@article{FrauenrathHezelRenzetal.2010, author = {Frauenrath, Tobias and Hezel, Fabian and Renz, Wolfgang and de Geyer d'Orth, Thibaut and Dieringer, Matthias and von Knobelsdorf-Brenkenhoff, Florian and Prothmann, Marcel and Schulz-Menger, Jeanette and Niendorf, Thoralf}, title = {Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla}, series = {Journal of Cardiovascular Magnetic Resonance}, volume = {12}, journal = {Journal of Cardiovascular Magnetic Resonance}, number = {1}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1532-429X}, doi = {10.1186/1532-429X-12-67}, year = {2010}, abstract = {Background To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oximetry (POX) triggered 2D CINE acquisitions together with (i) a qualitative image quality analysis, (ii) an assessment of the left ventricular function parameter and (iii) an examination of trigger reliability and trigger detection variance derived from the signal waveforms. Results ECG was susceptible to severe distortions at 7.0 T. POX and ACT provided waveforms free of interferences from electromagnetic fields or from magneto-hydrodynamic effects. Frequent R-wave mis-registration occurred in ECG-triggered acquisitions with a failure rate of up to 30\% resulting in cardiac motion induced artifacts. ACT and POX triggering produced images free of cardiac motion artefacts. ECG showed a severe jitter in the R-wave detection. POX also showed a trigger jitter of approximately Δt = 72 ms which is equivalent to two cardiac phases. ACT showed a jitter of approximately Δt = 5 ms only. ECG waveforms revealed a standard deviation for the cardiac trigger offset larger than that observed for ACT or POX waveforms. Image quality assessment showed that ACT substantially improved image quality as compared to ECG (image quality score at end-diastole: ECG = 1.7 ± 0.5, ACT = 2.4 ± 0.5, p = 0.04) while the comparison between ECG vs. POX gated acquisitions showed no significant differences in image quality (image quality score: ECG = 1.7 ± 0.5, POX = 2.0 ± 0.5, p = 0.34). Conclusions The applicability of acoustic triggering for cardiac CINE imaging at 7.0 T was demonstrated. ACT's trigger reliability and fidelity are superior to that of ECG and POX. ACT promises to be beneficial for cardiovascular magnetic resonance at ultra-high field strengths including 7.0 T.}, language = {en} } @article{MartinFrauenrathOezerdemetal.2011, author = {Martin, Conrad and Frauenrath, Tobias and {\"O}zerdem, Celal and Renz, Wolfgang and Niendorf, Thoralf}, title = {Development and evaluation of a small and mobile Magneto Alert Sensor (MALSE) to support safety requirements for magnetic resonance imaging}, series = {European Radiology}, volume = {21}, journal = {European Radiology}, publisher = {Springer}, address = {Berlin, Heidelberg}, issn = {1432-1084}, doi = {10.1007/s00330-011-2153-z}, pages = {2187 -- 2192}, year = {2011}, abstract = {Objective The purpose of this study is to (i) design a small and mobile Magnetic field ALert SEnsor (MALSE), (ii) to carefully evaluate its sensors to their consistency of activation/deactivation and sensitivity to magnetic fields, and (iii) to demonstrate the applicability of MALSE in 1.5 T, 3.0 T and 7.0 T MR fringe field environments. Methods MALSE comprises a set of reed sensors, which activate in response to their exposure to a magnetic field. The activation/deactivation of reed sensors was examined by moving them in/out of the fringe field generated by 7TMR. Results The consistency with which individual reed sensors would activate at the same field strength was found to be 100\% for the setup used. All of the reed switches investigated required a substantial drop in ambient magnetic field strength before they deactivated. Conclusions MALSE is a simple concept for alerting MRI staff to a ferromagnetic object being brought into fringe magnetic fields which exceeds MALSEs activation magnetic field. MALSE can easily be attached to ferromagnetic objects within the vicinity of a scanner, thus creating a barrier for hazardous situations induced by ferromagnetic parts which should not enter the vicinity of an MR-system to occur.}, language = {en} } @misc{BragardHueningKowalewski2023, author = {Bragard, Michael and H{\"u}ning, Felix and Kowalewski, Paul}, title = {Vorrichtung zur Relativlagenbestimmung [Offenlegungschrift]}, year = {2023}, abstract = {Die Erfindung betrifft eine Vorrichtung zur Bestimmung einer Relativlage zwischen einem feststehenden Teil und einem zu demselben in eine Bewegungsrichtung bewegbaren beweglichen Teil, wobei der feststehende Teil mit einem Wiegandsensor versehen ist, wobei der Wiegandsensor zwischen zwei gegenpolig zueinander ausgebildeten Permanentmagneten angeordnet ist und dass der bewegliche Teil eine Mehrzahl von beabstandet zueinander angeordneten Magnetisierungsstegen aus einem magnetisch leitenden Material aufweist, die in der Bewegungsrichtung zumindest eine gleich große Erstreckung aufweisen wie der Permanentmagnet, dass ein Abstand zwischen benachbarten Magnetisierungsstegen derart gew{\"a}hlt ist, dass in einer ersten Relativlage ein erster Permanentmagnet von einem der Magnetisierungsstege {\"u}berdeckt ist und ein zweiter Permanentmagnet nicht von einem der Magnetisierungsstege {\"u}berdeckt ist.}, language = {de} } @inproceedings{PenneProfittlichRingbecketal.2010, author = {Penne, Jochen and Profittlich, Martin and Ringbeck, Thorsten and Buxbaum, Bernd}, title = {Touchless detailed 3D scan of human hand anatomy using time-of-flight cameras}, series = {Proceedings of the International Conference on 3D Body Scanning Technologies : Lugano, Switzerland, 19-20 October 2010}, booktitle = {Proceedings of the International Conference on 3D Body Scanning Technologies : Lugano, Switzerland, 19-20 October 2010}, editor = {D, Nicola D'Apuzzo}, publisher = {Hometrica Consulting}, address = {Z{\"u}rich}, isbn = {978-3-033-02714-5}, pages = {361 -- 369}, year = {2010}, language = {en} } @techreport{LessenichRitzWallenborn2014, author = {Leßenich, Nina and Ritz, Thomas and Wallenborn, Ramona}, title = {Prototyping zur Verbesserung der Benutzerfreundlichkeit mobiler Software : Potenziale benutzerfreundlicher Software-Entwicklung ; Info-Brosch{\"u}re}, publisher = {eBusiness-Lotse}, address = {Aachen}, pages = {7 S. : Ill., graph. Darst.}, year = {2014}, abstract = {Mobile Anwendungen nehmen mit der Verbreitung von Smartphones zu. Die Akzeptanz der Nutzer bestimmt den Erfolg solcher mobiler Applikationen dabei maßgeblich. Um diese Anerkennung zu schaffen, ist eine m{\"o}glichst hohe Gebrauchstauglichkeit, auch Usability genannt, notwendig. Die Informationsbrosch{\"u}re „Prototyping zur Verbesserung der Benutzerfreundlichkeit mobiler Software" richtet sich an Personen, die an der Gestaltung und entwicklung von (mobiler) Software beteiligt sind. In dieser Brosch{\"u}re werden m{\"o}gliche Potenziale im Bereich einer effizienten und benutzerzentrierten Software-Entwicklung aufgezeigt.}, language = {de} } @misc{HilgenstockLangeRiedeletal.2006, author = {Hilgenstock, J{\"o}rg and Lange, Robert and Riedel, Helmut and Ringbeck, Thorsten}, title = {Verfahren und Entfernungsmessvorrichtung zum Bestimmen der Entfernung zwischen einem Objekt und der Vorrichtung : [Offenlegungsschrift / Europ{\"a}ische Patentanmeldung]}, publisher = {Deutsches Patent- und Markenamt / Europ{\"a}isches Patentamt}, address = {M{\"u}nchen / Den Hague}, year = {2006}, language = {de} } @article{RitzPisarczykSachtlebenetal.2014, author = {Ritz, Thomas and Pisarczyk, Rafael and Sachtleben, Johanna and Leßenich, Nina}, title = {Usability Engineering maßgeschneidert : Modellbaukasten zur Entwicklung gebrauchstauglicher mobiler Software}, series = {Wissenschaft trifft Praxis}, volume = {1}, journal = {Wissenschaft trifft Praxis}, number = {1}, publisher = {Begleitforschung Mittelstand-Digital c/o WIK-Consult GmbH}, address = {Bad Honnef}, issn = {2198-8544 (Print)}, pages = {79 -- 88}, year = {2014}, language = {de} } @article{WallenbornRitz2014, author = {Wallenborn, Ramona and Ritz, Thomas}, title = {Mobilit{\"a}t miteinander teilen : st{\"a}dtisches eCarsharing in einer vernetzten Gesellschaft ; [vernetztes Fahren von morgen]}, series = {Neue Mobilit{\"a}t : das Magazin vom Bundesverband eMobilit{\"a}t}, volume = {5}, journal = {Neue Mobilit{\"a}t : das Magazin vom Bundesverband eMobilit{\"a}t}, number = {14 (Herbstausg.)}, publisher = {Bundesverband eMobilit{\"a}t BEM}, address = {Berlin}, issn = {2191-5636}, pages = {92 -- 95}, year = {2014}, language = {de} } @techreport{RahierRitzWallenborn2014, author = {Rahier, Michael and Ritz, Thomas and Wallenborn, Ramona}, title = {Elektromobilit{\"a}t in einer vernetzten Welt : Potenziale f{\"u}r die IT-Branche bei der Organisation der Mobilit{\"a}t von morgen ; Info-Brosch{\"u}re}, publisher = {eBusiness-Lotse}, address = {Aachen}, pages = {9 S. : Ill., graph. Darst.}, year = {2014}, abstract = {Die Informationsbrosch{\"u}re „Elektromobilit{\"a}t in einer vernetzten Welt" richtet sich an IT-Dienstleister. In dieser Brosch{\"u}re werden m{\"o}gliche Potenziale im Bereich der Elektromobilit{\"a}t aufgezeigt. Die Mobilit{\"a}t der Zukunft ist eine interdisziplin{\"a}re Angelegenheit und kein reines Automotive-Thema mehr. Beispiele wie Mobilit{\"a}tsmanagement, eCommerce und Individualisierung sind im Mobilit{\"a}tsbereich f{\"u}r die IT-Branche relevant.}, language = {de} } @inproceedings{SchwarteBuxbaumHeinoletal.1998, author = {Schwarte, Rudolf and Buxbaum, Bernd and Heinol, Horst-Guenther and Xu, Zhanping and Ringbeck, Thorsten and Zang, Zhigang}, title = {Novel 3D-vision systems based on layout optimized PMD-structures}, series = {Proceedings / OPTO 98, Internationaler Kongress und Fachausstellung f{\"u}r Optische Sensorik, Messtechnik und Elektronik, 18. - 20. Mai 1998, Kongreßzentrum Erfurt}, booktitle = {Proceedings / OPTO 98, Internationaler Kongress und Fachausstellung f{\"u}r Optische Sensorik, Messtechnik und Elektronik, 18. - 20. Mai 1998, Kongreßzentrum Erfurt}, publisher = {ACS Organisations GmbH}, address = {Wunsdorf}, pages = {197 -- 202}, year = {1998}, language = {en} }