@article{ButenwegMarinkovic2018, author = {Butenweg, Christoph and Marinkovic, Marko}, title = {Erdbebensicherer Anschluss von Ausfachungsmauerwerk in Stahlbetonrahmentragwerken mit Entkopplungselementen}, series = {Bauingenieur}, volume = {93}, journal = {Bauingenieur}, number = {9}, publisher = {VDI Fachmedien}, address = {D{\"u}sseldorf}, issn = {0005-6650}, pages = {333 -- 341}, year = {2018}, abstract = {Stahlbetonrahmentragwerke mit Mauerwerksausfachungen weisen nach Erdbebenereignissen h{\"a}ufig schwere Sch{\"a}den auf, da die Ausfachungen ohne weitere konstruktive Maßnahmen mit vollem Kontakt zum Stahlbetonrahmen eingemauert werden. Durch die unplanm{\"a}ßige Beteiligung am horizontalen Lastabtrag erfahren die Ausfachungen Belastungen in Wandebene und beeinflussen das globale Schwingungsverhalten der Rahmentragwerke. In Kombination mit den gleichzeitig auftretenden seismischen Tr{\"a}gheitskr{\"a}ften senkrecht zur Wand f{\"u}hrt dies in vielen F{\"a}llen zu einem Versagen der mit niedrigen Festigkeiten ausgef{\"u}hrten Ausfachungen. Dies war der Anlass in dem europ{\"a}ischen Forschungsprojekt INSYSME ein Entkopplungssystem zu entwickeln, mit dem Rahmen und Ausfachung durch ein spezielles Profil aus Elastomeren entkoppelt werden. Das Profil erm{\"o}glicht Relativverschiebungen zwischen Rahmen und Ausfachung und stellt gleichzeitig die Aufnahme von Belastungen senkrecht zur Wand sicher. Der Beitrag erl{\"a}utert zun{\"a}chst den Aufbau des Systems und gibt einen {\"U}berblick {\"u}ber die in Kleinbauteilversuchen ermittelten Tragf{\"a}higkeiten. Zudem werden experimentelle Untersuchungen an mit hochw{\"a}rmed{\"a}mmenden Mauerziegeln ausgefachten Stahlbetonrahmen mit und ohne Entkopplungssystem f{\"u}r getrennte und kombinierte Belastungen in und senkrecht zur Wandebene vorgestellt. Auf Grundlage einer Versuchsauswertung und eines Ergebnisvergleichs werden Wirkungsweise und Effektivit{\"a}t des entwickelten Entkopplungssystems demonstriert.}, language = {de} } @article{ButenwegMarinkovićFehlingetal.2018, author = {Butenweg, Christoph and Marinković, Marko and Fehling, Ekkehard and Pfetzing, Thomas}, title = {Stahlbetonrahmentragwerke mit Ausfachungen aus Mauerwerk unter kombinierten seismischen Belastungen in und senkrecht zur Wandebene}, series = {Bauingenieur}, volume = {93}, journal = {Bauingenieur}, publisher = {VDI Fachmedien}, address = {D{\"u}sseldorf}, isbn = {0005-6650}, pages = {2 -- 10}, year = {2018}, language = {de} } @article{ButenwegMarinkovićKubalskietal.2018, author = {Butenweg, Christoph and Marinković, Marko and Kubalski, Thomas and Fehling, Ekkehard and Pfetzing, Thomas and Meyer, Udo}, title = {Auslegung von Stahlbetonrahmentragwerken mit Ausfachungen aus Ziegelmauerwerk (Teil 1)}, series = {Ziegelindustrie international : ZI = Brick and tile industry international}, journal = {Ziegelindustrie international : ZI = Brick and tile industry international}, number = {4}, editor = {Voss, Michael}, publisher = {Bauverlag BV GmbH}, address = {G{\"u}tersloh}, issn = {0341-0552}, pages = {30 -- 39}, year = {2018}, abstract = {Im Rahmen des europ{\"a}ischen Verbundprojekts INSYSME wurden von den deutschen Partnern die Systeme IMES und INODIS zur Verbesserung des seismischen Verhaltens von ausgefachten Stahlbetonrahmen entwickelt. Ziel beider Systeme ist es, Stahlbetonrahmen und Ausfachung zu entkoppeln, anstatt die Tragf{\"a}higkeit durch aufwendige und kostspielige zus{\"a}tzliche Bewehrungseinlagen zu erh{\"o}hen. Erste Ergebnisse des Systems IMES f{\"u}r Belastungen in und senkrecht zu der Wandebene werden vorgestellt.}, language = {de} } @article{ButenwegMarinkovićKubalskietal.2018, author = {Butenweg, Christoph and Marinković, Marko and Kubalski, Thomas and Fehling, Ekkehard and Pfetzing, Thomas and Meyer, Udo}, title = {Auslegung von Stahlbetonrahmentragwerken mit Ausfachungen aus Ziegelmauerwerk (Teil 2)}, series = {Ziegelindustrie international : ZI = Brick and tile industry international}, journal = {Ziegelindustrie international : ZI = Brick and tile industry international}, number = {6}, editor = {Voss, Michael}, publisher = {Bauverlag BV GmbH}, address = {G{\"u}tersloh}, issn = {0341-0552}, pages = {24 -- 43}, year = {2018}, abstract = {Im Rahmen des europ{\"a}ischen Verbundprojekts INSYSME wurden von den deutschen Partnern die Systeme IMES und INODIS zur Verbesserung des seismischen Verhaltens von ausgefachten Stahlbetonrahmen entwickelt. Ziel beider Systeme ist es, Stahlbetonrahmen und Ausfachung zu entkoppeln, anstatt die Tragf{\"a}higkeit durch aufwendige und kostspielige zus{\"a}tzliche Bewehrungseinlagen zu erh{\"o}hen. Erste Ergebnisse des Systems IMES f{\"u}r Belastungen in und senkrecht zu der Wandebene werden vorgestellt.}, language = {de} } @article{CiritsisHorbachStaatetal.2018, author = {Ciritsis, Alexander and Horbach, Andreas and Staat, Manfred and Kuhl, Christiane K. and Kraemer, Nils Andreas}, title = {Porosity and tissue integration of elastic mesh implants evaluated in vitro and in vivo}, series = {Journal of Biomedical Materials Research: Part B: Applied Biomaterials}, volume = {106}, journal = {Journal of Biomedical Materials Research: Part B: Applied Biomaterials}, number = {2}, publisher = {Wiley}, address = {New York, NY}, issn = {1552-4981}, doi = {10.1002/jbm.b.33877}, pages = {827 -- 833}, year = {2018}, abstract = {Purpose In vivo, a loss of mesh porosity triggers scar tissue formation and restricts functionality. The purpose of this study was to evaluate the properties and configuration changes as mesh deformation and mesh shrinkage of a soft mesh implant compared with a conventional stiff mesh implant in vitro and in a porcine model. Material and Methods Tensile tests and digital image correlation were used to determine the textile porosity for both mesh types in vitro. A group of three pigs each were treated with magnetic resonance imaging (MRI) visible conventional stiff polyvinylidene fluoride meshes (PVDF) or with soft thermoplastic polyurethane meshes (TPU) (FEG Textiltechnik mbH, Aachen, Germany), respectively. MRI was performed with a pneumoperitoneum at a pressure of 0 and 15 mmHg, which resulted in bulging of the abdomen. The mesh-induced signal voids were semiautomatically segmented and the mesh areas were determined. With the deformations assessed in both mesh types at both pressure conditions, the porosity change of the meshes after 8 weeks of ingrowth was calculated as an indicator of preserved elastic properties. The explanted specimens were examined histologically for the maturity of the scar (collagen I/III ratio). Results In TPU, the in vitro porosity increased constantly, in PVDF, a loss of porosity was observed under mild stresses. In vivo, the mean mesh areas of TPU were 206.8 cm2 (± 5.7 cm2) at 0 mmHg pneumoperitoneum and 274.6 cm2 (± 5.2 cm2) at 15 mmHg; for PVDF the mean areas were 205.5 cm2 (± 8.8 cm2) and 221.5 cm2 (± 11.8 cm2), respectively. The pneumoperitoneum-induced pressure increase resulted in a calculated porosity increase of 8.4\% for TPU and of 1.2\% for PVDF. The mean collagen I/III ratio was 8.7 (± 0.5) for TPU and 4.7 (± 0.7) for PVDF. Conclusion The elastic properties of TPU mesh implants result in improved tissue integration compared to conventional PVDF meshes, and they adapt more efficiently to the abdominal wall. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 827-833, 2018.}, language = {en} } @article{ConzenAlbannaWeissetal.2018, author = {Conzen, Catharina and Albanna, Walid and Weiss, Miriam and K{\"u}rten, David and Vilser, Walthard and Kotliar, Konstantin and Z{\"a}ske, Charlotte and Clusmann, Hans and Schubert, Gerrit Alexander}, title = {Vasoconstriction and Impairment of Neurovascular Coupling after Subarachnoid Hemorrhage: a Descriptive Analysis of Retinal Changes}, series = {Translational Stroke Research}, journal = {Translational Stroke Research}, number = {9}, publisher = {Springer Nature}, address = {Cham}, issn = {1868-601X}, doi = {10.1007/s12975-017-0585-8}, pages = {284 -- 293}, year = {2018}, abstract = {Impaired cerebral autoregulation and neurovascular coupling (NVC) contribute to delayed cerebral ischemia after subarachnoid hemorrhage (SAH). Retinal vessel analysis (RVA) allows non-invasive assessment of vessel dimension and NVC hereby demonstrating a predictive value in the context of various neurovascular diseases. Using RVA as a translational approach, we aimed to assess the retinal vessels in patients with SAH. RVA was performed prospectively in 24 patients with acute SAH (group A: day 5-14), in 11 patients 3 months after ictus (group B: day 90 ± 35), and in 35 age-matched healthy controls (group C). Data was acquired using a Retinal Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and NVC using flicker-light excitation. Diameter of retinal vessels—central retinal arteriolar and venular equivalent—was significantly reduced in the acute phase (p < 0.001) with gradual improvement in group B (p < 0.05). Arterial NVC of group A was significantly impaired with diminished dilatation (p < 0.001) and reduced area under the curve (p < 0.01) when compared to group C. Group B showed persistent prolonged latency of arterial dilation (p < 0.05). Venous NVC was significantly delayed after SAH compared to group C (A p < 0.001; B p < 0.05). To our knowledge, this is the first clinical study to document retinal vasoconstriction and impairment of NVC in patients with SAH. Using non-invasive RVA as a translational approach, characteristic patterns of compromise were detected for the arterial and venous compartment of the neurovascular unit in a time-dependent fashion. Recruitment will continue to facilitate a correlation analysis with clinical course and outcome.}, language = {en} } @article{DantismRoehlenWagneretal.2018, author = {Dantism, Shahriar and R{\"o}hlen, Desiree and Wagner, Torsten and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Optimization of Cell-Based Multi-Chamber LAPS Measurements Utilizing FPGA-Controlled Laser-Diode Modules}, series = {physica status solidi a : applications and materials sciences}, volume = {215}, journal = {physica status solidi a : applications and materials sciences}, number = {15}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201800058}, pages = {Article number 1800058}, year = {2018}, abstract = {A light-addressable potentiometric sensor (LAPS) is a field-effect-based potentiometric device, which detects concentration changes of an analyte solution on the sensor surface in a spatially resolved way. It uses a light source to generate electron-hole pairs inside the semiconductor, which are separated in the depletion region due to an applied bias voltage across the sensor structure and hence, a surface-potential-dependent photocurrent can be read out. However, depending on the beam angle of the light source, scattering effects can occur, which influence the recorded signal in LAPS-based differential measurements. To solve this problem, a novel illumination unit based on a field programmable gate array (FPGA) consisting of 16 small-sized tunable infrared laser-diode modules (LDMs) is developed. Due to the improved focus of the LDMs with a beam angle of only 2 mrad, undesirable scattering effects are minimized. Escherichia coli (E. coli) K12 bacteria are used as a test microorganism to study the extracellular acidification on the sensor surface. Furthermore, a salt bridge chamber is built up and integrated with the LAPS system enabling multi-chamber differential measurements with a single Ag/AgCl reference electrode.}, language = {en} } @article{deBloisdeZangerPaulssenetal.2018, author = {de Blois, Eric and de Zanger, Rory M. S. and Paulßen, Elisabeth and Sze Chan, Ho and Breeman, Wouter A. P.}, title = {Semi-automated system for concentrating 68Ga-eluate to obtain high molar and volume concentration of 68Ga-Radiopharmaca for preclinical applications}, series = {Nuclear Medicine and Biology}, volume = {64-65}, journal = {Nuclear Medicine and Biology}, publisher = {Elsevier}, address = {Amsterdam}, doi = {10.1016/j.nucmedbio.2018.06.006}, pages = {16 -- 21}, year = {2018}, abstract = {68Ga-radiopharmaceuticals are common in the field of Nuclear Medicine to visualize receptor-mediated processes. In contrast to straightforward labeling procedures for clinical applications, preclinical in vitro and in vivo applications are hampered for reasons like e.g. volume restriction, activity concentration, molar activity and osmolality. Therefore, we developed a semiautomatic system specifically to overcome these problems. A difficulty appeared unexpectedly, as intrinsic trace metals derived from eluate (Zn, Fe and Cu) are concentrated as well in amounts that influence radiochemical yield and thus lower molar activity.}, language = {en} } @article{DigelWehlitzKayseretal.2018, author = {Digel, Ilya and Wehlitz, V. and Kayser, Peter and Figiel-Lange, A. and Bassam, R. and Rundstedt, F. von}, title = {Suspension depletion approach for exemption of infected Solanum jasminoides cells from pospiviroids}, series = {Plant Pathology}, volume = {67}, journal = {Plant Pathology}, number = {2}, publisher = {Wiley}, address = {Oxford}, issn = {1365-3059}, doi = {10.1111/ppa.12750}, pages = {358 -- 365}, year = {2018}, abstract = {Despite numerous studies, viroid elimination from infected plants remains a very challenging task. This study introduces for the first time a novel 'suspension depletion' approach for exemption of Solanum jasminoides plants from viroids. The proposed method implies initial establishment of suspension cultures of the infected plant cells. The suspended cells were then physically treated (mild thermotherapy, 33 °C), which presumably delayed the replication of the viroid. The viroid concentration in the treated biomass was monitored weekly using pospiviroid-specific PCR. After 10-12 weeks of continuous treatment, a sufficient decrease in viroid concentration was observed such that the infection became undetectable by PCR. The treated single cells then gave rise to microcolonies on a solid culture medium and the obtained viroid-negative clones were further promoted to regenerate into viroid-free plants. Three years of accumulated experimental data suggests feasibility, broad applicability, and good efficacy of the proposed approach.}, language = {en} } @article{DitzhausGaigall2018, author = {Ditzhaus, Marc and Gaigall, Daniel}, title = {A consistent goodness-of-fit test for huge dimensional and functional data}, series = {Journal of Nonparametric Statistics}, volume = {30}, journal = {Journal of Nonparametric Statistics}, number = {4}, publisher = {Taylor \& Francis}, address = {Abingdon}, issn = {1029-0311}, doi = {10.1080/10485252.2018.1486402}, pages = {834 -- 859}, year = {2018}, abstract = {A nonparametric goodness-of-fit test for random variables with values in a separable Hilbert space is investigated. To verify the null hypothesis that the data come from a specific distribution, an integral type test based on a Cram{\´e}r-von-Mises statistic is suggested. The convergence in distribution of the test statistic under the null hypothesis is proved and the test's consistency is concluded. Moreover, properties under local alternatives are discussed. Applications are given for data of huge but finite dimension and for functional data in infinite dimensional spaces. A general approach enables the treatment of incomplete data. In simulation studies the test competes with alternative proposals.}, language = {en} }