@inproceedings{Huening2016, author = {H{\"u}ning, Felix}, title = {Power Semiconductors for the automotive 48V board net}, series = {PCIM Europe 2016 Conference Proceedings}, booktitle = {PCIM Europe 2016 Conference Proceedings}, publisher = {VDE Verl.}, address = {Berlin}, isbn = {978-3-8007-4186-1}, pages = {1963 -- 1969}, year = {2016}, language = {en} } @inproceedings{MoehringWulfhorstRothetal.2016, author = {M{\"o}hring, S. and Wulfhorst, H. and Roth, J. and Tippk{\"o}tter, Nils}, title = {Pretreatment strategies for lignocellulosic biomass}, series = {New frontiers of biotech-processes (Himmelfahrtstagung) : 02-04 May 2016, Rhein-Mosel-Halle, Koblenz/Germany}, booktitle = {New frontiers of biotech-processes (Himmelfahrtstagung) : 02-04 May 2016, Rhein-Mosel-Halle, Koblenz/Germany}, publisher = {DECHEMA}, address = {Frankfurt am Main}, pages = {131}, year = {2016}, language = {en} } @inproceedings{RieperGebhardtStucker2016, author = {Rieper, Harald and Gebhardt, Andreas and Stucker, Brent}, title = {Process parameters for Selective Laser Melting of AgCu7}, series = {DDMC, Fraunhofer Direct Digital Manufacturing Conference, 3}, booktitle = {DDMC, Fraunhofer Direct Digital Manufacturing Conference, 3}, publisher = {Fraunhofer-Verlag}, address = {Stuttgart}, isbn = {978-3-8396-1001-5}, pages = {171 -- 176}, year = {2016}, language = {en} } @article{HacklMuellerStaatetal.2016, author = {Hackl, Michael and M{\"u}ller, Lars-Peter and Staat, Manfred and Kahmann, Stephanie Lucina and Wegmann, Kilian}, title = {Proximal phalangeal neck fractures of the hand — a biomechanical comparison of three fixation techniques}, series = {Knee surgery, sports traumatology, arthroscopy}, volume = {Volume 24}, journal = {Knee surgery, sports traumatology, arthroscopy}, number = {Supplement 1}, publisher = {Springer}, address = {Berlin}, issn = {0942-2056}, doi = {10.1007/s00167-016-4080-7}, pages = {148 -- 149}, year = {2016}, abstract = {Plate osteosynthesis of displaced proximal phalangeal neck fractures of the hand allows early mobilization due to a stable internal fixation. Nevertheless, joint stiffness—because of soft tissue irritation—represents a common complication leading to high complication rates. Del Pinal et al. recently reported promising clinical results for a new, minimally invasive fixation technique with a cannulated headless intramedullary compression screw. Hence, the aim of this study was to compare plate fixation of proximal phalangeal neck fractures to less two less invasive techniques: Crossed k-wire fixation and intramedullary screw fixation. We hypothesized that these fixation techniques provide inferior stability when compared to plate osteosynthesis.}, language = {en} } @article{Wollert2016, author = {Wollert, J{\"o}rg}, title = {Rapid Application Development}, series = {Design \& Elektronik}, journal = {Design \& Elektronik}, number = {4}, publisher = {WEKA-Fachmedien}, address = {M{\"u}nchen}, issn = {0933-8667}, pages = {8 -- 11}, year = {2016}, abstract = {Das IoT ist ohne eingebettete Systeme undenkbar. Erst kleine und kleinste Mikrocontroller mit intelligenten Kommunikationsschnittstellen und Anbindung ans Internet erm{\"o}glichen sinnvolles und fl{\"a}chendeckendes Einsammeln von Daten. Doch wie kompliziert ist der Einstieg in die Embedded-Welt? Dieser Artikel gibt Einblick, wie die »Arduino-Plattform« die Einstiegsh{\"u}rden f{\"u}r eingebettete Systeme dramatisch reduzieren kann.}, language = {de} } @inproceedings{KrollLudwigs2016, author = {Kroll-Ludwigs, Kathrin}, title = {Rechtswahl und Gerichtsstandsvereinbarungen}, series = {Die neue Europ{\"a}ische Erbrechtsverordnung}, booktitle = {Die neue Europ{\"a}ische Erbrechtsverordnung}, editor = {Lipp, Volker and M{\"u}nch, Joachim}, publisher = {Deutscher Notarverlag}, address = {Bonn}, isbn = {978-3-95646-062-3}, pages = {65 -- 97}, year = {2016}, language = {de} } @article{KrollLudwigs2016, author = {Kroll-Ludwigs, Kathrin}, title = {Rechtswahl und Gerichtsstandsvereinbarungen nach der Europ{\"a}ischen Erbrechtsverordnung}, series = {Notar : Monatsschrift f{\"u}r die gesamte notarielle Praxis}, journal = {Notar : Monatsschrift f{\"u}r die gesamte notarielle Praxis}, number = {3}, publisher = {DNotV-Verl.}, address = {Berlin}, pages = {75 -- 85}, year = {2016}, language = {de} } @article{HacklLeschingerStaatetal.2016, author = {Hackl, Michael and Leschinger, T. and Staat, Manfred and M{\"u}ller, Lars-Peter and Wegmann, Kilian}, title = {Reconstruction of the interosseous membrane in the Essex Lopresti lesion — a biomechanical evaluation}, series = {Knee surgery, sports traumatology, arthroscopy}, volume = {Volume 24}, journal = {Knee surgery, sports traumatology, arthroscopy}, number = {Supplement 1}, publisher = {Springer}, address = {Berlin}, issn = {0942-2056}, doi = {10.1007/s00167-016-4080-7}, pages = {130 -- 131}, year = {2016}, abstract = {Surgical reconstruction of the interosseous membrane (IOM) could restore longitudinal forearm stability to avoid persisting disability due to capituloradial and ulnocarpal impingement in Essex Lopresti lesions. This biomechanical study aimed to assess longitudinal forearm stability of intact specimens, after sectioning of the IOM and after reconstruction with a TightRope construct using either a single or double bundle technique.}, language = {en} } @article{AlbannaConzenWeissetal.2016, author = {Albanna, W. and Conzen, C. and Weiss, M. and Clusmann, H. and Fuest, M. and Mueller, M. and Brockmann, M.A. and Vilser, W. and Schmidt-Trucks{\"a}ss, A. and Hoellig, A. and Seiz, M. and Thom{\´e}, C. and Kotliar, Konstantin and Schubert, G.A.}, title = {Retinal Vessel Analysis (RVA) in the context of subarachnoid hemorrhage: A proof of concept study}, series = {PLoS ONE}, volume = {11}, journal = {PLoS ONE}, number = {7}, publisher = {PLOS}, address = {San Francisco}, issn = {1932-6203}, doi = {10.1371/journal.pone.0158781}, pages = {13 Seiten}, year = {2016}, abstract = {Background Timely detection of impending delayed cerebral ischemia after subarachnoid hemorrhage (SAH) is essential to improve outcome, but poses a diagnostic challenge. Retinal vessels as an embryological part of the intracranial vasculature are easily accessible for analysis and may hold the key to a new and non-invasive monitoring technique. This investigation aims to determine the feasibility of standardized retinal vessel analysis (RVA) in the context of SAH. Methods In a prospective pilot study, we performed RVA in six patients awake and cooperative with SAH in the acute phase (day 2-14) and eight patients at the time of follow-up (mean 4.6±1.7months after SAH), and included 33 age-matched healthy controls. Data was acquired using a manoeuvrable Dynamic Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and neurovascular coupling. Results Image quality was satisfactory in the majority of cases (93.3\%). In the acute phase after SAH, retinal arteries were significantly dilated when compared to the control group (124.2±4.3MU vs 110.9±11.4MU, p<0.01), a difference that persisted to a lesser extent in the later stage of the disease (122.7±17.2MU, p<0.05). Testing for neurovascular coupling showed a trend towards impaired primary vasodilation and secondary vasoconstriction (p = 0.08, p = 0.09 resp.) initially and partial recovery at the time of follow-up, indicating a relative improvement in a time-dependent fashion. Conclusion RVA is technically feasible in patients with SAH and can detect fluctuations in vessel diameter and autoregulation even in less severely affected patients. Preliminary data suggests potential for RVA as a new and non-invasive tool for advanced SAH monitoring, but clinical relevance and prognostic value will have to be determined in a larger cohort.}, language = {en} } @inproceedings{BonneyNagelSchuba2016, author = {Bonney, Gregor and Nagel, Stefan and Schuba, Marko}, title = {Risiko Smart Home - Angriff auf ein Babymonitorsystem}, series = {Proceedings of DACH Security 2016, Klagenfurt, Austria, September 2016}, booktitle = {Proceedings of DACH Security 2016, Klagenfurt, Austria, September 2016}, editor = {Schartner, P.}, pages = {371 -- 378}, year = {2016}, abstract = {Unser Zuhause wird zunehmend intelligenter. Smart Homes bieten uns die Steuerung von Haus- oder Unterhaltungstechnik bequem vom Smartphone aus. Junge Familien nutzen die Technologie, um mittels vernetzten Babymonitorsystemen ihren Nachwuchs von {\"u}berall aus im Blick zu haben. Davon auszugehen, dass solche Systeme mit einem Fokus auf Sicherheit entwickelt wurden, um die sehr pers{\"o}nlichen Daten zu sch{\"u}tzen, ist jedoch ein Trugschluss. Die Untersuchung eines handels{\"u}blichen und keineswegs billigen Systems zeigt, dass die Ger{\"a}te sehr einfach kompromittiert und missbraucht werden k{\"o}nnen.}, language = {de} }