@inproceedings{Ritz2007, author = {Ritz, Thomas}, title = {Die benutzerzentrierte Entwicklung mobiler Unternehmenssoftware}, series = {MMS 2007: Mobilit{\"a}t und mobile Informationssysteme : 2nd conference of GI-Fachgruppe MMS ; March 6th, 2007 in Aachen, Germany}, booktitle = {MMS 2007: Mobilit{\"a}t und mobile Informationssysteme : 2nd conference of GI-Fachgruppe MMS ; March 6th, 2007 in Aachen, Germany}, editor = {K{\"o}nig-Ries, Brigitta}, publisher = {Ges. f{\"u}r Informatik}, address = {Bonn}, isbn = {978-3-88579-198-0}, pages = {23 -- 35}, year = {2007}, language = {de} } @inproceedings{LeiseBreuerAltherretal.2020, author = {Leise, Philipp and Breuer, Tim and Altherr, Lena and Pelz, Peter F.}, title = {Development, validation and assessment of a resilient pumping system}, series = {Proceedings of the Joint International Resilience Conference, JIRC2020}, booktitle = {Proceedings of the Joint International Resilience Conference, JIRC2020}, isbn = {978-90-365-5095-6}, pages = {97 -- 100}, year = {2020}, abstract = {The development of resilient technical systems is a challenging task, as the system should adapt automatically to unknown disturbances and component failures. To evaluate different approaches for deriving resilient technical system designs, we developed a modular test rig that is based on a pumping system. On the basis of this example system, we present metrics to quantify resilience and an algorithmic approach to improve resilience. This approach enables the pumping system to automatically react on unknown disturbances and to reduce the impact of component failures. In this case, the system is able to automatically adapt its topology by activating additional valves. This enables the system to still reach a minimum performance, even in case of failures. Furthermore, timedependent disturbances are evaluated continuously, deviations from the original state are automatically detected and anticipated in the future. This allows to reduce the impact of future disturbances and leads to a more resilient system behaviour.}, language = {en} } @inproceedings{GrundAltherr2023, author = {Grund, Raphael M. and Altherr, Lena}, title = {Development of an open source energy disaggregation tool for the home automation platform Home Assistant}, series = {Tagungsband AALE 2023 : mit Automatisierung gegen den Klimawandel}, booktitle = {Tagungsband AALE 2023 : mit Automatisierung gegen den Klimawandel}, editor = {Reiff-Stephan, J{\"o}rg and J{\"a}kel, Jens and Schwarz, Andr{\´e}}, publisher = {le-tex publishing services GmbH}, address = {Leipzig}, isbn = {978-3-910103-01-6}, doi = {10.33968/2023.02}, pages = {11 -- 20}, year = {2023}, abstract = {In order to reduce energy consumption of homes, it is important to make transparent which devices consume how much energy. However, power consumption is often only monitored aggregated at the house energy meter. Disaggregating this power consumption into the contributions of individual devices can be achieved using Machine Learning. Our work aims at making state of the art disaggregation algorithms accessibe for users of the open source home automation platform Home Assistant.}, language = {en} } @inproceedings{NursinskiStolbergGangatharanCzarnecki2016, author = {Nursinski-Stolberg, Andr{\´e} and Gangatharan, Kiritharan and Czarnecki, Christian}, title = {Development of a subject-oriented reference process model for the telecommunications industry}, series = {GI Edition Proceedings Band 259 INFORMATIK 2016}, booktitle = {GI Edition Proceedings Band 259 INFORMATIK 2016}, editor = {Mayr, Heinrich C. and Pinzger, Martin}, publisher = {Gesellschaft f{\"u}r Informatik e.V.}, address = {Bonn}, isbn = {9783885796534}, issn = {1617-5468}, pages = {699 -- 712}, year = {2016}, abstract = {Generally the usage of reference models can be structured top-down or bottom-up. The practical need of agile change and flexible organizational implementation requires a consistent mapping to an operational level. In this context, well-established reference process models are typically structured top-down. The subject-oriented Business Process Management (sBPM) offers a modeling concept that is structured bottom-up and concentrates on the process actors on an operational level. This paper applies sBPM to the enhanced Telecom Operations Map (eTOM), a well-accepted reference process model in the telecommunications industry. The resulting design artifact is a concrete example for a combination of a bottom-up and top-down developed reference model. The results are evaluated and confirmed in practical context through the involvement of the industry body TMForum.}, language = {en} } @inproceedings{TischbeinKeanVertgewalletal.2023, author = {Tischbein, Franziska and Kean, Kilian and Vertgewall, Chris Martin and Ulbig, Andreas and Altherr, Lena}, title = {Determination of the topology of low-voltage distribution grids using cluster methods}, series = {27th International Conference on Electricity Distribution (CIRED 2023)}, booktitle = {27th International Conference on Electricity Distribution (CIRED 2023)}, publisher = {IEEE}, isbn = {978-1-83953-855-1}, doi = {10.1049/icp.2023.0478}, pages = {1 -- 5}, year = {2023}, abstract = {Due to the decarbonization of the energy sector, the electric distribution grids are undergoing a major transformation, which is expected to increase the load on the operating resources due to new electrical loads and distributed energy resources. Therefore, grid operators need to gradually move to active grid management in order to ensure safe and reliable grid operation. However, this requires knowledge of key grid variables, such as node voltages, which is why the mass integration of measurement technology (smart meters) is necessary. Another problem is the fact that a large part of the topology of the distribution grids is not sufficiently digitized and models are partly faulty, which means that active grid operation management today has to be carried out largely blindly. It is therefore part of current research to develop methods for determining unknown grid topologies based on measurement data. In this paper, different clustering algorithms are presented and their performance of topology detection of low voltage grids is compared. Furthermore, the influence of measurement uncertainties is investigated in the form of a sensitivity analysis.}, language = {en} } @inproceedings{OstkottePetersHueningetal.2022, author = {Ostkotte, Sebastian and Peters, Constantin and H{\"u}ning, Felix and Bragard, Michael}, title = {Design, implementation and verification of an rotational incremental position encoder based on the magnetic Wiegand effect}, series = {2022 ELEKTRO (ELEKTRO)}, booktitle = {2022 ELEKTRO (ELEKTRO)}, publisher = {IEEE}, isbn = {978-1-6654-6726-1}, issn = {2691-0616}, doi = {10.1109/ELEKTRO53996.2022.9803477}, pages = {6 Seiten}, year = {2022}, abstract = {This paper covers the use of the magnetic Wiegand effect to design an innovative incremental encoder. First, a theoretical design is given, followed by an estimation of the achievable accuracy and an optimization in open-loop operation. Finally, a successful experimental verification is presented. For this purpose, a permanent magnet synchronous machine is controlled in a field-oriented manner, using the angle information of the prototype.}, language = {en} } @inproceedings{Czarnecki2016, author = {Czarnecki, Christian}, title = {Design und Nutzung einer industriespezifischen Referenzarchitektur f{\"u}r die Telekommunikationsindustrie}, series = {GI Edition Proceedings Band 259 INFORMATIK 2016. 26.-30. September 2016 Klagenfurt}, booktitle = {GI Edition Proceedings Band 259 INFORMATIK 2016. 26.-30. September 2016 Klagenfurt}, editor = {Mayr, Heinrich C. and Pinzger, Martin and Gesellschaft f{\"u}r Informatik e. V. (GI),}, publisher = {K{\"o}llen}, address = {Bonn}, isbn = {9783885796534}, issn = {1617-5468}, pages = {807 -- 814}, year = {2016}, abstract = {Zur Unterst{\"u}tzung des Transformationsbedarfs von Telekommunikationsunternehmen sind die Referenzmodelle des TM Forums in der Praxis weltweit anerkannt. Dabei findet jedoch meist eine losgel{\"o}ste Nutzung f{\"u}r spezifische Einzelthemen statt. Daher f{\"u}hrt dieser Artikel die bestehenden Inhalte in einer industriespezifischen, {\"u}bergreifenden Referenzarchitektur zusammen. Der Fokus liegt auf den Ebenen Aufbauorganisation, Prozesse, Applikationen und Daten. Dar{\"u}ber hinaus werden inhaltliche Architekturdom{\"a}nen zur Strukturierung angeboten. Die Referenzarchitektur ist hierarchisch aufgebaut und wird hier beispielhaft f{\"u}r ausgew{\"a}hlte, aggregierte Inhalte beschrieben. Als erste Evaluation wird die Anwendung der Referenzarchitektur in drei Praxisprojekten erl{\"a}utert.}, language = {de} } @inproceedings{StopforthDavrajhFerrein2017, author = {Stopforth, Riaan and Davrajh, Shaniel and Ferrein, Alexander}, title = {Design considerations of the duo fugam dual rotor UAV}, series = {2017 Pattern Recognition Association of South Africa and Robotics and Mechatronics (PRASA-RobMech)}, booktitle = {2017 Pattern Recognition Association of South Africa and Robotics and Mechatronics (PRASA-RobMech)}, isbn = {978-1-5386-2314-5}, doi = {10.1109/RoboMech.2017.8261115}, pages = {7 -- 13}, year = {2017}, language = {en} } @inproceedings{BragardGottschlichDeDoncker2011, author = {Bragard, Michael and Gottschlich, J. and De Doncker, R. W.}, title = {Design and realization of a credit card size driver stage for high power thyristor based devices with integrated MOS structure}, series = {2011 IEEE 8th International Conference on Power Electronics and ECCE Asia (ICPE \& ECCE 2011) : Jeju, South Korea, 30 May 2011 - 3 June 2011 / [co-sponsored by the Korean Institute of Power Electronics ...]}, booktitle = {2011 IEEE 8th International Conference on Power Electronics and ECCE Asia (ICPE \& ECCE 2011) : Jeju, South Korea, 30 May 2011 - 3 June 2011 / [co-sponsored by the Korean Institute of Power Electronics ...]}, publisher = {IEEE}, address = {Piscataway, NJ}, isbn = {978-1-61284-958-4 (Print)}, doi = {10.1109/ICPE.2011.5944661}, pages = {1182 -- 1189}, year = {2011}, language = {en} } @inproceedings{BragardSoltauDeDonckeretal.2010, author = {Bragard, Michael and Soltau, N. and De Doncker, R. W. and Schmiegel, A.}, title = {Design and implementation of a 5 kW photovoltaic system with li-ion battery and additional DC-DC converter}, series = {2010 IEEE Energy Conversion Congress and Exposition (ECCE 2010) : Atlanta, Georgia, USA, 12 - 16 September 2010 / [sponsored by the IEEE Power Electronics and Industry Applications Societies]}, booktitle = {2010 IEEE Energy Conversion Congress and Exposition (ECCE 2010) : Atlanta, Georgia, USA, 12 - 16 September 2010 / [sponsored by the IEEE Power Electronics and Industry Applications Societies]}, publisher = {IEEE}, address = {Piscataway, NJ}, isbn = {978-1-4244-5286-6 (Print)}, doi = {10.1109/ECCE.2010.5618220}, pages = {2944 -- 2949}, year = {2010}, language = {en} }