@article{HengsbachEngelCwienczeketal.2023, author = {Hengsbach, Jan-Niklas and Engel, Mareike and Cwienczek, Marcel and Stiefelmaier, Judith and Tippk{\"o}tter, Nils and Ulber, Roland}, title = {Scalable unseparated bioelectrochemical reactors by using a carbon fiber brush as stirrer and working electrode}, series = {ChemElectroChem}, volume = {10}, journal = {ChemElectroChem}, number = {21}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {2196-0216}, doi = {10.1002/celc.202300440}, pages = {9 Seiten}, year = {2023}, abstract = {The concept of energy conversion into platform chemicals using bioelectrochemical systems (BES) has gained increasing attention in recent years, as the technology simultaneously provides an opportunity for sustainable chemical production and tackles the challenge of Power-to-X technologies. There are many approaches to realize the industrial scale of BES. One concept is to equip standard bioreactors with static electrodes. However, large installations resulted in a negative influence on various reactor parameters. In this study, we present a new single-chamber BES based on a stirred tank reactor in which the stirrer was replaced by a carbon fiber brush, performing the functions of the working electrode and the stirrer. The reactor is characterized in abiotic studies and electro-fermentations with Clostridium acetobutylicum. Compared to standard reactors an increase in butanol production of 20.14±3.66 \% shows that the new BES can be efficiently used for bioelectrochemical processes.}, language = {en} } @article{BragardvanHoekDeDoncker2012, author = {Bragard, Michael and van Hoek, H. and De Doncker, R. W.}, title = {A major design step in IETO concept realization that allows overcurrent protection and pushes limits of switching performance}, series = {IEEE transactions on power electronics}, volume = {27}, journal = {IEEE transactions on power electronics}, number = {9}, publisher = {IEEE}, address = {New York}, issn = {0885-8993}, doi = {10.1109/TPEL.2012.2189136}, pages = {4163 -- 4171}, year = {2012}, abstract = {This paper presents the latest prototype of the integrated emitter turn-off thyristor concept, which potentially ranks among thyristor high-power devices like the gate turn-off thyristor and the integrated gate-commutated thyristor (IGCT). Due to modifications of the external driver stage and mechanical press-pack design optimization, this prototype allows for full device characterization. The turn-off capability was increased to 1600 A with an active silicon area of 823mm2 . This leads to a transient peak power of 672.1kW/cm² . Within this paper, measurements and concept assessment are presented and a comparison to state-of-the-art IGCT devices is provided.}, language = {en} } @article{HerrmannKellyPrice2002, author = {Herrmann, Ulf and Kelly, Bruce and Price, Henry}, title = {Two Tank Molten Salt Storage for Parabolic Trough Solar Power Plants}, series = {Energy : the international journal}, volume = {29}, journal = {Energy : the international journal}, number = {5-6 (Special Issue SolarPaces)}, issn = {0360-5442}, doi = {10.1016/S0360-5442(03)00193-2}, pages = {883 -- 893}, year = {2002}, language = {en} } @article{Helmig2010, author = {Helmig, Ilka}, title = {Nitty - fontnames illustrated}, series = {Slanted}, journal = {Slanted}, number = {11}, publisher = {Slanted Publishers}, address = {Karlsruhe}, issn = {1867-6510}, pages = {68 -- 69}, year = {2010}, language = {en} } @article{EggertKling2023, author = {Eggert, Mathias and Kling, Rene}, title = {How to distribute charging requests of electronic vehicles? A reservation-based approach}, series = {International Journal of Intelligent Transportation Systems Research}, volume = {21}, journal = {International Journal of Intelligent Transportation Systems Research}, number = {2023}, publisher = {Springer}, address = {Berlin, Heidelberg, New York}, issn = {1868-8659}, doi = {10.1007/s13177-023-00367-z}, pages = {437 -- 460}, year = {2023}, abstract = {The number of electronic vehicles increase steadily while the space for extending the charging infrastructure is limited. In particular in urban areas, where parking spaces in attractive areas are famous, opportunities to setup new charging stations is very limited. This leads to an overload of some very attractive charging stations and an underutilization of less attractive ones. Against this background, the paper at hand presents the design of an e-vehicle reservation system that aims at distributing the utilization of the charging infrastructure, particularly in urban areas. By applying a design science approach, the requirements for a reservation-based utilization approach are elicited and a model for a suitable distribution approach and its instantiation are developed. The artefact is evaluated by simulating the distribution effects based on data of real charging station utilizations.}, language = {en} } @article{HarrisKleefeld2018, author = {Harris, Isaac and Kleefeld, Andreas}, title = {The inverse scattering problem for a conductive boundary condition and transmission eigenvalues}, series = {Applicable Analysis}, volume = {99}, journal = {Applicable Analysis}, number = {3}, publisher = {Taylor \& Francis}, address = {London}, issn = {1563-504X}, doi = {10.1080/00036811.2018.1504028}, pages = {508 -- 529}, year = {2018}, abstract = {In this paper, we consider the inverse scattering problem associated with an inhomogeneous media with a conductive boundary. In particular, we are interested in two problems that arise from this inverse problem: the inverse conductivity problem and the corresponding interior transmission eigenvalue problem. The inverse conductivity problem is to recover the conductive boundary parameter from the measured scattering data. We prove that the measured scatted data uniquely determine the conductivity parameter as well as describe a direct algorithm to recover the conductivity. The interior transmission eigenvalue problem is an eigenvalue problem associated with the inverse scattering of such materials. We investigate the convergence of the eigenvalues as the conductivity parameter tends to zero as well as prove existence and discreteness for the case of an absorbing media. Lastly, several numerical and analytical results support the theory and we show that the inside-outside duality method can be used to reconstruct the interior conductive eigenvalues.}, language = {en} } @article{MartinFrauenrathOezerdemetal.2011, author = {Martin, Conrad and Frauenrath, Tobias and {\"O}zerdem, Celal and Renz, Wolfgang and Niendorf, Thoralf}, title = {Development and evaluation of a small and mobile Magneto Alert Sensor (MALSE) to support safety requirements for magnetic resonance imaging}, series = {European Radiology}, volume = {21}, journal = {European Radiology}, publisher = {Springer}, address = {Berlin, Heidelberg}, issn = {1432-1084}, doi = {10.1007/s00330-011-2153-z}, pages = {2187 -- 2192}, year = {2011}, abstract = {Objective The purpose of this study is to (i) design a small and mobile Magnetic field ALert SEnsor (MALSE), (ii) to carefully evaluate its sensors to their consistency of activation/deactivation and sensitivity to magnetic fields, and (iii) to demonstrate the applicability of MALSE in 1.5 T, 3.0 T and 7.0 T MR fringe field environments. Methods MALSE comprises a set of reed sensors, which activate in response to their exposure to a magnetic field. The activation/deactivation of reed sensors was examined by moving them in/out of the fringe field generated by 7TMR. Results The consistency with which individual reed sensors would activate at the same field strength was found to be 100\% for the setup used. All of the reed switches investigated required a substantial drop in ambient magnetic field strength before they deactivated. Conclusions MALSE is a simple concept for alerting MRI staff to a ferromagnetic object being brought into fringe magnetic fields which exceeds MALSEs activation magnetic field. MALSE can easily be attached to ferromagnetic objects within the vicinity of a scanner, thus creating a barrier for hazardous situations induced by ferromagnetic parts which should not enter the vicinity of an MR-system to occur.}, language = {en} } @article{Gaigall2021, author = {Gaigall, Daniel}, title = {Test for Changes in the Modeled Solvency Capital Requirement of an Internal Risk Model}, series = {ASTIN Bulletin}, volume = {51}, journal = {ASTIN Bulletin}, number = {3}, publisher = {Cambridge Univ. Press}, address = {Cambridge}, issn = {1783-1350}, doi = {10.1017/asb.2021.20}, pages = {813 -- 837}, year = {2021}, abstract = {In the context of the Solvency II directive, the operation of an internal risk model is a possible way for risk assessment and for the determination of the solvency capital requirement of an insurance company in the European Union. A Monte Carlo procedure is customary to generate a model output. To be compliant with the directive, validation of the internal risk model is conducted on the basis of the model output. For this purpose, we suggest a new test for checking whether there is a significant change in the modeled solvency capital requirement. Asymptotic properties of the test statistic are investigated and a bootstrap approximation is justified. A simulation study investigates the performance of the test in the finite sample case and confirms the theoretical results. The internal risk model and the application of the test is illustrated in a simplified example. The method has more general usage for inference of a broad class of law-invariant and coherent risk measures on the basis of a paired sample.}, language = {en} } @article{DerschGeyerHerrmannetal.2004, author = {Dersch, J{\"u}rgen and Geyer, Michael and Herrmann, Ulf and Jones, Scott A. and Kelly, Bruce and Kistner, Rainer and Ortmanns, Winfried and Pitz-Paal, Robert and Price, Henry}, title = {Trough integration into power plants—a study on the performance and economy of integrated solar combined cycle systems}, series = {Energy : the international journal}, volume = {29}, journal = {Energy : the international journal}, number = {5-6 (Special Issue SolarPaces)}, issn = {0360-5442}, doi = {10.1016/S0360-5442(03)00199-3}, pages = {947 -- 959}, year = {2004}, language = {en} } @article{PuppeGiulianoFrantzetal.2018, author = {Puppe, Michael and Giuliano, Stefano and Frantz, Cathy and Uhlig, Ralf and Schumacher, Ralph and Ibraheem, Wagdi and Schmalz, Stefan and Waldmann, Barbara and Guder, Christoph and Peter, Dennis and Schwager, Christian and Teixeira Boura, Cristiano Jos{\´e} and Alexopoulos, Spiros and Spiegel, Michael and Wortmann, J{\"u}rgen and Hinrichs, Matthias and Engelhard, Manfred and Aust, Michael}, title = {Techno-economic optimization of molten salt solar tower plants}, series = {AIP Conference Proceedings art.no. 040033}, volume = {2033}, journal = {AIP Conference Proceedings art.no. 040033}, number = {Issue 1}, publisher = {AIP Publishing}, address = {Melville, NY}, doi = {10.1063/1.5067069}, year = {2018}, abstract = {In this paper the results of a techno-economic analysis of improved and optimized molten salt solar tower plants (MSSTP plants) are presented. The potential improvements that were analyzed include different receiver designs, different designs of the HTF-system and plant control, increased molten salt temperatures (up to 640°C) and multi-tower systems. Detailed technological and economic models of the solar field, solar receiver and high temperature fluid system (HTF-system) were developed and used to find potential improvements compared to a reference plant based on Solar Two technology and up-to-date cost estimations. The annual yield model calculates the annual outputs and the LCOE of all variants. An improved external tubular receiver and improved HTF-system achieves a significant decrease of LCOE compared to the reference. This is caused by lower receiver cost as well as improvements of the HTF-system and plant operation strategy, significantly reducing the plant own consumption. A novel star receiver shows potential for further cost decrease. The cavity receiver concepts result in higher LCOE due to their high investment cost, despite achieving higher efficiencies. Increased molten salt temperatures seem possible with an adapted, closed loop HTF-system and achieve comparable results to the original improved system (with 565°C) under the given boundary conditions. In this analysis all multi tower systems show lower economic viability compared to single tower systems, caused by high additional cost for piping connections and higher cost of the receivers. REFERENCES}, language = {en} }