@inproceedings{KernDikta2009, author = {Kern, Alexander and Dikta, Gerhard}, title = {Probability of damage of electrical and electronic systems due to indirect lightning flashes - investigation of data from German insurance companies}, year = {2009}, abstract = {In the presented paper data collected from the field related to damage statistics of electrical and electronic apparatus in household are reported and investigated. These damages (total number approx. 74000 cases), registered by five German insurance companies in 2005 and 2006, were adviced by customers as caused by lightning overvoltages. With the use of stochastical methods it is possible, to reasses the collected data and to distinguish between cases, which are with high probability caused by lightning overvoltages, and those, which are not. If there was an indication for a direct strike, this case was excluded, so the focus was only on indirect lightning flashes, i.e. only flashes to ground near the structure and flashes to or nearby an incoming service line were investigated. The data from the field contain the location of damaged apparatus (residence of the policy holder) and the distances of the nearest cloud-to-ground stroke to the location of the damage registered by the German lightning location network BLIDS at the date of damage. The statistical data along with some complementary numerical simulations allow to verify the correspondence of the Standards rules used for IEC 62305-2 with the field data and to define some correction needs. The results could lead to a better understanding whether a damage reported to an insurance company is really caused by indirect lightning, or not.}, subject = {Blitzschutz}, language = {en} } @misc{Kaster2009, author = {Kaster, Jan Mathis}, title = {Untersuchungen zur Specklereduktion bei der Infrarot-Laser gest{\"u}tzten Ferndetektion von TNT-Oberfl{\"a}chenkontaminationen}, year = {2009}, abstract = {Das Ziel der vorliegenden Arbeit ist die Specklereduktion bei der Infrarotlaser-gest{\"u}tzten abbildenden Ferndetektion von TNT-Oberfl{\"a}chenkontaminationen. F{\"u}r die Detektion wird die Probenoberfl{\"a}che mit einem abstimmbaren Quantenkaskadenlaser bei verschiedenen Wellenzahlen im Spektralbereich von 1340cm-1 bis 1380cm-1 bestrahlt, w{\"a}hrend eine Infrarot-Kamera Bilder der bestrahlten Fl{\"a}che aufzeichnet. Diese Bilder werden dann so verarbeitet, dass im Ausgabebild die chemisch spezifische TNT-Absorption durch eine {\"A}nderung der Helligkeit {\"o}rtlich aufgel{\"o}st erkennbar werden. Da koh{\"a}rente Strahlung, welche beispielsweise an optisch rauen Oberfl{\"a}chen reflektiert wird, aufgrund der stochastischen Verteilung der Oberfl{\"a}chenrautiefe mit der einfallenden Strahlung lateral unterschiedlich interferiert, entsteht ein „Rauschen" in der aufgezeichneten Strahlungsleistungsverteilung, das sog. Speckle-Ph{\"a}nomen. Die Empfindlichkeit der oben skizzierten Lasergest{\"u}tzten Messtechnik wird im Wesentlichen durch diesen Effekt limitiert. Um die durch Laserspeckles verursachten Rauschanteile zu reduzieren, gibt es verschiedene M{\"o}glichkeiten. Durch Reduktion von zeitlicher und r{\"a}umlicher Koh{\"a}renz der Strahlung wird deren Interferenzf{\"a}higkeit reduziert und durch Variieren des Specklemusters w{\"a}hrend einer Bildaufzeichnung f{\"u}hren Mittelungen unkorrelierter Rauschanteile zu einer Specklekontrastreduktion. Letztere M{\"o}glichkeit resultiert daraus, dass Laserspeckles statistisch durch die Familie der Gammaverteilungen beschrieben werden k{\"o}nnen. Demnach verbessert sich das Signal-zu-Rausch-Verh{\"a}ltnis mit der Anzahl gemittelter, unkorrelierter Rauschmuster proportional zur Wurzel dieser Anzahl. Ein im MIR-Spektralbereich umsetzbarer Ansatz, der all diese M{\"o}glichkeiten ber{\"u}cksichtigt, wurde bereits 1971 von Lowenthal und Joyeaux vorgeschlagen und im Rahmen der vorliegenden Arbeit f{\"u}r den infraroten Spektralbereich adaptiert. Dazu wird die Strahlung mit zwei CVD-Diamant-Wafern moduliert; ein Wafer ist dabei station{\"a}r und der andere rotiert mit ca. 70Hz. In der vorliegenden Arbeit konnte mit diesem Ansatz eine Verbesserung des Signal-zu-Rausch-Verh{\"a}ltnisses in der betrachteten Strahlungsleistungs¬verteilung von urspr{\"u}nglich 3 auf etwa 45 erzielt werden. So konnten erstmals TNT-Kontaminationen von bis zu 10µg/cm² in einem Abstand von 5m abbildend nachgewiesen werden. Dies entspricht der Kontamination durch einen mit TNT leicht verunreinigten Fingerabdruck.}, subject = {Speckle}, language = {de} } @article{WettingfeldKernKraemeretal.2009, author = {Wettingfeld, J{\"u}rgen and Kern, Alexander and Kr{\"a}mer, Heinz-Josef and Thorm{\"a}hlen, Reyno}, title = {International anerkannte Blitzschutznormen : Ausgewogener und sicherer Schutz}, publisher = {Fachhochschule Aachen}, address = {Aachen}, year = {2009}, abstract = {Die Einleitung zur Norm DIN EN 62305-3 beschreibt klar und ein - deutig: Der vorliegende Teil der IEC 62305 behandelt den Schutz von baulichen Anlagen gegen materielle Sch{\"a}den und den Schutz von Personen gegen Verletzungen durch Ber{\"u}hrungs- und Schrittspannungen. Als das wesentlichste und effektivste Mittel zum Schutz von baulichen Anlagen gegen materielle Sch{\"a}den gilt das Blitz - schutzsystem (LPS).}, subject = {Blitzschutz}, language = {de} } @inproceedings{KernBeierlZischank2009, author = {Kern, Alexander and Beierl, Ottmar and Zischank, Wolfgang}, title = {Calculation of the separation distance according to IEC 62305-3: 2006-10 - Remarks for the application and simplified methods}, year = {2009}, abstract = {[Paper of the X International Symposium on Lightning Protection 9th - 13th November, 2009 - Curitiba, Brazil. 6 pages] The international standard IEC 62305-3, published in 2006, requires as an integral part of the lightning protection system (LPS) the consideration of a separation distance between the conductors of the LPS and metal and electrical installations inside the structure to be protected. IEC 62305-3 gives two different methods for this calculation: a standard, simplified approach and a more detailed approach, which differ especially regarding the treatment of the current sharing effect on the LPS conductors. Hence, different results for the separation distance are possible, leading to some discrepancies in the use of the standard. The standard approach defined in the main part (Clause 6.3) and in Annex C of the standard in some cases may lead to a severe oversizing of the required separation distance. The detailed approach described in Annex E naturally gives more correct results. However, a calculation of the current sharing amongst all parts of the air-termination and downconductor network is necessary, in many cases requiring the use of network analysis programs. In this paper simplified methods for the assessment of the current sharing are presented, which are easy to use as well as sufficiently adequate.}, subject = {Blitzschutz}, language = {de} } @inproceedings{BehrensFrentzelKern2009, author = {Behrens, J{\"o}rg and Frentzel, Ralf and Kern, Alexander}, title = {Simulation der transienten Spannungsverl{\"a}ufe im Eigenbedarfsnetz eines Großkraftwerks bei einem kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung}, isbn = {978-3-8007-3197-8}, year = {2009}, abstract = {8. VDE/ABB-Blitzschutztagung, 29. - 30. Oktober 2009 in Neu-Ulm. Blitzschutztagung <8, 2009, Neu-Ulm> Berlin : VDE Verl. 2009 Großkraftwerke k{\"o}nnen durch Blitzentladungen mit potentiellen Auswirkungen auf deren Verf{\"u}gbarkeit und Sicherheit gef{\"a}hrdet werden. Ein sehr spezielles Szenario, welches aus aktuellem Anlass zu untersuchen war, betrifft den kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung am Netzanschluss der Anlage. Wird nun noch ein sogenannter Schirmfehler unterstellt, d.h. der direkte Blitzeinschlag erfolgt in ein Leiterseil des Hoch- bzw. H{\"o}chstspannungsnetzes und nicht in das dar{\"u}ber gespannte Erdseil, so bedeutet dies eine extreme elektromagnetische Einwirkung. Der vorliegende Beitrag befasst sich mit der Simulation eines solchen Blitzeinschlages und dessen Auswirkungen auf den Netzanschluss und die Komponenten der elektrischen Eigenbedarfsanlagen eines Kraftwerks auf den unterlagerten Spannungsebenen. Die dabei gewonnenen Erkenntnisse lassen sich ohne Einschr{\"a}nkungen auf Industrieanlagen mit Mittelspannungs-Netzanschluss und ohne eigener Stromversorgung {\"u}bertragen.}, subject = {Blitzschutz}, language = {de} } @article{KernKloetersPferdmenges2009, author = {Kern, Alexander and Kl{\"o}ters, Georg and Pferdmenges, J{\"o}rg}, title = {Blitzschutzoptimierung in der LST an nicht-elektrifizierten Strecken}, series = {Signal und Draht. 101 (2009), H. 4}, journal = {Signal und Draht. 101 (2009), H. 4}, publisher = {DVV Media Group}, address = {Hamburg}, isbn = {0037-4997}, pages = {17 -- 21}, year = {2009}, language = {de} } @article{KernBeierlZischank2009, author = {Kern, Alexander and Beierl, O. and Zischank, W.}, title = {DIN EN 62 305-3 - Berechnung des Trennungsabstands (Anmerkungen zur Anwendung der Berechnungsverfahren und vereinfachte Verfahren zur Absch{\"a}tzung der Stromaufteilung) / Kern, A. ; Beierl, O. ; Zischank, W.}, series = {Elektropraktiker. 63 (2009), H. 3}, journal = {Elektropraktiker. 63 (2009), H. 3}, publisher = {HUSS-MEDIEN GmbH}, address = {Berlin}, isbn = {0013-5569}, pages = {218 -- 222}, year = {2009}, language = {de} } @article{Kern2009, author = {Kern, Alexander}, title = {{\"U}berarbeitung der Blitzschutznorm IEC 62305}, series = {Elektropraktiker. 63 (2009), H. 4}, journal = {Elektropraktiker. 63 (2009), H. 4}, isbn = {0013-5569}, pages = {391 -- 394}, year = {2009}, language = {de} } @article{SchwarzerdaSilvaHoffschmidtetal.2009, author = {Schwarzer, Klemens and da Silva, Vieira E. and Hoffschmidt, Bernhard and Schwarzer, T.}, title = {A new solar desalination system with heat recovery for decentralised drinking water production}, series = {Desalination. 248 (2009), H. 1-3}, journal = {Desalination. 248 (2009), H. 1-3}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {0011-9164}, pages = {204 -- 211}, year = {2009}, language = {en} } @book{Dielmann2009, author = {Dielmann, Klaus-Peter}, title = {Integration des CROWN-Systems in die Biogasgewinnung [Elektronische Ressource] : Abschlussbericht / K. Dielmann}, publisher = {FH Aachen, Fachbereich 10 NOWUM-Energy}, address = {J{\"u}lich}, pages = {Online Ressource (68 S., 3,20 MB) : Ill., graph. D}, year = {2009}, language = {de} }