@article{JungStaatMueller2018, author = {Jung, Alexander and Staat, Manfred and M{\"u}ller, Wolfram}, title = {Corrigendum to "Flight style optimization in ski jumping on normal, large, and ski flying hills" [J. Biomech 47 (2014) 716-722]}, series = {Journals of Biomechanics}, journal = {Journals of Biomechanics}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0021-9290}, doi = {10.1016/j.jbiomech.2018.02.001}, pages = {313}, year = {2018}, language = {en} } @inproceedings{KahmannUschokWegmannetal.2018, author = {Kahmann, Stephanie Lucina and Uschok, Stephan and Wegmann, Kilian and M{\"u}ller, Lars-P. and Staat, Manfred}, title = {Biomechanical multibody model with refined kinematics of the elbow}, series = {6th European Conference on Computational Mechanics (ECCM 6), 7th European Conference on Computational Fluid Dynamics (ECFD 7), 11-15 June 2018, Glasgow, UK}, booktitle = {6th European Conference on Computational Mechanics (ECCM 6), 7th European Conference on Computational Fluid Dynamics (ECFD 7), 11-15 June 2018, Glasgow, UK}, pages = {11 Seiten}, year = {2018}, abstract = {The overall objective of this study is to develop a new external fixator, which closely maps the native kinematics of the elbow to decrease the joint force resulting in reduced rehabilitation time and pain. An experimental setup was designed to determine the native kinematics of the elbow during flexion of cadaveric arms. As a preliminary study, data from literature was used to modify a published biomechanical model for the calculation of the joint and muscle forces. They were compared to the original model and the effect of the kinematic refinement was evaluated. Furthermore, the obtained muscle forces were determined in order to apply them in the experimental setup. The joint forces in the modified model differed slightly from the forces in the original model. The muscle force curves changed particularly for small flexion angles but their magnitude for larger angles was consistent.}, language = {en} } @article{KampkerSchleserTriebsetal.2018, author = {Kampker, Achim and Schleser, Markus and Triebs, Johannes and Berg, Alexander-Karl and Hansen, Jan Ole and Fiedler, Falko}, title = {Bauteilintegrierte Vorrichtungsfunktionen im Karosseriebau : Aktuelle Ergebnisse im Forschungsprojekt ProeK}, series = {ZWF Zeitschrift f{\"u}r wirtschaftlichen Fabrikbetrieb}, volume = {113}, journal = {ZWF Zeitschrift f{\"u}r wirtschaftlichen Fabrikbetrieb}, number = {11}, publisher = {De Gruyter}, address = {Berlin}, issn = {0947-0085}, doi = {10.3139/104.112012}, pages = {767 -- 770}, year = {2018}, abstract = {Das Forschungsprojekt Produktionseffizienz in der Kleinserie (ProeK) erarbeitet kosteng{\"u}nstige und effiziente L{\"o}sungsans{\"a}tze f{\"u}r Prozessketten im Zukunftsfeld der Elektromobilit{\"a}t. Das Teilprojekt Karosserie setzt diese Zielsetzung durch innovative und praxisorientierte Produkt- und Prozesskonzepte mit neuartigen bauteilintegrierten Vorrichtungsfunktionen (BiV) um. Im Teilprojekt Außenhaut sollen Toleranzen adaptiv durch Anpassungen der Prozessparameter sowie Bauteilmanipulation kompensiert werden.}, language = {de} } @phdthesis{Keinz2018, author = {Keinz, Jan}, title = {Optimization of a Dry Low NOx Micromix Combustor for an Industrial Gas Turbine Using Hydrogen-Rich Syngas Fuel}, publisher = {Universit{\´e} Libre de Bruxelles - Brussels School of Engineering Aero-Thermo-Mechanics}, address = {Br{\"u}ssel}, year = {2018}, language = {en} } @article{KetelhutGoellBraunsteinetal.2018, author = {Ketelhut, Maike and G{\"o}ll, Fabian and Braunstein, Bj{\"o}rn and Albracht, Kirsten and Abel, Dirk}, title = {Comparison of different training algorithms for the leg extension training with an industrial robot}, series = {Current Directions in Biomedical Engineering}, volume = {4}, journal = {Current Directions in Biomedical Engineering}, number = {1}, publisher = {De Gruyter}, address = {Berlin}, issn = {2364-5504}, doi = {10.1515/cdbme-2018-0005}, pages = {17 -- 20}, year = {2018}, abstract = {In the past, different training scenarios have been developed and implemented on robotic research platforms, but no systematic analysis and comparison have been done so far. This paper deals with the comparison of an isokinematic (motion with constant velocity) and an isotonic (motion against constant weight) training algorithm. Both algorithms are designed for a robotic research platform consisting of a 3D force plate and a high payload industrial robot, which allows leg extension training with arbitrary six-dimensional motion trajectories. In the isokinematic as well as the isotonic training algorithm, individual paths are defined i n C artesian s pace by sufficient s upport p oses. I n t he i sotonic t raining s cenario, the trajectory is adapted to the measured force as the robot should only move along the trajectory as long as the force applied by the user exceeds a minimum threshold. In the isotonic training scenario however, the robot's acceleration is a function of the force applied by the user. To validate these findings, a simulative experiment with a simple linear trajectory is performed. For this purpose, the same force path is applied in both training scenarios. The results illustrate that the algorithms differ in the force dependent trajectory adaption.}, language = {en} } @article{KeutmannStaatLaack2018, author = {Keutmann, Sabine and Staat, Manfred and Laack, Walter van}, title = {Untersuchung der thermischen Auswirkung von therapeutischem Ultraschall}, volume = {7}, number = {10}, publisher = {Deutscher {\"A}rzte-Verl.}, address = {K{\"o}ln}, issn = {2193-5793}, pages = {518 -- 522}, year = {2018}, abstract = {Zusammenfassung: In der Orthop{\"a}die z{\"a}hlt der therapeutische Ultraschall als Mittel zur Pr{\"a}vention und Therapiebegleitung. Er hat mechanische, thermische und physiko-chemische Auswirkungen auf den menschlichen K{\"o}rper. Um mehr Erkenntnisse {\"u}ber die thermischen Auswirkungen zu erlangen, wurden Versuche an einem Hydrogel-Phantom und an Probanden durchgef{\"u}hrt. Dabei entstand eine signifikante Erw{\"a}rmung des Gewebes, welche beim Probandenversuch an der Oberfl{\"a}che und beim Hydrogelversuch in der Tiefe gemessen wurde. Summary: In orthopaedics, therapeutic ultrasound is a tool of prevention and therapy support. It has mechanical, thermal and physico-chemical effects on the human body. Tests with a hydrogel phantom and with human probands have been performed in order to obtain more knowledge about their thermal effects. Both tests measured temperature increases in cell tissue, on the surface with the human proband test and in depth with the hydrogel phantom test.}, language = {de} } @incollection{Klocke2018, author = {Klocke, Martina}, title = {Schulter an Schulter - Zusammenarbeit in einem differenzierten Hochschulsystem}, series = {Lehre und Lehrentwicklung an Fachhochschulen - Festschrift f{\"u}r Prof. Dr. med. W. Huhn}, booktitle = {Lehre und Lehrentwicklung an Fachhochschulen - Festschrift f{\"u}r Prof. Dr. med. W. Huhn}, publisher = {Waxmann}, address = {M{\"u}nster}, isbn = {978-3-8309-3782-1}, pages = {75 -- 80}, year = {2018}, language = {de} } @article{KlockeRichertSube2018, author = {Klocke, Martina and Richert, Vera and Sube, Maike}, title = {Vier Jahre „Guter Studienstart im Ingenieurbereich": Entwicklung und Perspektiven des „Nullten Semesters" in Aachen}, series = {Zeitschrift f{\"u}r Beratung und Studium}, volume = {13}, journal = {Zeitschrift f{\"u}r Beratung und Studium}, number = {1}, publisher = {Universit{\"a}tsverlag Webler}, address = {Bielefeld}, issn = {1860-3068}, pages = {17 -- 22}, year = {2018}, abstract = {Bereits 2015 wurde in der Zeitschrift „Qualit{\"a}t in der Wissenschaft" (QiW) {\"u}ber das Kooperationsprojekt „Guter Studienstart im Ingenieurbereich", das Orientierungssemester von RWTH und FH Aachen, berichtet. In diesem Artikel legen wir den Schwerpunkt auf die Entwicklung des Projekts in den Jahren 2015 bis 2018 und geben eine R{\"u}ckschau sowie einen Ausblick auf die Entwicklungsperspektiven nach dem offiziellen Projektende.}, language = {de} } @article{KlubertMalechaSparla2018, author = {Klubert, Joachim and Malecha, Hartmut and Sparla, Peter}, title = {Modernisierung der geod{\"a}tischen Messtechnik der Urfttalsperre}, series = {Wasserwirtschaft}, volume = {108}, journal = {Wasserwirtschaft}, number = {10}, publisher = {Springer Vieweg}, address = {Wiesbaden}, issn = {0043-0978}, pages = {14 -- 18}, year = {2018}, language = {de} } @article{KochPoghossianSchoeningetal.2018, author = {Koch, Claudia and Poghossian, Arshak and Sch{\"o}ning, Michael Josef and Wege, Christian}, title = {Penicillin Detection by Tobacco Mosaic Virus-Assisted Colorimetric Biosensors}, series = {Nanotheranostics}, volume = {2}, journal = {Nanotheranostics}, number = {2}, publisher = {Ivyspring}, address = {Sydney}, issn = {2206-7418}, doi = {10.7150/ntno.22114}, pages = {184 -- 196}, year = {2018}, abstract = {The presentation of enzymes on viral scaffolds has beneficial effects such as an increased enzyme loading and a prolonged reusability in comparison to conventional immobilization platforms. Here, we used modified tobacco mosaic virus (TMV) nanorods as enzyme carriers in penicillin G detection for the first time. Penicillinase enzymes were conjugated with streptavidin and coupled to TMV rods by use of a bifunctional biotin-linker. Penicillinase-decorated TMV particles were characterized extensively in halochromic dye-based biosensing. Acidometric analyte detection was performed with bromcresol purple as pH indicator and spectrophotometry. The TMV-assisted sensors exhibited increased enzyme loading and strongly improved reusability, and higher analysis rates compared to layouts without viral adapters. They extended the half-life of the sensors from 4 - 6 days to 5 weeks and thus allowed an at least 8-fold longer use of the sensors. Using a commercial budget-priced penicillinase preparation, a detection limit of 100 µM penicillin was obtained. Initial experiments also indicate that the system may be transferred to label-free detection layouts.}, language = {en} }