@inproceedings{AridaKloockSchoening2006, author = {Arida, Hassan A. and Kloock, Joachim P. and Sch{\"o}ning, Michael Josef}, title = {Novel organic membrane-based thin-film microsensors for the determination of heavy metal cations}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1545}, year = {2006}, abstract = {A first step towards the fabrication and electrochemical evaluation of thin-film microsensors based on organic PVC membranes for the determination of Hg(II), Cd(II), Pb(II) and Cu(II) ions in solutions has been realised. The membrane-coating mixture used in the preparation of this new type of microsensors is incorporating PVC as supporting matrix, o-nitrophenyloctylether (o-NPOE) as solvent mediator and a recently synthesized Hg[dimethylglyoxime(phene)]2+ and Bis-(4-hydroxyacetophenone)-ethylenediamine as electroactive materials for Hg(II) and Cd(II), respectively. A set of three commercialised ionophores for Cd(II), Pb(II) and Cu(II) has been also used for comparison. Thin-film microsensors based on these membranes showed a Nernstian response of slope (26-30 mV/dec.) for the respective tested cations. The potentiometric response characteristics (linear range, pH range, detection limit and response time) are comparable with those obtained by conventional membranes as well as coated wire electrodes prepared from the same membrane. The realisation of the new organic membrane-based thin-film microsensors overcomes the problem of an insufficient selectivity of solid-state-based thinfilm sensors.}, subject = {Biosensor}, language = {en} } @inproceedings{BarekFischerNavratiletal.2006, author = {Barek, Jiri and Fischer, Jan and Navratil, Tomas and Peckova, Karolina and Yosypchuk, Bogdan}, title = {Silver solid amalgam electrodes as sensors for chemical carcinogens}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1554}, year = {2006}, abstract = {The applicability of differential pulse voltammetry (DPV) and adsorptive stripping voltammetry (AdSV) at a non-toxic meniscus-modified silver solid amalgam electrode (m-AgSAE) for the determination of trace amounts of genotoxic substances was demonstrated on the determination of micromolar and submicromolar concentrations of 3-nitrofluoranthene using methanol - 0.01 mol L-1 NaOH (9:1) mixture as a base electrolyte and of Ostazine Orange using 0.01 mol L-1 NaOH as a base electrolyte.}, subject = {Biosensor}, language = {en} } @inproceedings{BaronasIvanauskasKulys2006, author = {Baronas, Romas and Ivanauskas, Feliksas and Kulys, Juozas}, title = {Mathematical modeling of biosensors based on an array of enzyme microreactors}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1569}, year = {2006}, abstract = {This paper presents a two-dimensional-in-space mathematical model of biosensors based on an array of enzyme microreactors immobilised on a single electrode. The modeling system acts under amperometric conditions. The microreactors were modeled by particles and by strips. The model is based on the diffusion equations containing a nonlinear term related to the Michaelis-Menten kinetics of the enzymatic reaction. The model involves three regions: an array of enzyme microreactors where enzyme reaction as well as mass transport by diffusion takes place, a diffusion limiting region where only the diffusion takes place, and a convective region, where the analyte concentration is maintained constant. Using computer simulation, the influence of the geometry of the microreactors and of the diffusion region on the biosensor response was investigated. The digital simulation was carried out using the finite difference technique.}, subject = {Biosensor}, language = {en} } @inproceedings{Wessling2006, author = {Weßling, Matthias}, title = {Como motivar a si mesmo e aos outros - o valor dos 16 Motivos Vitais para Lideran{\c{c}}a}, year = {2006}, abstract = {O Perfil Reiss apresenta no resultado uma vis{\~a}o da estrutura dos motivos e impulsos de uma pessoa. O ponto de sa{\´i}da para a an{\´a}lise do resultado {\´e} o conhecimento de que os motivos vitais (= valores e metas de sobreviv{\^e}ncia) formam a moldura, na qual as compet{\^e}ncias e capacidades que uma pessoa possui possam se desabrochar de forma ideal. A partir desse princ{\´i}pio, n{\~a}o existe no Perfil Reiss nenhum resultado que se possa classificar como correto ou falso, nem como bom ou mau. Uma compara{\c{c}}{\~a}o entre o resultado do Perfil Reiss e o conte{\´u}do de uma atividade apresentada ou ambicionada d{\´a} informa{\c{c}}{\~a}o sobre at{\´e} que ponto a capacidade de rendimento de uma pessoa nessa posi{\c{c}}{\~a}o pode vir ou vir{\´a} a se desenvolver por um longo tempo.}, subject = {F{\"u}hrung}, language = {es} } @techreport{Wessling2006, type = {Working Paper}, author = {Weßling, Matthias}, title = {O Perfil Reiss: Conceito scientifico e conclus{\~o}es da pesquisa, aplica{\c{c}}{\~o}es exemplaricas e conseq{\"u}{\^e}ncias pr{\´a}ticas}, year = {2006}, abstract = {Para Reiss, a avalia{\c{c}}{\~a}o de cada um dos 16 motivos vitais {\´e} a chave para n{\~a}o s{\´o} entender o comportamento humano, como tamb{\´e}m para poder prev{\^e}-lo. Tal previs{\~a}o {\´e} tamb{\´e}m a meta de cada ci{\^e}ncia. Quando se quer saber a rea{\c{c}}{\~a}o das pessoas, precisa-se primeiro descobrir, o que as pessoas realmente querem - e, ent{\~a}o prever, que elas satisfar{\~a}o esses desejos e necessidades em suas a{\c{c}}{\~o}es. As chances, que o Perfil Reiss oferece, resultam entre outras tamb{\´e}m, que aqui {\´e} poss{\´i}vel pela primeira vez uma individualiza{\c{c}}{\~a}o total. Cerca de 6 bilh{\~o}es de perfis individuais podem ser apresentados com o Perfil Reiss. Na combina{\c{c}}{\~a}o correta da forma{\c{c}}{\~a}o e utiliza{\c{c}}{\~a}o da tipologia de um lado e da individualidade da conclus{\~a}o de outro lado, est{\´a} a for{\c{c}}a positiva desse instrumento.}, subject = {Motivation}, language = {pt} } @inproceedings{LeiMulchandaniChenetal.2006, author = {Lei, Yu and Mulchandani, Priti and Chen, Wilfred and Mulchandani, Ashok}, title = {Biosensor for direct determination of fenitrothion and EPN using recombinant Pseudomonas putida JS444 with surface expressed organophosphorus hydrolase. 1. modified clark oxygen electrode}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1573}, year = {2006}, abstract = {This paper reports a first microbial biosensor for rapid and cost-effective determination of organophosphorus pesticides fenitrothion and EPN. The biosensor consisted of recombinant PNP-degrading/oxidizing bacteria Pseudomonas putida JS444 anchoring and displaying organophosphorus hydrolase (OPH) on its cell surface as biological sensing element and a dissolved oxygen electrode as the transducer. Surfaceexpressed OPH catalyzed the hydrolysis of fenitrothion and EPN to release 3-methyl-4-nitrophenol and p-nitrophenol, respectively, which were oxidized by the enzymatic machinery of Pseudomonas putida JS444 to carbon dioxide while consuming oxygen, which was measured and correlated to the concentration of organophosphates. Under the optimum operating conditions, the biosensor was able to measure as low as 277 ppb of fenitrothion and 1.6 ppm of EPN without interference from phenolic compounds and other commonly used pesticides such as carbamate pesticides, triazine herbicides and organophosphate pesticides without nitrophenyl substituent. The applicability of the biosensor to lake water was also demonstrated.}, subject = {Biosensor}, language = {en} } @inproceedings{BuehrigPolaczekRoethBaumeisteretal.2006, author = {B{\"u}hrig-Polaczek, Andreas and R{\"o}th, Thilo and Baumeister, E. and Nowack, N. and S{\"u}ßmann, Torsten}, title = {Hybride Leichtbaustrukturen in Stahlblech-Leichtmetall Verbundguss}, year = {2006}, abstract = {Stahl-Leichtmetall-Hybride mit hohen Leistungspotentialen k{\"o}nnen heute wirtschaftlich abgebildet werden und eignen sich m{\"o}glicherweise auch zum Einsatz in Fahrzeugkarosserien}, subject = {Karosseriebau}, language = {de} } @misc{HoettgesCordesWirtzetal.2006, author = {H{\"o}ttges, J{\"o}rg and Cordes, J{\"u}rgen and Wirtz, Dominika and Moers, Monika and Gehlen, Tanja and Aldenhoven, Frederick}, title = {E-Learning AutoCAD}, year = {2006}, abstract = {Schrittweise Einf{\"u}hrung in die Welt des AutoCAD. Nach jedem Abschnitt besteht die M{\"o}glichkeit, das neue Wissen direkt anzuwenden. Mit Wissenspr{\"u}fungen und {\"U}bungen nach jedem Kapitel. (Modul wird noch {\"u}berarbeitet) 1. Der Anfang mit AutoCAD 2. Grundlagen zur Anfertigung einer Zeichnung 3. Layer 4. Texte und Bemaßung 5. Weiterf{\"u}hrende Zeichenwerkzeuge 6. Layout und Plotten}, subject = {CAD}, language = {de} } @misc{HoettgesCordesWirtzetal.2006, author = {H{\"o}ttges, J{\"o}rg and Cordes, J{\"u}rgen and Wirtz, Dominika and Moers, Monika and Gehlen, Tanja and Aldenhoven, Frederick}, title = {E-Learning Access}, year = {2006}, abstract = {Schrittweise Einf{\"u}hrung in Access. Nach jedem Abschnitt besteht die M{\"o}glichkeit, das neue Wissen direkt anzuwenden. Mit Wissenspr{\"u}fungen und {\"U}bungen nach jedem Kapitel. 1. Grundbegriffe aus der Datenbank 2. Eine Datenbank planen 3. Tabellen erstellen und bearbeiten 4. Abfragen erstellen und bearbeiten 5. Formulare - Tuning f{\"u}r die Daten 6. Berichte - echt einfach}, subject = {ACCESS 2003}, language = {de} } @inproceedings{Staat2006, author = {Staat, Manfred}, title = {Problems and chances for probabilistic fracture mechanics in the analysis of steel pressure boundary reliability. - {\"U}berarb. Ausg.}, year = {2006}, abstract = {In: Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in J{\"u}lich, 21-24 November 1994. - Vienna , 1996. - Seite: 43 - 55 IAEA-TECDOC-920 Abstract: It is shown that the difficulty for probabilistic fracture mechanics (PFM) is the general problem of the high reliability of a small population. There is no way around the problem as yet. Therefore what PFM can contribute to the reliability of steel pressure boundaries is demon­strated with the example of a typical reactor pressure vessel and critically discussed. Although no method is distinguishable that could give exact failure probabilities, PFM has several addi­tional chances. Upper limits for failure probability may be obtained together with trends for design and operating conditions. Further, PFM can identify the most sensitive parameters, improved control of which would increase reliability. Thus PFM should play a vital role in the analysis of steel pressure boundaries despite all shortcomings.}, subject = {Bruchmechanik}, language = {en} }