@misc{FrauenrathFuchsHezeletal.2012, author = {Frauenrath, Tobias and Fuchs, Katharina and Hezel, Fabian and Dieringer, Matthias A. and Rieger, Jan and Niendorf, Thoralf}, title = {Improved cardiac triggering by combining multiple physiological signals: a cardiac MR feasibility study at 7.0 T}, series = {2012 ISMRM Annual Meeting Proceedings}, journal = {2012 ISMRM Annual Meeting Proceedings}, issn = {1545-4428}, year = {2012}, abstract = {In current clinical cardiovascular MR (CMR) practice cardiac motion is commonly dealt with using ECG based synchronization. However, ECG is corrupted by magneto-hydrodynamic (MHD) effects in magnetic fields. This leads to artifacts in the ECG trace and evokes severe T-wave elevations, which might be misinterpreted as R-waves resulting in erroneous triggering. At (ultra)high field strengths, the propensity of ECG recordings to MHD effects is further pronounced. Pulse oximetry (POX) being inherently sensitive to blood oxygenation provides an alternative approach for cardiac gating. However, due to the travel time of the blood the peak of maximum oxygenation and hence the trigger is delayed by approx. 300 ms with respect to the ECG's R-wave. Also the peak of maximum oxygenation shows a jitter of up to 65 ms. Alternative triggering approaches include acoustic cardiac triggering (ACT). In current clinical practice cardiac gating / triggering commonly relies on using single physiological signals only. Realizing this limitation this study proposes a combined triggering approach which exploits multiple physiological signals including ECG, POX or ACT to track cardiac activity. The feasibility of the coupled approach is examined for LV function assessment at 7.0 T. For this purpose, breath-held 2D-CINE imaging in conjunction with cardiac synchronization was performed paralleled by real time logging of physiological waveforms to track (mis)synchronization between the cardiac cycle and data acquisition. Combinations of the ECG, POX and ACT signals were evaluated and processed in real time to facilitate reliable trigger information.}, language = {en} } @misc{GraesslRenzHezeletal.2012, author = {Gr{\"a}ßl, Andreas and Renz, Wolfgang and Hezel, Fabian and Frauenrath, Tobias and Pfeiffer, Harald and Hoffmann, Werner and Kellmann, Peter and Martin, Conrad and Niendorf, Thoralf}, title = {Design, evaluation and application of a modular 32 channel transmit/receive surface coil array for cardiac MRI at 7T}, series = {2012 ISMRM Annual Meeting Proceedings}, journal = {2012 ISMRM Annual Meeting Proceedings}, issn = {1545-4428}, year = {2012}, abstract = {Cardiac MR (CMR) at ultrahigh (≥7.0 T) fields is regarded as one of the most challenging MRI applications. At 7.0 T image quality is not always exclusively defined by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Detrimental effects bear the potential to spoil the signal-to-noise (SNR) and contrast-to-noise (CNR) benefits of cardiac MR (CMR) at 7.0 T. B₁⁺-inhomogeneities and signal voids represent the main challenges. Various pioneering coil concepts have been proposed to tackle these issues, enabling cardiac MRI at 7.0 T. This includes a trend towards an ever larger number of transmit and receive channels. This approach affords multi-dimensional B₁⁺ modulations to improve B₁⁺ shimming performance and to enhance RF efficiency. Also, parallel imaging benefits from a high number of receive channels enabling two-dimensional acceleration. Realizing the limitations of existing coil designs tailored for UHF CMR and recognizing the opportunities of a many element TX/RX channel architecture this work proposes a modular, two dimensional 32-channel transmit and receive array using loop elements and examines its efficacy for enhanced B¹+ homogeneity and improved parallel imaging performance.}, language = {en} } @misc{TkachenkovonKnobelsdorffBrenkenhoffKleindienstetal.2012, author = {Tkachenko, Valeriy and von Knobelsdorff-Brenkenhoff, Florian and Kleindienst, Denise and Winter, Lukas and Rieger, Jan and Frauenrath, Tobias and Dieringer, Matthias A. and Santoro, Davide and Niendorf, Thoralf and Schulz-Menger, Jeanette}, title = {Cardiovasular MR at 7Tesla: assessment of the right ventricle}, series = {2012 ISMRM Annual Meeting Proceedings}, journal = {2012 ISMRM Annual Meeting Proceedings}, issn = {1545-4428}, year = {2012}, abstract = {The assessment of the right ventricle (RV) is a challenge in today's cardiology, but of growing clinical impact regarding patient prognosis in different cardiac diseases. The detection and differentiation of small wall motion abnormalities may help to enhance the differentiation of cardiomyopathies including Arrhythmogenic Rightventricular Cardiomyopathy. Cardiovascular magnetic resonance (CMR) at 1.5T is the accepted gold standard for RV quantification. The higher spatial resolution achievable at ultrahigh field strength (UHF) offers the potential to gain new insights into the structure and function of the RV. To approach this goal accurate RV chamber quantification at 7T has to be proven. Consequently this study examines the feasibility of assessment of RV dimensions and function at 7T using improved spatial resolution enabled by the intrinsic sensitivity gain of UHF CMR. For this purpose, a dedicated 16 channel TX/RX RF coil array is used together with 2D CINE fast gradient echo (FGRE) imaging. For comparison RV chamber quantification is conducted at 1.5T using a SSFP based state of the art clinical protocol.}, language = {en} } @incollection{MoorkampPetersonUibel2022, author = {Moorkamp, Wilfried and Peterson, Leif Arne and Uibel, Thomas}, title = {Nachhaltige Holzbr{\"u}cken f{\"u}r Geh- und Radwege}, series = {Bauphysik Kalender 2022: Holzbau, 22. Jahrgang}, booktitle = {Bauphysik Kalender 2022: Holzbau, 22. Jahrgang}, editor = {Fouad, Nabil A.}, publisher = {Ernst \& Sohn}, address = {Berlin}, isbn = {9783433033609 (Print)}, doi = {10.1002/9783433611081.ch17}, pages = {574 -- 592}, year = {2022}, abstract = {Am Lehr- und Forschungsgebiet Holzbau der Fachhochschule Aachen wurden im Rahmen des Forschungsvorhabens „Nachhaltige Standardbr{\"u}cken in Holzbauweise" Standardtypen f{\"u}r Geh- und Radwegbr{\"u}cken entwickelt. Die Br{\"u}cken sind durch konsequente Umsetzungen von Maßnahmen des konstruktiven Holzschutzes f{\"u}r eine Nutzung von mehr als 80~Jahren konzipiert. Innovative L{\"o}sungen f{\"u}r Bauteile und Anschl{\"u}sse sowie Materialalternativen im Bereich des Belages und der Gel{\"a}nder erm{\"o}glichen eine wartungsarme Konstruktion und tragen somit zur Wirtschaftlichkeit und Nachhaltigkeit bei. Um den Einsatz der entwickelten Standardbr{\"u}ckentypen in der Praxis zu erleichtern, wurden Leistungsverzeichnisse, Musterstatiken, Musterzeichnungen und umfangreiche Detailkataloge als Unterst{\"u}tzung f{\"u}r Planer und Bauherren erstellt. Damit die Randbedingungen f{\"u}r eine lange Lebensdauer w{\"a}hrend der Nutzung der Br{\"u}cke erhalten bleiben, wurden Leitf{\"a}den f{\"u}r die Pflege und Wartung sowie f{\"u}r die Br{\"u}ckenpr{\"u}fung erarbeitet. Der Beitrag gibt Einblicke in das Forschungsvorhaben und seine Resultate.}, language = {de} } @incollection{MoorkampPetersonUibel2023, author = {Moorkamp, Wilfried and Peterson, Leif Arne and Uibel, Thomas}, title = {Standardholzbr{\"u}cken f{\"u}r kommunale Geh- und Radwege}, series = {Strukturen, Formen und Prinzipien : Festschrift zum 60. Geburtstag von Univ.-Prof. Dr.-Ing. Martin Trautz}, booktitle = {Strukturen, Formen und Prinzipien : Festschrift zum 60. Geburtstag von Univ.-Prof. Dr.-Ing. Martin Trautz}, editor = {Wehren, Cedric}, publisher = {RWTH Aachen}, address = {Aachen}, isbn = {978-3-95886-500-6}, pages = {140 -- 165}, year = {2023}, language = {de} } @inproceedings{BedburMoorkampPetersonetal.2020, author = {Bedbur, Christian and Moorkamp, Wilfried and Peterson, Leif Arne and Uibel, Thomas}, title = {Holzbr{\"u}cken mit Natursteinbel{\"a}gen - Untersuchungen zur Aktivierung der Verbundwirkung}, series = {Doktorandenkolloquium Holzbau Forschung + Praxis 2020}, booktitle = {Doktorandenkolloquium Holzbau Forschung + Praxis 2020}, editor = {Kuhlmann, Ulrike}, publisher = {Universit{\"a}t Stuttgart, Institut f{\"u}r Konstruktion und Entwurf}, address = {Stuttgart}, pages = {53 -- 60}, year = {2020}, language = {de} } @book{UibelPeterson2023, author = {Uibel, Thomas and Peterson, Leif Arne}, title = {Tagungsband Aachener Holzbautagung 2023}, editor = {Uibel, Thomas and Peterson, Leif Arne}, publisher = {FH Aachen}, address = {Aachen}, issn = {2197-4489}, year = {2023}, language = {de} } @misc{FrauenrathPfeifferHezeletal.2012, author = {Frauenrath, Tobias and Pfeiffer, Harald and Hezel, Fabian and Dieringer, Matthias A. and Winter, Lukas and Gr{\"a}ßl, Andreas and Santoro, Davide and {\"O}zerdem, Celal and Renz, Wolfgang and Greiser, Andreas and Niendorf, Thoralf}, title = {Lessons learned from cardiac MRI at 7.0 T: LV function assessment at 3.0 T using local multi-channel transceiver coil arrays}, series = {2012 ISMRM Annual Meeting Proceedings}, journal = {2012 ISMRM Annual Meeting Proceedings}, issn = {1545-4428}, year = {2012}, abstract = {Cardiac MR (CMR) is of proven clinical value but also an area of vigorous ongoing research since image quality is not always exclusively defined by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Recent developments of CMR at 7.0 T have been driven by pioneering explorations into novel multichannel transmit and receive coil array technology to tackle the challenges B1+-field inhomogeneities, to offset specific-absorption rate (SAR) constraints and to reduce banding artifacts in SSFP imaging. For this study, recognition of the benefits and performance of local surface Tx/Rx-array structures recently established at 7.0 T inspired migration to 3.0 T, where RF inhomogeneities and SAR limitations encountered in routine clinical CMR, though somewhat reduced versus the 7.0 T situation, remain significant. For all these reasons, this study was designed to build and examine the feasibility of a local four channel Tx/Rx cardiac coil array for anatomical and functional cardiac imaging at 3.0 T. For comparison, a homebuilt 4 channel Rx cardiac coil array exhibiting the same geometry as the Tx/Rx coil and a Rx surface coil array were used.}, language = {en} } @misc{LindelGreiserWaxmanetal.2012, author = {Lindel, Tomasz Dawid and Greiser, Andreas and Waxman, Patrick and Dietterle, Martin and Seifert, Frank and Fontius, Ulrich and Renz, Wolfgang and Dieringer, Matthias A. and Frauenrath, Tobias and Schulz-Menger, Jeanette and Niendorf, Thoralf and Ittermann, Bernd}, title = {Cardiac CINE MRI at 7 T using a transmit array}, series = {2012 ISMRM Annual Meeting Proceedings}, journal = {2012 ISMRM Annual Meeting Proceedings}, issn = {1545-4428}, year = {2012}, abstract = {With its need for high SNR and short acquisition times, Cardiac MRI (CMR) is an intriguing target application for ultrahigh field MRI. Due to the sheer size of the upper torso, however, the known RF issues of 7T MRI are also most prominent in CMR. Recent years brought substantial progress but the full potential of the ultrahigh field for CMR is yet to be exploited. Parallel transmission (pTx) is a promising approach in this context and several groups have already reported B1 shimming for 7T CMR. In such a static pTx application amplitudes and phases of all Tx channels are adjusted individually but otherwise imaging techniques established in current clinical practice 1.5 T and 3 T are applied. More advanced forms of pTx as spatially selective excitation (SSE) using Transmit SENSE promise additional benefits like faster imaging with reduced fields of view or improved SAR control. SSE requires the full dynamic capabilities of pTx, however, and for the majority of today's implemented pTx hardware the internal synchronization of the Tx array does not easily permit external triggering as needed for CMR. Here we report a software solution to this problem and demonstrate the feasibility of CINE CMR at 7 T using a Tx array.}, language = {en} } @phdthesis{Buedenbender2012, author = {B{\"u}denbender, Martin}, title = {Entflechtungskonzepte f{\"u}r Strom{\"u}bertragungsnetze : ein {\"o}konomischer Vergleich}, series = {M{\"u}nstersche Schriften zur Kooperation ; Bd. 101}, journal = {M{\"u}nstersche Schriften zur Kooperation ; Bd. 101}, publisher = {Shaker}, address = {D{\"u}ren}, isbn = {978-3-8440-1460-0}, pages = {XVII, 401 S. : Ill., graph. Darst.}, year = {2012}, abstract = {Netzsektoren und deren ad{\"a}quate Regulierung sind ein sehr relevantes und aktuelles Thema. Dies gilt sowohl f{\"u}r die {\"o}konomische Theorie, die sich sehr intensiv damit auseinandersetzt und in den letzten Jahrzehnten zahlreiche neue Erkenntnisse gewonnen hat. Es gilt ebenso f{\"u}r die Politik, in der Regulierungsfragen kontrovers diskutiert werden und dies nicht nur unter {\"o}konomischen Gesichtspunkten. Es gilt selbstverst{\"a}ndlich f{\"u}r die regulierten Unternehmen selbst, deren T{\"a}tigkeit durch die staatlichen Regulierungsvorgaben markant beeinflusst wird. Nicht nur die konkreten Inhalte der Regulierungsregime sowie die verbleibenden Freiheitsgrade in der Ausgestaltung sind von Bedeutung, sondern ebenso die Umsetzung durch die Regulierungsbeh{\"o}rden. All dies gilt f{\"u}r den Strommarkt und seinen regulatorischen Hintergrund in besonderer Weise. Die Entflechtung der Strom{\"u}bertragungsnetze von der Stromproduktion und damit die Vorgaben f{\"u}r die Organisation der Wertsch{\"o}pfungsketten in den Elektrizit{\"a}tsunternehmen sind seit dem Beginn des europ{\"a}ischen Liberalisierungsprozesses der Stromm{\"a}rkte ein wichtiges und kontrovers diskutiertes Regulierungselement. Den Fokus bildet das vertikale Unbundling, das letztlich die Diskriminierung von Wettbewerbern durch Anbieter mit aggregierten Wertsch{\"o}pfungsketten verhindern soll, indem diese gezwungen werden, ihren "Netzteil" anders zu organisieren oder zu verkaufen. Den Mitgliedsstaaten blieben Freir{\"a}ume in der Ausgestaltung, die in Deutschland erst vor kurzem konkretisiert wurden, und die f{\"u}r die regulierten Unternehmen die Nutzung eines Wahlrechts beinhalten. Der wirtschaftspolitischen folgt nun eine unternehmerische Abw{\"a}gungsentscheidung.}, language = {de} }