@article{FoersterRosenauerFischeretal.1997, author = {F{\"o}rster, Arnold and Rosenauer, A. and Fischer, U. and Gerthsen, D.}, title = {Composition evaluation of InxGa1 - xAs Stranski-Krastanow-island structures by strain state analysis / A. Rosenauer ; U. Fischer ; D. Gerthsen ; A. F{\"o}rster}, series = {Applied physics letters. 71 (1997), H. 26}, journal = {Applied physics letters. 71 (1997), H. 26}, isbn = {0003-6951}, pages = {3868 -- 3870}, year = {1997}, language = {en} } @article{WulfhorstDuweMerseburgetal.2016, author = {Wulfhorst, Helene and Duwe, Anna-Maria and Merseburg, Johannes and Tippk{\"o}tter, Nils}, title = {Compositional analysis of pretreated (beech) wood using differential scanning calorimetry and multivariate data analysis}, series = {Tetrahedron}, volume = {72}, journal = {Tetrahedron}, number = {46}, publisher = {Elsevier}, address = {Amsterdam}, doi = {10.1016/j.tet.2016.04.029}, pages = {7329 -- 7334}, year = {2016}, abstract = {The composition of plant biomass varies depending on the feedstock and pre-treatment conditions and influences its processing in biorefineries. In order to ensure optimal process conditions, the quantitative proportion of the main polymeric components of the pre-treated biomass has to be determined. Current standard procedures for biomass compositional analysis are complex, the measurements are afflicted with errors and therefore often not comparable. Hence, new powerful analytical methods are urgently required to characterize biomass. In this contribution, Differential Scanning Calorimetry (DSC) was applied in combination with multivariate data analysis (MVA) to detect the cellulose content of the plant biomass pretreated by Liquid Hot Water (LHW) and Organosolv processes under various conditions. Unlike conventional techniques, the developed analytic method enables the accurate quantification of monosaccharide content of the plant biomass without any previous sample preparation. It is easy to handle and avoids errors in sample preparation.}, language = {en} } @article{NguyenXuanRabczukNguyenThoietal.2011, author = {Nguyen-Xuan, H. and Rabczuk, T. and Nguyen-Thoi, T. and Tran, Thanh Ngoc and Nguyen-Thanh, N.}, title = {Computation of limit and shakedown loads using a node-based smoothed finite element method}, series = {International Journal for Numerical Methods in Engineering}, volume = {90}, journal = {International Journal for Numerical Methods in Engineering}, number = {3}, publisher = {Wiley}, address = {Weinheim}, issn = {1097-0207}, doi = {10.1002/nme.3317}, pages = {287 -- 310}, year = {2011}, abstract = {This paper presents a novel numerical procedure for computing limit and shakedown loads of structures using a node-based smoothed FEM in combination with a primal-dual algorithm. An associated primal-dual form based on the von Mises yield criterion is adopted. The primal-dual algorithm together with a Newton-like iteration are then used to solve this associated primal-dual form to determine simultaneously both approximate upper and quasi-lower bounds of the plastic collapse limit and the shakedown limit. The present formulation uses only linear approximations and its implementation into finite element programs is quite simple. Several numerical examples are given to show the reliability, accuracy, and generality of the present formulation compared with other available methods.}, language = {en} } @inproceedings{LandAGligorevic2004, author = {Land, Ingmar and A., Peter and Gligorevic, Snjezana}, title = {Computation of symbol-wise mutual information in transmission systems with logAPP decoders and application to EXIT charts}, series = {5th International ITG Conference on Source and Channel Coding (SCC) : January 14 - 16, 2004, Erlangen ; conference record. (ITG-Fachbericht ; 181)}, booktitle = {5th International ITG Conference on Source and Channel Coding (SCC) : January 14 - 16, 2004, Erlangen ; conference record. (ITG-Fachbericht ; 181)}, publisher = {VDE-Verl.}, address = {Berlin [u.a.]}, organization = {International Conference Source and Channel Coding <5, 2004, Erlangen>}, isbn = {3-8007-2802-8}, pages = {195 -- 202}, year = {2004}, language = {en} } @inproceedings{ReimerBraunChenetal.2007, author = {Reimer, Lars and Braun, Carsten and Chen, B.-H. and Ballmann, Josef}, title = {Computational aeroelastic analysis and design of the HIRENASD wind tunnel wing model and tests}, series = {Proceedings / IFASD 2007, CEAS/AIAA/KTH International Forum on Aeroelasticity and Structural Dynamics : June 18 - 21, 2007, Stockholm, Sweden}, booktitle = {Proceedings / IFASD 2007, CEAS/AIAA/KTH International Forum on Aeroelasticity and Structural Dynamics : June 18 - 21, 2007, Stockholm, Sweden}, publisher = {KTH}, address = {Stockholm}, pages = {1 CD-ROM}, year = {2007}, language = {en} } @incollection{BrittenBraunHesseetal.2003, author = {Britten, G. and Braun, Carsten and Hesse, M. and Ballmann, Josef}, title = {Computational aeroelasticity with reduced structural models}, series = {Flow modulation and fluid-structure interaction at airplane wings : research results of the Collaborative Research Center SFB 401 at RWTH Aachen, University of Technology, Aachen, Germany / Josef Ballmann (Ed.) Notes on numerical fluid mechanics and multidisciplinary design. Vol. 84}, booktitle = {Flow modulation and fluid-structure interaction at airplane wings : research results of the Collaborative Research Center SFB 401 at RWTH Aachen, University of Technology, Aachen, Germany / Josef Ballmann (Ed.) Notes on numerical fluid mechanics and multidisciplinary design. Vol. 84}, publisher = {Springer}, address = {Berlin}, isbn = {3-540-40209-8}, pages = {275 -- 299}, year = {2003}, language = {en} } @incollection{BhattaraiFrotscherStaat2018, author = {Bhattarai, Aroj and Frotscher, Ralf and Staat, Manfred}, title = {Computational Analysis of Pelvic Floor Dysfunction}, series = {Women's Health and Biomechanics}, booktitle = {Women's Health and Biomechanics}, publisher = {Springer}, address = {Cham}, isbn = {978-3-319-71574-2}, doi = {10.1007/978-3-319-71574-2_17}, pages = {217 -- 230}, year = {2018}, abstract = {Pelvic floor dysfunction (PFD) is characterized by the failure of the levator ani (LA) muscle to maintain the pelvic hiatus, resulting in the descent of the pelvic organs below the pubococcygeal line. This chapter adopts the modified Humphrey material model to consider the effect of the muscle fiber on passive stretching of the LA muscle. The deformation of the LA muscle subjected to intra-abdominal pressure during Valsalva maneuver is compared with the magnetic resonance imaging (MRI) examination of a nulliparous female. Numerical result shows that the fiber-based Humphrey model simulates the muscle behavior better than isotropic constitutive models. Greater posterior movement of the LA muscle widens the levator hiatus due to lack of support from the anococcygeal ligament and the perineal structure as a consequence of birth-related injury and aging. Old and multiparous females with uncontrolled urogenital and rectal hiatus tend to develop PFDs such as prolapse and incontinence.}, language = {en} } @article{BehbahaniWalugaArltetal.2008, author = {Behbahani, Mehdi and Waluga, C. and Arlt, S. and Behr, M. and Mottaghy, K.}, title = {Computational Analysis of Platelet Aggregation in a Taylor-Couette System}, series = {The International Journal of Artificial Organs. 31 (2008), H. 7}, journal = {The International Journal of Artificial Organs. 31 (2008), H. 7}, isbn = {0391-3988}, pages = {643}, year = {2008}, language = {en} } @article{BhattaraiStaat2018, author = {Bhattarai, Aroj and Staat, Manfred}, title = {Computational comparison of different textile implants to correct apical prolapse in females}, series = {Current Directions in Biomedical Engineering}, volume = {4}, journal = {Current Directions in Biomedical Engineering}, number = {1}, publisher = {De Gruyter}, address = {Berlin}, doi = {10.1515/cdbme-2018-0159}, pages = {661 -- 664}, year = {2018}, abstract = {Prosthetic textile implants of different shapes, sizes and polymers are used to correct the apical prolapse after hysterectomy (removal of the uterus). The selection of the implant before or during minimally invasive surgery depends on the patient's anatomical defect, intended function after reconstruction and most importantly the surgeon's preference. Weakness or damage of the supporting tissues during childbirth, menopause or previous pelvic surgeries may put females in higher risk of prolapse. Numerical simulations of reconstructed pelvic floor with weakened tissues and organ supported by textile product models: DynaMesh®-PRS soft, DynaMesh®-PRP soft and DynaMesh®-CESA from FEG Textiletechnik mbH, Germany are compared.}, language = {en} } @article{MalinowskiFournierHorbachetal.2022, author = {Malinowski, Daniel and Fournier, Yvan and Horbach, Andreas and Frick, Michael and Magliani, Mirko and Kalverkamp, Sebastian and Hildinger, Martin and Spillner, Jan and Behbahani, Mehdi and Hima, Flutura}, title = {Computational fluid dynamics analysis of endoluminal aortic perfusion}, series = {Perfusion}, volume = {0}, journal = {Perfusion}, number = {0}, publisher = {Sage}, address = {London}, issn = {1477-111X}, doi = {10.1177/02676591221099809}, pages = {1 -- 8}, year = {2022}, abstract = {Introduction: In peripheral percutaneous (VA) extracorporeal membrane oxygenation (ECMO) procedures the femoral arteries perfusion route has inherent disadvantages regarding poor upper body perfusion due to watershed. With the advent of new long flexible cannulas an advancement of the tip up to the ascending aorta has become feasible. To investigate the impact of such long endoluminal cannulas on upper body perfusion, a Computational Fluid Dynamics (CFD) study was performed considering different support levels and three cannula positions. Methods: An idealized literature-based- and a real patient proximal aortic geometry including an endoluminal cannula were constructed. The blood flow was considered continuous. Oxygen saturation was set to 80\% for the blood coming from the heart and to 100\% for the blood leaving the cannula. 50\% and 90\% venoarterial support levels from the total blood flow rate of 6 l/min were investigated for three different positions of the cannula in the aortic arch. Results: For both geometries, the placement of the cannula in the ascending aorta led to a superior oxygenation of all aortic blood vessels except for the left coronary artery. Cannula placements at the aortic arch and descending aorta could support supra-aortic arteries, but not the coronary arteries. All positions were able to support all branches with saturated blood at 90\% flow volume. Conclusions: In accordance with clinical observations CFD analysis reveals, that retrograde advancement of a long endoluminal cannula can considerably improve the oxygenation of the upper body and lead to oxygen saturation distributions similar to those of a central cannulation.}, language = {en} }