@inproceedings{EngelThieringerTippkoetter2016, author = {Engel, Mareike and Thieringer, Julia and Tippk{\"o}tter, Nils}, title = {Linking bioprocess engineering and electrochemistry for sustainable biofuel production}, series = {Young Researchers Symposium, YRS 2016. Proceedings}, booktitle = {Young Researchers Symposium, YRS 2016. Proceedings}, publisher = {Fraunhofer Verlag}, address = {Karlsruhe}, pages = {49 -- 53}, year = {2016}, abstract = {Electromicrobial engineering is an emerging, highly interdisciplinary research area linking bioprocesses with electrochemistry. In this work, microbial electrosynthesis (MES) of biobutanol is carried out during acetone-butanol-ethanol (ABE) fermentations with Clostridium acetobutylicum. A constant electric potential of -600mV (vs. Ag/AgCl) with simultaneous addition of the soluble redox mediator neutral red is used in order to study the electron transfer between the working electrode and the bacterial cells. The results show an earlier initiation of solvent production for all fermentations with applied potential compared to the conventional ABE fermentation. The f inal butanol concentration can be more than doubled by the application of a negative potential combined with addition of neutral red. Moreover a higher biofilm formation on the working electrode compared to control cultivations has been observed. In contrast to previous studies, our results also indicate that direct electron transfer (DET) might be possible with C. acetobutylicum. The presented results make microbial butanol production economically attractive and therefore support the development of sustainable production processes in the chemical industry aspired by the "Centre for resource-efficient chemistry and raw material change" as well as the the project "NanoKat" working on nanostructured catalysts in Kaiserslautern.}, language = {en} } @misc{DuweSchlegelTippkoetteretal.2014, author = {Duwe, A. and Schlegel, C. and Tippk{\"o}tter, Nils and Ulber, Roland}, title = {Sequentielle Extraktion von Cellulose zur effizienten Nutzung der Stoffstr{\"o}me in der Holzbioraffinerie}, series = {Chemie Ingenieur Technik}, volume = {86}, journal = {Chemie Ingenieur Technik}, number = {9}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.201450308}, pages = {1400}, year = {2014}, abstract = {In der Reihe der nachwachsenden Rohstoffe besitzt Holz als erneuerbare und umweltfreundliche Ressource ein großes Potenzial. {\"U}ber 11 Mio. ha Holz, das laut der Fachagentur f{\"u}r nachwachsende Rohstoffe (FNR) auch f{\"u}r industrielle Zwecke genutzt werden kann, wuchsen im Jahr 2013 allein auf bundesdeutscher Fl{\"a}che. 56,8 Mio. m³ j{\"a}hrlicher Holzeinschlag in den letzten zehn Jahren wurde zu knapp der H{\"a}lfte stofflich und der Rest energetisch verwertet. Im Rahmen dieser Arbeit konnte auf der Basis vom Holz der Buche, die nach Fichte und Kiefer die dritth{\"a}ufigste Baumart in Deutschland ist und 15\% der deutschen Waldfl{\"a}che ausmacht, die Fraktionierung der polymeren Hauptbestandteile mit niedrigem energetischen Einsatz erreicht werden. Hierbei werden in einem nachgeschalteten Extraktionsprozess die beiden Komponenten Hemicellulose und Lignin in fl{\"u}ssiger Form von der finalen festen Cellulosefraktion abgetrennt. Die Extraktion der Hemicellulose erfolgt durch eine Liquid Hot Water (LHW)-Behandlung. Untersucht wird der katalytische Zusatz anorganischer S{\"a}uren wie H₃PO₄ und H₂SO₄. Im Hinblick auf die weitere Verwertung von Lignin zu aromatischen Synthesebausteinen kommt die Organosolv-Extraktion mit einem Ethanol/Wasser-Gemisch zum Einsatz. Von Vorteil ist die weitere Verwendung beider Stoffstr{\"o}me ohne F{\"a}llungsschritt und nachteiliger Verd{\"u}nnung der Hemicellulose.}, language = {en} } @misc{MoehringWulfhorstCapitainetal.2016, author = {M{\"o}hring, S. and Wulfhorst, H. and Capitain, C. and Roth, J. and Tippk{\"o}tter, Nils}, title = {Fractioning of lignocellulosic biomass: Scale-down and automation of thermal pretreatment for parameter optimization}, series = {Chemie Ingenieur Technik}, volume = {88}, journal = {Chemie Ingenieur Technik}, number = {9}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.201650288}, pages = {1229}, year = {2016}, abstract = {In order to efficiently convert lignocellulose, it is often necessary to conduct a pretreatment. The biomass considered in this study typically comprises of agricultural and horticultural residues, as well as beechwood. A very environmentally friendly method, namely, fungal pretreatment using white-rot fungi, leads to an enhanced enzymatic hydrolysis. In contrast to other processes presented, the energy input is extremely low. However, the fungal growth on the lignocellulosic substrates takes several weeks at least in order to be effective. Thus, the reduction of chemicals and energy for thermal processing is a target of our current research. Liquid hot water (LHW) and solvent-based pretreatment (OrganoSolv) require more complex equipment, as they depend on high temperatures (160 - 180 °C) and enhanced pressure (up to 20 bar). However, they prove to be promising processes in regard to the fractioning of lignocellulose. For optimal lignin recovery the parameters differ from those established in cellulose extraction. A novel screening system scaled down to a reaction volume of 100 mL has been developed and successfully tested for this purpose.}, language = {en} } @misc{RossJonesTeumerCapitainetal.2018, author = {Ross-Jones, J. and Teumer, T. and Capitain, C. and Tippk{\"o}tter, Nils and Krause, M. J. and Methner, F.-J. and R{\"a}dle, M.}, title = {Analytical methods for in-line characterization of beer haze}, series = {Trends in Brewing}, journal = {Trends in Brewing}, year = {2018}, abstract = {In most beers, producers strive to minimize haze to maximize visual appeal. To detect the formation of particulates, a measurement system for sub-micron particles is required. Beer haze is naturally occurring, composed of protein or polyphenol particles; in their early stage of growth their size is smaller than 2 µm. Microscopy analysis is time and resource intensive; alternatively, backscattering is an inexpensive option for detecting particle sizes of interest.}, language = {en} } @misc{FrauenrathPfeifferHezeletal.2012, author = {Frauenrath, Tobias and Pfeiffer, Harald and Hezel, Fabian and Dieringer, Matthias A. and Winter, Lukas and Gr{\"a}ßl, Andreas and Santoro, Davide and {\"O}zerdem, Celal and Renz, Wolfgang and Greiser, Andreas and Niendorf, Thoralf}, title = {Lessons learned from cardiac MRI at 7.0 T: LV function assessment at 3.0 T using local multi-channel transceiver coil arrays}, series = {2012 ISMRM Annual Meeting Proceedings}, journal = {2012 ISMRM Annual Meeting Proceedings}, issn = {1545-4428}, year = {2012}, abstract = {Cardiac MR (CMR) is of proven clinical value but also an area of vigorous ongoing research since image quality is not always exclusively defined by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Recent developments of CMR at 7.0 T have been driven by pioneering explorations into novel multichannel transmit and receive coil array technology to tackle the challenges B1+-field inhomogeneities, to offset specific-absorption rate (SAR) constraints and to reduce banding artifacts in SSFP imaging. For this study, recognition of the benefits and performance of local surface Tx/Rx-array structures recently established at 7.0 T inspired migration to 3.0 T, where RF inhomogeneities and SAR limitations encountered in routine clinical CMR, though somewhat reduced versus the 7.0 T situation, remain significant. For all these reasons, this study was designed to build and examine the feasibility of a local four channel Tx/Rx cardiac coil array for anatomical and functional cardiac imaging at 3.0 T. For comparison, a homebuilt 4 channel Rx cardiac coil array exhibiting the same geometry as the Tx/Rx coil and a Rx surface coil array were used.}, language = {en} } @misc{FrauenrathFuchsHezeletal.2012, author = {Frauenrath, Tobias and Fuchs, Katharina and Hezel, Fabian and Dieringer, Matthias A. and Rieger, Jan and Niendorf, Thoralf}, title = {Improved cardiac triggering by combining multiple physiological signals: a cardiac MR feasibility study at 7.0 T}, series = {2012 ISMRM Annual Meeting Proceedings}, journal = {2012 ISMRM Annual Meeting Proceedings}, issn = {1545-4428}, year = {2012}, abstract = {In current clinical cardiovascular MR (CMR) practice cardiac motion is commonly dealt with using ECG based synchronization. However, ECG is corrupted by magneto-hydrodynamic (MHD) effects in magnetic fields. This leads to artifacts in the ECG trace and evokes severe T-wave elevations, which might be misinterpreted as R-waves resulting in erroneous triggering. At (ultra)high field strengths, the propensity of ECG recordings to MHD effects is further pronounced. Pulse oximetry (POX) being inherently sensitive to blood oxygenation provides an alternative approach for cardiac gating. However, due to the travel time of the blood the peak of maximum oxygenation and hence the trigger is delayed by approx. 300 ms with respect to the ECG's R-wave. Also the peak of maximum oxygenation shows a jitter of up to 65 ms. Alternative triggering approaches include acoustic cardiac triggering (ACT). In current clinical practice cardiac gating / triggering commonly relies on using single physiological signals only. Realizing this limitation this study proposes a combined triggering approach which exploits multiple physiological signals including ECG, POX or ACT to track cardiac activity. The feasibility of the coupled approach is examined for LV function assessment at 7.0 T. For this purpose, breath-held 2D-CINE imaging in conjunction with cardiac synchronization was performed paralleled by real time logging of physiological waveforms to track (mis)synchronization between the cardiac cycle and data acquisition. Combinations of the ECG, POX and ACT signals were evaluated and processed in real time to facilitate reliable trigger information.}, language = {en} } @misc{TkachenkovonKnobelsdorffBrenkenhoffKleindienstetal.2012, author = {Tkachenko, Valeriy and von Knobelsdorff-Brenkenhoff, Florian and Kleindienst, Denise and Winter, Lukas and Rieger, Jan and Frauenrath, Tobias and Dieringer, Matthias A. and Santoro, Davide and Niendorf, Thoralf and Schulz-Menger, Jeanette}, title = {Cardiovasular MR at 7Tesla: assessment of the right ventricle}, series = {2012 ISMRM Annual Meeting Proceedings}, journal = {2012 ISMRM Annual Meeting Proceedings}, issn = {1545-4428}, year = {2012}, abstract = {The assessment of the right ventricle (RV) is a challenge in today's cardiology, but of growing clinical impact regarding patient prognosis in different cardiac diseases. The detection and differentiation of small wall motion abnormalities may help to enhance the differentiation of cardiomyopathies including Arrhythmogenic Rightventricular Cardiomyopathy. Cardiovascular magnetic resonance (CMR) at 1.5T is the accepted gold standard for RV quantification. The higher spatial resolution achievable at ultrahigh field strength (UHF) offers the potential to gain new insights into the structure and function of the RV. To approach this goal accurate RV chamber quantification at 7T has to be proven. Consequently this study examines the feasibility of assessment of RV dimensions and function at 7T using improved spatial resolution enabled by the intrinsic sensitivity gain of UHF CMR. For this purpose, a dedicated 16 channel TX/RX RF coil array is used together with 2D CINE fast gradient echo (FGRE) imaging. For comparison RV chamber quantification is conducted at 1.5T using a SSFP based state of the art clinical protocol.}, language = {en} } @misc{GraesslRenzHezeletal.2012, author = {Gr{\"a}ßl, Andreas and Renz, Wolfgang and Hezel, Fabian and Frauenrath, Tobias and Pfeiffer, Harald and Hoffmann, Werner and Kellmann, Peter and Martin, Conrad and Niendorf, Thoralf}, title = {Design, evaluation and application of a modular 32 channel transmit/receive surface coil array for cardiac MRI at 7T}, series = {2012 ISMRM Annual Meeting Proceedings}, journal = {2012 ISMRM Annual Meeting Proceedings}, issn = {1545-4428}, year = {2012}, abstract = {Cardiac MR (CMR) at ultrahigh (≥7.0 T) fields is regarded as one of the most challenging MRI applications. At 7.0 T image quality is not always exclusively defined by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Detrimental effects bear the potential to spoil the signal-to-noise (SNR) and contrast-to-noise (CNR) benefits of cardiac MR (CMR) at 7.0 T. B₁⁺-inhomogeneities and signal voids represent the main challenges. Various pioneering coil concepts have been proposed to tackle these issues, enabling cardiac MRI at 7.0 T. This includes a trend towards an ever larger number of transmit and receive channels. This approach affords multi-dimensional B₁⁺ modulations to improve B₁⁺ shimming performance and to enhance RF efficiency. Also, parallel imaging benefits from a high number of receive channels enabling two-dimensional acceleration. Realizing the limitations of existing coil designs tailored for UHF CMR and recognizing the opportunities of a many element TX/RX channel architecture this work proposes a modular, two dimensional 32-channel transmit and receive array using loop elements and examines its efficacy for enhanced B¹+ homogeneity and improved parallel imaging performance.}, language = {en} } @misc{TippkoetterUlber2009, author = {Tippk{\"o}tter, Nils and Ulber, Roland}, title = {Eine magnetische horizontale Wirbelschicht f{\"u}r die Durchmischung und R{\"u}ckhaltung von magnetisierbaren Mikropartikeln im Durchfluss}, series = {Chemie Ingenieur Technik}, volume = {81}, journal = {Chemie Ingenieur Technik}, number = {8}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.200950076}, pages = {1168}, year = {2009}, abstract = {Magnetisierbare Partikel als Tr{\"a}ger von Katalysatoren k{\"o}nnen durch Anlegen eines magnetisches Feldes einfach und schnell abgetrennt werden. Die Wiedergewinnung von wertvollen Enzymen unter geringem Energie- und Materialeinsatz der magnetischen Abtrennung er{\"o}ffnet einen Wettbewerbsvorteil f{\"u}r Produktionsprozesse. Die Abtrennung von magnetisierbaren Partikeln vom {\"U}berstand wird {\"u}blicherweise entweder durch Anlegen eines {\"a}ußeren Magnetfelds und der resultierenden Ablagerung der Partikel an den Reaktorw{\"a}nden oder durch Hochgradientenmagnetseparation (HGMS)durchgef{\"u}hrt. Beide Verfahren resultieren meist in der Bildung eines Filterkuchens aus Magnetpartikeln und den Feststoffen des Reaktionsmediums. Das magnetische horizontale Wirbelbett erm{\"o}glicht simultan eine kontinuierliche Reaktionsf{\"u}hrung und die R{\"u}ckhaltung der Partikel im Durchfluss. Die Partikelsuspension fließt durch einen Rohrreaktor, der in einem Magnetfeld mit wechselnden Feldgradienten eingebracht ist. Die {\"A}nderung des Magnetfeldgradienten erfolgt entgegen der Str{\"o}mungsrichtung der Reaktionsl{\"o}sung. Durch alternierende Feldmaxima an den beiden Seiten des Reaktors werden die magnetisierbaren Partikel zu dessen W{\"a}nden gezogen. Bei Umkehrung des Feldes wandern die Partikel an die gegen{\"u}berliegende Reaktorwand. Durch Wahl einer geeigneten Wechselfrequenz kann eine kontinuierliche Durchmischung und R{\"u}ckhaltung der Mikropartikel im durchstr{\"o}mten Rohr erreicht werden. Somit k{\"o}nnen Immobilisierungsreaktionen und Biotransformationen mit den Partikelsystemen im Durchfluss durchgef{\"u}hrt werden.}, language = {en} } @article{GraesslRenzHezeletal.2013, author = {Gr{\"a}ßl, Andreas and Renz, Wolfgang and Hezel, Fabian and Dieringer, Matthias A. and Winter, Lukas and {\"O}zerdem, Celal and Rieger, Jan and Kellmann, Peter and Santoro, Davide and Lindel, Tomasz D. and Frauenrath, Tobias and Pfeiffer, Harald and Niendorf, Thoralf}, title = {Modular 32-channel transceiver coil array for cardiac MRI at 7.0T}, series = {Magnetic Resonance in Medicine}, volume = {72}, journal = {Magnetic Resonance in Medicine}, number = {1}, publisher = {Wiley-Liss}, address = {New York}, issn = {1522-2594}, doi = {10.1002/mrm.24903}, pages = {276 -- 290}, year = {2013}, abstract = {Purpose To design and evaluate a modular transceiver coil array with 32 independent channels for cardiac MRI at 7.0T. Methods The modular coil array comprises eight independent building blocks, each containing four transceiver loop elements. Numerical simulations were used for B1+ field homogenization and radiofrequency (RF) safety validation. RF characteristics were examined in a phantom study. The array's suitability for accelerated high spatial resolution two-dimensional (2D) FLASH CINE imaging of the heart was examined in a volunteer study. Results Transmission field adjustments and RF characteristics were found to be suitable for the volunteer study. The signal-to-noise intrinsic to 7.0T together with the coil performance afforded a spatial resolution of 1.1 × 1.1 × 2.5 mm3 for 2D CINE FLASH MRI, which is by a factor of 6 superior to standardized CINE protocols used in clinical practice at 1.5T. The 32-channel transceiver array supports one-dimensional acceleration factors of up to R = 4 without impairing image quality significantly. Conclusion The modular 32-channel transceiver cardiac array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0T.}, language = {en} }