@article{AlmajhdiSengerAmeretal.2014, author = {Almajhdi, Fahad N. and Senger, Tilo and Amer, Haitham M. and Gissmann, Lutz and {\"O}hlschl{\"a}ger, Peter}, title = {Design of a highly effective therapeutic HPV16 E6/E7-specific DNA vaccine: optimization by different ways of sequence rearrangements (Shuffling)}, series = {PLOS one}, volume = {11}, journal = {PLOS one}, number = {9}, publisher = {PLOS}, address = {San Francisco}, issn = {1932-6203}, doi = {10.1371/journal.pone.0113461}, pages = {e113461}, year = {2014}, abstract = {Persistent infection with the high-risk Human Papillomavirus type 16 (HPV 16) is the causative event for the development of cervical cancer and other malignant tumors of the anogenital tract and of the head and neck. Despite many attempts to develop therapeutic vaccines no candidate has entered late clinical trials. An interesting approach is a DNA based vaccine encompassing the nucleotide sequence of the E6 and E7 viral oncoproteins. Because both proteins are consistently expressed in HPV infected cells they represent excellent targets for immune therapy. Here we report the development of 8 DNA vaccine candidates consisting of differently rearranged HPV-16 E6 and E7 sequences within one molecule providing all naturally occurring epitopes but supposedly lacking transforming activity. The HPV sequences were fused to the J-domain and the SV40 enhancer in order to increase immune responses. We demonstrate that one out of the 8 vaccine candidates induces very strong cellular E6- and E7- specific cellular immune responses in mice and, as shown in regression experiments, efficiently controls growth of HPV 16 positive syngeneic tumors. This data demonstrates the potential of this vaccine candidate to control persistent HPV 16 infection that may lead to malignant disease. It also suggests that different sequence rearrangements influence the immunogenecity by an as yet unknown mechanism.}, language = {en} } @article{HillgaertnerPeier2006, author = {Hillg{\"a}rtner, Michael and Peier, Dirk}, title = {Design of a Measurement Setup for the Impedance of Low-Resistance Plate-Conductors in the RF-Range}, series = {Proceedings of the 10th International Conference on Optimization of Electrical and Electronic Equipment, OPTIM '06, Bra\&\#351;ov, May 18 - 20, 2006 / ed. by The Transilvania University of Bra\&\#351;ov, Faculty of Electrical Engineering and Computer Science. [Ed. Mihai Cernat .\&\#804;] . - Vol. 1: Keynote addresses, electrotechnics}, journal = {Proceedings of the 10th International Conference on Optimization of Electrical and Electronic Equipment, OPTIM '06, Bra\&\#351;ov, May 18 - 20, 2006 / ed. by The Transilvania University of Bra\&\#351;ov, Faculty of Electrical Engineering and Computer Science. [Ed. Mihai Cernat .\&\#804;] . - Vol. 1: Keynote addresses, electrotechnics}, address = {Bra\&\#351;ov}, isbn = {978-973-635703-9}, pages = {59 -- 64}, year = {2006}, language = {en} } @article{FrankoDuKallweitetal.2020, author = {Franko, Josef and Du, Shengzhi and Kallweit, Stephan and Duelberg, Enno Sebastian and Engemann, Heiko}, title = {Design of a Multi-Robot System for Wind Turbine Maintenance}, series = {Energies}, volume = {13}, journal = {Energies}, number = {10}, publisher = {MDPI}, address = {Basel}, issn = {1996-1073}, doi = {10.3390/en13102552}, pages = {Article 2552}, year = {2020}, abstract = {The maintenance of wind turbines is of growing importance considering the transition to renewable energy. This paper presents a multi-robot-approach for automated wind turbine maintenance including a novel climbing robot. Currently, wind turbine maintenance remains a manual task, which is monotonous, dangerous, and also physically demanding due to the large scale of wind turbines. Technical climbers are required to work at significant heights, even in bad weather conditions. Furthermore, a skilled labor force with sufficient knowledge in repairing fiber composite material is rare. Autonomous mobile systems enable the digitization of the maintenance process. They can be designed for weather-independent operations. This work contributes to the development and experimental validation of a maintenance system consisting of multiple robotic platforms for a variety of tasks, such as wind turbine tower and rotor blade service. In this work, multicopters with vision and LiDAR sensors for global inspection are used to guide slower climbing robots. Light-weight magnetic climbers with surface contact were used to analyze structure parts with non-destructive inspection methods and to locally repair smaller defects. Localization was enabled by adapting odometry for conical-shaped surfaces considering additional navigation sensors. Magnets were suitable for steel towers to clamp onto the surface. A friction-based climbing ring robot (SMART— Scanning, Monitoring, Analyzing, Repair and Transportation) completed the set-up for higher payload. The maintenance period could be extended by using weather-proofed maintenance robots. The multi-robot-system was running the Robot Operating System (ROS). Additionally, first steps towards machine learning would enable maintenance staff to use pattern classification for fault diagnosis in order to operate safely from the ground in the future.}, language = {en} } @article{KalbeHoeckerBerndt1989, author = {Kalbe, Jochen and H{\"o}cker, Hartwig and Berndt, Heinz}, title = {Design of enzyme reactors as chromatographic columns for racemic resolution of amino acid esters}, series = {Chromatographia}, volume = {28}, journal = {Chromatographia}, number = {3-4}, isbn = {0009-5893}, doi = {10.1007/BF02319646}, pages = {193 -- 196}, year = {1989}, language = {en} } @article{HillgaertnerStoniesPeieretal.2005, author = {Hillg{\"a}rtner, Michael and Stonies, R. and Peier, D. and Voges, E.}, title = {Design of Low Cost Antennas for Reverberation Chambers}, series = {Proceedings of the 16th International Zurich Symposium on Electromagnetic Compatibility : [EMC Week 2005, Zurich, Switzerland, February 13 - 18 ; technical exhibition on EMC and RF/microwave Measurements and Instrumentation (February 15 - 17)] / [Laboratory for Electromagnetic Fields and Microwave Electronics, Swiss Federal Institute of Technology Zurich]}, journal = {Proceedings of the 16th International Zurich Symposium on Electromagnetic Compatibility : [EMC Week 2005, Zurich, Switzerland, February 13 - 18 ; technical exhibition on EMC and RF/microwave Measurements and Instrumentation (February 15 - 17)] / [Laboratory for Electromagnetic Fields and Microwave Electronics, Swiss Federal Institute of Technology Zurich]}, publisher = {ETH-Zentrum-IFH}, address = {Z{\"u}rich}, isbn = {3-9521199-9-7}, pages = {1 CD-ROM. ; 12 cm}, year = {2005}, language = {en} } @article{KuertenMottaghyZiegler2015, author = {K{\"u}rten, Sylvia and Mottaghy, Darius and Ziegler, Martin}, title = {Design of plane energy geostructures based on laboratory tests and numerical modelling}, series = {Energy and Buildings}, volume = {107}, journal = {Energy and Buildings}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0378-7788}, doi = {10.1016/j.enbuild.2015.08.039}, pages = {434 -- 444}, year = {2015}, language = {en} } @article{HeinrichsPietrzykZiemons2003, author = {Heinrichs, U. and Pietrzyk, U. and Ziemons, Karl}, title = {Design optimization of the PMT-ClearPET prototypes based on simulation studies with GEANT3}, series = {2002 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, journal = {2002 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, issn = {1082-3654}, pages = {682 -- 686}, year = {2003}, abstract = {Within the Crystal Clear Collaboration four centres are developing 2nd generation high performance small animal PET scanners for different kinds of animals and medical applications. The first prototypes are PMT-based systems including depth of interaction (DOI) detection by using a phoswich layer of LSO and LuYAP. The aim of these simulation studies is to optimize sensitivity and spatial resolution of given designs, which vary in FOVs caused by different detector configurations (ring/octagon) and sizes. For this purpose the simulation tool GEANT3 (CERN) was used. The simulations have shown that all PMT designs with one-to-one coupling of crystals have a very nonlinear axial sensitivity profile. By shifting every other PMT 1/4 of a PMT length in axial direction the sampling of the FOVs became more homogeneous. At an energy threshold of 350keV the regression coefficient increases from 0.818 for the non-shifted to 0.993 for the shifted design. Simulations of a point source centred in the FOV (threshold: 350keV) resulted in sensitivities of 4.2\% for a 4×20PMT (LSO/LuYAP a 10mm) and 3.8\% for a 4×16PMT (LSO/LuYAP a 8mm) ring design. The 3D-MLEM reconstruction of a point source shows the enormous improvement of resolution using a crystal double layer with DOI (3.1mm at 40mm from CFOV) instead of a 20mm single layer (11.9mm).}, language = {en} } @article{HeinrichsPietrzykZiemons2003, author = {Heinrichs, U. and Pietrzyk, U. and Ziemons, Karl}, title = {Design optimization of the PMT-ClearPET prototypes based on simulation studies with GEANT3}, series = {IEEE Transactions on Nuclear Science}, volume = {50}, journal = {IEEE Transactions on Nuclear Science}, number = {5}, isbn = {0018-9499}, pages = {1428 -- 1432}, year = {2003}, abstract = {Within the Crystal Clear Collaboration (CCC), four centers are developing second generation high performance small animal positron emission tomography (PET) scanners for different kinds of animals and medical applications. The first prototypes are photomultiplier tube (PMT)-based systems including depth of interaction (DOI) detection by using a phoswich layer of lutetium oxyorthosilicate (LSO) and lutetium yttrium aluminum perovskite (LuYAP). The aim of these simulation studies is to optimize sensitivity and spatial resolution of given designs, which vary in fields of view (FOVs) caused by different detector configurations (ring/octagon) and sizes. For this purpose the simulation tool GEANT3 (CERN, Geneva, Switzerland) was used.}, language = {en} } @article{NiemuellerFerreinBecketal.2010, author = {Niem{\"u}ller, Tim and Ferrein, Alexander and Beck, Daniel and Lakemeyer, Gerhard}, title = {Design Principles of the Component-Based Robot Software Framework Fawkes}, series = {Simulation, Modeling, and Programming for Autonomous Robots}, journal = {Simulation, Modeling, and Programming for Autonomous Robots}, pages = {300 -- 311}, year = {2010}, language = {en} } @article{ChoiFelderFelderetal.2020, author = {Choi, Chang-Hoon and Felder, Tim and Felder, J{\"o}rg and Tellmann, Lutz and Hong, Suk-Min and Wegener, Hans-Peter and Shah, N Jon and Ziemons, Karl}, title = {Design, evaluation and comparison of endorectal coils for hybrid MR-PET imaging of the prostate}, series = {Physics in Medicine \& Biology}, volume = {65}, journal = {Physics in Medicine \& Biology}, number = {11}, publisher = {IOP}, address = {Bristol}, issn = {0031-9155}, doi = {10.1088/1361-6560/ab87f8}, year = {2020}, abstract = {Prostate cancer is one of the most common cancers among men and its early detection is critical for its successful treatment. The use of multimodal imaging, such as MR-PET, is most advantageous as it is able to provide detailed information about the prostate. However, as the human prostate is flexible and can move into different positions under external conditions, it is important to localise the focused region-of-interest using both MRI and PET under identical circumstances. In this work, we designed five commonly used linear and quadrature radiofrequency surface coils suitable for hybrid MR-PET use in endorectal applications. Due to the endorectal design and the shielded PET insert, the outer face of the coils investigated was curved and the region to be imaged was outside the volume of the coil. The tilting angles of the coils were varied with respect to the main magnetic field direction. This was done to approximate the various positions from which the prostate could be imaged. The transmit efficiencies and safety excitation efficiencies from simulations, together with the signal-to-noise ratios from the MR images were calculated and analysed. Overall, it was found that the overlapped loops driven in quadrature were superior to the other types of coils we tested. In order to determine the effect of the different coil designs on PET, transmission scans were carried out, and it was observed that the differences between attenuation maps with and without the coils were negligible. The findings of this work can provide useful guidance for the integration of such coil designs into MR-PET hybrid systems in the future.}, language = {en} }