@article{WagnerWernerMiyamotoetal.2012, author = {Wagner, Torsten and Werner, Frederik and Miyamoto, Ko-Ichiro and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Development and characterisation of a compact light-addressable potentiometric sensor (LAPS) based on the digital light processing (DLP) technology for flexible chemical imaging}, series = {Sensors and Actuators B: Chemical}, volume = {170}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2010.12.003}, pages = {34 -- 39}, year = {2012}, abstract = {Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach to read out light-addressable potentiometric sensors (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device, which allows fast and flexible generation of light patterns. With the help of these light patterns, the sensor surface of the LAPS device can be addressed. The DLP approach has several advantages compared to conventional LAPS set-ups, e.g., the spot size and the shape of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of the measurement. In addition, the modulation frequency and intensity of the light beam are important parameters of the LAPS set-up. Within this work, the authors will discuss two different ways of light modulation by the DLP set-up, investigate the influence of different modulation frequencies and different light intensities as well as demonstrate the scanning capabilities of the new set-up by pH mapping on the sensor surface.}, language = {en} } @incollection{Vismann2012, author = {Vismann, Ulrich}, title = {Stahlbeton- und Spannbetonbau nach Eurocode 2}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_12}, pages = {601 -- 775}, year = {2012}, abstract = {Die bauaufsichtliche Einf{\"u}hrung der Eurocodes steht unmittelbar bevor. F{\"u}r den Bereich des Stahl- und Spannbetonbaus soll die Anwendung zum 1. Juli 2012 verbindlich sein, d. h. mit diesem Stichtag sollte nur noch der Eurocode 2 (DIN EN 1992-1-1, Ausgabe Januar 2011) mit seinem zugeh{\"o}rigen nationalen Anhang (DIN EN 1992-1-1/NA, Ausgabe Januar 2011) Verwendung finden, die DIN 1045-1 wird zur{\"u}ckgezogen. Bereits seit M{\"a}rz 2010 gilt eine {\"U}bergangsphase, ist der die Anwendung des Eurocodes alternativ zur DIN 1045-1 als bauaufsichtlich gleichwertige L{\"o}sung m{\"o}glich.}, language = {de} } @incollection{Vismann2012, author = {Vismann, Ulrich}, title = {Beton nach DIN 1045-2}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_11}, pages = {571 -- 600}, year = {2012}, language = {de} } @incollection{Feiser2012, author = {Feiser, Johannes}, title = {Geotechnik}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_17}, pages = {1221 -- 1332}, year = {2012}, abstract = {In der nationalen und der europ{\"a}ischen Normung werden die geotechnischen Aufgaben zwecks Mindestanforderungen an Baugrunduntersuchung, rechnerische Nachweise und {\"U}berwachung der Ausf{\"u}hrung in drei Klassen (Kategorien) eingeteilt. Sie richten sich nach der zu erwartenden Reaktion des Baugrundes, nach dem geotechnischen Schwierigkeitsgrad des Tragwerks und seiner Einfl{\"u}sse auf dieUmgebung.}, language = {de} } @incollection{Strohmeier2012, author = {Strohmeier, Andreas}, title = {Siedlungswasserwirtschaft}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_19}, pages = {1393 -- 1498}, year = {2012}, language = {de} } @incollection{Biener2012, author = {Biener, Ernst}, title = {Abfallwirtschaft}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_20}, pages = {1499 -- 1540}, year = {2012}, language = {de} } @incollection{LohseStroetmann2012, author = {Lohse, Wolfram and Stroetmann, Richard}, title = {Stahlbau}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_13}, pages = {777 -- 1019}, year = {2012}, language = {de} } @article{AggarwalDhimanKumaretal.2012, author = {Aggarwal, P. and Dhiman, S. and Kumar, G. and Scherer, Ulrich W. and Singla, M. L. and Srivastava, A.}, title = {Optical study of poly(ethyleneterephthalate) modified by different ionizing radiation dose}, series = {Indian Journal of Pure and Applied Physics}, volume = {50}, journal = {Indian Journal of Pure and Applied Physics}, number = {2}, issn = {0019-5596}, pages = {129 -- 132}, year = {2012}, abstract = {Thin films of poly(ethyleneterephthalate) [PET]were exposed to radiation dose ranging from 10 to 30 kGy by using gamma rays in the range 12.8-177.8 MGy using swift light ions of hydrogen. There was no effect of the radiation dose on the optical behaviour of PET as a result of exposure to radiation dose up to 30 kGy brought about by gamma rays but a significant decrease in the optical band gap values was observed when PET was exposed to swift light ions of hydrogen. The data obtained are discussed in terms of optical studies carried out on PET using swift heavy ions.}, language = {en} } @article{StaatTrenzLohmannetal.2012, author = {Staat, Manfred and Trenz, Eva and Lohmann, Philipp and Frotscher, Ralf and Klinge, Uwe and Tabaza, Ruth and Kirschner-Hermanns, Ruth}, title = {New measurements to compare soft tissue anchoring systems in pelvic floor surgery}, series = {Journal of Biomedical Materials Research Part B: Applied Biomaterials}, volume = {100B}, journal = {Journal of Biomedical Materials Research Part B: Applied Biomaterials}, number = {4}, publisher = {Wiley}, address = {Hoboken, NJ}, issn = {1552-4981}, doi = {10.1002/jbm.b.32654}, pages = {924 -- 933}, year = {2012}, abstract = {Suburethral slings as well as different meshes are widely used treating stress urinary incontinence and prolaps in women. With the development of MiniSlings and special meshes using less alloplastic material anchorage systems become more important to keep devices in place and to put some tension especially on the MiniSlings. To date, there are many different systems of MiniSlings of different companies on the market which differ in the structure of the used meshes and anchors. A new objective measurement method to compare different properties of MiniSling systems (mesh and anchor) is presented in this article. Ballistic gelatine acts as soft tissue surrogate. Significant differences in parameters like pull-out strength of anchors or shrinkage of meshes under loading conditions have been determined. The form and size of the anchors as well as the structural stability of the meshes are decisive for a proper integration. The tested anchorings sytems showed markedly different mechanical function at their respective load bearing capacity. As the stable fixation of the device in tissue is a prerequisite for a permanet reinforcement, the proposed test system permits further optimisation of anchor and mesh devices to improve the success of the surgical treatment}, language = {en} } @book{Schmitz2012, author = {Schmitz, G{\"u}nter}, title = {Elektronik im Kraftfahrzeug : Innovationen bei System und Komponenten ; mit 7 Tabellen / Hrsg.: Schmitz, G{\"u}nter}, publisher = {expert-Verl.}, address = {Renningen}, isbn = {978-3-8169-3110-2}, pages = {185 S. : Ill., graph. Darst.}, year = {2012}, language = {de} }