@article{KaminskyWeberSimonsetal.2005, author = {Kaminsky, Randolph and Weber, Hans-Joachim and Simons, Antoine and Kallweit, Stephan and Kramm, K. and Verdonck, Pascale}, title = {Comparison of the flow downstream two prototypes of a new monoleaflet artificial aortic heart valve by means of PIV visualization}, series = {Computer methods in biomechanics and biomedical engineering. 8 (2005), H. 4, Suppl. 1}, journal = {Computer methods in biomechanics and biomedical engineering. 8 (2005), H. 4, Suppl. 1}, isbn = {1476-8259}, pages = {159 -- 160}, year = {2005}, language = {en} } @article{KhodaverdiChatziioannouWeberetal.2005, author = {Khodaverdi, M. and Chatziioannou, A. F. and Weber, S. and Ziemons, Karl and Halling, H. and Pietrzyk, U.}, title = {Investigation of different MicroCT scanner configurations by GEANT4 simulations}, series = {IEEE Transactions on Nuclear Science}, volume = {52}, journal = {IEEE Transactions on Nuclear Science}, number = {1}, isbn = {0018-9499}, pages = {188 -- 192}, year = {2005}, abstract = {This study has been performed to design the combination of the new ClearPET (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal positron emission tomography (PET) system, with a micro-computed tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We will demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material.}, language = {en} } @article{KotliarKoshitzSvetlowaetal.2005, author = {Kotliar, Konstantin and Koshitz, I. N. and Svetlowa, O. V. and Makarov, F. N.}, title = {Biomechanical analysis of traditional and contemporary conceptions on pathogenesis of the primary open angle glaucoma / Koshitz, I. N. ; Svetlova, O. V. ; Kotliar, K. E. ; Makarov, F. N. ; Smolnikov, B. A.}, series = {Glaukoma (2005)}, journal = {Glaukoma (2005)}, publisher = {-}, pages = {41 -- 63}, year = {2005}, language = {en} } @inproceedings{KraftSchneider2005, author = {Kraft, Bodo and Schneider, Gerd}, title = {Semantic Roomobjects for Conceptual Design Support : A Knowledge-based Approach}, isbn = {978-1-4020-3460-2}, year = {2005}, abstract = {In: Computer Aided Architectural Design Futures 2005 2005, Part 4, 207-216, DOI: http://dx.doi.org/10.1007/1-4020-3698-1_19 The conceptual design at the beginning of the building construction process is essential for the success of a building project. Even if some CAD tools allow elaborating conceptual sketches, they rather focus on the shape of the building elements and not on their functionality. We introduce semantic roomobjects and roomlinks, by way of example to the CAD tool ArchiCAD. These extensions provide a basis for specifying the organisation and functionality of a building and free architects being forced to directly produce detailed constructive sketches. Furthermore, we introduce consistency analyses of the conceptual sketch, based on an ontology containing conceptual relevant knowledge, specific to one class of buildings.}, subject = {CAD}, language = {en} } @inproceedings{KraftWilhelms2005, author = {Kraft, Bodo and Wilhelms, Nils}, title = {Visual Knowledge Specification for Conceptual Design}, year = {2005}, abstract = {Proc. of the 2005 ASCE Intl. Conf. on Computing in Civil Engineering (ICCC 2005) eds. L. Soibelman und F. Pena-Mora, Seite 1-14, ASCE (CD-ROM), Cancun, Mexico, 2005 Current CAD tools are not able to support the fundamental conceptual design phase, and none of them provides consistency analyses of sketches produced by architects. To give architects a greater support at the conceptual design phase, we develop a CAD tool for conceptual design and a knowledge specification tool allowing the definition of conceptually relevant knowledge. The knowledge is specific to one class of buildings and can be reused. Based on a dynamic knowledge model, different types of design rules formalize the knowledge in a graph-based realization. An expressive visual language provides a user-friendly, human readable representation. Finally, consistency analyses enable conceptual designs to be checked against this defined knowledge. In this paper we concentrate on the knowledge specification part of our project.}, subject = {CAD}, language = {en} } @article{MaggakisKelemenDigelArtmann2005, author = {Maggakis-Kelemen, Christina and Digel, Ilya and Artmann, Gerhard}, title = {Polystyrene sulfonate/Polyallylamine hydrochloride microcapsules as potential artificial red blood cells - improvement of capsule flexibility}, series = {Biomedizinische Technik. 50 (2005), H. Erg.-Bd. 1}, journal = {Biomedizinische Technik. 50 (2005), H. Erg.-Bd. 1}, pages = {324 -- 326}, year = {2005}, language = {en} } @article{MuellerVeggianDeNardoBalbinotetal.2005, author = {M{\"u}ller-Veggian, Mattea and De Nardo, L. and Balbinot, G. and Colautti, P.}, title = {Leak Microstructures Operation at low pressure of propane: application at the Trigger\&Anti-Trigger system of the STARTRACK Experiment}, series = {Annual report / Istituto Nazionale di Fisica Nucleare, LNL, Laboratori Nazionali di Legnaro. 2004 (2005)}, journal = {Annual report / Istituto Nazionale di Fisica Nucleare, LNL, Laboratori Nazionali di Legnaro. 2004 (2005)}, isbn = {88-7337-008-X}, pages = {242 -- 243}, year = {2005}, language = {en} } @article{MuellerVeggianGarbeNouretal.2005, author = {M{\"u}ller-Veggian, Mattea and Garbe, S. and Nour, Y. and Wolf, K.}, title = {Scattered dose determination using the semiconductor diodes for a mask based whole brain radiotherapy (WBRT) with high-energy photons}, series = {Biomedizinische Technik. 50 (2005), H. 2}, journal = {Biomedizinische Technik. 50 (2005), H. 2}, isbn = {0932-4666}, pages = {1069 -- 1070}, year = {2005}, language = {en} } @article{MuellerVeggianGarbeNouretal.2005, author = {M{\"u}ller-Veggian, Mattea and Garbe, S. and Nour, Y. and Wolf, K.}, title = {468 Scatter dose determination at the eye lens during a mask based whole brain radiotherapy (WBRT)}, series = {Radiotherapy and Oncology}, volume = {76}, journal = {Radiotherapy and Oncology}, number = {Suppl. 2}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0167-8140}, doi = {10.1016/S0167-8140(05)81444-6}, pages = {S202}, year = {2005}, language = {en} } @article{MuellerVeggianTurekColautti2005, author = {M{\"u}ller-Veggian, Mattea and Turek, M. and Colautti, P.}, title = {The new Twin mini TEPC: an advanced tool for Boron Neutron Capture Therapy}, series = {Annual report / Istituto Nazionale di Fisica Nucleare, LNL, Laboratori Nazionali di Legnaro. 2004 (2005)}, journal = {Annual report / Istituto Nazionale di Fisica Nucleare, LNL, Laboratori Nazionali di Legnaro. 2004 (2005)}, isbn = {88-7337-008-X}, pages = {244 -- 245}, year = {2005}, language = {en} }