@article{OliveiraMolinnusBegingetal.2021, author = {Oliveira, Danilo A. and Molinnus, Denise and Beging, Stefan and Siqueira Jr, Jos{\´e} R. and Sch{\"o}ning, Michael Josef}, title = {Biosensor Based on Self-Assembled Films of Graphene Oxide and Polyaniline Using a Field-Effect Device Platform}, series = {physica status solidi (a) applications and materials science}, volume = {218}, journal = {physica status solidi (a) applications and materials science}, number = {13}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.202000747}, pages = {1 -- 9}, year = {2021}, abstract = {A new functionalization method to modify capacitive electrolyte-insulator-semiconductor (EIS) structures with nanofilms is presented. Layers of polyallylamine hydrochloride (PAH) and graphene oxide (GO) with the compound polyaniline:poly(2-acrylamido-2-methyl-1-propanesulfonic acid) (PANI:PAAMPSA) are deposited onto a p-Si/SiO2 chip using the layer-by-layer technique (LbL). Two different enzymes (urease and penicillinase) are separately immobilized on top of a five-bilayer stack of the PAH:GO/PANI:PAAMPSA-modified EIS chip, forming a biosensor for detection of urea and penicillin, respectively. Electrochemical characterization is performed by constant capacitance (ConCap) measurements, and the film morphology is characterized by atomic force microscopy (AFM) and scanning electron microscopy (SEM). An increase in the average sensitivity of the modified biosensors (EIS-nanofilm-enzyme) of around 15\% is found in relation to sensors, only carrying the enzyme but without the nanofilm (EIS-enzyme). In this sense, the nanofilm acts as a stable bioreceptor onto the EIS chip improving the output signal in terms of sensitivity and stability.}, language = {en} } @masterthesis{Ossenkop2021, type = {Bachelor Thesis}, author = {Ossenkop, Birte}, title = {Prepare to care: Kampagne f{\"u}r mehr Unterst{\"u}tzung und Wertsch{\"a}tzung von Young Carern durch ihr direktes Lebensumfeld}, publisher = {FH Aachen}, address = {Aachen}, school = {Fachhochschule Aachen}, pages = {167 Seiten}, year = {2021}, abstract = {In jeder Schulklasse in Deutschland gibt es laut Statistik einen bis zwei Young Carer. Das sind Kinder und Jugendliche, die ein Familienmitglied pflegen. Doch wegen Unverst{\"a}ndnis und Ausgrenzung seitens ihres sozialen Umfeldes vertrauen sich Young Carer niemandem an. Es mangelt schlichtweg an {\"o}ffentlichem Bewusstsein f{\"u}r das Ph{\"a}nomen. Die Kampagne \#nichtbloßjung soll das {\"a}ndern. Sie zeigt einer jungen Zielgruppe, was es bedeutet, nicht bloß jung, sondern Young Carer zu sein. Dabei regt sie dazu an, ebenfalls \#nichtbloßjung zu bleiben, sondern als „Young Supporter" die Young Carer zu unterst{\"u}tzen. Dazu wird diverse Informationsmaterial sowie ein kostenloses Armband bereitgestellt. Die Armbandtragenden zeigen so, dass sie Young Carer unterst{\"u}tzen und als Ansprechpersonen zur Verf{\"u}gung stehen. So lernen Young Carer, dass sie mit ihrer Situation nicht allein sind und an wen sie sich gegebenenfalls wenden k{\"o}nnen.}, language = {de} } @masterthesis{Paulzen2021, type = {Bachelor Thesis}, author = {Paulzen, Lena}, title = {Nachhaltiges Corporate Packaging Design: Am Beispiel von Naturkosmetik Produkten.}, publisher = {FH Aachen}, address = {Aachen}, school = {Fachhochschule Aachen}, pages = {124 Seiten}, year = {2021}, abstract = {Diese Bachelorarbeit widmet sich dem nachhaltigen Packaging-Design von Kosmetikprodukten. Dies wird am Beispiel eines Naturkosmetik-Unternehmens dargestellt. Die Gestaltung einer Shampoo-Flasche wird in dem vorliegenden Projekt exemplarisch f{\"u}r die thematische und gestalterische Untersuchung genutzt. Zudem wurden mit Tube und Tiegel noch zwei weitere Verpackungsformen erstellt. Das Ziel dieser Arbeit ist es, eine nachhaltige Verpackung zu gestalten. Diese soll den hohen CO2-Ausstoß bei der Herstellung von Verpackungen verringern und dabei dem Anspruch des Marketings gerecht werden. Hierbei wurde ein Logo-Design, ein Farbkonzept, eine einheitliche Formsprache und eine Typografie erarbeitet.}, language = {de} } @article{RichterBraunsteinStaeudleetal.2021, author = {Richter, Charlotte and Braunstein, Bjoern and Staeudle, Benjamin and Attias, Julia and Suess, Alexander and Weber, Tobias and Mileva, Katya N. and Rittweger, Joern and Green, David A. and Albracht, Kirsten}, title = {Contractile behavior of the gastrocnemius medialis muscle during running in simulated hypogravity}, series = {npj Microgravity}, volume = {7}, journal = {npj Microgravity}, number = {Article number: 32}, publisher = {Springer Nature}, address = {New York}, issn = {2373-8065}, doi = {10.1038/s41526-021-00155-7}, pages = {7 Seiten}, year = {2021}, abstract = {Vigorous exercise countermeasures in microgravity can largely attenuate muscular degeneration, albeit the extent of applied loading is key for the extent of muscle wasting. Running on the International Space Station is usually performed with maximum loads of 70\% body weight (0.7 g). However, it has not been investigated how the reduced musculoskeletal loading affects muscle and series elastic element dynamics, and thereby force and power generation. Therefore, this study examined the effects of running on the vertical treadmill facility, a ground-based analog, at simulated 0.7 g on gastrocnemius medialis contractile behavior. The results reveal that fascicle-series elastic element behavior differs between simulated hypogravity and 1 g running. Whilst shorter peak series elastic element lengths at simulated 0.7 g appear to be the result of lower muscular and gravitational forces acting on it, increased fascicle lengths and decreased velocities could not be anticipated, but may inform the development of optimized running training in hypogravity. However, whether the alterations in contractile behavior precipitate musculoskeletal degeneration warrants further study.}, language = {en} } @article{RichterBraunsteinStaeudleetal.2021, author = {Richter, Charlotte and Braunstein, Bj{\"o}rn and St{\"a}udle, Benjamin and Attias, Julia and S{\"u}ss, Alexander and Weber, Tobias and Mileva, Katya N. and Rittweger, J{\"o}rn and Green, David A. and Albracht, Kirsten}, title = {Gastrocnemius medialis contractile behavior during running differs between simulated Lunar and Martian gravities}, series = {Scientific reports}, volume = {11}, journal = {Scientific reports}, number = {Article number: 22555}, publisher = {Springer Nature}, address = {London}, issn = {2045-2322}, doi = {10.1038/s41598-021-00527-9}, pages = {13 Seiten}, year = {2021}, abstract = {The international partnership of space agencies has agreed to proceed forward to the Moon sustainably. Activities on the Lunar surface (0.16 g) will allow crewmembers to advance the exploration skills needed when expanding human presence to Mars (0.38 g). Whilst data from actual hypogravity activities are limited to the Apollo missions, simulation studies have indicated that ground reaction forces, mechanical work, muscle activation, and joint angles decrease with declining gravity level. However, these alterations in locomotion biomechanics do not necessarily scale to the gravity level, the reduction in gastrocnemius medialis activation even appears to level off around 0.2 g, while muscle activation pattern remains similar. Thus, it is difficult to predict whether gastrocnemius medialis contractile behavior during running on Moon will basically be the same as on Mars. Therefore, this study investigated lower limb joint kinematics and gastrocnemius medialis behavior during running at 1 g, simulated Martian gravity, and simulated Lunar gravity on the vertical treadmill facility. The results indicate that hypogravity-induced alterations in joint kinematics and contractile behavior still persist between simulated running on the Moon and Mars. This contrasts with the concept of a ceiling effect and should be carefully considered when evaluating exercise prescriptions and the transferability of locomotion practiced in Lunar gravity to Martian gravity.}, language = {en} } @masterthesis{Schmitz2021, type = {Bachelor Thesis}, author = {Schmitz, Jennifer}, title = {Inklusives Design: Multisensorisches Branding f{\"u}r sehbehinderte, blinde und sehende Menschen}, publisher = {FH Aachen}, address = {Aachen}, school = {Fachhochschule Aachen}, pages = {77 Seiten}, year = {2021}, abstract = {Multisensorisches Branding bezeichnet die Gestaltung f{\"u}r mindestens zwei Sinne. Diese Bachelorarbeit beinhaltet daher ein Konzept, um sehbehinderten Menschen und Blinden das Branding einer Marke im Bereich der Bekleidungsindustrie zug{\"a}nglich zu machen. Durch die gezielte Kombination von Haptik und Optik ist im Rahmen dieser Arbeit eine Bekleidungsmarke entstanden, deren Textilien jegliche Informationen f{\"u}r sehbehinderte und blinde Menschen enthalten, ohne dabei auf eine ansprechende Optik f{\"u}r Sehende zu verzichten. Vor allem durch neu entwickelte Open Source Symbole, die f{\"u}hlbar sind, und einen Barcode wird Betroffenen in Zukunft der Kauf von Bekleidung sowie der Waschvorgang erleichtert.}, language = {de} } @masterthesis{Schulze2021, type = {Bachelor Thesis}, author = {Schulze, Lasse}, title = {SCHRECKLICHES : Eine Comic-Antholologie {\"u}ber allt{\"a}gliche {\"A}ngste}, publisher = {FH Aachen}, address = {Aachen}, school = {Fachhochschule Aachen}, pages = {55 Seiten}, year = {2021}, abstract = {{\"A}ngste und Phobien sind vielseitig. Furcht im Alltag spiegelt sich sowohl in spezifischen Objekten als auch in allgemeinen Situationen wider. F{\"u}r unbetroffene Menschen sind diese Emotionen oft unbegreiflich, irrational und abstrakt. In 15 Bildergeschichten werden verschiedene pers{\"o}nliche {\"A}ngste humoristisch illustriert und in einer gebundenen Comic-Anthologie zusammengef{\"u}hrt. Der {\"u}berzogene, bizarre Zeichenstil demonstriert die empfundene Wahrnehmung bei allt{\"a}glichen {\"A}ngsten auf eine nicht allzu ernst gemeinte Weise. Zeichnerische {\"A}sthetik, von klassischem Comic-Stil bis zum grafischen Horror, und Storytelling stehen hier im Vordergrund. Lesende finden sich selbst in den absurden Geschichten wieder und werden im besten Fall zum Lachen gebracht. Die Bachelorarbeit SCHRECKLICHES versucht das abstrakte Gef{\"u}hl der Angst auf nachvollziehbare Art zeichnerisch und mit einer guten Portion {\"U}bertreibung zu vermitteln.}, language = {de} } @masterthesis{Schwinges2021, type = {Bachelor Thesis}, author = {Schwinges, Katrin}, title = {Der/Die/Das Spielzeug: Gestaltung eines geschlechtsneutralen Spielzeugs}, publisher = {FH Aachen}, address = {Aachen}, school = {Fachhochschule Aachen}, pages = {113 Seiten}, year = {2021}, abstract = {Das Projekt bezieht sich auf das globale Konsumverhalten gegen{\"u}ber Spielwaren unter den Bedingungen des Gender-Marketings im Hinblick auf die nachteiligen Bedingungen f{\"u}r die Entwicklung des Kindes und der Umwelt. Gestaltet wurde ein Baukastensystem, das sich keiner geschlechtsspezifischen Zuweisung bedient, und so verhindert, dass Kinder, die sich im bin{\"a}ren Rollenbild nicht wiederfinden, ausgegrenzt werden. Das Stecksystem ohne Vorgabe einer Anleitung erm{\"o}glicht freie Entfaltung beim Spiel und die F{\"o}rderung der spielerischen und didaktischen Entwicklung eines Kindes. Spielen ist eine Art des Kindes sich und seine Umwelt zu begreifen und sich dazu auszudr{\"u}cken. Es werden nicht nur F{\"a}higkeiten erprobt, sondern auch Verhaltensweisen angeeignet und Identit{\"a}tsmerkmale definiert. Dadurch erh{\"a}lt das Spielzeug eine Vorbildfunktion. Dieser Vorbildfunktion soll das entworfene Produkt gerecht werden.}, language = {de} } @masterthesis{Spomer2021, type = {Bachelor Thesis}, author = {Spomer, Ruth}, title = {Zoologisches Forschungsmuseum Alexander K{\"o}nig : Entwicklung eines neuen Erscheinungsbildes}, publisher = {FH Aachen}, address = {Aachen}, school = {Fachhochschule Aachen}, pages = {139 Seiten}, year = {2021}, abstract = {Artenvielfalt erforschen und erkl{\"a}ren - So lautet der Leitsatz des Bonner Forschungsmuseums. Durch inszenierte Lebensr{\"a}ume sowie beeindruckende sammlungsbasierte Ausstellungen werden komplexe biologische Ph{\"a}nomene erkl{\"a}rt und die Biodiversit{\"a}tsforschung f{\"u}r ein breites Publikum zug{\"a}nglich gemacht. Dabei wird das {\"u}bergeordnete Ziel verfolgt, das Interesse der Allgemeinheit an zoologischer Wissenschaft zu wecken. Das neue Erscheinungsbild schafft Wiedererkennbarkeit und positioniert das Museum als wissenschaftliche Institution. Dabei stellt die Verkn{\"u}pfung des Forschungsaspektes und der Artenvielfalt die Basis der Gestaltung dar und kommuniziert die wesentlichen Inhalte. Zudem sorgt ein medien{\"u}bergreifendes Ordnungssystem f{\"u}r eine bessere {\"U}bersicht und erleichtert den Zugang zu komplexen Inhalten. So erh{\"a}lt das Museum eine spannendere, attraktivere Wirkung nach Außen und eine bessere Orientierung im Inneren.}, language = {de} } @article{Staat2021, author = {Staat, Manfred}, title = {An extension strain type Mohr-Coulomb criterion}, series = {Rock mechanics and rock engineering}, volume = {54}, journal = {Rock mechanics and rock engineering}, number = {12}, publisher = {Springer Nature}, address = {Cham}, issn = {1434-453X}, doi = {10.1007/s00603-021-02608-7}, pages = {6207 -- 6233}, year = {2021}, abstract = {Extension fractures are typical for the deformation under low or no confining pressure. They can be explained by a phenomenological extension strain failure criterion. In the past, a simple empirical criterion for fracture initiation in brittle rock has been developed. In this article, it is shown that the simple extension strain criterion makes unrealistic strength predictions in biaxial compression and tension. To overcome this major limitation, a new extension strain criterion is proposed by adding a weighted principal shear component to the simple criterion. The shear weight is chosen, such that the enriched extension strain criterion represents the same failure surface as the Mohr-Coulomb (MC) criterion. Thus, the MC criterion has been derived as an extension strain criterion predicting extension failure modes, which are unexpected in the classical understanding of the failure of cohesive-frictional materials. In progressive damage of rock, the most likely fracture direction is orthogonal to the maximum extension strain leading to dilatancy. The enriched extension strain criterion is proposed as a threshold surface for crack initiation CI and crack damage CD and as a failure surface at peak stress CP. Different from compressive loading, tensile loading requires only a limited number of critical cracks to cause failure. Therefore, for tensile stresses, the failure criteria must be modified somehow, possibly by a cut-off corresponding to the CI stress. Examples show that the enriched extension strain criterion predicts much lower volumes of damaged rock mass compared to the simple extension strain criterion.}, language = {en} }