@article{LevesqueSaurerSiegwolfetal.2013, author = {L{\´e}vesque, Mathieu and Saurer, Matthias and Siegwolf, Rolf and Eilmann, Britta and Brang, Peter and Bugmann, Harald and Rigling, Andreas}, title = {Drought response of five conifer species under contrasting water availability suggests high vulnerability of Norway spruce and European larch}, series = {Global Change Biology}, volume = {19}, journal = {Global Change Biology}, number = {10}, publisher = {Wiley-Blackwell}, address = {Oxford}, issn = {1365-2486 (Online)}, doi = {10.1111/gcb.12268}, pages = {3184 -- 3199}, year = {2013}, language = {en} } @article{GraesslRenzHezeletal.2013, author = {Gr{\"a}ßl, Andreas and Renz, Wolfgang and Hezel, Fabian and Dieringer, Matthias A. and Winter, Lukas and {\"O}zerdem, Celal and Rieger, Jan and Kellmann, Peter and Santoro, Davide and Lindel, Tomasz D. and Frauenrath, Tobias and Pfeiffer, Harald and Niendorf, Thoralf}, title = {Modular 32-channel transceiver coil array for cardiac MRI at 7.0T}, series = {Magnetic Resonance in Medicine}, volume = {72}, journal = {Magnetic Resonance in Medicine}, number = {1}, publisher = {Wiley-Liss}, address = {New York}, issn = {1522-2594}, doi = {10.1002/mrm.24903}, pages = {276 -- 290}, year = {2013}, abstract = {Purpose To design and evaluate a modular transceiver coil array with 32 independent channels for cardiac MRI at 7.0T. Methods The modular coil array comprises eight independent building blocks, each containing four transceiver loop elements. Numerical simulations were used for B1+ field homogenization and radiofrequency (RF) safety validation. RF characteristics were examined in a phantom study. The array's suitability for accelerated high spatial resolution two-dimensional (2D) FLASH CINE imaging of the heart was examined in a volunteer study. Results Transmission field adjustments and RF characteristics were found to be suitable for the volunteer study. The signal-to-noise intrinsic to 7.0T together with the coil performance afforded a spatial resolution of 1.1 × 1.1 × 2.5 mm3 for 2D CINE FLASH MRI, which is by a factor of 6 superior to standardized CINE protocols used in clinical practice at 1.5T. The 32-channel transceiver array supports one-dimensional acceleration factors of up to R = 4 without impairing image quality significantly. Conclusion The modular 32-channel transceiver cardiac array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0T.}, language = {en} } @article{EilmanndeVriesdenOudenetal.2013, author = {Eilmann, Britta and de Vries, Sven M. G. and den Ouden, Jan and Mohren, Godefridus M. J. and Sauren, Pascal and Sass-Klaassen, Ute G. W.}, title = {Origin matters! Difference in drought tolerance and productivity of coastal Douglas-fir (Pseudotsuga menziesii (Mirb.)) provenances}, series = {Forest Ecology and Management}, volume = {2013}, journal = {Forest Ecology and Management}, number = {302}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1872-7042 (Online)}, doi = {doi:10.1016/j.foreco.2013.03.031}, pages = {133 -- 143}, year = {2013}, language = {en} } @inproceedings{NoetzoldUphuesWegeneretal.2013, author = {N{\"o}tzold, K. and Uphues, A. and Wegener, R. and Fink, K. and Bragard, Michael and Griessel, R. and Soter, S.}, title = {Inverter based test setup for LVRT verification of a full-scale 2 MW wind power converter}, series = {15th European Conference on Power Electronics and Applications (EPE), 2013 : 2 - 6 Sept. 2013, Lille, France / [EPE Association; PELS, IEEE Power Electronics Society]}, booktitle = {15th European Conference on Power Electronics and Applications (EPE), 2013 : 2 - 6 Sept. 2013, Lille, France / [EPE Association; PELS, IEEE Power Electronics Society]}, publisher = {IEEE}, address = {Piscataway, NJ}, isbn = {978-1-4799-0115-9 (Online-Ausg.)}, doi = {10.1109/EPE.2013.6634752}, pages = {1037 -- 1042}, year = {2013}, language = {en} } @article{WegnervonArxSassKlaassenetal.2013, author = {Wegner, Lena and von Arx, Georg and Sass-Klaassen, Ute G. W. and Eilmann, Britta}, title = {ROXAS - an efficient and accurate tool to detect vessels in diffuse-porous species}, series = {IAWA Journal / International Association of Wood Anatomists}, volume = {34}, journal = {IAWA Journal / International Association of Wood Anatomists}, number = {4}, publisher = {Brill}, address = {Leiden}, issn = {0928-1541 (Print)}, doi = {10.1163/22941932-00000034}, pages = {425 -- 432}, year = {2013}, language = {en} } @incollection{Fabo2013, author = {Fabo, Sabine}, title = {Portrait of the artist as a spoilsport : Marcel Odenbach's concept of detachment}, series = {Take it or leave it : Marcel Odenbach - anthology of texts and videos. - (eva - edition video art ; 2)}, booktitle = {Take it or leave it : Marcel Odenbach - anthology of texts and videos. - (eva - edition video art ; 2)}, editor = {Kacunko, Slavko}, publisher = {Logos}, address = {Berlin}, isbn = {978-3-8325-3386-1}, pages = {11 -- 29}, year = {2013}, language = {en} } @article{PoghossianWeilCherstvyetal.2013, author = {Poghossian, Arshak and Weil, M. and Cherstvy, A. G. and Sch{\"o}ning, Michael Josef}, title = {Electrical monitoring of polyelectrolyte multilayer formation by means of capacitive field-effect devices}, series = {Analytical and bioanalytical chemistry}, volume = {405}, journal = {Analytical and bioanalytical chemistry}, number = {20}, publisher = {Springer}, address = {Berlin}, issn = {1432-1130 ; 1618-2642}, doi = {10.1007/s00216-013-6951-9}, pages = {6425 -- 6436}, year = {2013}, abstract = {The semiconductor field-effect platform represents a powerful tool for detecting the adsorption and binding of charged macromolecules with direct electrical readout. In this work, a capacitive electrolyte-insulator-semiconductor (EIS) field-effect sensor consisting of an Al-p-Si-SiO2 structure has been applied for real-time in situ electrical monitoring of the layer-by-layer formation of polyelectrolyte (PE) multilayers (PEM). The PEMs were deposited directly onto the SiO2 surface without any precursor layer or drying procedures. Anionic poly(sodium 4-styrene sulfonate) and cationic weak polyelectrolyte poly(allylamine hydrochloride) have been chosen as a model system. The effect of the ionic strength of the solution, polyelectrolyte concentration, number and polarity of the PE layers on the characteristics of the PEM-modified EIS sensors have been studied by means of capacitance-voltage and constant-capacitance methods. In addition, the thickness, surface morphology, roughness and wettabilityof the PE mono- and multilayers have been characterised by ellipsometry, atomic force microscopy and water contact-angle methods, respectively. To explain potential oscillations on the gate surface and signal behaviour of the capacitive field-effect EIS sensor modified with a PEM, a simplified electrostatic model that takes into account the reduced electrostatic screening of PE charges by mobile ions within the PEM has been proposed and discussed.}, language = {en} } @inproceedings{NiemuellerLakemeyerFerrein2013, author = {Niem{\"u}ller, Tim and Lakemeyer, Gerhard and Ferrein, Alexander}, title = {Aspects of integrating diverse software into robotic systems extended abstract}, series = {ICRA 2013 - 8th Workshop on Software Development and Integration in Robotics (SDIR), Karlsruhe, Germany}, booktitle = {ICRA 2013 - 8th Workshop on Software Development and Integration in Robotics (SDIR), Karlsruhe, Germany}, pages = {1 -- 2}, year = {2013}, language = {en} } @article{KramerHalamkovaPoghossianetal.2013, author = {Kramer, Friederike and Halamkova, Lenka and Poghossian, Arshak and Sch{\"o}ning, Michael Josef and Katz, Evgeny and Halamek, Jan}, title = {Biocatalytic analysis of biomarkers for forensic identification of ethnicity between Caucasian and African American}, series = {The analyst. August 2013}, volume = {Vol. 138}, journal = {The analyst. August 2013}, publisher = {Royal Society of Chemistry}, address = {Cambridge}, issn = {1364-5528 (E-Journal); 0003-2654 (Print)}, pages = {6251 -- 6257}, year = {2013}, language = {en} } @article{BaeckerRakowskiPoghossianetal.2013, author = {B{\"a}cker, Matthias and Rakowski, D. and Poghossian, Arshak and Biselli, Manfred and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Chip-based amperometric enzyme sensor system for monitoring of bioprocesses by flow-injection analysis}, series = {Journal of Biotechnology}, volume = {163}, journal = {Journal of Biotechnology}, number = {4}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0168-1656}, doi = {10.1016/j.jbiotec.2012.03.014}, pages = {371 -- 376}, year = {2013}, abstract = {A microfluidic chip integrating amperometric enzyme sensors for the detection of glucose, glutamate and glutamine in cell-culture fermentation processes has been developed. The enzymes glucose oxidase, glutamate oxidase and glutaminase were immobilized by means of cross-linking with glutaraldehyde on platinum thin-film electrodes integrated within a microfluidic channel. The biosensor chip was coupled to a flow-injection analysis system for electrochemical characterization of the sensors. The sensors have been characterized in terms of sensitivity, linear working range and detection limit. The sensitivity evaluated from the respective peak areas was 1.47, 3.68 and 0.28 μAs/mM for the glucose, glutamate and glutamine sensor, respectively. The calibration curves were linear up to a concentration of 20 mM glucose and glutamine and up to 10 mM for glutamate. The lower detection limit amounted to be 0.05 mM for the glucose and glutamate sensor, respectively, and 0.1 mM for the glutamine sensor. Experiments in cell-culture medium have demonstrated a good correlation between the glutamate, glutamine and glucose concentrations measured with the chip-based biosensors in a differential-mode and the commercially available instrumentation. The obtained results demonstrate the feasibility of the realized microfluidic biosensor chip for monitoring of bioprocesses.}, language = {en} }