@book{Mandelartz2000, author = {Mandelartz, Johannes}, title = {Der Sekund{\"a}raluminium-Stoffstrom in Deutschland unter transporttechnischen und logistischen Gesichtspunkten}, publisher = {Mainz}, address = {Aachen}, isbn = {3-86073-672-8}, pages = {III, 121 S. : graph. Darst. ; 21 cm}, year = {2000}, subject = {Aluminium}, language = {de} } @incollection{Mandelartz2009, author = {Mandelartz, Johannes}, title = {VDI-Richtlinien - mit Technischen Regeln Wirtschaftlichkeit erh{\"o}hen und Standards setzen}, series = {Betriebliche Instandhaltung}, booktitle = {Betriebliche Instandhaltung}, publisher = {Springer}, address = {Berlin [u.a.]}, isbn = {978-3-642-00502-2}, doi = {10.1007/978-3-642-00502-2_26}, pages = {311 -- 317}, year = {2009}, abstract = {Der Verein Deutscher Ingenieure e.V. (VDI) ist ein gemeinn{\"u}tziger, wirtschaftlich und politisch unabh{\"a}ngiger, technisch-wissenschaftlicher Verein von Ingenieuren und Naturwissenschaftlern. Mit {\"u}ber 137 000 pers{\"o}nlich zugeordneten Mitgliedern ist er eine der gr{\"o}ßten Ingenieur-Vereinigungen Europas und gilt in Deutschland als f{\"u}hrender Sprecher der Technik und der Ingenieure. 1856 gegr{\"u}ndet, hat er viele f{\"u}r die Technik wesentliche Entwicklungen in Gang gesetzt, so im Bereich der technischen {\"U}berwachung, der technischen Regelsetzung und Normung, der Arbeitsstudien, im gewerblichen Rechtsschutz und im Patentwesen. Seit seiner Gr{\"u}ndung sieht es der VDI als seine Aufgabe, "das Zusammenwirken aller geistiger Kr{\"a}fte der Technik im Bewusstsein ethischer Verantwortung zu f{\"o}rdern" und die Lebensm{\"o}glichkeiten aller Menschen durch Entwicklung und sinnvoller Anwendung technischer Mittel zu verbessern.}, language = {de} } @book{ReichelMuellerMandelartz2009, author = {Reichel, Jens and M{\"u}ller, Gerhard and Mandelartz, Johannes}, title = {Betriebliche Instandhaltung}, publisher = {Springer}, address = {Berlin [u.a.]}, isbn = {978-3-642-00502-2}, pages = {XXI, 354 S. Ill., graph. Darst.}, year = {2009}, subject = {Unternehmen}, language = {de} } @article{KirchnerOberlaenderSusoetal.2013, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Suso, Henri-Pierre and Rysstad, Gunnar and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Towards a wireless sensor system for real-time H2O2 monitoring in aseptic food processes}, series = {Physica status solidi (a)}, volume = {210}, journal = {Physica status solidi (a)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201200920}, pages = {877 -- 883}, year = {2013}, abstract = {A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests.}, language = {en} } @article{KhodaverdiChatziioannouWeberetal.2005, author = {Khodaverdi, M. and Chatziioannou, A. F. and Weber, S. and Ziemons, Karl and Halling, H. and Pietrzyk, U.}, title = {Investigation of different MicroCT scanner configurations by GEANT4 simulations}, series = {IEEE Transactions on Nuclear Science}, volume = {52}, journal = {IEEE Transactions on Nuclear Science}, number = {1}, isbn = {0018-9499}, pages = {188 -- 192}, year = {2005}, abstract = {This study has been performed to design the combination of the new ClearPET (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal positron emission tomography (PET) system, with a micro-computed tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We will demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material.}, language = {en} } @article{StreunBrandenburgLarueetal.2006, author = {Streun, M. and Brandenburg, G. and Larue, H. and Parl, C. and Ziemons, Karl}, title = {The data acquisition system of ClearPET neuro - a small animal PET scanner}, series = {IEEE Transactions on Nuclear Science}, volume = {53}, journal = {IEEE Transactions on Nuclear Science}, number = {3}, isbn = {0018-9499}, pages = {700 -- 703}, year = {2006}, abstract = {The Crystal Clear Collaboration has developed a modular system for a small animal PET scanner (ClearPET). The modularity allows the assembly of scanners of different sizes and characteristics in order to satisfy the specific needs of the individual member institutions. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to Multichannel Photomultipliers (PMTs). For each PMT a free running 40 MHz ADC digitizes the signal and the complete scintillation pulse is sampled by an FPGA and sent with 20 MB/s to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. The system in J{\"u}lich (ClearPET Neuro) is equipped with 10240 crystals on 80 PMTs. The paper will present an overview of the data acquisition system.}, language = {en} } @article{KhodaverdiWeberStreunetal.2006, author = {Khodaverdi, M. and Weber, S. and Streun, M. and Parl, C. and Ziemons, Karl}, title = {High resolution imaging with ClearPET™ Neuro - first animal images}, series = {2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, journal = {2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, isbn = {1082-3654}, pages = {1641 -- 1644}, year = {2006}, abstract = {The ClearPET™ Neuro is the first full ring scanner within the Crystal Clear Collaboration (CCC). It consists of 80 detector modules allocated to 20 cassettes. LSO and LuYAP:Ce crystals in phoswich configuration in combination with position sensitive photomultiplier tubes are used to achieve high sensitivity and realize the acquisition of the depth of interaction (DOI) information. The complete system has been tested concerning the mechanical and electronical stability and interplay. Moreover, suitable corrections have been implemented into the reconstruction procedure to ensure high image quality. We present first results which show the successful operation of the ClearPET™ Neuro for artefact free and high resolution small animal imaging. Based on these results during the past few months the ClearPET™ Neuro System has been modified in order to optimize the performance.}, language = {en} } @article{StreunBrandenburgKhodaverdietal.2006, author = {Streun, M. and Brandenburg, G. and Khodaverdi, M. and Larue, H. and Parl, C. and Ziemons, Karl}, title = {Timemark correction for the ClearPET™ scanners}, series = {2005 IEEE Nuclear Science Symposium Conference Record, Vol. 4}, journal = {2005 IEEE Nuclear Science Symposium Conference Record, Vol. 4}, isbn = {1082-3654}, pages = {2057 -- 2060}, year = {2006}, abstract = {The small animal PET scanners developed by the Crystal Clear Collaboration (ClearPETtrade) detect coincidences by analyzing timemarks which are attached to each event. The scanners are able to save complete single list mode data which allows analysis and modification of the timemarks after data acquisition. The timemarks are obtained from the digitally sampled detector pulses by calculating the baseline crossing of the rising edge of the pulse which is approximated as a straight line. But the limited sampling frequency causes a systematic error in the determination of the timemark. This error depends on the phase of the sampling clock at the time of the event. A statistical method that corrects these errors will be presented}, language = {en} } @article{Meliss1997, author = {Meliß, Michael}, title = {Regenerative Energiequellen}, series = {Brennstoff, W{\"a}rme, Kraft : BWK ; das Energie-Fachmagazin. Bd. 49 (1997), H. 4}, journal = {Brennstoff, W{\"a}rme, Kraft : BWK ; das Energie-Fachmagazin. Bd. 49 (1997), H. 4}, issn = {0006-9612 (Print) ; 1436-4883 (E-Journal)}, pages = {68 -- 75}, year = {1997}, language = {de} } @article{Meliss1997, author = {Meliß, Michael}, title = {Aktuelle Aspekte der Windkraftnutzung}, series = {Energiewirtschaftliche Tagesfragen. Jg. 47 (1997), H. 9}, journal = {Energiewirtschaftliche Tagesfragen. Jg. 47 (1997), H. 9}, issn = {0013-743X}, pages = {531 -- 532}, year = {1997}, language = {de} }