@book{DavidBenkner2013, author = {David, Klaus and Benkner, Thorsten}, title = {Digitale Mobilfunksysteme}, number = {Repr. 1996}, publisher = {Vieweg \& Teubner}, address = {Wiesbaden}, isbn = {978-3-322-92768-2}, pages = {XIII, 458 S.}, year = {2013}, language = {de} } @incollection{DautzenbergGrossRenz1996, author = {Dautzenberg, H. and Groß, Rolf Fritz and Renz, Ulrich}, title = {Meßtechnik auf dem Pr{\"u}fstand: Forschung zur Heißgasfiltration}, series = {Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 1996}, booktitle = {Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 1996}, editor = {Jamal, Rahman}, publisher = {National Instruments Germany}, address = {M{\"u}nchen}, pages = {202 -- 208}, year = {1996}, abstract = {Im Rahmen von Forschungsvorhaben des BMBF und verschiedener Industriepartner betreibt der Lehrstuhl f{\"u}r W{\"a}rme{\"u}bertragung und Klimatechnik der RWTH Aachen Pilotanlagen und Pr{\"u}fst{\"a}nde f{\"u}r Untersuchungen auf dem Gebiet der Heißgasfiltration mit keramischen Filterelementen. Als wesentlicher Garant f{\"u}r den Erfolg der Forschungsarbeit muß die auf das jeweilige Projekt genau abgestimmte Meß- und Regelungstechnik angesehen werden. Hierbei z{\"a}hlt neben der Auswahl geeigneter Hardwarekomponenten auch die Softwareentwicklung unter einer leistungsstarken und zuverl{\"a}ssigen Programmierumgebung. Anhand des Aufbaus dreier Versuchsanlagen im Technikumsmaßstab soll das Anforderungsprofil an die Meßtechnik bis hin zur Umsetzung innerhalb der Anlage skizziert werden. Der Heißgasfiltrationspr{\"u}fstand im Heizkraftwerk der RWTH Aachen dient der Beobachtung des Reinigungsverhaltens keramischer Filterelemente bei der Heißgasentstaubung im Temperaturbereich bis 850 Grad C. Wesentlich f{\"u}r die Meßwerterfassung ist hierbei die Kopplung eines Orion-Datenloggers der Firma Schlumberger mit LabView 4.0. Im Hochtemperaturofen des Lehrstuhls werden instation{\"a}re Druckmessungen an einer keramischen Filterkerze w{\"a}hrend eines Abreinigungsimpulses bei 950 Grad C mit hoher Samplingrate durchgef{\"u}hrt. Hierbei {\"u}bernimmt eine durch LabView 4.0 angesteuerte E-Series Karte der Firma National Instruments die Signalaufnahme. Die katalytische Schadstoffreduktion und Entstaubung heißer Rauchgase bei 900 Grad C sind Ziele der Untersuchungen in einer erstellten Versuchsanlage mit einem Quarzglasreaktor. Die Signalerfassung und -konditionierung erfolgt {\"u}ber SCXI in Verbindung mit LabView 4.0, die Steuerung der Anlage {\"u}bernehmen zwei Multifunktionskarten (National Instruments).}, language = {de} } @misc{DauerHojdisMuelleretal.2019, author = {Dauer, David-Raphael and Hojdis, Nils and M{\"u}ller, Norbert and Recker, Carla and Schax, Fabian and Sch{\"o}ffel, Julia and Tarantola, Gesa and Weber, Christine}, title = {Schwefelvernetzbare Kautschukmischung, Vulkanisat der Kautschukmischung und Fahrzeugreifen}, year = {2019}, abstract = {Die Erfindung betrifft eine schwefelvernetzbare Kautschukmischung, deren Vulkanisat und einen Fahrzeugreifen. Die schwefelvernetzbare Kautschukmischung enth{\"a}lt wenigstens die folgenden Bestandteile: - wenigstens einen Dienkautschuk; und - 10 bis 300 phr wenigstens einer Kiesels{\"a}ure; und - 1 bis 30 phf wenigstens eines Silans A mit der allgemeinen Summenformel A-I) A-I)(R1)oSi-R2-(S-R3)q-S-X; und - 0,5 bis 30 phf wenigstens eines Silans B mit der allgemeinen Summenformel B-I) B-I) (R1)oSi-R2-(S-R3)u-S-R2-Si(R1)o wobei q =1, 2 oder 3 ist; und u = 1, 2 oder 3 ist; und X ein Wasserstoffatom oder eine -C(=O)-R8 Gruppe ist wobei R8 ausgew{\"a}hlt ist aus Wasserstoff, C1-C20 Alkylgruppen, vorzugsweise C1-C17, C6-C20- Arylgruppen, vorzugsweise Phenyl, C2-C20-Alkenylgruppen und C7-C20-Aralkylgruppen.}, language = {de} } @misc{DauerHojdisMuelleretal.2019, author = {Dauer, David-Raphael and Hojdis, Nils and M{\"u}ller, Norbert and Recker, Carla and Schax, Fabian and Sch{\"o}ffel, Julia and Tarantola, Gesa and Weber, Christine}, title = {Schwefelvernetzbare Kautschukmischung, Vulkanisat der Kautschukmischung und Fahrzeugreifen}, year = {2019}, abstract = {Die Erfindung betrifft eine schwefelvernetzbare Kautschukmischung, deren Vulkanisat und einen Fahrzeugreifen.Die schwefelvernetzbare Kautschukmischung enth{\"a}lt wenigstens die folgenden Bestandteile:- wenigstens einen Dienkautschuk; und- 10 bis 300 phr wenigstens einer Kiesels{\"a}ure ; und- 1 bis 30 phf wenigstens eines Silans A mit der allgemeinen Summenformel A-I)und- 0,5 bis 30 phf wenigstens eines Silans B mit der allgemeinen Summenformel B-I)wobei u gleich 0, 1, 2 oder 3 und v gleich 0 oder 1 ist.}, language = {de} } @article{DashevskyLanzlKotliar2011, author = {Dashevsky, Alexey V. and Lanzl, Ines M. and Kotliar, Konstantin}, title = {Non-penetrating intracanalicular partial trabeculectomy via the ostia of Schlemm's canal}, series = {Graefe's Archive for Clinical and Experimental Ophthalmology}, volume = {249}, journal = {Graefe's Archive for Clinical and Experimental Ophthalmology}, number = {4}, publisher = {Springer}, address = {Berlin}, issn = {0721-832x}, pages = {565 -- 573}, year = {2011}, language = {en} } @article{DarmoSchaefferFoersteretal.2000, author = {Darmo, J. and Sch{\"a}ffer, F. and F{\"o}rster, Arnold and Kordos, P.}, title = {Beryllium doped low-temperature-grown MBE GaAs: material for photomixing in the THz frequency range}, series = {ASDAM 2000 : conference proceedings / edited by Jozef Osvald ... [et al.]}, journal = {ASDAM 2000 : conference proceedings / edited by Jozef Osvald ... [et al.]}, publisher = {IEEE}, address = {Piscataway, NJ}, isbn = {0780359399}, pages = {147 -- 150}, year = {2000}, language = {en} } @article{DantismTakenagaWagneretal.2017, author = {Dantism, Shahriar and Takenaga, Shoko and Wagner, Torsten and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Differential imaging of the metabolism of bacteria and eukaryotic cells based on light-addressable potentiometric sensors}, series = {Electrochimica Acta}, volume = {246}, journal = {Electrochimica Acta}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0013-4686}, doi = {10.1016/j.electacta.2017.05.196}, pages = {234 -- 241}, year = {2017}, abstract = {A light-addressable potentiometric sensor (LAPS) is a field-effect-based potentiometric sensor with an electrolyte/insulator/semiconductor (EIS) structure, which is able to monitor analyte concentrations of (bio-)chemical species in aqueous solutions in a spatially resolved way. Therefore, it is also an appropriate tool to record 2D-chemical images of concentration variations on the sensor surface. In the present work, two differential, LAPS-based measurement principles are introduced to determine the metabolic activity of Escherichia coli (E. coli) K12 and Chinese hamster ovary (CHO) cells as test microorganisms. Hereby, we focus on i) the determination of the extracellular acidification rate (ΔpH/min) after adding glucose solutions to the cell suspensions; and ii) recording the amplitude increase of the photocurrent (Iph) related to the produced acids from E. coli K12 bacteria and CHO cells on the sensor surface by 2D-chemical imaging. For this purpose, 3D-printed multi-chamber structures were developed and mounted on the planar sensor-chip surface to define four independent compartments, enabling differential measurements with varying cell concentrations. The differential concept allows eliminating unwanted drift effects and, with the four-chamber structures, measurements on the different cell concentrations were performed simultaneously, thus reducing also the overall measuring time.}, language = {en} } @article{DantismTakenagaWagneretal.2016, author = {Dantism, Shahriar and Takenaga, Shoko and Wagner, Patrick and Wagner, Torsten and Sch{\"o}ning, Michael Josef}, title = {Determination of the extracellular acidification of Escherichia coli K12 with a multi-​chamber-​based LAPS system}, series = {Physica status solidi (a)}, volume = {213}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6300}, doi = {10.1002/pssa.201533043}, pages = {1479 -- 1485}, year = {2016}, abstract = {On-line monitoring of the metabolic activity of microorganisms involved in intermediate stages of biogas production plays an important role to avoid undesirable "down times" during the biogas production. In order to control this process, an on-chip differential measuring system based on the light-addressable potentiometric sensor (LAPS) principle combined with a 3D-printed multi-chamber structure has been realized. As a test microorganism, Escherichia coli K12 (E. coli K12) were used for cell-based measurements. Multi-chamber structures were developed to determine the metabolic activity of E. coli K12 in suspension for a different number of cells, responding to the addition of a constant or variable amount of glucose concentrations, enabling differential and simultaneous measurements.}, language = {en} } @article{DantismRoehlenWagneretal.2018, author = {Dantism, Shahriar and R{\"o}hlen, Desiree and Wagner, Torsten and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Optimization of Cell-Based Multi-Chamber LAPS Measurements Utilizing FPGA-Controlled Laser-Diode Modules}, series = {physica status solidi a : applications and materials sciences}, volume = {215}, journal = {physica status solidi a : applications and materials sciences}, number = {15}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201800058}, pages = {Article number 1800058}, year = {2018}, abstract = {A light-addressable potentiometric sensor (LAPS) is a field-effect-based potentiometric device, which detects concentration changes of an analyte solution on the sensor surface in a spatially resolved way. It uses a light source to generate electron-hole pairs inside the semiconductor, which are separated in the depletion region due to an applied bias voltage across the sensor structure and hence, a surface-potential-dependent photocurrent can be read out. However, depending on the beam angle of the light source, scattering effects can occur, which influence the recorded signal in LAPS-based differential measurements. To solve this problem, a novel illumination unit based on a field programmable gate array (FPGA) consisting of 16 small-sized tunable infrared laser-diode modules (LDMs) is developed. Due to the improved focus of the LDMs with a beam angle of only 2 mrad, undesirable scattering effects are minimized. Escherichia coli (E. coli) K12 bacteria are used as a test microorganism to study the extracellular acidification on the sensor surface. Furthermore, a salt bridge chamber is built up and integrated with the LAPS system enabling multi-chamber differential measurements with a single Ag/AgCl reference electrode.}, language = {en} } @article{DantismRoehlenWagneretal.2019, author = {Dantism, Shahriar and R{\"o}hlen, Desiree and Wagner, Torsten and Wagner, P. and Sch{\"o}ning, Michael Josef}, title = {A LAPS-based differential sensor for parallelized metabolism monitoring of various bacteria}, series = {Sensors}, volume = {19}, journal = {Sensors}, number = {21}, publisher = {MDPI}, address = {Basel}, issn = {1424-8220}, doi = {10.3390/s19214692}, pages = {Artikel 4692}, year = {2019}, abstract = {Monitoring the cellular metabolism of bacteria in (bio)fermentation processes is crucial to control and steer them, and to prevent undesired disturbances linked to metabolically inactive microorganisms. In this context, cell-based biosensors can play an important role to improve the quality and increase the yield of such processes. This work describes the simultaneous analysis of the metabolic behavior of three different types of bacteria by means of a differential light-addressable potentiometric sensor (LAPS) set-up. The study includes Lactobacillus brevis, Corynebacterium glutamicum, and Escherichia coli, which are often applied in fermentation processes in bioreactors. Differential measurements were carried out to compensate undesirable influences such as sensor signal drift, and pH value variation during the measurements. Furthermore, calibration curves of the cellular metabolism were established as a function of the glucose concentration or cell number variation with all three model microorganisms. In this context, simultaneous (bio)sensing with the multi-organism LAPS-based set-up can open new possibilities for a cost-effective, rapid detection of the extracellular acidification of bacteria on a single sensor chip. It can be applied to evaluate the metabolic response of bacteria populations in a (bio)fermentation process, for instance, in the biogas fermentation process.}, language = {en} }