@inproceedings{FingerGoettenBraunetal.2019, author = {Finger, Felix and G{\"o}tten, Falk and Braun, Carsten and Bil, C.}, title = {On Aircraft Design Under the Consideration of Hybrid-Electric Propulsion Systems}, series = {APISAT 2018: The Proceedings of the 2018 Asia-Pacific International Symposium on Aerospace Technology (APISAT 2018)}, booktitle = {APISAT 2018: The Proceedings of the 2018 Asia-Pacific International Symposium on Aerospace Technology (APISAT 2018)}, publisher = {Springer}, address = {Singapore}, isbn = {978-981-13-3305-7}, doi = {10.1007/978-981-13-3305-7_99}, pages = {1261 -- 1272}, year = {2019}, abstract = {A hybrid-electric propulsion system combines the advantages of fuel-based systems and battery powered systems and offers new design freedom. To take full advantage of this technology, aircraft designers must be aware of its key differences, compared to conventional, carbon-fuel based, propulsion systems. This paper gives an overview of the challenges and potential benefits associated with the design of aircraft that use hybrid-electric propulsion systems. It offers an introduction of the most popular hybrid-electric propulsion architectures and critically assess them against the conventional and fully electric propulsion configurations. The effects on operational aspects and design aspects are covered. Special consideration is given to the application of hybrid-electric propulsion technology to both unmanned and vertical take-off and landing aircraft. The authors conclude that electric propulsion technology has the potential to revolutionize aircraft design. However, new and innovative methods must be researched, to realize the full benefit of the technology.}, language = {en} } @inproceedings{LuftGebhardtBalc2019, author = {Luft, Angela and Gebhardt, Andreas and Balc, Nicolae}, title = {Challenges of additive manufacturing in production systems}, series = {Modern technologies in manufacturing (MTeM 2019)}, volume = {299}, booktitle = {Modern technologies in manufacturing (MTeM 2019)}, number = {Article 01003}, doi = {10.1051/matecconf/201929901003}, pages = {6 Seiten}, year = {2019}, language = {en} } @inproceedings{BungOertel2019, author = {Bung, Daniel Bernhard and Oertel, Mario}, title = {Wave breaking over a submerged horizontal plate: Optical Flow, LES and RANS}, series = {E-proceedings of the 38th IAHR World Congress September 1-6, 2019, Panama City, Panama}, booktitle = {E-proceedings of the 38th IAHR World Congress September 1-6, 2019, Panama City, Panama}, doi = {10.3850/38WC092019-0509}, pages = {3690 -- 3698}, year = {2019}, language = {en} } @inproceedings{HunkerJungGossmannetal.2019, author = {Hunker, Jan and Jung, Alexander and Goßmann, Matthias and Linder, Peter and Staat, Manfred}, title = {Development of a tool to analyze the conduction speed in microelectrode array measurements of cardiac tissue}, series = {3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen}, booktitle = {3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen}, editor = {Staat, Manfred and Erni, Daniel}, publisher = {Universit{\"a}t Duisburg-Essen}, address = {Duisburg}, organization = {MedTech Symposium}, isbn = {978-3-940402-22-6}, doi = {10.17185/duepublico/48750}, pages = {7 -- 8}, year = {2019}, abstract = {The discovery of human induced pluripotent stem cells reprogrammed from somatic cells [1] and their ability to differentiate into cardiomyocytes (hiPSC-CMs) has provided a robust platform for drug screening [2]. Drug screenings are essential in the development of new components, particularly for evaluating the potential of drugs to induce life-threatening pro-arrhythmias. Between 1988 and 2009, 14 drugs have been removed from the market for this reason [3]. The microelectrode array (MEA) technique is a robust tool for drug screening as it detects the field potentials (FPs) for the entire cell culture. Furthermore, the propagation of the field potential can be examined on an electrode basis. To analyze MEA measurements in detail, we have developed an open-source tool.}, language = {en} } @inproceedings{AzarDigel2019, author = {Azar, Fouad and Digel, Ilya}, title = {Utilization of fluorescence spectroscopy and neural networks in clinical analysis}, series = {3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen}, booktitle = {3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen}, editor = {Staat, Manfred and Erni, Daniel}, publisher = {Universit{\"a}t Duisburg-Essen}, address = {Duisburg}, organization = {MedTech Symposium}, isbn = {978-3-940402-22-6}, doi = {10.17185/duepublico/48750}, pages = {40 -- 41}, year = {2019}, abstract = {Fluorescence topography of human urine in combination with learning algorithms can provide a variant pattern recognition method in analytical clinical chemistry and, eventually, diagnosis.}, language = {en} } @inproceedings{RamanJungHorvathetal.2019, author = {Raman, Aravind Hariharan and Jung, Alexander and Horv{\´a}th, Andr{\´a}s and Becker, Nadine and Staat, Manfred}, title = {Modification of a computer model of human stem cell-derived cardiomyocyte electrophysiology based on Patch-Clamp measurements}, series = {3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen}, booktitle = {3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen}, editor = {Staat, Manfred and Erni, Daniel}, publisher = {Universit{\"a}t Duisburg-Essen}, address = {Duisburg}, organization = {MedTech Symposium}, isbn = {978-3-940402-22-6}, doi = {10.17185/duepublico/48750}, pages = {10 -- 11}, year = {2019}, abstract = {Human induced pluripotent stem cells (hiPSCs) have shown to be promising in disease studies and drug screenings [1]. Cardiomyocytes derived from hiPSCs have been extensively investigated using patch-clamping and optical methods to compare their electromechanical behaviour relative to fully matured adult cells. Mathematical models can be used for translating findings on hiPSCCMs to adult cells [2] or to better understand the mechanisms of various ion channels when a drug is applied [3,4]. Paci et al. (2013) [3] developed the first model of hiPSC-CMs, which they later refined based on new data [3]. The model is based on iCells® (Fujifilm Cellular Dynamics, Inc. (FCDI), Madison WI, USA) but major differences among several cell lines and even within a single cell line have been found and motivate an approach for creating sample-specific models. We have developed an optimisation algorithm that parameterises the conductances (in S/F=Siemens/Farad) of the latest Paci et al. model (2018) [5] using current-voltage data obtained in individual patch-clamp experiments derived from an automated patch clamp system (Patchliner, Nanion Technologies GmbH, Munich).}, language = {en} } @inproceedings{BayerHeschelerArtmannetal.2019, author = {Bayer, Robin and Hescheler, J{\"u}rgen and Artmann, Gerhard and Temiz Artmann, Ayseg{\"u}l}, title = {Treating arterial hypertension in a cell culture well}, series = {3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH AachenW}, booktitle = {3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH AachenW}, editor = {Staat, Manfred and Erni, Daniel}, publisher = {Universit{\"a}t Duisburg-Essen}, address = {Duisburg}, organization = {MedTech Symposium}, isbn = {978-3-940402-22-6}, doi = {10.17185/duepublico/48750}, pages = {5 -- 6}, year = {2019}, abstract = {Hypertension describes the pathological increase of blood pressure, which is most commonly associated with the increase of vascular wall stiffness [1]. Referring to the "Deutsche Bluthochdruck Liga" this pathology shows a growing trend in our aging society. In order to find novel pharmacological and probably personalized treatments, we want to present a functional approach to study biomechanical properties of a human aortic vascular model. In this method review we will give an overview of recent studies which were carried out with the CellDrum technology [2] and underline the added value to already existing standard procedures known from the field of physiology. Herein described CellDrum technology is a system to measure functional mechanical properties of cell monolayers and thin tissue constructs in-vitro. Additionally, the CellDrum enables to elucidate the mechanical response of cells to pharmacological drugs, toxins and vasoactive agents. Due to its highly flexible polymer support, cells can also be mechanically stimulated by steady and cyclic biaxial stretching.}, language = {en} } @inproceedings{BlumAlbannaBenninghausetal.2019, author = {Blum, Yannik and Albanna, Walid and Benninghaus, Anne and Kotliar, Konstantin}, title = {Vasomotion in retinal vessels of patients presenting post hemorrhagic hydrocephalus following subarachnoid hemorrhage}, series = {3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen}, booktitle = {3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen}, editor = {Staat, Manfred and Erni, Daniel}, publisher = {Universit{\"a}t Duisburg-Essen}, address = {Duisburg}, organization = {MedTech Symposium}, isbn = {978-3-940402-22-6}, doi = {10.17185/duepublico/48750}, pages = {38 -- 39}, year = {2019}, abstract = {Clearance of blood components and fluid drainage play a crucial role in subarachnoid hemorrhage (SAH) and post hemorrhagic hydrocephalus (PHH). With the involvement of interstitial fluid (ISF) and cerebrospinal fluid (CSF), two pathways for the clearance of fluid and solutes in the brain are proposed. Starting at the level of capillaries, flow of ISF follows along the basement membranes in the walls of cerebral arteries out of the parenchyma to drain into the lymphatics and CSF [1]-[3]. Conversely, it is shown that CSF enters the parenchyma between glial and pial basement membranes of penetrating arteries [4]-[6]. Nevertheless, the involved structures and the contribution of either flow pathway to fluid balance between the subarachnoid space and interstitial space remains controversial. Low frequency oscillations in vascular tone are referred to as vasomotion and corresponding vasomotion waves are modeled as the driving force for flow of ISF out of the parenchyma [7]. Retinal vessel analysis (RVA) allows non-invasive measurement of retinal vessel vasomotion with respect to diameter changes [8]. Thus, the aim of the study is to investigate vasomotion in RVA signals of SAH and PHH patients.}, language = {en} } @inproceedings{SadeghfamSadeghiAhangarElgamaletal.2019, author = {Sadeghfam, Arash and Sadeghi-Ahangar, A. and Elgamal, Abdelrahman and Heuermann, Holger}, title = {Design and Development of a Novel Self-Igniting Microwave Plasma Jet for Industrial Applications}, series = {IEEE MTT-S International Microwave Symposium Digest}, booktitle = {IEEE MTT-S International Microwave Symposium Digest}, isbn = {978-172811309-8}, pages = {63 -- 66}, year = {2019}, language = {en} } @inproceedings{BeckerWolf2019, author = {Becker, Willi and Wolf, Martin R.}, title = {Entwicklung eines Einf{\"u}hrungskonzepts f{\"u}r IT-Service-Management in KMU}, series = {Angewandte Forschung in der Wirtschaftsinformatik 2019 : Tagungsband zur 32. AKWI-Jahrestagung / hrsg. von Martin R. Wolf, Thomas Barton, Frank Herrmann, Vera G. Meister, Christian M{\"u}ller, Christian Seel}, booktitle = {Angewandte Forschung in der Wirtschaftsinformatik 2019 : Tagungsband zur 32. AKWI-Jahrestagung / hrsg. von Martin R. Wolf, Thomas Barton, Frank Herrmann, Vera G. Meister, Christian M{\"u}ller, Christian Seel}, publisher = {mana-Buch}, address = {Heide}, isbn = {978-3-944330-62-4}, pages = {129 -- 137}, year = {2019}, abstract = {Obwohl es eine Vielzahl von Einf{\"u}hrungskonzepten f{\"u}r ITSM gibt, hat sich bisher keines dieser Konzepte auf breiter Linie durchgesetzt. Das gilt in erh{\"o}htem Maße f{\"u}r ITSM-Einf{\"u}hrungskonzepte f{\"u}r KMU, wohl nicht zuletzt aufgrund der Tatsache, dass der Mehrwert von ITSM f{\"u}r KMU aufgrund der geringeren Gr{\"o}ße der IT-Organisationen nur entsprechend schwieriger generiert werden kann. Mit diesem Beitrag wird ein Einf{\"u}hrungskonzept f{\"u}r ITSM in KMU systematisch hergeleitet. Daf{\"u}r wurden zun{\"a}chst die Treiber und Barrieren von ITSM untersucht, um daraus ein umfassendes Wirkmodell zu entwickeln. Da mit diesem Wirkungsmodell die Einflussfaktoren auf den Erfolg von ITSM in KMU deutlich werden, konnte auf dieser Basis ein Einf{\"u}hrungskonzept abgeleitet werden, welches insbesondere die positiven Effekte unterst{\"u}tzt bzw. verst{\"a}rkt.}, language = {de} }