@article{AbouzarPedrazaSchoeningetal.2010, author = {Abouzar, Maryam H. and Pedraza, A. M. and Sch{\"o}ning, Michael Josef and Poghossian, Arshak}, title = {Label-free DNA hybridization and denaturation detection by means of field-effect nanoplate SOI capacitors functionalized with gold nanoparticles}, series = {Procedia Engineering. 5 (2010)}, journal = {Procedia Engineering. 5 (2010)}, isbn = {1877-7058}, pages = {918 -- 921}, year = {2010}, language = {en} } @article{AbouzarPoghossianSiqueiraetal.2010, author = {Abouzar, Maryam H. and Poghossian, Arshak and Siqueira, Jos{\´e} R. Jr. and Oliveira, Osvaldo N. Jr. and Moritz, Werner and Sch{\"o}ning, Michael Josef}, title = {Capacitive electrolyte-insulator-semiconductor structures functionalised with a polyelectrolyte/enzyme multilayer: New strategy for enhanced field-effect biosensing}, series = {Physica Status Solidi (A). 207 (2010), H. 4}, journal = {Physica Status Solidi (A). 207 (2010), H. 4}, isbn = {1862-6300}, pages = {884 -- 890}, year = {2010}, language = {en} } @article{AggeloussisGiannakouAlbrachtetal.2010, author = {Aggeloussis, Nickos and Giannakou, Erasmia and Albracht, Kirsten and Arampatzis, Adamantios}, title = {Reproducibility of fascicle length and pennation angle of gastrocnemius medialis in human gait in vivo}, series = {Gait and Posture}, volume = {31}, journal = {Gait and Posture}, number = {1}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0966-6362}, doi = {10.1016/j.gaitpost.2009.08.249}, pages = {73 -- 77}, year = {2010}, abstract = {The purpose of the current study was to examine the reproducibility of fascicle length and pennation angle of gastrocnemius medialis while human walking. To the best of our knowledge, this is the first study of the reproducibility of fascicle length and pennation angle of gastrocnemius medialis in vivo during human gait. Twelve males performed 10 gait trials on a treadmill, in 2 separate days. B-mode ultrasonography, with the ultrasound probe firmly adjusted in the transverse and frontal planes using a special cast, was used to measure the fascicle length and the pennation angle of the gastrocnemius medialis (GM). A Vicon 624 system with three cameras operating at 120 Hz was also used to record the ankle and knee joint angles. The results showed that measurements of fascicle length and pennation angle showed high reproducibility during the gait cycle, both within the same day and between different days. Moreover, the root mean square differences between the repeated waveforms of both variables were very small, compared with their ranges (fascicle length: RMS = ∼3 mm, range: 38-63 mm; pennation angle: RMS = ∼1.5°, range: 22-32°). However, their reproducibility was lower compared to the joint angles. It was found that representative data have to be derived by a wide number of gait trials (fascicle length ∼six trials, pennation angle more than 10 trials), to assure the reliability of the fascicle length and pennation angle in human gait.}, language = {en} } @article{AhmedReisgenSchleseretal.2010, author = {Ahmed, Essam and Reisgen, Uwe and Schleser, Markus and Mokrov, Oleg}, title = {On formability of tailor laser welded blanks of DP/TRIP steel sheets}, series = {Science and technology of welding and joining}, volume = {15}, journal = {Science and technology of welding and joining}, number = {5}, publisher = {Maney}, address = {Leeds}, issn = {1743-2936}, doi = {10.1179/136217110X12731414739754}, pages = {337 -- 342}, year = {2010}, abstract = {This paper aims to evaluate the formability of tailor welded blanks of dual phase (DP600)/transformation induced plasticity (TRIP700) steel sheets. In this work, bead on plate butt joints of 2·5 mm DP600 and 1·2 mm TRIP700 steel sheets were performed using CO2 laser beam welding. Microhardness measurements and transverse tensile testing were carried out to characterise the welds. The formability of base metals and welds were investigated by standard Erichsen test. In a perpendicular tensile test to the weld line, all specimens were fractured at the TRIP base metal, and the strengths were somewhat higher than those of base metal. There was a significant reduction in formability caused by welding of the DP600/TRIP700 steel sheets, and the formability increased with increasing welding speed.}, language = {en} } @article{AkimbekovZhubanovaMansurovetal.2010, author = {Akimbekov, N. Sh. and Zhubanova, A. A. and Mansurov, Z. A. and Digel, Ilya and Artmann, Gerhard and Temiz Artmann, Ayseg{\"u}l}, title = {Use of Carbonized Rise Shell for the local treatment of wounds}, series = {Eurasian ChemTech Journal}, volume = {12}, journal = {Eurasian ChemTech Journal}, number = {2}, publisher = {Institute of Combustion Problems}, address = {Almaty}, issn = {2522-4867}, doi = {10.18321/ectj35}, pages = {133 -- 138}, year = {2010}, abstract = {On the model of musculocutaneous wound in rats, the effect of applicative sorption by carbonized rise shell (CRS) on the healing of festering wound was studied. It has been shown, that cytological changes end with rapid scar formation. The use of CRS at the period of severe purulent wound contributes to its favorable course, prevents the development of complications of the animals from sepsis.}, language = {en} } @article{AlexopoulosHoffschmidt2010, author = {Alexopoulos, Spiros and Hoffschmidt, Bernhard}, title = {Solar tower power plant in Germany and future perspectives of the development of the technology in Greece and Cyprus}, series = {Renewable Energy . 35 (2010), H. 7}, journal = {Renewable Energy . 35 (2010), H. 7}, isbn = {0960-1481}, pages = {1352 -- 1356}, year = {2010}, language = {en} } @article{AlexopoulosHoffschmidt2010, author = {Alexopoulos, Spiros and Hoffschmidt, Bernhard}, title = {Solarthermische Kraftwerke mit thermischen Speichern}, series = {Chemie Ingenieur Technik. 82 (2010), H. 9}, journal = {Chemie Ingenieur Technik. 82 (2010), H. 9}, isbn = {1522-2640}, pages = {1606 -- 1606}, year = {2010}, language = {de} } @article{ArampatzisPeperBierbaumetal.2010, author = {Arampatzis, Adamantios and Peper, Andreas and Bierbaum, Stefanie and Albracht, Kirsten}, title = {Plasticity of human Achilles tendon mechanical and morphological properties in response to cyclic strain}, series = {Journal of Biomechanics}, volume = {43}, journal = {Journal of Biomechanics}, number = {16}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0021-9290}, doi = {10.1016/j.jbiomech.2010.08.014}, pages = {3073 -- 3079}, year = {2010}, abstract = {The purpose of the current study in combination with our previous published data (Arampatzis et al., 2007) was to examine the effects of a controlled modulation of strain magnitude and strain frequency applied to the Achilles tendon on the plasticity of tendon mechanical and morphological properties. Eleven male adults (23.9±2.2 yr) participated in the study. The participants exercised one leg at low magnitude tendon strain (2.97±0.47\%), and the other leg at high tendon strain magnitude (4.72±1.08\%) of similar frequency (0.5 Hz, 1 s loading, 1 s relaxation) and exercise volume (integral of the plantar flexion moment over time) for 14 weeks, 4 days per week, 5 sets per session. The exercise volume was similar to the intervention of our earlier study (0.17 Hz frequency; 3 s loading, 3 s relaxation) allowing a direct comparison of the results. Before and after the intervention ankle joint moment has been measured by a dynamometer, tendon-aponeurosis elongation by ultrasound and cross-sectional area of the Achilles tendon by magnet resonance images (MRI). We found a decrease in strain at a given tendon force, an increase in tendon-aponeurosis stiffness and tendon elastic modulus of the Achilles tendon only in the leg exercised at high strain magnitude. The cross-sectional area (CSA) of the Achilles tendon did not show any statistically significant (P>0.05) differences to the pre-exercise values in both legs. The results indicate a superior improvement in tendon properties (stiffness, elastic modulus and CSA) at the low frequency (0.17 Hz) compared to the high strain frequency (0.5 Hz) protocol. These findings provide evidence that the strain magnitude applied to the Achilles tendon should exceed the value, which occurs during habitual activities to trigger adaptational effects and that higher tendon strain duration per contraction leads to superior tendon adaptational responses.}, language = {en} } @article{BalakrishnanAndreiSelmerSelmeretal.2010, author = {Balakrishnan, Karthikeyan and Andrei-Selmer, Luminita-Cornelia and Selmer, Thorsten and Bacher, Michael and Dodel, Richard}, title = {Comparison of Intravenous Immunoglobulins for Naturally Occurring Autoantibodies against Amyloid-β}, series = {Journal of Alzheimer's Disease}, volume = {20}, journal = {Journal of Alzheimer's Disease}, number = {1}, isbn = {1387-2877}, pages = {135 -- 143}, year = {2010}, language = {en} } @article{BarbazanHagenbachPaulssenetal.2010, author = {Barbaz{\´a}n, Paula and Hagenbach, Adelheid and Paulßen, Elisabeth and Abram, Ulrich and Carballo, Rosa and Rodriguez-Hermida, Sabina and V{\´a}zquez-L{\´o}pez, Ezequiel M.}, title = {Tricarbonyl Rhenium(I) and Technetium(I) Complexes with Hydrazones Derived from 4,5-Diazafluoren-9-one and 1,10-Phenanthroline-5,6-dione}, series = {European Journal of Inorganic Chemistry}, journal = {European Journal of Inorganic Chemistry}, number = {29}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1099-0682}, doi = {10.1002/ejic.201000522}, pages = {4622 -- 4630}, year = {2010}, abstract = {Tricarbonylrhenium(I) and -technetium(I) halide (halide = Cl and Br) complexes of ligands derived from 4,5-diazafluoren-9-one (df) and 1,10-phenanthroline-5,6-dione (phen) derivatives of benzoic and 2-hydroxybenzoic acid hydrazides have been prepared. The complexes have been characterized by elemental analysis, MS, IR, 1H NMR and absorption and emission UV/Vis spectroscopic methods. The metal centres (ReI and TcI) are coordinated through the nitrogen imine atoms and establish five-membered chelate rings, whereas the hydrazone groups stand uncoordinated. The 1H NMR spectra suggest the same behaviour in solution on the basis of only marginal variations in the chemical shifts of the hydrazine protons.}, language = {en} }