@article{KleefeldZimmermann2022, author = {Kleefeld, Andreas and Zimmermann, M.}, title = {Computing Elastic Interior Transmission Eigenvalues}, series = {Integral Methods in Science and Engineering}, journal = {Integral Methods in Science and Engineering}, editor = {Constanda, Christian and Bodmann, Bardo E.J. and Harris, Paul J.}, publisher = {Birkh{\"a}user}, address = {Cham}, isbn = {978-3-031-07171-3}, doi = {10.1007/978-3-031-07171-3_10}, pages = {139 -- 155}, year = {2022}, abstract = {An alternative method is presented to numerically compute interior elastic transmission eigenvalues for various domains in two dimensions. This is achieved by discretizing the resulting system of boundary integral equations in combination with a nonlinear eigenvalue solver. Numerical results are given to show that this new approach can provide better results than the finite element method when dealing with general domains.}, language = {en} } @article{PourshahidiAchtsnichtOffenhaeusseretal.2022, author = {Pourshahidi, Ali Mohammad and Achtsnicht, Stefan and Offenh{\"a}usser, Andreas and Krause, Hans-Joachim}, title = {Frequency Mixing Magnetic Detection Setup Employing Permanent Ring Magnets as a Static Offset Field Source}, series = {Sensors}, volume = {22}, journal = {Sensors}, number = {22}, editor = {Offenh{\"a}usser, Andreas}, publisher = {MDPI}, address = {Basel}, issn = {1424-8220}, doi = {10.3390/s22228776}, pages = {12 Seiten}, year = {2022}, abstract = {Frequency mixing magnetic detection (FMMD) has been explored for its applications in fields of magnetic biosensing, multiplex detection of magnetic nanoparticles (MNP) and the determination of core size distribution of MNP samples. Such applications rely on the application of a static offset magnetic field, which is generated traditionally with an electromagnet. Such a setup requires a current source, as well as passive or active cooling strategies, which directly sets a limitation based on the portability aspect that is desired for point of care (POC) monitoring applications. In this work, a measurement head is introduced that involves the utilization of two ring-shaped permanent magnets to generate a static offset magnetic field. A steel cylinder in the ring bores homogenizes the field. By variation of the distance between the ring magnets and of the thickness of the steel cylinder, the magnitude of the magnetic field at the sample position can be adjusted. Furthermore, the measurement setup is compared to the electromagnet offset module based on measured signals and temperature behavior.}, language = {en} } @article{RoethenbacherCesariDoppleretal.2022, author = {R{\"o}thenbacher, Annika and Cesari, Matteo and Doppler, Christopher E.J. and Okkels, Niels and Willemsen, Nele and Sembowski, Nora and Seger, Aline and Lindner, Marie and Brune, Corinna and Stefani, Ambra and H{\"o}gl, Birgit and Bialonski, Stephan and Borghammer, Per and Fink, Gereon R. and Schober, Martin and Sommerauer, Michael}, title = {RBDtector: an open-source software to detect REM sleep without atonia according to visual scoring criteria}, series = {Scientific Reports}, volume = {12}, journal = {Scientific Reports}, number = {Article number: 20886}, publisher = {Springer Nature}, address = {London}, issn = {2045-2322}, doi = {10.1038/s41598-022-25163-9}, pages = {1 -- 14}, year = {2022}, abstract = {REM sleep without atonia (RSWA) is a key feature for the diagnosis of rapid eye movement (REM) sleep behaviour disorder (RBD). We introduce RBDtector, a novel open-source software to score RSWA according to established SINBAR visual scoring criteria. We assessed muscle activity of the mentalis, flexor digitorum superficialis (FDS), and anterior tibialis (AT) muscles. RSWA was scored manually as tonic, phasic, and any activity by human scorers as well as using RBDtector in 20 subjects. Subsequently, 174 subjects (72 without RBD and 102 with RBD) were analysed with RBDtector to show the algorithm's applicability. We additionally compared RBDtector estimates to a previously published dataset. RBDtector showed robust conformity with human scorings. The highest congruency was achieved for phasic and any activity of the FDS. Combining mentalis any and FDS any, RBDtector identified RBD subjects with 100\% specificity and 96\% sensitivity applying a cut-off of 20.6\%. Comparable performance was obtained without manual artefact removal. RBD subjects also showed muscle bouts of higher amplitude and longer duration. RBDtector provides estimates of tonic, phasic, and any activity comparable to human scorings. RBDtector, which is freely available, can help identify RBD subjects and provides reliable RSWA metrics.}, language = {en} } @article{SavitskayaZhantlessovaKistaubayevaetal.2023, author = {Savitskaya, Irina and Zhantlessova, Sirina and Kistaubayeva, Aida and Ignatova, Ludmila and Shokatayeva, Dina and Sinyavsky, Yuriy and Kushugulova, Almagul and Digel, Ilya}, title = {Prebiotic cellulose-pullulan matrix as a "vehicle" for probiotic biofilm delivery to the host large intestine}, series = {Polymers}, journal = {Polymers}, number = {16(1)}, publisher = {MDPI}, address = {Basel}, doi = {10.3390/polym16010030}, pages = {Artikel 30}, year = {2023}, abstract = {This study describes the development of a new combined polysaccharide-matrix-based technology for the immobilization of Lactobacillus rhamnosus GG (LGG) bacteria in biofilm form. The new composition allows for delivering the bacteria to the digestive tract in a manner that improves their robustness compared with planktonic cells and released biofilm cells. Granules consisting of a polysaccharide matrix with probiotic biofilms (PMPB) with high cell density (>9 log CFU/g) were obtained by immobilization in the optimized nutrient medium. Successful probiotic loading was confirmed by fluorescence microscopy and scanning electron microscopy. The developed prebiotic polysaccharide matrix significantly enhanced LGG viability under acidic (pH 2.0) and bile salt (0.3\%) stress conditions. Enzymatic extract of feces, mimicking colon fluid in terms of cellulase activity, was used to evaluate the intestinal release of probiotics. PMPB granules showed the ability to gradually release a large number of viable LGG cells in the model colon fluid. In vivo, the oral administration of PMPB granules in rats resulted in the successful release of probiotics in the colon environment. The biofilm-forming incubation method of immobilization on a complex polysaccharide matrix tested in this study has shown high efficacy and promising potential for the development of innovative biotechnologies.}, language = {en} } @inproceedings{KoellenspergerBragardPlumetal.2007, author = {K{\"o}llensperger, P. and Bragard, Michael and Plum, T. and De Doncker, R. W.}, title = {The dual GCT : a new high-power device using optimized GCT technology}, series = {Conference record of the 2007 IEEE Industry Applications Conference : 42. IAS annual meeting ; September 23 - 27, 2007, New Orleans, Louisiana, USA}, booktitle = {Conference record of the 2007 IEEE Industry Applications Conference : 42. IAS annual meeting ; September 23 - 27, 2007, New Orleans, Louisiana, USA}, publisher = {IEEE Operations Center}, address = {Piscataway, NJ}, isbn = {978-1-4244-1260-0 (Online)}, doi = {10.1109/07IAS.2007.76}, pages = {358 -- 365}, year = {2007}, language = {en} } @article{HendersonMclaughlinScheeretal.2015, author = {Henderson, Colin J. and Mclaughlin, Lesley A. and Scheer, Nico and Stanley, Lesley A. and Wolf, C. Roland}, title = {Cytochrome b5 Is a Major Determinant of Human Cytochrome P450 CYP2D6 and CYP3A4 Activity In Vivo s}, series = {Molecular Pharmacology}, volume = {87}, journal = {Molecular Pharmacology}, number = {4}, publisher = {ASPET}, address = {Bethesda}, issn = {1521-0111}, doi = {10.1124/mol.114.097394}, pages = {733 -- 739}, year = {2015}, language = {en} } @article{KapelyukhHendersonScheeretal.2019, author = {Kapelyukh, Yury and Henderson, Colin James and Scheer, Nico and Rode, Anja and Wolf, Charles Roland}, title = {Defining the contribution of CYP1A1 and CYP1A2 to drug metabolism using humanized CYP1A1/1A2 and Cyp1a1/Cyp1a2 KO mice}, series = {Drug Metabolism and Disposition}, journal = {Drug Metabolism and Disposition}, number = {Early view}, doi = {10.1124/dmd.119.087718}, pages = {43 Seiten}, year = {2019}, language = {en} } @book{GebhardtKesslerThurn2019, author = {Gebhardt, Andreas and Kessler, Julia and Thurn, Laura}, title = {3D printing : understanding additive manufacturing}, edition = {2. Auflage}, publisher = {Hanser}, address = {M{\"u}nchen}, isbn = {978-1-56990-702-3}, pages = {XVI, 204 Seiten}, year = {2019}, language = {en} } @phdthesis{Bragard2012, author = {Bragard, Michael}, title = {The integrated emitter turn-off thyristor : an innovative MOS-gated high-power device. - (Aachener Beitr{\"a}ge des ISEA ; 62)}, publisher = {Shaker}, address = {Aachen}, isbn = {978-3-8440-1152-4}, pages = {III, 164 S. : Ill., graph. Darst.}, year = {2012}, abstract = {This thesis introduces the Integrated Emitter Turn-Off (IETO) Thyristor as a new high-power device. Known state-of-the-art research activities like the Dual GCT, the ETO thyristor and the ICT were presented and critically reviewed. A comparison with commercialized solutions identifies the pros and cons of each type of device family. Based on this analysis, the IETO structure is proposed, covering most benefits of each device class. In particular the combination of a MOS-assisted turn-off with a thyristor-based device allows a voltage-controlled MOS switching and the low on-state voltage of the thyristors. The following synthesis of an IETO device stands on a three-dimensional field of optimization spanned by electric, mechanical and thermal aspects. From an electric point of view, the lowest possible parasitic inductance and resistance within the commutation path are optimization criteria. The mechanical construction has to withstand the required contact pressure of multiple kilo Newtons. Finally, thermal borders limit the maximum average current of the device. FEM simulations covering these three aspects are performed for several design proposals. An IETO prototype is constructed and measurements on various test benches attest thermal, mechanical and electric performance. A local decoupling of the external driver stage and the presspack housing is presented by a cable connection. This separation enables a thermal and mechanical independence, which is advantageous in terms of vibrations and thermal cycles including increased reliability. The electric pulse performance of the prototype device is a factor of 3.1 above today''s solutions. In single-pulse measurements, a current up to 1600 A was successfully turned off at 115°C with an active silicon area of 823 mm². One reason for this increased turn-off capability is the extremely low-inductive construction. Additional functionality of the IETO thyristor like over-current self-protection and defined short-circuit failure state are successfully verified.}, language = {en} } @article{vonKnobelsdorfBrenkenhoffFrauenrathProthmannetal.2010, author = {von Knobelsdorf-Brenkenhoff, Florian and Frauenrath, Tobias and Prothmann, Marcel and Dieringer, Matthias A. and Hezel, Fabian and Renz, Wolfgang and Kretschel, Kerstin and Niendorf, Thoralf and Schulz-Menger, Jeanette}, title = {Cardiac chamber quantification using magnetic resonance imaging at 7 Tesla—a pilot study}, volume = {20}, publisher = {Springer}, address = {Berlin, Heidelberg}, issn = {0938-7994}, doi = {10.1007/s00330-010-1888-2}, pages = {2844 -- 2852}, year = {2010}, abstract = {Objectives Interest in cardiovascular magnetic resonance (CMR) at 7 T is motivated by the expected increase in spatial and temporal resolution, but the method is technically challenging. We examined the feasibility of cardiac chamber quantification at 7 T. Methods A stack of short axes covering the left ventricle was obtained in nine healthy male volunteers. At 1.5 T, steady-state free precession (SSFP) and fast gradient echo (FGRE) cine imaging with 7 mm slice thickness (STH) were used. At 7 T, FGRE with 7 mm and 4 mm STH were applied. End-diastolic volume, end-systolic volume, ejection fraction and mass were calculated. Results All 7 T examinations provided excellent blood/myocardium contrast for all slice directions. No significant difference was found regarding ejection fraction and cardiac volumes between SSFP at 1.5 T and FGRE at 7 T, while volumes obtained from FGRE at 1.5 T were underestimated. Cardiac mass derived from FGRE at 1.5 and 7 T was larger than obtained from SSFP at 1.5 T. Agreement of volumes and mass between SSFP at 1.5 T and FGRE improved for FGRE at 7 T when combined with an STH reduction to 4 mm. Conclusions This pilot study demonstrates that cardiac chamber quantification at 7 T using FGRE is feasible and agrees closely with SSFP at 1.5 T.}, language = {en} }