@inproceedings{ZischankKernFrentzeletal.2000, author = {Zischank, Wolfgang J. and Kern, Alexander and Frentzel, Ralf and Heidler, Fridolin and Seevers, M.}, title = {Assessment of the lightning transient coupling to control cables interconnecting structures in large industrial facilities and power plants}, year = {2000}, abstract = {Large industrial facilities and power plants often require a huge number fo information and control cables between the differnet structures. These I\&C-cables can be routed in reinforced concrete cable ducts or in isolated buried cable runs. KTA 2206 is the German lightning protection standard for nuclear power plants. During the last several years considerable effort has been made to revise this standard. Despite the well established principles and design guidelines for the construction of the lightning protection system, this standard puts special emphasis on the coupling of transient overvoltages to I\&C-cables.}, language = {en} } @inproceedings{ZischankHeidlerWiesingeretal.2004, author = {Zischank, Wolfgang J. and Heidler, Fridolin and Wiesinger, J. and Stimper, K. and Kern, Alexander and Seevers, M.}, title = {Magnetic Fields and Induced Voltages inside LPZ 1 Measured at a 1:6 Scale Model Building}, year = {2004}, abstract = {Laborexperimente zu Blitzschutzzonen in Stahlbetongeb{\"a}uden anhand eines Modells im Maßstab 1:6}, language = {en} } @inproceedings{ZischankHeidlerKernetal.2002, author = {Zischank, Wolfgang J. and Heidler, Fridolin and Kern, Alexander and Metwally, I. A. and Wiesinger, J. and Seevers, M.}, title = {Laboratory simulation of direct lightning strokes to a modelled building - measurement of magnetic fields and induced voltages}, year = {2002}, abstract = {In IEC 61312-2 equations for the assessment of the magnetic fields inside structures due to a direct lightning strike are given. These equations are based on computer simulations for shields consisting of a single-layer steel grid of a given mesh width. Real constructions, however, contain at least two layers of reinforcement steel grids. The objective of this study was to experimentally determine the additional shielding effectiveness of a second reinforcement layer compared to a single-layer grid. To this end, simulated structures were set up in the high current laboratory. The structures consisted of cubic cages of 2 m side length with one or with two reinforcement grids, respectively. The structures were exposed to direct lightning currents representing the variety of anticipated lightning current waveforms. The magnetic fields and their derivatives at several positions inside the structure as well as the voltage between "floor" and "roof" in the center were determined for different current injection points. From these data the improvement of the shielding caused by a second reinforcement layer is derived.}, language = {en} } @inproceedings{Wessling2007, author = {Weßling, Matthias}, title = {Leadership Perspectives: Research Findings, Theories, Practical Experiences}, year = {2007}, abstract = {Leadership Perspectives: Research Findings, Theories, Practical Experiences: Results of Leadership Research and exemplarily application cases show the perspectives and consequences for leadership practice and the following requirements for executives in future.}, subject = {Leadership}, language = {en} } @inproceedings{Wessling2007, author = {Weßling, Matthias}, title = {Motivation and Leadership - The Reiss-Profile of the 16 Basic Desires: Research results and managerial applications}, year = {2007}, abstract = {Recent Results of the scientific Reiss-Profile (16 basic desires) due to the concept of Prof. Dr. Steven Reiss (State University Ohio, U.S.A.), supplemented by the comparative analysis of empirical motivational profiles of european executives of various companies.}, subject = {Motivation}, language = {en} } @inproceedings{Wessling2007, author = {Weßling, Matthias}, title = {Provocative Communication in Coaching and Leadership: scientific research and managerial applications of the Provocative Communication Style}, year = {2007}, abstract = {Concept, scientific research and managerial applications of Provocative Coaching, according to the „Provocative Therapy" of Prof. Dr. Frank Farrelly (University of Wisconsin, U.S.A) in terms of an application of the Provocative Communication Style in specific situations of practical leadership, especially in the role of a coach for their subordinates.}, subject = {Kommunikation}, language = {en} } @inproceedings{WagnerSchoening2006, author = {Wagner, Torsten and Sch{\"o}ning, Michael Josef}, title = {Preface of the Special Issue of I3S 2005 in J{\"u}lich (Germany)}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1365}, year = {2006}, abstract = {International Symposium on Sensor Science, I3S 2005 <3; 2005; Juelich, Germany> In: Sensors 2006, 6, 260-261 ISSN 1424-8220}, subject = {Biosensor}, language = {en} } @inproceedings{WagnerKohlFroebaetal.2006, author = {Wagner, Thorsten and Kohl, Claus-Dieter and Fr{\"o}ba, Michael and Tiemann, Michael}, title = {Gas sensing properties of ordered mesoporous SnO2}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1422}, year = {2006}, abstract = {We report on the synthesis and CO gas-sensing properties of mesoporous tin(IV) oxides (SnO2). For the synthesis cetyltrimethylammonium bromide (CTABr) was used as a structure-directing agent; the resulting SnO2 powders were applied as films to commercially available sensor substrates by drop coating. Nitrogen physisorption shows specific surface areas up to 160 m2·g-1 and mean pore diameters of about 4 nm, as verified by TEM. The film conductance was measured in dependence on the CO concentration in humid synthetic air at a constant temperature of 300 °C. The sensors show a high sensitivity at low CO concentrations and turn out to be largely insensitive towards changes in the relative humidity. We compare the materials with commercially available SnO2-based sensors.}, subject = {Biosensor}, language = {en} } @inproceedings{UibelBlass2010, author = {Uibel, Thomas and Blaß, Hans Joachim}, title = {Determining Suitable Spacings and Distances for Self-tapping Screws by Experimental and Numerical Studies}, series = {Proceedings of the 11th World Conference on Timber Engineering, WCTE 2010 : World Conference on Timber Engineering; [June 20 - 24, 2010, Riva del Garda, Trento, Italy] . Vol. III, Riva del Garda, Italy 2010}, booktitle = {Proceedings of the 11th World Conference on Timber Engineering, WCTE 2010 : World Conference on Timber Engineering; [June 20 - 24, 2010, Riva del Garda, Trento, Italy] . Vol. III, Riva del Garda, Italy 2010}, editor = {Cecotti, A.}, pages = {669 -- 670}, year = {2010}, language = {en} } @inproceedings{UibelBlass2010, author = {Uibel, Thomas and Blaß, Hans Joachim}, title = {A new method to determine suitable spacings and distances for self-tapping screws}, series = {Meeting ... / International Council for Research and Innovation in Building and Construction, Working Commission W18 - Timber Structures}, volume = {43}, booktitle = {Meeting ... / International Council for Research and Innovation in Building and Construction, Working Commission W18 - Timber Structures}, publisher = {Lehrstuhl f{\"u}r Ingenieurholzbau und Baukonstruktionen}, address = {Karlsruhe}, issn = {1864-1784}, year = {2010}, abstract = {The determination of spacing, edge and end distance requirements for self-tapping screws requires numerous and comprehensive insertion tests. Yet the results of such tests cannot be transferred to other types of screws or even to screws of different diameter because of differences in shape or geometry. To reduce the effort of insertion tests a new method was developed which allows the estimation of required spacings, distances and timber thickness.}, language = {en} }