@article{SpelthahnSchubertSchoening2012, author = {Spelthahn, Heiko and Schubert, J{\"u}rgen and Sch{\"o}ning, Michael Josef}, title = {D{\"u}nnschichtsensoren f{\"u}r die Schwermetallanalytik}, series = {GIT : Labor-Fachzeitschrift}, volume = {56}, journal = {GIT : Labor-Fachzeitschrift}, number = {4}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0016-3538}, pages = {285 -- 287}, year = {2012}, abstract = {Die Detektion von Schadstoffen repr{\"a}sentiert in der Umweltanalytik eine wichtige Aufgabenstellung. Gerade die Abwasser- bzw. Brauchwasseranalytik sowie die Prozesskontrolle haben einen hohen Stellenwert. Siliziumbasierte D{\"u}nnschichtsensoren bieten eine kosteng{\"u}nstige M{\"o}glichkeit, „online"-Messungen bzw. Vor-Ort-Messungen zeitnah durchzuf{\"u}hren. In dieser Arbeit wird ein potentiometrisches Sensorarray auf der Basis von Chalkogenidgl{\"a}sern zur Detektion von Schwermetallen in w{\"a}ssrigen Medien vorgestellt.}, language = {en} } @inproceedings{GerhardsSanderBelloum2012, author = {Gerhards, Michael and Sander, Volker and Belloum, Adam}, title = {About the flexible Migration of Workflow Tasks to Clouds : Combining on- and off-premise Executions of Applications}, series = {CLOUD COMPUTING 2012 : The Third International Conference on Cloud Computing, GRIDs, and Virtualization ; July 22-27, 2012 - Nice, France}, booktitle = {CLOUD COMPUTING 2012 : The Third International Conference on Cloud Computing, GRIDs, and Virtualization ; July 22-27, 2012 - Nice, France}, editor = {Zimmermann, Wolf and Lee, Yong Woo and Demchenko, Yuri}, publisher = {IARIA Journals}, isbn = {978-1-61208-216-5}, pages = {82 -- 87}, year = {2012}, abstract = {An increasing number of applications target their executions on specific hardware like general purpose Graphics Processing Units. Some Cloud Computing providers offer this specific hardware so that organizations can rent such resources. However, outsourcing the whole application to the Cloud causes avoidable costs if only some parts of the application benefit from the specific expensive hardware. A partial execution of applications in the Cloud is a tradeoff between costs and efficiency. This paper addresses the demand for a consistent framework that allows for a mixture of on- and off-premise calculations by migrating only specific parts to a Cloud. It uses the concept of workflows to present how individual workflow tasks can be migrated to the Cloud whereas the remaining tasks are executed on-premise.}, language = {en} } @article{KotliarLanzlHanssenetal.2012, author = {Kotliar, Konstantin and Lanzl, Ines M. and Hanssen, Henner and Eberhardt, Karla and Vilser, Walthard and Halle, Martin and Heemann, Uwe and Schmidt-Trucks{\"a}ss, Arno and Baumann, Marcus}, title = {Does increased blood pressure rather than aging influence retinal pulse wave velocity?}, series = {Investigative Ophthalmology \& Visual Science, IOVS}, volume = {53}, journal = {Investigative Ophthalmology \& Visual Science, IOVS}, number = {4}, publisher = {ARVO}, address = {Rockville, Md.}, issn = {0146-0404}, doi = {10.1167/iovs.11-8815}, pages = {2119 -- 2126}, year = {2012}, abstract = {Purpose: It was demonstrated previously that retinal pulse wave velocity (rPWV) as a measure of retinal arterial stiffness is increased in aged anamnestically healthy volunteers compared with young healthy subjects. Using novel methodology of rPWV assessment this finding was confirmed and investigated whether it might relate to the increased blood pressure usually accompanying the aging process, rather than to the aging itself. Methods: A total of 12 young 25.5-year-old (24.0-28.8) [median(1st quartile-3rd quartile)] and 12 senior 68.5-year-old (63.8-71.8) anamnestically healthy volunteers; and 12 senior 63.0-year-old (60.8-65.0) validated healthy volunteers and 12 young 33.0-year-old (29.5-35.0) hypertensive patients were examined. Time-dependent alterations of vessel diameter were assessed by the Dynamic Vessel Analyzer in a retinal artery of each subject. The data were filtered and processed using mathematical signal analysis and rPWVs were calculated. Results: rPWV amounted to 1200 (990-1470) RU (relative units)/s in the hypertensive group and to 1040 (700-2230) RU/s in anamnestically healthy seniors. These differed significantly from rPWVs in young healthy group (410 [280-500] RU/s) and in validated healthy seniors (400 [320-510] RU/s). rPWV associated with age and mean arterial pressure (MAP) in the pooled cohort excluded validated healthy seniors. In a regression model these associations remain when alternately adjusted for MAP and age. When including validated healthy seniors in the pooled cohort only association with MAP remains. Conclusions: Both aging (with not excluded cardiovascular risk factors) and mild hypertension are associated with elevated rPWV. rPWV increases to a similar extent both in young mildly hypertensive subjects and in aged anamnestically healthy persons. Healthy aging is not associated with increased rPWV.}, language = {en} } @article{BohrnStuetzFuchsetal.2012, author = {Bohrn, U. and St{\"u}tz, E. and Fuchs, K. and Fleischer, M. and Sch{\"o}ning, Michael Josef and Wagner, P.}, title = {Monitoring of irritant gas using a whole-cell-based sensor system}, series = {Sensors and Actuators B: Chemical}, volume = {175}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2012.05.088}, pages = {208 -- 217}, year = {2012}, abstract = {Cell-based sensors for the detection of gases have long been underrepresented, due to the cellular requirement of being cultured in a liquid environment. In this work we established a cell-based gas biosensor for the detection of toxic substances in air, by adapting a commercial sensor chip (Bionas®), previously used for the measurement of pollutants in liquids. Cells of the respiratory tract (A549, RPMI 2650, V79), which survive at a gas phase in a natural context, are used as biological receptors. The physiological cell parameters acidification, respiration and morphology are continuously monitored in parallel. Ammonia was used as a highly water-soluble model gas to test the feasibility of the sensor system. Infrared measurements confirmed the sufficiency of the medium draining method. This sensor system provides a basis for many sensor applications such as environmental monitoring, building technology and public security.}, language = {en} } @article{KirchnerReisertPuetzetal.2012, author = {Kirchner, Patrick and Reisert, Steffen and P{\"u}tz, Patrick and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Characterisation of polymeric materials as passivation layer for calorimetric H2O2 gas sensors}, series = {Physica Status Solidi (a)}, volume = {209}, journal = {Physica Status Solidi (a)}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201100773}, pages = {859 -- 863}, year = {2012}, abstract = {Calorimetric gas sensors for monitoring the H₂O₂ concentration at elevated temperatures in industrial sterilisation processes have been presented in previous works. These sensors are built up in form of a differential set-up of a catalytically active and passive temperature-sensitive structure. Although, various types of catalytically active dispersions have been studied, the passivation layer has to be established and therefore, chemically as well as physically characterised. In the present work, fluorinated ethylene propylene (FEP), perfluoralkoxy (PFA) and epoxy-based SU-8 photoresist as temperature-stable polymeric materials have been investigated for sensor passivation in terms of their chemical inertness against H₂O₂, their hygroscopic properties as well as their morphology. The polymeric materials were deposited via spin-coating on the temperature-sensitive structure, wherein spin-coated FEP and PFA show slight agglomerates. However, they possess a low absorption of humidity due to their hydrophobic surface, whereas the SU-8 layer has a closed surface but shows a slightly higher absorption of water. All of them were inert against gaseous H₂O₂ during the characterisation in H₂O₂ atmosphere that demonstrates their suitability as passivation layer for calorimetric H₂O₂ gas sensors.}, language = {en} } @inproceedings{BohrnMuchaWerneretal.2012, author = {Bohrn, Ulrich and Mucha, Andreas and Werner, Frederik and St{\"u}tz, Evamaria and B{\"a}cker, Matthias and Krumbe, Christoph and Schienle, Meinrad and Fleischer, Maximilian and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Detection of toxic chromium species in water using cellbased sensor systems}, isbn = {978-3-9813484-2-2}, doi = {10.5162/IMCS2012/P2.1.14}, pages = {1364 -- 1367}, year = {2012}, language = {en} } @inproceedings{BohrnStuetzFleischeretal.2012, author = {Bohrn, Ulrich and St{\"u}tz, Evamaria and Fleischer, Maximilian and Sch{\"o}ning, Michael Josef and Wagner, Patrick}, title = {Living cell-based gas sensor system for the detection of acetone in air}, isbn = {978-3-9813484-2-2}, doi = {10.5162/IMCS2012/3.2.3}, pages = {269 -- 272}, year = {2012}, language = {en} } @inproceedings{TakenagaWernerSawadaetal.2012, author = {Takenaga, Shoko and Werner, Frederik and Sawada, Kazuaki and Sch{\"o}ning, Michael Josef}, title = {Comparison of label-free ACh image sensors based on CCD and LAPS}, isbn = {978-3-9813484-2-2}, doi = {10.5162/IMCS2012/4.2.6}, pages = {356 -- 359}, year = {2012}, language = {en} } @book{Bialonski2012, author = {Bialonski, Stephan}, title = {Inferring complex networks from time series of dynamical systems: Pitfalls, misinterpretations, and possible solutions}, publisher = {Universit{\"a}ts- und Landesbibliothek Bonn}, address = {Bonn}, pages = {Online-Ausgabe (III, 135 S. : Ill., graph. Darst.)}, year = {2012}, language = {en} } @inproceedings{DuongNguyenStaat2012, author = {Duong, Minh Tuan and Nguyen, Nhu Hunyh and Staat, Manfred}, title = {Finite Element Implementation of a 3D Fung-type Model}, series = {ESMC-2012 - 8th European Solid Mechanics Conference, Graz, Austria, July 9-13, 2012}, booktitle = {ESMC-2012 - 8th European Solid Mechanics Conference, Graz, Austria, July 9-13, 2012}, publisher = {Verlag d. Technischen Universit{\"a}t Graz}, address = {Graz}, isbn = {978-3-85125-223-1}, year = {2012}, language = {en} }