@article{DickhoffHorikawaFunke2021, author = {Dickhoff, Jens and Horikawa, Atsushi and Funke, Harald}, title = {Hydrogen Combustion - new DLE Combustor Addresses NOx Emissions and Flashback}, series = {Turbomachinery international : the global journal of energy equipment}, volume = {62}, journal = {Turbomachinery international : the global journal of energy equipment}, number = {4}, publisher = {MJH Life Sciences}, address = {Cranbury}, issn = {2767-2328}, pages = {26 -- 27}, year = {2021}, language = {en} } @article{WeldenJablonskiWegeetal.2021, author = {Welden, Rene and Jablonski, Melanie and Wege, Christina and Keusgen, Michael and Wagner, Patrick Hermann and Wagner, Torsten and Sch{\"o}ning, Michael Josef}, title = {Light-Addressable Actuator-Sensor Platform for Monitoring and Manipulation of pH Gradients in Microfluidics: A Case Study with the Enzyme Penicillinase}, series = {Biosensors}, volume = {11}, journal = {Biosensors}, number = {6}, publisher = {MDPI}, address = {Basel}, issn = {2079-6374}, doi = {10.3390/bios11060171}, pages = {Artikel 171}, year = {2021}, abstract = {The feasibility of light-addressed detection and manipulation of pH gradients inside an electrochemical microfluidic cell was studied. Local pH changes, induced by a light-addressable electrode (LAE), were detected using a light-addressable potentiometric sensor (LAPS) with different measurement modes representing an actuator-sensor system. Biosensor functionality was examined depending on locally induced pH gradients with the help of the model enzyme penicillinase, which had been immobilized in the microfluidic channel. The surface morphology of the LAE and enzyme-functionalized LAPS was studied by scanning electron microscopy. Furthermore, the penicillin sensitivity of the LAPS inside the microfluidic channel was determined with regard to the analyte's pH influence on the enzymatic reaction rate. In a final experiment, the LAE-controlled pH inhibition of the enzyme activity was monitored by the LAPS.}, language = {en} } @article{CapitainWagnerHummeletal.2021, author = {Capitain, Charlotte and Wagner, Sebastian and Hummel, Joana and Tippk{\"o}tter, Nils}, title = {Investigation of C-N Formation Between Catechols and Chitosan for the Formation of a Strong, Novel Adhesive Mimicking Mussel Adhesion}, series = {Waste and Biomass Valorization}, volume = {12}, journal = {Waste and Biomass Valorization}, publisher = {Springer Nature}, address = {Cham}, issn = {1877-265X}, doi = {10.1007/s12649-020-01110-5}, pages = {1761 -- 1779}, year = {2021}, language = {en} } @article{FaganBitzBjoerkmanBurtscheretal.2021, author = {Fagan, Andrew J. and Bitz, Andreas and Bj{\"o}rkman-Burtscher, Isabella M. and Collins, Christopher M. and Kimbrell, Vera and Raaijmakers, Alexander J. E.}, title = {7T MR Safety}, series = {Journal of Magnetic Resonance Imaging (JMRI)}, volume = {53}, journal = {Journal of Magnetic Resonance Imaging (JMRI)}, number = {2}, publisher = {Wiley}, address = {Weinheim}, issn = {1522-2586}, doi = {10.1002/jmri.27319}, pages = {333 -- 346}, year = {2021}, language = {en} } @article{BlankeHagenkampDoeringetal.2021, author = {Blanke, Tobias and Hagenkamp, Markus and D{\"o}ring, Bernd and G{\"o}ttsche, Joachim and Reger, Vitali and Kuhnhenne, Markus}, title = {Net-exergetic, hydraulic and thermal optimization of coaxial heat exchangers using fixed flow conditions instead of fixed flow rates}, series = {Geothermal Energy}, volume = {9}, journal = {Geothermal Energy}, number = {Article number: 19}, publisher = {Springer}, address = {Berlin}, issn = {2195-9706}, doi = {10.1186/s40517-021-00201-3}, pages = {23 Seiten}, year = {2021}, abstract = {Previous studies optimized the dimensions of coaxial heat exchangers using constant mass fow rates as a boundary condition. They show a thermal optimal circular ring width of nearly zero. Hydraulically optimal is an inner to outer pipe radius ratio of 0.65 for turbulent and 0.68 for laminar fow types. In contrast, in this study, fow conditions in the circular ring are kept constant (a set of fxed Reynolds numbers) during optimization. This approach ensures fxed fow conditions and prevents inappropriately high or low mass fow rates. The optimization is carried out for three objectives: Maximum energy gain, minimum hydraulic efort and eventually optimum net-exergy balance. The optimization changes the inner pipe radius and mass fow rate but not the Reynolds number of the circular ring. The thermal calculations base on Hellstr{\"o}m's borehole resistance and the hydraulic optimization on individually calculated linear loss of head coefcients. Increasing the inner pipe radius results in decreased hydraulic losses in the inner pipe but increased losses in the circular ring. The net-exergy diference is a key performance indicator and combines thermal and hydraulic calculations. It is the difference between thermal exergy fux and hydraulic efort. The Reynolds number in the circular ring is instead of the mass fow rate constant during all optimizations. The result from a thermal perspective is an optimal width of the circular ring of nearly zero. The hydraulically optimal inner pipe radius is 54\% of the outer pipe radius for laminar fow and 60\% for turbulent fow scenarios. Net-exergetic optimization shows a predominant infuence of hydraulic losses, especially for small temperature gains. The exact result depends on the earth's thermal properties and the fow type. Conclusively, coaxial geothermal probes' design should focus on the hydraulic optimum and take the thermal optimum as a secondary criterion due to the dominating hydraulics.}, language = {en} } @article{TranEbeling2021, author = {Tran, Duc Hung and Ebeling, Felix}, title = {Die risikoad{\"a}quate Bestimmung von Eigenkapitalkosten bei konzerninternen Routinefunktionen}, series = {Der Betrieb}, volume = {74}, journal = {Der Betrieb}, number = {29}, issn = {0005-9935}, pages = {1553 -- 1560}, year = {2021}, abstract = {Eigenkapitalkosten sind eine wesentliche Determinante bei der Wertbestimmung von Unternehmen und Unternehmensteilen. Die Eigenkapitalkosten werden regelm{\"a}ßig mittels des CAPM bestimmt. F{\"u}r sog. konzerninterne Routinefunktionen mit geringem Risiko stellt diese Bestimmung mittels CAPM ein Problem dar, da b{\"o}rsennotierte Peergroups f{\"u}r eine zuverl{\"a}ssige Bestimmung des Beta-Faktors meist nicht identifizierbar sind. Damit ergeben sich bei Bewertungen von Routineunternehmen Unsicherheiten und Konfliktpotenzial in steuerlichen Betriebspr{\"u}fungen. Dieser Beitrag gibt einen {\"U}berblick der in der Praxis genutzten Ans{\"a}tze und stellt eine theoretische Fundierung zur Bestimmung der Eigenkapitalkosten von konzerninternen Routinefunktionen vor. Dabei wird verdeutlicht, dass Eigenkapitalkosten von konzerninternen Routinefunktionen nicht denen des Gesamtkonzerns entsprechen und Praktikerans{\"a}tze eine grunds{\"a}tzliche Berechtigung besitzen.}, language = {de} } @article{PoghossianSchoening2021, author = {Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Recent progress in silicon-based biologically sensitive field-effect devices}, series = {Current Opinion in Electrochemistry}, journal = {Current Opinion in Electrochemistry}, number = {Article number: 100811}, publisher = {Elsevier}, address = {Amsterdam}, issn = {2451-9103}, doi = {10.1016/j.coelec.2021.100811}, year = {2021}, abstract = {Biologically sensitive field-effect devices (BioFEDs) advantageously combine the electronic field-effect functionality with the (bio)chemical receptor's recognition ability for (bio)chemical sensing. In this review, basic and widely applied device concepts of silicon-based BioFEDs (ion-sensitive field-effect transistor, silicon nanowire transistor, electrolyte-insulator-semiconductor capacitor, light-addressable potentiometric sensor) are presented and recent progress (from 2019 to early 2021) is discussed. One of the main advantages of BioFEDs is the label-free sensing principle enabling to detect a large variety of biomolecules and bioparticles by their intrinsic charge. The review encompasses applications of BioFEDs for the label-free electrical detection of clinically relevant protein biomarkers, deoxyribonucleic acid molecules and viruses, enzyme-substrate reactions as well as recording of the cell acidification rate (as an indicator of cellular metabolism) and the extracellular potential.}, language = {en} } @article{HugenrothBorchardtRitteretal.2021, author = {Hugenroth, Kristin and Borchardt, Ralf and Ritter, Philine and Groß‑Hardt, Sascha and Meyns, Bart and Verbelen, Tom and Steinseifer, Ulrich and Kaufmann, Tim A. S. and Engelmann, Ulrich M.}, title = {Optimizing cerebral perfusion and hemodynamics during cardiopulmonary bypass through cannula design combining in silico, in vitro and in vivo input}, series = {Scientific Reports}, volume = {11}, journal = {Scientific Reports}, number = {Art. No. 16800}, publisher = {Springer}, address = {Berlin}, issn = {2045-2322}, doi = {10.1038/s41598-021-96397-2}, pages = {1 -- 12}, year = {2021}, abstract = {Cardiopulmonary bypass (CPB) is a standard technique for cardiac surgery, but comes with the risk of severe neurological complications (e.g. stroke) caused by embolisms and/or reduced cerebral perfusion. We report on an aortic cannula prototype design (optiCAN) with helical outflow and jet-splitting dispersion tip that could reduce the risk of embolic events and restores cerebral perfusion to 97.5\% of physiological flow during CPB in vivo, whereas a commercial curved-tip cannula yields 74.6\%. In further in vitro comparison, pressure loss and hemolysis parameters of optiCAN remain unaffected. Results are reproducibly confirmed in silico for an exemplary human aortic anatomy via computational fluid dynamics (CFD) simulations. Based on CFD simulations, we firstly show that optiCAN design improves aortic root washout, which reduces the risk of thromboembolism. Secondly, we identify regions of the aortic intima with increased risk of plaque release by correlating areas of enhanced plaque growth and high wall shear stresses (WSS). From this we propose another easy-to-manufacture cannula design (opti2CAN) that decreases areas burdened by high WSS, while preserving physiological cerebral flow and favorable hemodynamics. With this novel cannula design, we propose a cannulation option to reduce neurological complications and the prevalence of stroke in high-risk patients after CPB.}, language = {en} } @article{NeumaierWeissVeldemanetal.2021, author = {Neumaier, Felix and Weiss, Miriam and Veldeman, Michael and Kotliar, Konstantin and Wiesmann, Martin and Schulze-Steinen, Henna and H{\"o}llig, Anke and Clusmann, Hans and Schubert, Gerrit Alexander and Albanna, Walid}, title = {Changes in endogenous daytime melatonin levels after aneurysmal subarachnoid hemorrhage - preliminary findings from an observational cohort study}, series = {Clinical Neurology and Neurosurgery}, volume = {208}, journal = {Clinical Neurology and Neurosurgery}, number = {Article No.: 106870}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0303-8467}, doi = {10.1016/j.clineuro.2021.106870}, year = {2021}, abstract = {Aneurysmal subarachnoid hemorrhage (aSAH) is associated with early and delayed brain injury due to several underlying and interrelated processes, which include inflammation, oxidative stress, endothelial, and neuronal apoptosis. Treatment with melatonin, a cytoprotective neurohormone with anti-inflammatory, anti-oxidant and anti-apoptotic effects, has been shown to attenuate early brain injury (EBI) and to prevent delayed cerebral vasospasm in experimental aSAH models. Less is known about the role of endogenous melatonin for aSAH outcome and how its production is altered by the pathophysiological cascades initiated during EBI. In the present observational study, we analyzed changes in melatonin levels during the first three weeks after aSAH.}, language = {en} } @article{BrockhausBehbahaniMurisetal.2021, author = {Brockhaus, Moritz K. and Behbahani, Mehdi and Muris, Farina and Jansen, Sebastian V. and Schmitz- Rode, Thomas and Steinseifer, Ulrich and Clauser, Johanna C.}, title = {In vitro thrombogenicity testing of pulsatile mechanical circulatory support systems: Design and proof-of-concept}, series = {Artificial Organs}, volume = {45}, journal = {Artificial Organs}, number = {12}, publisher = {Wiley}, address = {Weinheim}, issn = {1525-1594}, doi = {10.1111/aor.14046}, pages = {1513 -- 1521}, year = {2021}, abstract = {Thrombogenic complications are a main issue in mechanical circulatory support (MCS). There is no validated in vitro method available to quantitatively assess the thrombogenic performance of pulsatile MCS devices under realistic hemodynamic conditions. The aim of this study is to propose a method to evaluate the thrombogenic potential of new designs without the use of complex in-vivo trials. This study presents a novel in vitro method for reproducible thrombogenicity testing of pulsatile MCS systems using low molecular weight heparinized porcine blood. Blood parameters are continuously measured with full blood thromboelastometry (ROTEM; EXTEM, FIBTEM and a custom-made analysis HEPNATEM). Thrombus formation is optically observed after four hours of testing. The results of three experiments are presented each with two parallel loops. The area of thrombus formation inside the MCS device was reproducible. The implantation of a filter inside the loop catches embolizing thrombi without a measurable increase of platelet activation, allowing conclusions of the place of origin of thrombi inside the device. EXTEM and FIBTEM parameters such as clotting velocity (α) and maximum clot firmness (MCF) show a total decrease by around 6\% with a characteristic kink after 180 minutes. HEPNATEM α and MCF rise within the first 180 minutes indicate a continuously increasing activation level of coagulation. After 180 minutes, the consumption of clotting factors prevails, resulting in a decrease of α and MCF. With the designed mock loop and the presented protocol we are able to identify thrombogenic hot spots inside a pulsatile pump and characterize their thrombogenic potential.}, language = {en} }