@inproceedings{HeringUlberTippkoetter2016, author = {Hering, T. and Ulber, Roland and Tippk{\"o}tter, Nils}, title = {Development of a screening system for antimicrobial surfaces}, series = {New frontiers of biotech-processes (Himmelfahrtstagung) : 02-04 May 2016, Rhein-Mosel-Halle, Koblenz/Germany}, booktitle = {New frontiers of biotech-processes (Himmelfahrtstagung) : 02-04 May 2016, Rhein-Mosel-Halle, Koblenz/Germany}, publisher = {DECHEMA}, address = {Frankfurt am Main}, pages = {129}, year = {2016}, language = {en} } @inproceedings{HoffschmidtSchwarzerSpaeteetal.2006, author = {Hoffschmidt, Bernhard and Schwarzer, Klemens and Sp{\"a}te, Frank and K{\"o}tter, Jens and Ebert, Miriam and Sierck, Olaf}, title = {Development of a small modular parabolic trough collector}, series = {13th International Symposium Concentrated Solar Power and Chemical Energy Technologies : SolarPaces : June 20 - 23, 2006, Seville, Spain}, booktitle = {13th International Symposium Concentrated Solar Power and Chemical Energy Technologies : SolarPaces : June 20 - 23, 2006, Seville, Spain}, publisher = {SolarPaces}, address = {[o.O.]}, organization = {International Symposium on Concentrating Solar Power and Chemical Energy Systems <13, 2006, Sevilla>}, isbn = {8478345191}, pages = {1 CD-ROM}, year = {2006}, language = {en} } @inproceedings{NursinskiStolbergGangatharanCzarnecki2016, author = {Nursinski-Stolberg, Andr{\´e} and Gangatharan, Kiritharan and Czarnecki, Christian}, title = {Development of a subject-oriented reference process model for the telecommunications industry}, series = {GI Edition Proceedings Band 259 INFORMATIK 2016}, booktitle = {GI Edition Proceedings Band 259 INFORMATIK 2016}, editor = {Mayr, Heinrich C. and Pinzger, Martin}, publisher = {Gesellschaft f{\"u}r Informatik e.V.}, address = {Bonn}, isbn = {9783885796534}, issn = {1617-5468}, pages = {699 -- 712}, year = {2016}, abstract = {Generally the usage of reference models can be structured top-down or bottom-up. The practical need of agile change and flexible organizational implementation requires a consistent mapping to an operational level. In this context, well-established reference process models are typically structured top-down. The subject-oriented Business Process Management (sBPM) offers a modeling concept that is structured bottom-up and concentrates on the process actors on an operational level. This paper applies sBPM to the enhanced Telecom Operations Map (eTOM), a well-accepted reference process model in the telecommunications industry. The resulting design artifact is a concrete example for a combination of a bottom-up and top-down developed reference model. The results are evaluated and confirmed in practical context through the involvement of the industry body TMForum.}, language = {en} } @article{WertIkenSchoeningetal.2021, author = {Wert, Stefan and Iken, Heiko and Sch{\"o}ning, Michael Josef and Matysik, Frank-Michael}, title = {Development of a temperature-pulse enhanced electrochemical glucose biosensor and characterization of its stability via scanning electrochemical microscopy}, series = {Electroanalysis}, journal = {Electroanalysis}, number = {Early View}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1521-4109}, doi = {10.1002/elan.202100089}, year = {2021}, abstract = {Glucose oxidase (GOx) is an enzyme frequently used in glucose biosensors. As increased temperatures can enhance the performance of electrochemical sensors, we investigated the impact of temperature pulses on GOx that was drop-coated on flattened Pt microwires. The wires were heated by an alternating current. The sensitivity towards glucose and the temperature stability of GOx was investigated by amperometry. An up to 22-fold increase of sensitivity was observed. Spatially resolved enzyme activity changes were investigated via scanning electrochemical microscopy. The application of short (<100 ms) heat pulses was associated with less thermal inactivation of the immobilized GOx than long-term heating.}, language = {en} } @article{HailerWeberNevelingetal.2020, author = {Hailer, Benjamin and Weber, Tobias and Neveling, Sebastian and Dera, Samuel and Arent, Jan-Christoph and Middendorf, Peter}, title = {Development of a test device to determine the frictional behavior between honeycomb and prepreg layers under realistic manufacturing conditions}, series = {Journal of Sandwich Structures \& Materials}, journal = {Journal of Sandwich Structures \& Materials}, number = {Volume 23, Issue 7}, publisher = {Sage}, address = {London}, issn = {1530-7972}, doi = {10.1177/1099636220923986}, pages = {3017 -- 3043}, year = {2020}, abstract = {In the friction tests between honeycomb with film adhesive and prepreg, the relative displacement occurs between the film adhesive and the prepreg. The film adhesive does not shift relative to the honeycomb. This is consistent with the core crush behavior where the honeycomb moves together with the film adhesive, as can be seen in Figure 2(a). The pull-through forces of the friction measurements between honeycomb and prepreg at 1 mm deformation are plotted in Figure 17(a). While the friction at 100°C is similar to the friction at 120°C, it decreases significantly at 130°C and exhibits a minimum at 140°C. At 150°C, the friction rises again slightly and then sharply at 160°C. Since the viscosity of the M18/1 prepreg resin drops significantly before it cures [23], the minimum friction at 140°C could result from a minimum viscosity of the mixture of prepreg resin and film adhesive before the bond subsequently cures. Figure 17(b) shows the mean value curve of the friction measurements at 140°C. The error bars, which represent the standard deviation, reveal the good repeatability of the tests. The force curve is approximately horizontal between 1 mm and 2 mm. The friction then slightly rises. As with interlaminar friction measurements, this could be due to the fact that resin is removed by friction and the proportion of boundary lubrication increases. Figure 18 shows the surfaces after the friction measurement. The honeycomb cell walls are clearly visible in the film adhesive. There are areas where the film adhesive is completely removed and the carrier material of the film adhesive becomes visible. In addition, the viscosity of the resin changes as the curing progresses during the friction test. This can also affect the force-displacement curve.}, language = {en} } @article{SpelthahnKirsanovLeginetal.2012, author = {Spelthahn, Heiko and Kirsanov, Dmitry and Legin, Andrey and Osterrath, Thomas and Schubert, J{\"u}rgen and Zander, Willi and Sch{\"o}ning, Michael Josef}, title = {Development of a thin-film sensor array for analytical monitoring of heavy metals in aqueous solutions}, series = {Physica Status Solidi (a)}, volume = {209}, journal = {Physica Status Solidi (a)}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, isbn = {1862-6319}, doi = {10.1002/pssa.201100733}, pages = {885 -- 891}, year = {2012}, abstract = {In industrial processes there is a variety of heavy metals (e.g., copper, zinc, cadmium, and lead) in use for wires, coatings, paints, alloys, batteries, etc. Since the application of these transition metals for industry is inevitable, it is a vital task to develop proper analytical techniques for their monitoring at low activity levels, especially because most of these elements are acutely toxic for biological organisms. The determination of ions in solution by means of a simple and inexpensive sensor array is, therefore, a promising task. In this work, a sensor array with heavy metal-sensitive chalcogenide glass membranes for the simultaneous detection of the four ions Ag⁺, Cu2⁺, Cd2⁺, and Pb2⁺ in solution is realized. The results of the physical characterization by means of microscopy, profilometry, Rutherford backscattering spectroscopy (RBS), and scanning electron microscopy (SEM) as well as the electrochemical characterization by means of potentiometric measurements are presented. Additionally, the possibility to expand the sensor array by polymeric sensor membranes is discussed.}, language = {en} } @inproceedings{HunkerJungGossmannetal.2019, author = {Hunker, Jan and Jung, Alexander and Goßmann, Matthias and Linder, Peter and Staat, Manfred}, title = {Development of a tool to analyze the conduction speed in microelectrode array measurements of cardiac tissue}, series = {3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen}, booktitle = {3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen}, editor = {Staat, Manfred and Erni, Daniel}, publisher = {Universit{\"a}t Duisburg-Essen}, address = {Duisburg}, organization = {MedTech Symposium}, isbn = {978-3-940402-22-6}, doi = {10.17185/duepublico/48750}, pages = {7 -- 8}, year = {2019}, abstract = {The discovery of human induced pluripotent stem cells reprogrammed from somatic cells [1] and their ability to differentiate into cardiomyocytes (hiPSC-CMs) has provided a robust platform for drug screening [2]. Drug screenings are essential in the development of new components, particularly for evaluating the potential of drugs to induce life-threatening pro-arrhythmias. Between 1988 and 2009, 14 drugs have been removed from the market for this reason [3]. The microelectrode array (MEA) technique is a robust tool for drug screening as it detects the field potentials (FPs) for the entire cell culture. Furthermore, the propagation of the field potential can be examined on an electrode basis. To analyze MEA measurements in detail, we have developed an open-source tool.}, language = {en} } @article{RoehlenPilasSchoeningetal.2017, author = {R{\"o}hlen, Desiree and Pilas, Johanna and Sch{\"o}ning, Michael Josef and Selmer, Thorsten}, title = {Development of an amperometric biosensor platform for the combined determination of l-Malic, Fumaric, and l-Aspartic acid}, series = {Applied Biochemistry and Biotechnology}, volume = {183}, journal = {Applied Biochemistry and Biotechnology}, publisher = {Springer}, address = {Berlin}, issn = {1559-0291}, doi = {10.1007/s12010-017-2578-1}, pages = {566 -- 581}, year = {2017}, abstract = {Three amperometric biosensors have been developed for the detection of L-malic acid, fumaric acid, and L -aspartic acid, all based on the combination of a malate-specific dehydrogenase (MDH, EC 1.1.1.37) and diaphorase (DIA, EC 1.8.1.4). The stepwise expansion of the malate platform with the enzymes fumarate hydratase (FH, EC 4.2.1.2) and aspartate ammonia-lyase (ASPA, EC 4.3.1.1) resulted in multi-enzyme reaction cascades and, thus, augmentation of the substrate spectrum of the sensors. Electrochemical measurements were carried out in presence of the cofactor β-nicotinamide adenine dinucleotide (NAD+) and the redox mediator hexacyanoferrate (III) (HCFIII). The amperometric detection is mediated by oxidation of hexacyanoferrate (II) (HCFII) at an applied potential of + 0.3 V vs. Ag/AgCl. For each biosensor, optimum working conditions were defined by adjustment of cofactor concentrations, buffer pH, and immobilization procedure. Under these improved conditions, amperometric responses were linear up to 3.0 mM for L-malate and fumarate, respectively, with a corresponding sensitivity of 0.7 μA mM-1 (L-malate biosensor) and 0.4 μA mM-1 (fumarate biosensor). The L-aspartate detection system displayed a linear range of 1.0-10.0 mM with a sensitivity of 0.09 μA mM-1. The sensor characteristics suggest that the developed platform provides a promising method for the detection and differentiation of the three substrates.}, language = {en} } @inproceedings{AchenbachGoettscheKaufholdetal.2011, author = {Achenbach, Timm and G{\"o}ttsche, Joachim and Kaufhold, O. and Hoffschmidt, Bernhard}, title = {Development of an edge module for open volumetric receiver for the use of the radiation at the receiver boundary region}, series = {SolarPACES 2011 : concentrating solar power and chemical energy systems : 20 - 23 September, 2011, Granada, Spain}, booktitle = {SolarPACES 2011 : concentrating solar power and chemical energy systems : 20 - 23 September, 2011, Granada, Spain}, address = {Granada}, pages = {1 CD-ROM}, year = {2011}, language = {en} } @article{SpelthahnSchaffrathCoppeetal.2010, author = {Spelthahn, Heiko and Schaffrath, Sophie and Coppe, Thomas and Rufi, Frederic and Sch{\"o}ning, Michael Josef}, title = {Development of an electrolyte-insulator-semiconductor (EIS) based capacitive heavy metal sensor for the detection of Pb2+ und Cd2+ ions}, series = {Physica status solidi (a) : applications and material science}, volume = {207}, journal = {Physica status solidi (a) : applications and material science}, number = {4}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6300}, doi = {10.1002/pssa.200983306}, pages = {930 -- 934}, year = {2010}, abstract = {Chalcogenide glass materials as membranes for potentiometric sensors for chemical analysis in solutions have been studied since more than 20 years. In this work, an electrolyte-insulator-semiconductor structure was combined with chalcogenide glass membranes prepared by means of the pulsed laser deposition technique. Depending on the membrane composition a selectivity to different ions (Cd2+ and Pb2+) is achieved. The different sensor membranes have been physically characterised using microscopy, ellipsometry, profilometry, atomic force microscopy (AFM), scanning electron microscopy (SEM) and Rutherford backscattering spectrometry (RBS). The electrochemical behaviour has been investigated via capacitance/voltage (C/V) and constant capacitance (ConCap) measurements and results in a Cd2+ sensitivity of 23.1 ± 0.6 mV per decade in a linear range from 7 × 10-6 to 10-2 mol/l and 24.4 ± 0.5 mV per decade in a linear range from 5 × 10-6 to 10-2 mol/l for Pb2+, respectively.}, language = {en} }