@article{PoghossianJablonskiMolinnusetal.2020, author = {Poghossian, Arshak and Jablonski, Melanie and Molinnus, Denise and Wege, Christina and Sch{\"o}ning, Michael Josef}, title = {Field-Effect Sensors for Virus Detection: From Ebola to SARS-CoV-2 and Plant Viral Enhancers}, series = {Frontiers in Plant Science}, volume = {11}, journal = {Frontiers in Plant Science}, number = {Article 598103}, publisher = {Frontiers}, address = {Lausanne}, doi = {10.3389/fpls.2020.598103}, pages = {1 -- 14}, year = {2020}, abstract = {Coronavirus disease 2019 (COVID-19) is a novel human infectious disease provoked by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Currently, no specific vaccines or drugs against COVID-19 are available. Therefore, early diagnosis and treatment are essential in order to slow the virus spread and to contain the disease outbreak. Hence, new diagnostic tests and devices for virus detection in clinical samples that are faster, more accurate and reliable, easier and cost-efficient than existing ones are needed. Due to the small sizes, fast response time, label-free operation without the need for expensive and time-consuming labeling steps, the possibility of real-time and multiplexed measurements, robustness and portability (point-of-care and on-site testing), biosensors based on semiconductor field-effect devices (FEDs) are one of the most attractive platforms for an electrical detection of charged biomolecules and bioparticles by their intrinsic charge. In this review, recent advances and key developments in the field of label-free detection of viruses (including plant viruses) with various types of FEDs are presented. In recent years, however, certain plant viruses have also attracted additional interest for biosensor layouts: Their repetitive protein subunits arranged at nanometric spacing can be employed for coupling functional molecules. If used as adapters on sensor chip surfaces, they allow an efficient immobilization of analyte-specific recognition and detector elements such as antibodies and enzymes at highest surface densities. The display on plant viral bionanoparticles may also lead to long-time stabilization of sensor molecules upon repeated uses and has the potential to increase sensor performance substantially, compared to conventional layouts. This has been demonstrated in different proof-of-concept biosensor devices. Therefore, richly available plant viral particles, non-pathogenic for animals or humans, might gain novel importance if applied in receptor layers of FEDs. These perspectives are explained and discussed with regard to future detection strategies for COVID-19 and related viral diseases.}, language = {en} } @article{ElDeibButenwegKlinkel2020, author = {El-Deib, Khaled and Butenweg, Christoph and Klinkel, Sven}, title = {Erdbebennachweis von Mauerwerksbauten mit realistischen Modellen und erh{\"o}hten Verhaltensbeiwerten}, series = {Bautechnik}, volume = {97}, journal = {Bautechnik}, number = {11}, publisher = {Ernst \& Sohn}, address = {Berlin}, doi = {10.1002/bate.202000016}, pages = {756 -- 765}, year = {2020}, abstract = {Die Anwendung des linearen Nachweiskonzepts auf Mauerwerksbauten f{\"u}hrt dazu, dass bereits heute Standsicherheitsnachweise f{\"u}r Geb{\"a}ude mit {\"u}blichen Grundrissen in Gebieten mit moderaten Erdbebeneinwirkungen nicht mehr gef{\"u}hrt werden k{\"o}nnen. Diese Problematik wird sich in Deutschland mit der Einf{\"u}hrung kontinuierlicher probabilistischer Erdbebenkarten weiter versch{\"a}rfen. Aufgrund der Erh{\"o}hung der seismischen Einwirkungen, die sich vielerorts ergibt, ist es erforderlich, die vorhandenen, bislang nicht ber{\"u}cksichtigten Tragf{\"a}higkeitsreserven in nachvollziehbaren Nachweiskonzepten in der Baupraxis verf{\"u}gbar zu machen. Der vorliegende Beitrag stellt ein Konzept f{\"u}r die geb{\"a}udespezifische Ermittlung von erh{\"o}hten Verhaltensbeiwerten vor. Die Verhaltensbeiwerte setzen sich aus drei Anteilen zusammen, mit denen die Lastumverteilung im Grundriss, die Verformungsf{\"a}higkeit und Energiedissipation sowie die {\"U}berfestigkeiten ber{\"u}cksichtigt werden. F{\"u}r die rechnerische Ermittlung dieser drei Anteile wird ein nichtlineares Nachweiskonzept auf Grundlage von Pushover-Analysen vorgeschlagen, in denen die Interaktionen von W{\"a}nden und Geschossdecken durch einen Einspanngrad beschrieben werden. F{\"u}r die Bestimmung der Einspanngrade wird ein nichtlinearer Modellierungsansatz eingef{\"u}hrt, mit dem die Interaktion von W{\"a}nden und Decken abgebildet werden kann. Die Anwendung des Konzepts mit erh{\"o}hten geb{\"a}udespezifischen Verhaltensbeiwerten wird am Beispiel eines Mehrfamilienhauses aus Kalksandsteinen demonstriert. Die Ergebnisse der linearen Nachweise mit erh{\"o}hten Verhaltensbeiwerten f{\"u}r dieses Geb{\"a}ude liegen deutlich n{\"a}her an den Ergebnissen nichtlinearer Nachweise und somit bleiben {\"u}bliche Grundrisse in Erdbebengebieten mit den traditionellen linearen Rechenans{\"a}tzen nachweisbar.}, language = {de} } @article{ButenwegRosin2020, author = {Butenweg, Christoph and Rosin, Julia}, title = {Seismischer Nachweis von Mauerwerksbauten in deutschen Erdbebengebieten}, series = {Mauerwerk}, volume = {24}, journal = {Mauerwerk}, number = {2}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1022}, doi = {10.1002/dama.202000006}, pages = {108 -- 113}, year = {2020}, abstract = {Mit finanzieller Unterst{\"u}tzung der Deutschen Gesellschaft f{\"u}r Mauerwerks- und Wohnungsbau e.V. (DGfM) und des Deutschen Instituts f{\"u}r Bautechnik in Berlin (DIBt) wurden zwei aufeinander aufbauende Forschungsvorhaben zur Verbesserung der seismischen Nachweise von Mauerwerksbauten in deutschen Erdbebengebieten durchgef{\"u}hrt. Zun{\"a}chst wurde das seismische Verhalten von drei modernen unbewehrten Mauerwerksgeb{\"a}uden in der Region Emilia Romagna in Italien w{\"a}hrend der Erdbebenserie im Jahr 2012 in Kooperation mit der Universit{\"a}t Pavia eingehend untersucht. Aufbauend auf den Erkenntnissen dieser Untersuchungen wurde ein verbessertes seismisches Bemessungskonzept f{\"u}r unbewehrte Mauerwerksbauten erarbeitet. Der Beitrag stellt die wesentlichen Ergebnisse dieser Forschungsarbeiten und deren Eingang in die Normung vor.}, language = {de} } @article{MarinkovicButenweg2020, author = {Marinkovic, Marko and Butenweg, Christoph}, title = {Ausfachungen aus Ziegelmauerwerk in Stahlbetonrahmentragwerken unter Erdbebenbeanspruchung}, series = {Mauerwerk}, volume = {24}, journal = {Mauerwerk}, number = {4}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1022}, doi = {10.1002/dama.202000011}, pages = {194 -- 205}, year = {2020}, abstract = {Stahlbetonrahmentragwerke mit Ausfachungen aus Mauerwerk weisen nach Erdbeben h{\"a}ufig schwere Sch{\"a}den auf. Gr{\"u}nde hierf{\"u}r sind die Beanspruchungen der Ausfachungsw{\"a}nde durch die aufgezwungenen Rahmenverformungen in Wandebene und die gleichzeitig auftretenden Tr{\"a}gheitskr{\"a}fte senkrecht zur Wandebene in Kombination mit der konstruktiven Ausf{\"u}hrung des Ausfachungsmauerwerks. Die Ausfachung wird in der Regel knirsch gegen die Rahmenst{\"u}tzen gemauert, wobei der Verschluss der oberen Fuge mit M{\"o}rtel oder Montageschaum erfolgt. Dadurch kommt es im Erdbebenfall zu lokalen Interaktionen zwischen Ausfachung und Rahmen, die in der Folge zu einem Versagen einzelner Ausfachungsw{\"a}nde oder zu einem sukzessiven Versagen des Gesamtgeb{\"a}udes f{\"u}hren k{\"o}nnen. Die beobachteten Sch{\"a}den waren die Motivation daf{\"u}r, in dem europ{\"a}ischen Forschungsprojekt INSYSME f{\"u}r Stahlbetonrahmentragwerke mit Ausfachungen aus hochw{\"a}rmed{\"a}mmenden Ziegelmauerwerk innovative L{\"o}sungen zur Verbesserung des seismischen Verhaltens zu entwickeln. Der vorliegende Beitrag stellt die im Rahmen des Projekts von den deutschen Projektpartnern (Universit{\"a}t Kassel, SDA-engineering GmbH) entwickelten L{\"o}sungen vor und vergleicht deren seismisches Verhalten mit der traditionellen Ausf{\"u}hrung der Ausfachungsw{\"a}nde. Grundlage f{\"u}r den Vergleich sind statisch-zyklische Wandversuche und Simulationen auf Wandebene. Aus den Ergebnissen werden Empfehlungen f{\"u}r die erdbebensichere Auslegung von Stahlbetonrahmentragwerken mit Ausfachungen aus Ziegelmauerwerk abgeleitet.}, language = {de} } @article{MarinkovicButenweg2020, author = {Marinkovic, Marko and Butenweg, Christoph}, title = {Earthquake-proof system for masonry infills in RC frame structures}, series = {International Journal of Masonry Research and Innovation}, volume = {5}, journal = {International Journal of Masonry Research and Innovation}, number = {2}, publisher = {Inderscience Enterprises}, address = {Olney, Bucks}, issn = {2056-9467}, doi = {10.1504/IJMRI.2020.106328}, pages = {185 -- 208}, year = {2020}, language = {de} } @article{MichelButenwegKlinkel2020, author = {Michel, P. and Butenweg, Christoph and Klinkel, S.}, title = {Einfluss der dynamischen Steifigkeit von Flach-und Pfahlgr{\"u}ndungen auf die Dynamik von Onshore-Windenergieanlagen}, series = {Bauingenieur}, volume = {95}, journal = {Bauingenieur}, number = {4}, publisher = {VDI Fachmedien}, address = {D{\"u}sseldorf}, issn = {0005-6650}, pages = {139 -- 146}, year = {2020}, language = {de} } @article{PoghossianSchoening2020, author = {Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Capacitive field-effect eis chemical sensors and biosensors: A status report}, series = {Sensors}, volume = {20}, journal = {Sensors}, number = {19}, publisher = {MDPI}, address = {Basel}, issn = {1424-8220}, doi = {10.3390/s20195639}, pages = {Artikel 5639}, year = {2020}, abstract = {Electrolyte-insulator-semiconductor (EIS) field-effect sensors belong to a new generation of electronic chips for biochemical sensing, enabling a direct electronic readout. The review gives an overview on recent advances and current trends in the research and development of chemical sensors and biosensors based on the capacitive field-effect EIS structure—the simplest field-effect device, which represents a biochemically sensitive capacitor. Fundamental concepts, physicochemical phenomena underlying the transduction mechanism and application of capacitive EIS sensors for the detection of pH, ion concentrations, and enzymatic reactions, as well as the label-free detection of charged molecules (nucleic acids, proteins, and polyelectrolytes) and nanoparticles, are presented and discussed.}, language = {en} } @article{KoppSchunckGosauetal.2020, author = {Kopp, Alexander and Schunck, Laura and Gosau, Martin and Smeets, Ralf and Burg, Simon and Fuest, Sandra and Kr{\"o}ger, Nadja and Zinser, Max and Krohn, Sebastian and Behbahani, Mehdi and K{\"o}pf, Marius and Lauts, Lisa and Rutkowski, Rico}, title = {Influence of the casting concentration on the mechanical and optical properties of Fa/CaCl2-derived silk fibroin membranes}, series = {International Journal of Molecular Sciences}, volume = {21}, journal = {International Journal of Molecular Sciences}, number = {18 art. no. 6704}, publisher = {MDPI}, address = {Basel}, issn = {1422-0067}, doi = {10.3390/ijms21186704}, year = {2020}, abstract = {In this study, we describe the manufacturing and characterization of silk fibroin membranes derived from the silkworm Bombyx mori. To date, the dissolution process used in this study has only been researched to a limited extent, although it entails various potential advantages, such as reduced expenses and the absence of toxic chemicals in comparison to other conventional techniques. Therefore, the aim of this study was to determine the influence of different fibroin concentrations on the process output and resulting membrane properties. Casted membranes were thus characterized with regard to their mechanical, structural and optical assets via tensile testing, SEM, light microscopy and spectrophotometry. Cytotoxicity was evaluated using BrdU, XTT, and LDH assays, followed by live-dead staining. The formic acid (FA) dissolution method was proven to be suitable for the manufacturing of transparent and mechanically stable membranes. The fibroin concentration affects both thickness and transparency of the membranes. The membranes did not exhibit any signs of cytotoxicity. When compared to other current scientific and technical benchmarks, the manufactured membranes displayed promising potential for various biomedical applications. Further research is nevertheless necessary to improve reproducible manufacturing, including a more uniform thickness, less impurity and physiological pH within the membranes.}, language = {en} } @article{FiedlerLaddClemensetal.2020, author = {Fiedler, Thomas M. and Ladd, Mark E. and Clemens, Markus and Bitz, Andreas}, title = {Safety of subjects during radiofrequency exposure in ultra-high-field magnetic resonance imaging}, series = {IEEE Letters on Electromagnetic Compatibility Practice and Applications}, volume = {2}, journal = {IEEE Letters on Electromagnetic Compatibility Practice and Applications}, number = {3}, publisher = {IEEE}, address = {New York, NY}, isbn = {2637-6423}, doi = {10.1109/LEMCPA.2020.3029747}, pages = {1 -- 8}, year = {2020}, abstract = {Magnetic resonance imaging (MRI) is one of the most important medical imaging techniques. Since the introduction of MRI in the mid-1980s, there has been a continuous trend toward higher static magnetic fields to obtain i.a. a higher signal-to-noise ratio. The step toward ultra-high-field (UHF) MRI at 7 Tesla and higher, however, creates several challenges regarding the homogeneity of the spin excitation RF transmit field and the RF exposure of the subject. In UHF MRI systems, the wavelength of the RF field is in the range of the diameter of the human body, which can result in inhomogeneous spin excitation and local SAR hotspots. To optimize the homogeneity in a region of interest, UHF MRI systems use parallel transmit systems with multiple transmit antennas and time-dependent modulation of the RF signal in the individual transmit channels. Furthermore, SAR increases with increasing field strength, while the SAR limits remain unchanged. Two different approaches to generate the RF transmit field in UHF systems using antenna arrays close and remote to the body are investigated in this letter. Achievable imaging performance is evaluated compared to typical clinical RF transmit systems at lower field strength. The evaluation has been performed under consideration of RF exposure based on local SAR and tissue temperature. Furthermore, results for thermal dose as an alternative RF exposure metric are presented.}, language = {en} } @article{MolinnusBegingLowisetal.2020, author = {Molinnus, Denise and Beging, Stefan and Lowis, Carsten and Sch{\"o}ning, Michael Josef}, title = {Towards a multi-enzyme capacitive field-effect biosensor by comparative study of drop-coating and nano-spotting technique}, series = {Sensors}, volume = {20}, journal = {Sensors}, number = {17}, publisher = {MDPI}, address = {Basel}, isbn = {1424-8220}, doi = {10.3390/s20174924}, pages = {Artikel 4942}, year = {2020}, abstract = {Multi-enzyme immobilization onto a capacitive field-effect biosensor by nano-spotting technique is presented. The nano-spotting technique allows to immobilize different enzymes simultaneously on the sensor surface with high spatial resolution without additional photolithographical patterning. The amount of applied enzymatic cocktail on the sensor surface can be tailored. Capacitive electrolyte-insulator-semiconductor (EIS) field-effect sensors with Ta2O5 as pH-sensitive transducer layer have been chosen to immobilize the three different (pL droplets) enzymes penicillinase, urease, and glucose oxidase. Nano-spotting immobilization is compared to conventional drop-coating method by defining different geometrical layouts on the sensor surface (fully, half-, and quarter-spotted). The drop diameter is varying between 84 µm and 102 µm, depending on the number of applied drops (1 to 4) per spot. For multi-analyte detection, penicillinase and urease are simultaneously nano-spotted on the EIS sensor. Sensor characterization was performed by C/V (capacitance/voltage) and ConCap (constant capacitance) measurements. Average penicillin, glucose, and urea sensitivities for the spotted enzymes were 81.7 mV/dec, 40.5 mV/dec, and 68.9 mV/dec, respectively.}, language = {en} }