software framework can take this information to plan areas where the driver should take back control by initiating a transition of control which can be followed by a minimum risk manoeuvre in case of an unresponsive driver. This transition of control has been implemented in a test vehicle and was presented to the public during the IEEE IV2022 (IEEE Intelligent Vehicle Symposium) in Aachen, Germany.}, language = {en} } @inproceedings{GaldiHartungDugelay2017, author = {Galdi, Chiara and Hartung, Frank and Dugelay, Jean-Luc}, title = {Videos versus still images: Asymmetric sensor pattern noise comparison on mobile phones}, series = {Electronic Imaging}, booktitle = {Electronic Imaging}, publisher = {Society for Imaging Science and Technology}, address = {Springfield, Virginia}, issn = {2470-1173}, doi = {10.2352/ISSN.2470-1173.2017.7.MWSF-331}, pages = {100 -- 103}, year = {2017}, abstract = {Nowadays, the most employed devices for recoding videos or capturing images are undoubtedly the smartphones. Our work investigates the application of source camera identification on mobile phones. We present a dataset entirely collected by mobile phones. The dataset contains both still images and videos collected by 67 different smartphones. Part of the images consists in photos of uniform backgrounds, especially collected for the computation of the RSPN. Identifying the source camera given a video is particularly challenging due to the strong video compression. The experiments reported in this paper, show the large variation in performance when testing an highly accurate technique on still images and videos.}, language = {en} }