@article{StreunBrandenburgLarueetal.2002, author = {Streun, M. and Brandenburg, G. and Larue, H. and Zimmermann, E. and Ziemons, Karl and Halling, H.}, title = {Coincidence detection by digital processing of free-running sampled pulses}, series = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, volume = {487}, journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, number = {3}, isbn = {0168-9002}, pages = {530 -- 534}, year = {2002}, abstract = {Coincident events in two scintillator crystals coupled to photomultipliers (PMT) are detected by processing just the digital data of the recorded pulses. For this purpose the signals from both PMTs are continuously sampled by free-running ADCs at a sampling rate of 40 MHz. For each sampled pulse the starting time is determined by processing the pulse data. Even a fairly simple interpolating algorithm results in a FWHM of about 2 ns.}, language = {en} } @article{StreunBrandenburgLarueetal.2002, author = {Streun, M. and Brandenburg, G. and Larue, H. and Zimmermann, E. and Ziemons, Karl and Halling, H.}, title = {A PET system based on data processing of free-running sampled pulses}, series = {2001 IEEE Nuclear Science Symposium Conference Record, Vol. 2}, journal = {2001 IEEE Nuclear Science Symposium Conference Record, Vol. 2}, issn = {1082-3654}, pages = {693 -- 694}, year = {2002}, abstract = {Within the developments for the Crystal Clear small animal PET project (CLEARPET) a dual head PET system has been established. The basic principle is the early digitization of the detector pulses by free running ADCs. The determination of the γ-energy and also the coincidence detection is performed by data processing of the sampled pulses on the host computer. Therefore a time mark is attached to each pulse identifying the current cycle of the 40 MHz sampling clock. In order to refine the time resolution the pulse starting time is interpolated from the samples of the pulse rise. The detector heads consist of multichannel PMTs with a single LSO scintillator crystal coupled to each channel. For each PMT only one ADC is required. The position of an event is obtained separately from trigger signals generated for each single channel. An FPGA is utilized for pulse buffering, generation of the time mark and for the data transfer to the host via a fast I/O-interface.}, language = {en} } @inproceedings{StaatHeitzer2002, author = {Staat, Manfred and Heitzer, Michael}, title = {The restricted influence of kinematic hardening on shakedown loads}, year = {2002}, abstract = {Structural design analyses are conducted with the aim of verifying the exclusion of ratcheting. To this end it is important to make a clear distinction between the shakedown range and the ratcheting range. In cyclic plasticity more sophisticated hardening models have been suggested in order to model the strain evolution observed in ratcheting experiments. The hardening models used in shakedown analysis are comparatively simple. It is shown that shakedown analysis can make quite stable predictions of admissible load ranges despite the simplicity of the underlying hardening models. A linear and a nonlinear kinematic hardening model of two-surface plasticity are compared in material shakedown analysis. Both give identical or similar shakedown ranges. Structural shakedown analyses show that the loading may have a more pronounced effect than the hardening model.}, subject = {Biomedizinische Technik}, language = {en} } @article{StaatHeitzer2002, author = {Staat, Manfred and Heitzer, M.}, title = {Limit and Shakedown Analysis with Uncertain Data}, series = {Stochastic optimization techniques : numerical methods and technical applications / Marti, K. [ed]}, journal = {Stochastic optimization techniques : numerical methods and technical applications / Marti, K. [ed]}, publisher = {Springer}, address = {Heidelberg}, isbn = {3-540-42889-5}, pages = {241 -- 254}, year = {2002}, language = {en} } @article{Staat2002, author = {Staat, Manfred}, title = {Some Achievements of the European Project LISA for FEM Based Limit and Shakedown Analysis}, series = {Computational mechanics : developments and applications, 2002 : presented at the 2002 ASME Pressure Vessels and Piping Conference, Vancouver, British Columbia, Canada, August 5 - 9. / Badie, N. [ed]}, journal = {Computational mechanics : developments and applications, 2002 : presented at the 2002 ASME Pressure Vessels and Piping Conference, Vancouver, British Columbia, Canada, August 5 - 9. / Badie, N. [ed]}, publisher = {American Society of Mechanical Engineers}, address = {New York}, isbn = {0791846520}, pages = {177 -- 185}, year = {2002}, language = {en} } @article{SponagelBaroudSteffenetal.2002, author = {Sponagel, Stefan and Baroud, G. and Steffen, T. and Wu, J.}, title = {Parameter identification for cement infiltration of osteoporotic bone}, series = {Poromechanics II : Proceedings of the Second Biot Conference on Poromechanics Grenoble, France 26 - 28 August 2002 / ed. by J.-L. Auriault ...}, journal = {Poromechanics II : Proceedings of the Second Biot Conference on Poromechanics Grenoble, France 26 - 28 August 2002 / ed. by J.-L. Auriault ...}, publisher = {Balkema}, address = {Lisse [u.a.]}, isbn = {90-5809-394-8}, pages = {55 -- 58}, year = {2002}, language = {en} } @article{SelmerWillanzheimerHetzel2002, author = {Selmer, Thorsten and Willanzheimer, Angela and Hetzel, Marc}, title = {Propionate CoA-transferase from Clostridium propionicum. Cloning of the gene and identification of glutamate 324 at the active site}, series = {European Journal of Biochemistry. 269 (2002), H. 1}, journal = {European Journal of Biochemistry. 269 (2002), H. 1}, isbn = {0014-2956}, pages = {372 -- 380}, year = {2002}, language = {en} } @article{SelmerNetzPohletal.2002, author = {Selmer, Thorsten and Netz, Daili Jacqueline Aguilar and Pohl, Regula and Beck-Sickinger, Annette G.}, title = {Biochemical characterisation and genetic analysis of aureocin A53, a new, atypical bacteriocin from Staphylococcus aureus / Netz, Daili Jacqueline Aguilar ; Pohl, Regula ; Beck-Sickinger, Annette G. ; Selmer, Thorsten ; Pierik, Antonio J. ; Carmo de Frei}, series = {Journal of Molecular Biology. 319 (2002), H. 3}, journal = {Journal of Molecular Biology. 319 (2002), H. 3}, isbn = {0022-2836}, pages = {745 -- 756}, year = {2002}, language = {en} } @article{SchoeningWangKrauseetal.2002, author = {Sch{\"o}ning, Michael Josef and Wang, Josepf and Krause, Robin and Block, Kirstin and Musameh, Mustafa and Mulchandani, Ashok and Mulchandani, Priti and Chen, Wilfred}, title = {Dual amperometric-potentiometric biosensor detection system for monitoring organophosphorus neurotoxins}, series = {Analyica Chimica Acta. 469 (2002), H. 2}, journal = {Analyica Chimica Acta. 469 (2002), H. 2}, isbn = {0378-4304}, pages = {197 -- 203}, year = {2002}, language = {en} } @article{SchoeningSimonisRugeetal.2002, author = {Sch{\"o}ning, Michael Josef and Simonis, Anette and Ruge, Christian and Ecken, Holger and M{\"u}ller-Veggian, Mattea and L{\"u}th, Hans}, title = {A (bio-)chemical Field-effect Sensor with Macroporous Si as Substrate Material and a SiO₂ / LPCVD-Si₃N₄ Double Layer as pH Transducer}, series = {Sensors. 2 (2002), H. 1}, journal = {Sensors. 2 (2002), H. 1}, isbn = {1424-8220}, doi = {10.3390/s20100011}, pages = {11 -- 22}, year = {2002}, abstract = {Macroporous silicon has been etched from n-type Si, using a vertical etching cell where no rear side contact on the silicon wafer is necessary. The resulting macropores have been characterised by means of Scanning Electron Microscopy (SEM). After etching, SiO₂ was thermally grown on the top of the porous silicon as an insulating layer and Si₃N₄ was deposited by means of Low Pressure Chemical Vapour Deposition (LPCVD) as transducer material to fabricate a capacitive pH sensor. In order to prepare porous biosensors, the enzyme penicillinase has been additionally immobilised inside the porous structure. Electrochemical measurements of the pH sensor and the biosensor with an Electrolyte/Insulator/Semiconductor (EIS) structure have been performed in the Capacitance/Voltage (C/V) and Constant capacitance (ConCap) mode.}, language = {en} }