@article{FeldmannDoeringKuhnhenneetal.2008, author = {Feldmann, Markus and D{\"o}ring, Bernd and Kuhnhenne, Markus and Sedlacek, Gerhard}, title = {Zum Thema "Nachhaltigkeit" in der Stahlbauindustrie}, series = {Stahlbau}, volume = {Vol. 77}, journal = {Stahlbau}, number = {Iss. 10}, issn = {0038-9145}, pages = {713 -- 720}, year = {2008}, language = {de} } @article{HagenkampBlankeDoering2021, author = {Hagenkamp, Markus and Blanke, Tobias and D{\"o}ring, Bernd}, title = {Thermoelectric building temperature control: a potential assessment}, series = {International Journal of Energy and Environmental Engineering}, volume = {13}, journal = {International Journal of Energy and Environmental Engineering}, publisher = {Springer}, address = {Berlin}, doi = {10.1007/s40095-021-00424-x}, pages = {241 -- 254}, year = {2021}, abstract = {This study focuses on thermoelectric elements (TEE) as an alternative for room temperature control. TEE are semi-conductor devices that can provide heating and cooling via a heat pump effect without direct noise emissions and no refrigerant use. An efficiency evaluation of the optimal operating mode is carried out for different numbers of TEE, ambient temperatures, and heating loads. The influence of an additional heat recovery unit on system efficiency and an unevenly distributed heating demand are examined. The results show that TEE can provide heat at a coefficient of performance (COP) greater than one especially for small heating demands and high ambient temperatures. The efficiency increases with the number of elements in the system and is subject to economies of scale. The best COP exceeds six at optimal operating conditions. An additional heat recovery unit proves beneficial for low ambient temperatures and systems with few TEE. It makes COPs above one possible at ambient temperatures below 0 ∘C. The effect increases efficiency by maximal 0.81 (from 1.90 to 2.71) at ambient temperature 5 K below room temperature and heating demand Q˙h=100W but is subject to diseconomies of scale. Thermoelectric technology is a valuable option for electricity-based heat supply and can provide cooling and ventilation functions. A careful system design as well as an additional heat recovery unit significantly benefits the performance. This makes TEE superior to direct current heating systems and competitive to heat pumps for small scale applications with focus on avoiding noise and harmful refrigerants.}, language = {en} } @article{DoeringHechlerWeberetal.2004, author = {D{\"o}ring, Bernd and Hechler, O. and Weber, F. and Sedlacek, Gerhard}, title = {Thermische Aktivierung von Fertigteildecken}, series = {HLH L{\"u}ftung/Klima, Heizung/Sanit{\"a}r, Geb{\"a}udetechnik}, volume = {Jg. 55}, journal = {HLH L{\"u}ftung/Klima, Heizung/Sanit{\"a}r, Geb{\"a}udetechnik}, number = {Nr. 5}, issn = {1436-5103}, pages = {24 -- 35}, year = {2004}, language = {de} } @article{DoeringKendrickLawson2013, author = {D{\"o}ring, Bernd and Kendrick, C. and Lawson, R. M.}, title = {Thermal capacity of composite floor slabs}, series = {Energy and buildings}, volume = {Vol. 67}, journal = {Energy and buildings}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1872-6178 (E-Journal); 0378-7788 (Print)}, pages = {531 -- 539}, year = {2013}, language = {en} } @article{DoeringRegerKuhnhenneetal.2015, author = {D{\"o}ring, Bernd and Reger, Vitali and Kuhnhenne, Markus and Feldmann, Markus and Kesti, Jyrki and Lawson, Mark and Botti, Andrea}, title = {Steel solutions for enabling zero-energy buildings}, series = {Steel Construction - Design and Research}, volume = {8}, journal = {Steel Construction - Design and Research}, number = {3}, publisher = {Ernst \& Sohn}, address = {Berlin}, issn = {1867-0539}, doi = {10.1002/stco.201510029}, pages = {194 -- 200}, year = {2015}, language = {en} } @article{KuckDoering1997, author = {Kuck, Herbert and D{\"o}ring, Bernd}, title = {Regenerative Energien in Landesbauten : Land NRW unterst{\"u}tzt Einsatz erneuerbarer Energien 1997 mit 15 Mio. DM}, series = {Die Bauverwaltung mit Bauamt und Gemeindebau}, volume = {Bd. 70}, journal = {Die Bauverwaltung mit Bauamt und Gemeindebau}, number = {H. 8}, issn = {0005-6847}, pages = {384 -- 386}, year = {1997}, language = {de} } @article{RegerKuhnhenneHachuletal.2019, author = {Reger, Vitali and Kuhnhenne, Markus and Hachul, Helmut and D{\"o}ring, Bernd and Blanke, Tobias and G{\"o}ttsche, Joachim}, title = {Plusenergiegeb{\"a}ude 2.0 in Stahlleichtbauweise}, series = {Stahlbau}, volume = {88}, journal = {Stahlbau}, number = {6}, publisher = {Ernst \& Sohn}, address = {Berlin}, issn = {1437-1049 (E-journal), 0038-9145 (print)}, doi = {10.1002/stab.201900034}, pages = {522 -- 528}, year = {2019}, language = {de} } @article{DoeringFeldmannKuhnhenneetal.2011, author = {D{\"o}ring, Bernd and Feldmann, Markus and Kuhnhenne, Markus and M{\"u}ller, Dirk}, title = {Phasenwechselmaterial im Metallleichtbau zur Optimierung von Energieeffizienz und sommerlicher Raumtemperatur}, series = {Stahlbau}, volume = {Vol. 80}, journal = {Stahlbau}, number = {Iss. 9}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1049 (E-Journal); 0038-9145 (Print)}, pages = {666 -- 672}, year = {2011}, language = {de} } @article{RegerDoeringKuhnhenne2016, author = {Reger, V. and D{\"o}ring, Bernd and Kuhnhenne, M.}, title = {Passive und aktive Maßnahmen zur Fl{\"a}chenk{\"u}hlung im Stahl(leicht)bau}, series = {Bauingenieur}, volume = {91}, journal = {Bauingenieur}, number = {Jul/Aug}, publisher = {VDI Fachmedien}, address = {D{\"u}sseldorf}, issn = {0005-6650}, doi = {10.37544/0005-6650-2016-07-08-63}, pages = {309 -- 316}, year = {2016}, abstract = {Mit steigenden D{\"a}mmstandards und h{\"o}heren Komfortanforderungen der Nutzer ger{\"a}t die Problematik der sommerlichen {\"U}berhitzung zunehmend in den Fokus. Um die {\"U}berhitzung m{\"o}glichst gering zu halten, sind Maßnahmen und L{\"o}sungen zu entwickeln, die den potenziellen K{\"u}hlbedarf eines Geb{\"a}udes vermeiden sowie reduzieren. Im Rahmen des europ{\"a}ischen Forschungsprojektes BATIMASS wurden Techniken untersucht, die die sommerliche Raumtemperatur ohne zus{\"a}tzliche K{\"u}hlung (passiv) oder aber mit energieeffizienter wasserbasierter Fl{\"a}chenk{\"u}hlung (aktiv) reduzieren und die besonders f{\"u}r Geb{\"a}ude in Stahl(leicht)bauweise geeignet sind. Daf{\"u}r wurde die Methodik der thermisch {\"a}quivalenten Decke weiterentwickelt, um das thermische Verhalten von Profilblechdecken in Geb{\"a}uden f{\"u}r beide L{\"o}sungsans{\"a}tze analysieren zu k{\"o}nnen. Dar{\"u}ber hinaus wurde der Einsatz von Phasenwechselmaterial (PCM) zur Steigerung der Speicherf{\"a}higkeit von leichten Decken mit besonders geringer thermischer Masse in Simulationen sowie im Labor untersucht und bewertet.}, language = {de} } @article{RegerKuhnhenneEbbertetal.2020, author = {Reger, Vitali and Kuhnhenne, Markus and Ebbert, Thiemo and Hachul, Helmut and Blanke, Tobias and D{\"o}ring, Bernd}, title = {Nutzung erneuerbarer Energien durch thermische Aktivierung von Komponenten aus Stahl}, series = {Stahlbau}, volume = {2020}, journal = {Stahlbau}, number = {Volume 89, Issue 6512-519}, publisher = {Ernst \& Sohn}, address = {Berlin}, issn = {1437-1049}, doi = {10.1002/stab.202000031}, pages = {512 -- 519}, year = {2020}, abstract = {Die Versorgung von Neubauten soll m{\"o}glichst weitgehend unabh{\"a}ngig von fossilen Energietr{\"a}gern erfolgen. Erneuerbare Energien spielen daf{\"u}r eine gewichtige Rolle. Eine gute M{\"o}glichkeit, erneuerbare Energien ohne viel zus{\"a}tzlichen Aufwand nutzbar zu machen, ist, bereits vorhandenen Komponenten im Geb{\"a}ude zus{\"a}tzliche Funktionen zu geben. Hier kann bspw. die Fassade oder das Dach solarthermisch aktiviert oder durch Fotovoltaikmodule erg{\"a}nzt werden. Auch Tiefgr{\"u}ndungen k{\"o}nnen neben der statischen Funktion noch eine geothermische Funktion zur Aufnahme oder Abgabe von W{\"a}rme erhalten. Neben der Erzeugung bietet sich auch f{\"u}r die Verteilung der W{\"a}rme oder K{\"a}lte im Geb{\"a}ude die Integration in Bauteile an. Hier kann bspw. der Boden durch eine Fußbodenheizung oder die Decke durch Deckenstrahlplatten aktiviert werden. Im Rahmen der Ver{\"o}ffentlichung wird auf die thermische Aktivierung von Stahlkomponenten eingegangen. Es wird eine L{\"o}sung vorgestellt, die vorgeh{\"a}ngte hinterl{\"u}ftete Stahlfassade (VHF) solarthermisch zu aktivieren. Außerdem werden zwei M{\"o}glichkeiten zur geothermischen Aktivierung von Tiefgr{\"u}ndungen mittels Stahlpf{\"a}hlen gezeigt. Zuletzt wird ein System zur thermischen Aktivierung von Stahltrapezprofilen an der Decke erl{\"a}utert, welches W{\"a}rme zuf{\"u}hren oder bei Bedarf abf{\"u}hren kann.}, language = {de} }