@inproceedings{KonradChudobaButenwegetal.2003, author = {Konrad, M. and Chudoba, Rostislav and Butenweg, Christoph and Bruckermann, O.}, title = {Textile reinforced concrete. Part II: Multi-level modeling concept}, series = {Digital proceedings / IKM 2003, proceedings 16th International Conference on the Applications of Computer Science and Mathematics in Architecture and Civil Engineering [Elektronische Ressource : 10. - 12. Juni 2003, Weimar] / Bauhaus-Universit{\"a}t Weimar. Ed.: K. G{\"u}rlebeck; L. Hempel; C. K{\"o}nke}, booktitle = {Digital proceedings / IKM 2003, proceedings 16th International Conference on the Applications of Computer Science and Mathematics in Architecture and Civil Engineering [Elektronische Ressource : 10. - 12. Juni 2003, Weimar] / Bauhaus-Universit{\"a}t Weimar. Ed.: K. G{\"u}rlebeck; L. Hempel; C. K{\"o}nke}, publisher = {IKM}, address = {Weimar}, organization = {Internationales Kolloquium {\"u}ber Anwendungen der Informatik und Mathematik in Architektur und Bauwesen <16, 2003, Weimar>}, pages = {1 -- 11}, year = {2003}, language = {en} } @inproceedings{SurteesGillespieKernetal.2004, author = {Surtees, A. J. and Gillespie, A. and Kern, Alexander and Rousseau, A.}, title = {DEVELOPMENT OF A RISK ASSESSMENT CALCULATOR BASED ON A SIMPLIFIED FORM OF THE IEC 62305-2 STANDARD ON LIGHTNING PROTECTION}, year = {2004}, abstract = {Neue Blitzschutznorm IEC 62305. Entwicklung einer einfachen Software zur Risikoabw{\"a}gung}, language = {en} } @inproceedings{KernHeidlerSeeversetal.2004, author = {Kern, Alexander and Heidler, Fridolin and Seevers, M. and Zischank, Wolfgang J.}, title = {Magnetic Fields and Induced Voltages in case of a Direct Strike - Comparison of Results obtained from Measurements at a Scaled Building to those of IEC 62305-4}, isbn = {0304-3886}, year = {2004}, abstract = {In the paper the results obtained from experiments at a modelled reinforced building in case of a direct lightning strike are compared with calculations. The comparison includes peak values of the magnetic field Hmax, its derivative (dH/dt)max and of induced voltages umax in typical cable routings. The experiments are performed at a 1:6 scaled building and the results are extrapolated using the similarity relations theory. The calculations are based on the approximate formulae given in IEC 62305-4 and have to be supplemented by a rough estimation of the additional shielding effect of a second reinforcement layer. The comparison shows, that the measured peak values of the magnetic field and its derivative are mostly lower than the calculated. The induced voltages are in good agreement. Hence, calculations of the induced voltages based on IEC 62305-4 are a good method for lightning protection studies of buildings, where the reinforcement is used as a grid-like electromagnetic shield.}, subject = {Blitz}, language = {en} } @inproceedings{ZischankHeidlerWiesingeretal.2004, author = {Zischank, Wolfgang J. and Heidler, Fridolin and Wiesinger, J. and Stimper, K. and Kern, Alexander and Seevers, M.}, title = {Magnetic Fields and Induced Voltages inside LPZ 1 Measured at a 1:6 Scale Model Building}, year = {2004}, abstract = {Laborexperimente zu Blitzschutzzonen in Stahlbetongeb{\"a}uden anhand eines Modells im Maßstab 1:6}, language = {en} } @inproceedings{MeskourisButenwegMistleretal.2004, author = {Meskouris, Konstantin and Butenweg, Christoph and Mistler, Michael and Kuhlmann, Wolfram}, title = {Seismic behaviour of historic masonry buildings}, series = {7th National Congress on Mechanics : Chania, Crete, June 24 - 26, 2004 ; proceedings / ed. A. Kounadis ....}, booktitle = {7th National Congress on Mechanics : Chania, Crete, June 24 - 26, 2004 ; proceedings / ed. A. Kounadis ....}, publisher = {Hellenic Society for Theoretical and Applied Mechanics}, address = {Chania}, organization = {National Congress on Mechanics <7, 2004, Chania, Crete>}, pages = {47 -- 49}, year = {2004}, language = {en} } @inproceedings{KuhlmannButenwegLopezetal.2004, author = {Kuhlmann, Wolfram and Butenweg, Christoph and Lopez, Marijen and Fernandez, Sebastian}, title = {Seismic vulnerability assessment of the historic Aachen Cathedral}, series = {Conference proceedings / 13th World Conference on Earthquake Engineering [Vancouver, British Columbia, Canada, August 1 - 6, 2004] / [hosted by CAEE/ACGP, Canadian Association for Earthquake Engineering]}, booktitle = {Conference proceedings / 13th World Conference on Earthquake Engineering [Vancouver, British Columbia, Canada, August 1 - 6, 2004] / [hosted by CAEE/ACGP, Canadian Association for Earthquake Engineering]}, publisher = {CAEE}, address = {Vancouver}, organization = {World Conference on Earthquake Engineering <13, 2004, Vancouver>}, pages = {1 -- 14}, year = {2004}, language = {en} } @inproceedings{KobButenweg2004, author = {Kob, Malte and Butenweg, Christoph}, title = {A finite element model of the interaction between intra-and extralaryngeal muscles}, series = {International Conference on Voice Physiology and Biomechanics, August 18-20, 2004, Marseille, France}, booktitle = {International Conference on Voice Physiology and Biomechanics, August 18-20, 2004, Marseille, France}, organization = {International Conference on Voice Physiology and Biomechanics <2004, Marseille>}, pages = {1 -- 2}, year = {2004}, language = {en} } @inproceedings{KalkerTollHolleretal.2004, author = {Kalker, Ines and Toll, B. and Holler, Stefan and Butenweg, Christoph and Topping, B. H. V. and Mota Soares, C. A.}, title = {Capacity analysis of textile retrofitted unreinforced masonry}, series = {Proceedings of the Seventh International Conference on Computational Structures Technology : [Lisbon, Portugal, 7 - 9 September 2004] / ed. by B. H. V. Topping ...}, booktitle = {Proceedings of the Seventh International Conference on Computational Structures Technology : [Lisbon, Portugal, 7 - 9 September 2004] / ed. by B. H. V. Topping ...}, publisher = {Civil-Comp Press}, address = {Stirling}, organization = {International Conference on Computational Structures Technology <7, 2004, Lissabon>}, isbn = {0-948749-95-4}, doi = {10.4203/ccp.79.194}, pages = {431 -- 432}, year = {2004}, language = {en} } @inproceedings{MistlerButenwegAnthoine2004, author = {Mistler, M. and Butenweg, Christoph and Anthoine, A.}, title = {Evaluation of the failure criterion for masonry by homogenisation}, series = {Proceedings of the Seventh International Conference on Computational Structures Technology : [Lisbon, Portugal, 7 - 9 September 2004] / ed. by B. H. V. Topping and C.A. Mota Soares}, booktitle = {Proceedings of the Seventh International Conference on Computational Structures Technology : [Lisbon, Portugal, 7 - 9 September 2004] / ed. by B. H. V. Topping and C.A. Mota Soares}, publisher = {Civil-Comp Press}, address = {Stirling}, organization = {International Conference on Computational Structures Technology <7, 2004, Lissabon>}, isbn = {0-948749-95-4}, doi = {10.4203/ccp.79.201}, pages = {16 Seiten}, year = {2004}, language = {en} } @inproceedings{BruessermannDeuster2005, author = {Br{\"u}ssermann, Klaus and Deuster, M.}, title = {Temperature measurement to optimise the burning process}, year = {2005}, abstract = {One of the most important parameters in a burning chamber - in power stations, in waste to energy plants - is the temperature. This temperature is in the range of 700-1500 °C - one of the most advanced measuring methods being the acoustic pyrometry with the possibility of producing temperature mapping in one level of the burning chamber - comparable to computer tomography. The results of these measurements discussed in the presentation can be used - to fulfil the legal requirements in the FRG or in the EU - to equalise the temperature in one level of the burning chamber to optimise the steam production (better efficiency of the plant) and to minimise the production of temperature controlled flue gas components (NO, CO a. o.) - to control the SNCR-process if used.}, subject = {Pyrometrie}, language = {en} }