@inproceedings{MilkovaButenwegDumovaJovanoska2021, author = {Milkova, Kristina and Butenweg, Christoph and Dumova-Jovanoska, Elena}, title = {Region-sensitive comprehensive procedure for determination of seismic fragility curves}, series = {1st Croatian Conference on Earthquake Engineering 1CroCEE}, booktitle = {1st Croatian Conference on Earthquake Engineering 1CroCEE}, publisher = {University of Zagreb}, address = {Zagreb}, doi = {10.5592/CO/1CroCEE.2021.158}, pages = {121 -- 128}, year = {2021}, abstract = {Seismic vulnerability estimation of existing structures is unquestionably interesting topic of high priority, particularly after earthquake events. Having in mind the vast number of old masonry buildings in North Macedonia serving as public institutions, it is evident that the structural assessment of these buildings is an issue of great importance. In this paper, a comprehensive methodology for the development of seismic fragility curves of existing masonry buildings is presented. A scenario - based method that incorporates the knowledge of the tectonic style of the considered region, the active fault characterization, the earth crust model and the historical seismicity (determined via the Neo Deterministic approach) is used for calculation of the necessary response spectra. The capacity of the investigated masonry buildings has been determined by using nonlinear static analysis. MINEA software (SDA Engineering) is used for verification of the structural safety of the structures Performance point, obtained from the intersection of the capacity of the building and the spectra used, is selected as a response parameter. The thresholds of the spectral displacement are obtained by splitting the capacity curve into five parts, utilizing empirical formulas which are represented as a function of yield displacement and ultimate displacement. As a result, four levels of damage limit states are determined. A maximum likelihood estimation procedure for the process of fragility curves determination is noted as a final step in the proposed procedure. As a result, region specific series of vulnerability curves for structures are defined.}, language = {en} } @inproceedings{MilkovaRosinButenwegetal.2018, author = {Milkova, Kristina and Rosin, Julia and Butenweg, Christoph and Dumova-Jovanoska, Elena}, title = {Development of Seismic Vulnerability Curves for Region Specific Masonry Buildings}, series = {16th European Conference on Earthquake Engineering, Thessaloniki, 18-21 June, 2018}, booktitle = {16th European Conference on Earthquake Engineering, Thessaloniki, 18-21 June, 2018}, pages = {1 -- 10}, year = {2018}, language = {en} } @article{MilnickelGrap2011, author = {Milnickel, Birte and Grap, Rolf Dietmar}, title = {Chemielogistik im Kontext allgemeiner logistischer Anforderungen}, series = {Chemielogistik : Markt, Gesch{\"a}ftsmodelle, Prozesse}, journal = {Chemielogistik : Markt, Gesch{\"a}ftsmodelle, Prozesse}, editor = {Suntrop, Carsten}, publisher = {Wiley-VCH}, address = {Weinheim}, isbn = {978-3-527-32531-3}, pages = {3 -- 22}, year = {2011}, language = {de} } @masterthesis{Mingers2021, type = {Bachelor Thesis}, author = {Mingers, Laura}, title = {UN|SEEN}, publisher = {FH Aachen}, address = {Aachen}, school = {Fachhochschule Aachen}, pages = {77 Seiten}, year = {2021}, abstract = {Innerhalb der Bundeswehr erleiden einige Soldaten w{\"a}hrend ihrer Berufsaus{\"u}bung oder in Eins{\"a}tzen eine posttraumatische Belastungsst{\"o}rung (PTBS). {\"U}ber sie als Menschen und {\"u}ber ihren Alltag mit der Erkrankung wird kaum gesprochen. Es ist wichtig, diesem Tabuthema entgegenzutreten, sodass in der Gesellschaft die Betroffenen verstanden, akzeptiert und angenommen werden. Die Arbeit „UN|SEEN" setzt sich mit dieser schwierigen Thematik und den Menschen wie auch ihrer Geschichte und ihrem Leben auseinander. Im Fotobuch sind hierf{\"u}r verschiedene an PTBS erkrankte Soldaten im Alltag fotografisch begleitet und interviewt wurden. Ebenso sind Fotos aus deren Bundeswehrzeit und aus Eins{\"a}tzen im Buch eingebaut, welche als „Flashbacks" dienen. „UN|SEEN" soll den Betrachter mit diesem Thema konfrontieren, eine neue Sichtweise er{\"o}ffnen und zum Handeln anregen.}, language = {de} } @inproceedings{MirmohseniRostamizadeh2006, author = {Mirmohseni, Abdolreza and Rostamizadeh, Kobra}, title = {Quartz crystal nanobalance in conjunction with principal component analysis for identification of volatile organic compounds}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1434}, year = {2006}, abstract = {Quartz crystal nanobalance (QCN) sensors are considered as powerful masssensitive sensors to determine materials in the sub-nanogram level. In this study, a single piezoelectric quartz crystal nanobalance modified with polystyrene was employed to detect benzene, toluene, ethylbenzene and xylene (BTEX compounds). The frequency shift of the QCN sensor was found to be linear against the BTEX compound concentrations in the range about 1-45 mg l-1. The correlation coefficients for benzene, toluene, ethylbenzene, and xylene were 0.991, 0.9977, 0.9946 and 0.9971, respectively. The principal component analysis was also utilized to process the frequency response data of the single piezoelectric crystal at different times, considering to the different adsorption-desorption dynamics of BTEX compounds. Using principal component analysis, it was found that over 90\% of the data variance could still be explained by use of two principal components (PC1 and PC2). Subsequently, the successful identification of benzene and toluene was possible through the principal component analysis of the transient responses of the polystyrene modified QCN sensor. The results showed that the polystyrene-modified QCN had favorable identification and quantification performances for the BTEX compounds.}, subject = {Biosensor}, language = {en} } @article{Mischke2009, author = {Mischke, Winfried}, title = {Kurzkommentierung der \S\S 433, 436, 446 - 453, 474 - 479 BGB}, series = {LexisNexis : Elektronische Ressource / Recht (2009)}, journal = {LexisNexis : Elektronische Ressource / Recht (2009)}, year = {2009}, language = {en} } @phdthesis{Mischke1963, author = {Mischke, Winfried}, title = {Die Rechtsnatur des Nachlieferungsanspruchs beim Gattungskauf}, publisher = {Universit{\"a}t zu K{\"o}ln}, address = {K{\"o}ln}, pages = {V, 46 Seiten}, year = {1963}, language = {de} } @book{Mischke1998, author = {Mischke, Winfried}, title = {Die Fachhochschule in Deutschland : eine Darstellung am Beispiel der Fachhochschule Aachen, Fachbereich Wirtschaft / Mischke. - 1. Aufl.}, publisher = {Siebengebirgsverl. Wienands}, address = {Bad Honnef}, isbn = {3-932885-01-5}, pages = {74 S.}, year = {1998}, language = {de} } @article{Mischke1993, author = {Mischke, Winfried}, title = {Zum Anwendungsbereich der Verpackungsverordnung}, series = {Betriebs-Berater. 48 (1993), H. 10}, journal = {Betriebs-Berater. 48 (1993), H. 10}, isbn = {0340-7918}, pages = {672 -- 674}, year = {1993}, language = {de} } @article{Mischke1995, author = {Mischke, Winfried}, title = {Die Garantie im Kaufrecht}, series = {Betriebs-Berater. 50 (1995), H. 22}, journal = {Betriebs-Berater. 50 (1995), H. 22}, isbn = {0340-7918}, pages = {1093 -- 1096}, year = {1995}, language = {en} } @article{Mischke1997, author = {Mischke, Winfried}, title = {Zur Haftung des Verk{\"a}ufers f{\"u}r Sachm{\"a}ngel und Produktfehler der verkauften Waren nach deutschem, europ{\"a}ischem und internationalem Recht}, series = {Betriebs-Berater. 52 (1997), H. 30}, journal = {Betriebs-Berater. 52 (1997), H. 30}, isbn = {0340-7918}, pages = {1494 -- 1497}, year = {1997}, language = {de} } @article{Mischke1994, author = {Mischke, Winfried}, title = {Befristung einer H{\"a}ndlergarantie : Anmerkung zu dem Urteil des OLG K{\"o}ln vom 20. 8. 1993, BB 1993, 2335 , und des BGH vom 20. 12. 1978, BB 1979, 185 = NJW 1979 S. 645}, series = {Betriebs-Berater. 49 (1994), H. 31}, journal = {Betriebs-Berater. 49 (1994), H. 31}, isbn = {0340-7918}, pages = {2156 -- 2157}, year = {1994}, language = {de} } @article{Mischke1998, author = {Mischke, Winfried}, title = {Kreditsicherungsrecht: Beschr{\"a}nkung der Herstellergarantie}, series = {Betriebs-Berater. 53 (1998), H. 9}, journal = {Betriebs-Berater. 53 (1998), H. 9}, isbn = {0340-7918}, pages = {447}, year = {1998}, language = {de} } @article{Mischke1981, author = {Mischke, Winfried}, title = {Zur{\"u}ckweisung versp{\"a}teten Vorbringens {\"u}ber die in \S 296 ZPO aufgez{\"a}hlten F{\"a}lle hinaus?}, series = {Neue juristische Wochenschrift. 34 (1981), H. 11}, journal = {Neue juristische Wochenschrift. 34 (1981), H. 11}, isbn = {0341-1915}, pages = {564 -- 565}, year = {1981}, language = {de} } @article{Mischke1986, author = {Mischke, Winfried}, title = {Herausgabe von R{\"o}ntgenaufnahmen}, series = {Neue juristische Wochenschrift. 39 (1986), H. 24}, journal = {Neue juristische Wochenschrift. 39 (1986), H. 24}, isbn = {0341-1915}, pages = {1551 -- 1552}, year = {1986}, language = {de} } @article{Mischke1990, author = {Mischke, Winfried}, title = {Unzust{\"a}ndigkeit der Berufungskammer bei Klageerweiterung}, series = {Neue juristische Wochenschrift / NJW-Rechtsprechungs-Report Zivilrecht. 5 (1990), H. 11}, journal = {Neue juristische Wochenschrift / NJW-Rechtsprechungs-Report Zivilrecht. 5 (1990), H. 11}, isbn = {0179-4043}, pages = {704}, year = {1990}, language = {de} } @article{Mischke1973, author = {Mischke, Winfried}, title = {Kostenentscheidung bei einverst{\"a}ndlicher Ehescheidung}, series = {Neue juristische Wochenschrift}, volume = {26}, journal = {Neue juristische Wochenschrift}, publisher = {Beck}, address = {M{\"u}nchen}, isbn = {0341-1915}, pages = {2025 -- 45}, year = {1973}, language = {de} } @article{Mischke1971, author = {Mischke, Winfried}, title = {Schuldigerkl{\"a}rung auf eigenen Antrag}, series = {Neue juristische Wochenschrift}, volume = {24}, journal = {Neue juristische Wochenschrift}, publisher = {Beck}, address = {M{\"u}nchen}, isbn = {0341-1915}, pages = {1927 -- 43}, year = {1971}, language = {de} } @article{Mischke1978, author = {Mischke, Winfried}, title = {Zur{\"u}ckweisung versp{\"a}teten Vorbringens im fr{\"u}hen ersten Termin}, series = {Monatsschrift f{\"u}r deutsches Recht}, volume = {32}, journal = {Monatsschrift f{\"u}r deutsches Recht}, publisher = {Verlag Dr. Otto Schmidt}, address = {K{\"o}ln}, isbn = {0340-1812}, pages = {850 -- 851}, year = {1978}, language = {de} } @article{MischkeEsserHoernchen1981, author = {Mischke, Winfried and Eßer, K.-J. and H{\"o}rnchen, H.}, title = {Zur Problematik der Intensivbehandlung von Fr{\"u}h- und Neugeborenen - {\"a}rztliche, rechtliche und ethische {\"U}berlegungen / K.-J. Eßer; H. H{\"o}rnchen; W. Mischke}, series = {Klinische P{\"a}diatrie. 193 (1981), H. 1}, journal = {Klinische P{\"a}diatrie. 193 (1981), H. 1}, isbn = {0300-8630}, pages = {7 -- 9}, year = {1981}, language = {de} } @article{MischkeGirkens2011, author = {Mischke, Winfried and Girkens, Hans-Peter}, title = {Kostenvorschuss beim selbst{\"a}ndigen Beweisverfahren : zur Kostentragung, wenn der Antragsteller den f{\"u}r die Durchf{\"u}hrung erforderlichen Vorschuss f{\"u}r den Sachverst{\"a}ndigen nicht zahlt}, series = {Zeitschrift f{\"u}r die Anwaltspraxis : ZAP}, journal = {Zeitschrift f{\"u}r die Anwaltspraxis : ZAP}, number = {Fach 13}, publisher = {Westlaw Datenbank GmbH}, address = {Frankfurt a. M.}, issn = {0936-7292}, pages = {1739 -- 1740}, year = {2011}, language = {de} } @article{MischkeGirkensBaluch2007, author = {Mischke, Winfried and Girkens, Hans-Peter and Baluch, Christina}, title = {Umgehung der Sachm{\"a}ngelhaftung des Autoh{\"a}ndlers bei Verkauf eines Gebrauchtwagens? / Hans-Peter Girkens, Dr. Christina Baluch und Prof. Dr. Winfried Mischke, Aachen}, series = {Zeitschrift f{\"u}r das gesamte Schuldrecht. 6 (2007), H. 4}, journal = {Zeitschrift f{\"u}r das gesamte Schuldrecht. 6 (2007), H. 4}, isbn = {1619-7011}, pages = {130 -- 133}, year = {2007}, language = {de} } @article{MischkeNeuss2009, author = {Mischke, Winfried and Neuß, Frank}, title = {F{\"u}hrt die {\"U}bernahme der Domain eines anderen Unternehmers zur Haftung f{\"u}r dessen Schulden nach \S 25 HGB?}, series = {Zeitschrift f{\"u}r Vertragsgestaltung, Schuld- und Haftungsrecht : ZGS}, volume = {8}, journal = {Zeitschrift f{\"u}r Vertragsgestaltung, Schuld- und Haftungsrecht : ZGS}, publisher = {ZAP, Verl. f. die Rechts- und Anwaltspraxis}, address = {Recklinghausen}, issn = {1619-7011}, pages = {407 -- 409}, year = {2009}, language = {de} } @article{MischkeNeussVollmert2008, author = {Mischke, Winfried and Neuß, Frank and Vollmert, Daniel}, title = {Beweislast f{\"u}r die Voraussetzungen der Ger{\"a}te- und der Betreiberverg{\"u}tung nach \S 54a UrhG / Rechtsanw{\"a}lte Prof. Dr. Winfried Mischke, Dr. Frank Neuß und Dr. Daniel Vollmert, Aachen}, series = {Zeitschrift f{\"u}r die Anwaltspraxis (2008)}, journal = {Zeitschrift f{\"u}r die Anwaltspraxis (2008)}, isbn = {0936-7292}, pages = {587 -- 590}, year = {2008}, language = {de} } @article{MischkeNeussVollmert2007, author = {Mischke, Winfried and Neuß, Frank and Vollmert, Daniel}, title = {Ausgleich der vom Verbraucher gezogenen Nutzungen bei R{\"u}cktritt vom Kaufvertrag in der Lieferkette/ Prof. Dr. Winfried Mischke, Dr. Frank Neuß und Dr. Daniel Vollmert, alle Aachen}, series = {Zeitschrift f{\"u}r das gesamte Schuldrecht. 6 (2007), H. 6}, journal = {Zeitschrift f{\"u}r das gesamte Schuldrecht. 6 (2007), H. 6}, isbn = {1619-7011}, pages = {217 -- 218}, year = {2007}, language = {de} } @article{MischkeNouvertne2005, author = {Mischke, Winfried and Nouvertn{\´e}, Richard}, title = {Muss der Erbe dem Kreditinstitut, bei dem der Erblasser seine Anlagen unterh{\"a}lt, einen Erbschein vorlegen? Wer tr{\"a}gt das Risiko, wenn das Kreditinstitut an einen Scheinerben zahlt?}, series = {Zeitschrift f{\"u}r die Steuer- und Erbrechtspraxis. 7 (2005)}, journal = {Zeitschrift f{\"u}r die Steuer- und Erbrechtspraxis. 7 (2005)}, isbn = {1439-3182}, pages = {234 -- 239}, year = {2005}, language = {de} } @article{Mistler1998, author = {Mistler, Hans-Ludwig}, title = {Ein einfacher Weg zu wirtschaftlichen Holztr{\"a}gern. Die Querzugbemessung von Brettschichtholz-Tr{\"a}gern. Die Bemessungsgrenze kann von der Tr{\"a}gerhoehe abh{\"a}ngig gemacht werden}, series = {Deutsches Ingenieur-Blatt. 5 (1998), H. 1-2}, journal = {Deutsches Ingenieur-Blatt. 5 (1998), H. 1-2}, isbn = {0946-2422}, pages = {24 -- 29}, year = {1998}, language = {de} } @article{Mistler1982, author = {Mistler, Hans-Ludwig}, title = {{\"U}ber die Querzugfestigkeit von Fichten-Brettschichtholz in Abh{\"a}ngigkeit von der Bauteilgr{\"o}sse und der Verteilung der Beabspruchung}, series = {Ingenieurholzbau in Forschung und Praxis / Ehlbeck, J{\"u}rgen [Hrsg.]}, journal = {Ingenieurholzbau in Forschung und Praxis / Ehlbeck, J{\"u}rgen [Hrsg.]}, publisher = {Bruderverl.}, address = {Karlsruhe}, isbn = {3-87104-049-5}, pages = {33 -- 40}, year = {1982}, language = {de} } @article{Mistler1980, author = {Mistler, Hans-Ludwig}, title = {Das Spaltzugproblem bei Druckst{\"a}ben aus Nadelholz}, series = {Bauen mit Holz. 82 (1980), H. 8}, journal = {Bauen mit Holz. 82 (1980), H. 8}, isbn = {0005-6545}, pages = {462 -- 463}, year = {1980}, language = {de} } @book{Mistler1979, author = {Mistler, Hans-Ludwig}, title = {Die Tragf{\"a}higkeit des am Endauflager unter rechtwinklig ausgeklingten Brettschichttr{\"a}gern}, pages = {II, 112 S. : graph. Darst.}, year = {1979}, language = {de} } @book{MistlerMoehler1978, author = {Mistler, Hans-Ludwig and M{\"o}hler, Karl}, title = {Untersuchungen {\"u}ber den Einfluß von Ausklinkungen im Auflagerbereich von Holzbiegetr{\"a}gern auf die Tragfestigkeit : Versuche durchgef{\"u}hrt im Auftrage der Entwicklungsgemeinschaft Holzbau in der Deutschen Gesellschaft f{\"u}r Holzforschung e. V. / von Karl M{\"o}hl}, publisher = {Informationsverbundzentrum Raum und Bau}, address = {Stuttgart}, pages = {17, [26] S. : Ill., graph. Darst.}, year = {1978}, language = {de} } @inproceedings{MistlerButenwegAnthoine2004, author = {Mistler, M. and Butenweg, Christoph and Anthoine, A.}, title = {Evaluation of the failure criterion for masonry by homogenisation}, series = {Proceedings of the Seventh International Conference on Computational Structures Technology : [Lisbon, Portugal, 7 - 9 September 2004] / ed. by B. H. V. Topping and C.A. Mota Soares}, booktitle = {Proceedings of the Seventh International Conference on Computational Structures Technology : [Lisbon, Portugal, 7 - 9 September 2004] / ed. by B. H. V. Topping and C.A. Mota Soares}, publisher = {Civil-Comp Press}, address = {Stirling}, organization = {International Conference on Computational Structures Technology <7, 2004, Lissabon>}, isbn = {0-948749-95-4}, doi = {10.4203/ccp.79.201}, pages = {16 Seiten}, year = {2004}, language = {en} } @article{MistlerAnthoineButenweg2007, author = {Mistler, Michael and Anthoine, A. and Butenweg, Christoph}, title = {In-plane and out-of-plane homogenisation of masonry}, series = {Computers \& structures}, volume = {Volume 85}, journal = {Computers \& structures}, number = {Issues 17-18}, issn = {1879-2243 (E-Journal); 0045-7949 (Print)}, doi = {10.1016/j.compstruc.2006.08.087}, pages = {1321 -- 1330}, year = {2007}, language = {en} } @inproceedings{MistlerButenweg2005, author = {Mistler, Michael and Butenweg, Christoph}, title = {A seismic design procedure for masonry buildings}, series = {Proceedings of the Tenth International Conference on Civil, Structural and Environmental Engineering Computing : [Rome, Italy, 30. August - 2. September 2005] / ed. by B. H. V. Topping}, booktitle = {Proceedings of the Tenth International Conference on Civil, Structural and Environmental Engineering Computing : [Rome, Italy, 30. August - 2. September 2005] / ed. by B. H. V. Topping}, publisher = {Civil-Comp Press}, address = {Stirling}, organization = {International Conference on Civil, Structural and Environmental Engineering Computing <10, 2005, Rome>}, isbn = {1-905088-00-0}, doi = {10.4203/ccp.81.193}, pages = {465 -- 467}, year = {2005}, language = {en} } @article{MistlerButenweg2005, author = {Mistler, Michael and Butenweg, Christoph}, title = {Verformungsbasierter seismischer Nachweis von Mauerwerksbauten mit der Kapazit{\"a}tsspektrum-Methode}, series = {Mauerwerk : European journal of masonry}, volume = {Volume 9}, journal = {Mauerwerk : European journal of masonry}, number = {Issue 6}, issn = {1437-1022 (E-Journal); 1432-3427 (Print)}, doi = {10.1002/dama.200590098}, pages = {255 -- 261}, year = {2005}, language = {de} } @article{MistlerButenwegFehlingetal.2007, author = {Mistler, Michael and Butenweg, Christoph and Fehling, Ekkehard and St{\"u}rz, Jochen}, title = {Verformungsbasierte seismische Bemessung von Mauerwerksbauten auf Grundlage zyklischer Schubwandversuche}, series = {Bauingenieur : die richtungsweisende Zeitschrift im Bauingenieurswesen ; offizielle Zeitschrift der VDI-Gesellschaft Bautechnik. Beilage: D-A-CH-Mitteilungsblatt}, volume = {Band 82}, journal = {Bauingenieur : die richtungsweisende Zeitschrift im Bauingenieurswesen ; offizielle Zeitschrift der VDI-Gesellschaft Bautechnik. Beilage: D-A-CH-Mitteilungsblatt}, issn = {1434-6591}, pages = {S3 -- S11}, year = {2007}, language = {de} } @article{MistlerButenwegMeskouris2006, author = {Mistler, Michael and Butenweg, Christoph and Meskouris, Konstantin}, title = {Modelling methods of historic masonry buildings under seismic excitation}, series = {Journal of seismology}, volume = {Volume 10}, journal = {Journal of seismology}, number = {No. 4}, issn = {1383-4649 (Print) ; 1573-157X (E-Journal)}, doi = {10.1007/s10950-006-9033-z}, pages = {497 -- 510}, year = {2006}, language = {en} } @article{MiyamatoSakakitaWagneretal.2015, author = {Miyamato, Ko-ichiro and Sakakita, Sakura and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Application of chemical imaging sensor to in-situ pH imaging in the vicinity of a corroding metal surface}, series = {Electrochimica Acta}, volume = {183}, journal = {Electrochimica Acta}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0013-4686}, doi = {10.1016/j.electacta.2015.07.184}, pages = {137 -- 142}, year = {2015}, abstract = {The chemical imaging sensor was applied to in-situ pH imaging of the solution in the vicinity of a corroding surface of stainless steel under potentiostatic polarization. A test piece of polished stainless steel was placed on the sensing surface leaving a narrow gap filled with artificial seawater and the stainless steel was corroded under polarization. The pH images obtained during polarization showed correspondence between the region of lower pH and the site of corrosion. It was also found that the pH value in the gap became as low as 2 by polarization, which triggered corrosion.}, language = {en} } @article{MiyamotoIchimuraWagneretal.2012, author = {Miyamoto, K. and Ichimura, H. and Wagner, Torsten and Yoshinobu, T. and Sch{\"o}ning, Michael Josef}, title = {Chemical Imaging of ion Diffusion in a Microfluidic Channel}, series = {Procedia Engineering}, journal = {Procedia Engineering}, number = {47}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2012.09.289}, pages = {886 -- 889}, year = {2012}, abstract = {The chemical imaging sensor is a chemical sensor which is capable of visualizing the spatial distribution of chemical species in sample solution. In this study, a novel measurement system based on the chemical imaging sensor was developed to observe the inside of a Y-shaped microfluidic channel while injecting two sample solutions from two branches. From the collected chemical images, it was clearly observed that the injected solutions formed laminar flows in the microfluidic channel. In addition, ion diffusion across the laminar flows was observed. This label-free method can acquire quantitative data of ion distribution and diffusion in microfluidic devices, which can be used to determine the diffusion coefficients, and therefore, the molecular weights of chemical species in the sample solution.}, language = {en} } @article{MiyamotoKuwabaraKanohetal.2009, author = {Miyamoto, K. and Kuwabara, Yohei and Kanoh, Shin'ichiro and Yoshinobu, Tatsuo and Wagner, Torsten and Sch{\"o}ning, Michael Josef}, title = {Chemical image scanner based on FDM-LAPS}, series = {Sensors and Actuators B: Chemical. 137 (2009), H. 2}, journal = {Sensors and Actuators B: Chemical. 137 (2009), H. 2}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {0925-4005}, pages = {533 -- 538}, year = {2009}, language = {en} } @article{MiyamotoSekiWagneretal.2014, author = {Miyamoto, K. and Seki, K. and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, T.}, title = {Enhancement of the spatial resolution of the chemical imaging sensor by a hybrid fiber-optic illumination}, series = {Procedia Engineering}, volume = {87}, journal = {Procedia Engineering}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2014.11.563}, pages = {612 -- 615}, year = {2014}, abstract = {The chemical imaging sensor, which is based on the principle of the light-addressable potentiometric sensor (LAPS), is a powerful tool to visualize the spatial distribution of chemical species on the sensor surface. The spatial resolution of this sensor depends on the diffusion of photocarriers excited by a modulated light. In this study, a novel hybrid fiber-optic illumination was developed to enhance the spatial resolution. It consists of a modulated light probe to generate a photocurrent signal and a ring of constant light, which suppresses the lateral diffusion of minority carriers excited by the modulated light. It is demonstrated that the spatial resolution was improved from 92 μm to 68 μm.}, language = {en} } @article{MiyamotoWagnerSchoeningetal.2011, author = {Miyamoto, K. and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, T.}, title = {Multi-well structure for cell culture on the chemical imaging sensor}, publisher = {IEEE}, address = {New York}, pages = {2130 -- 2132}, year = {2011}, language = {en} } @article{MiyamotoBingWagneretal.2015, author = {Miyamoto, Ko-ichiro and Bing, Yu and Wagner, Torsten and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {Visualization of Defects on a Cultured Cell Layer by Utilizing Chemical Imaging Sensor}, series = {Procedia Engineering}, volume = {120}, journal = {Procedia Engineering}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2015.08.806}, pages = {936 -- 939}, year = {2015}, abstract = {The chemical imaging sensor is a field-effect sensor which is able to visualize both the distribution of ions (in LAPS mode) and the distribution of impedance (in SPIM mode) inthe sample. In this study, a novel wound-healing assay is proposed, in which the chemical imaging sensor operated in SPIM mode is applied to monitor the defect of a cell layer brought into proximity of the sensing surface.A reduced impedance inside the defect, which was artificially formed ina cell layer, was successfully visualized in a photocurrent image.}, language = {en} } @article{MiyamotoHayashiSakamotoetal.2017, author = {Miyamoto, Ko-ichiro and Hayashi, Kosuke and Sakamoto, Azuma and Werner, Frederik and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {A high-Q resonance-mode measurement of EIS capacitive sensor by elimination of series resistance}, series = {Sensor and Actuators B: Chemical}, volume = {248}, journal = {Sensor and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2017.03.002}, pages = {1006 -- 1010}, year = {2017}, abstract = {An EIS capacitive sensor is a semiconductor-based potentiometric sensor, which is sensitive to the ion concentration or pH value of the solution in contact with the sensing surface. To detect a small change in the ion concentration or pH, a small capacitance change must be detected. Recently, a resonance-mode measurement was proposed, in which an inductor was connected to the EIS capacitive sensor and the resonant frequency was correlated with the pH value. In this study, the Q factor of the resonant circuit was enhanced by canceling the internal resistance of the reference electrode and the internal resistance of the inductor coil with the help of a bypass capacitor and a negative impedance converter, respectively. 1\% variation of the signal in the developed system corresponded to a pH change of 3.93 mpH, which was about 1/12 of the conventional method, suggesting a better performance in detection of a small pH change.}, language = {en} } @article{MiyamotoHirayamaWagneretal.2013, author = {Miyamoto, Ko-ichiro and Hirayama, Yuji and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Visualization of enzymatic reaction in a microfluidic channel using chemical imaging sensor}, series = {Electrochimica acta}, journal = {Electrochimica acta}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3859 (E-Journal); 0013-4686 (Print)}, pages = {Publ. online}, year = {2013}, language = {en} } @article{MiyamotoIchimuraWagneretal.2013, author = {Miyamoto, Ko-ichiro and Ichimura, Hiroki and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Chemical imaging of the concentration profile of ion diffusion in a microfluidic channel}, series = {Sensors and actuators. B: Chemical}, volume = {189}, journal = {Sensors and actuators. B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3077 (E-Journal); 0925-4005 (Print)}, doi = {10.1016/j.snb.2013.04.057}, pages = {240 -- 245}, year = {2013}, abstract = {The chemical imaging sensor is a device to visualize the spatial distribution of chemical species based on the principle of LAPS (light-addressable potentiometric sensor), which is a field-effect chemical sensor based on semiconductor. In this study, the chemical imaging sensor has been applied to investigate the ion profile of laminar flows in a microfluidic channel. The chemical images (pH maps) were collected in a Y-shaped microfluidic channel while injecting HCl and NaCl solutions into two branches. From the chemical images, it was clearly observed that the injected solutions formed laminar flows in the channel. In addition, ion diffusion across the laminar flows was observed, and the diffusion coefficient could be derived by fitting the pH profiles to the Fick's equation.}, language = {en} } @article{MiyamotoItabashiWagneretal.2014, author = {Miyamoto, Ko-ichiro and Itabashi, Akinori and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {High-speed chemical imaging inside a microfluidic channel}, series = {Sensors and actuators. B: Chemical}, volume = {194}, journal = {Sensors and actuators. B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3077 (E-Journal); 0925-4005 (Print)}, doi = {10.1016/j.snb.2013.12.090}, pages = {521 -- 527}, year = {2014}, abstract = {In this study, a high-speed chemical imaging system was developed for visualization of the interior of a microfluidic channel. A microfluidic channel was constructed on the sensor surface of the light-addressable potentiometric sensor (LAPS), on which the ion concentrations could be measured in parallel at up to 64 points illuminated by optical fibers. The temporal change of pH distribution inside the microfluidic channel was recorded at a maximum rate of 100 frames per second (fps). The high frame rate allowed visualization of moving interfaces and plugs in the channel even at a flow velocity of 111 mm/s, which suggests the feasibility of plug-based microfluidic devices for flow-injection analysis (FIA).}, language = {en} } @article{MiyamotoKanekoMatsuoetal.2010, author = {Miyamoto, Ko-ichiro and Kaneko, Kazumi and Matsuo, Akira and Wagner, Torsten and Kanoh, Shin`ichiro and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Miniaturized chemical imaging sensor system using an OLED display panel}, series = {Procedia Engineering}, volume = {5}, journal = {Procedia Engineering}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2010.09.160}, pages = {516 -- 519}, year = {2010}, abstract = {The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the currentvoltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated.}, language = {en} } @article{MiyamotoKanekoMatsuoetal.2012, author = {Miyamoto, Ko-ichiro and Kaneko, Kazumi and Matsuo, Akira and Wagner, Torsten and Kanoh, Shin{\´i}chiro and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Miniaturized chemical imaging sensor system using an OLED display panel}, series = {Sensors and Actuators B: Chemical}, volume = {170}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2011.02.029}, pages = {82 -- 87}, year = {2012}, abstract = {The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the current-voltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated.}, language = {en} } @article{MiyamotoSatoAbeetal.2016, author = {Miyamoto, Ko-Ichiro and Sato, Takuya and Abe, Minami and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Light-addressable potentiometric sensor as a sensing element in plug-based microfluidic devices}, series = {Micromachines}, volume = {7}, journal = {Micromachines}, number = {7}, publisher = {MDPI}, address = {Basel}, issn = {2072-666X}, doi = {10.3390/mi7070111}, pages = {111}, year = {2016}, abstract = {A plug-based microfluidic system based on the principle of the light-addressable potentiometric sensor (LAPS) is proposed. The LAPS is a semiconductor-based chemical sensor, which has a free addressability of the measurement point on the sensing surface. By combining a microfluidic device and LAPS, ion sensing can be performed anywhere inside the microfluidic channel. In this study, the sample solution to be measured was introduced into the channel in a form of a plug with a volume in the range of microliters. Taking advantage of the light-addressability, the position of the plug could be monitored and pneumatically controlled. With the developed system, the pH value of a plug with a volume down to 400 nL could be measured. As an example of plug-based operation, two plugs were merged in the channel, and the pH change was detected by differential measurement.}, language = {en} } @article{MiyamotoSugawaraKanohetal.2010, author = {Miyamoto, Ko-ichiro and Sugawara, Yuri and Kanoh, Shin´ichiro and Yoshinobu, Tatsuo and Wagner, Torsten and Sch{\"o}ning, Michael Josef}, title = {Image correction method for the chemical imaging sensor}, series = {Sensors and Actuators B: Chemical}, volume = {144}, journal = {Sensors and Actuators B: Chemical}, number = {2}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2008.10.069}, pages = {344 -- 348}, year = {2010}, abstract = {The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the spatial distribution of chemical species. For the practical application of this sensor, artifacts in the chemical images due to defects of the semiconductor substrate and contamination of the sensing surface etc. have been a major problem. An image correction method was developed to eliminate the influence of nonuniformity of individual sensor plate.}, language = {en} } @inproceedings{MiyamotoSutoWerneretal.2017, author = {Miyamoto, Ko-ichiro and Suto, Takeyuki and Werner, Frederik and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Restraining the Diffusion of Photocarriers to Improve the Spatial Resolution of the Chemical Imaging Sensor}, series = {MDPI Proceedings}, volume = {1}, booktitle = {MDPI Proceedings}, number = {4}, doi = {10.3390/proceedings1040477}, pages = {4 Seiten}, year = {2017}, language = {en} } @article{MiyamotoWagnerMimuraetal.2009, author = {Miyamoto, Ko-ichiro and Wagner, Torsten and Mimura, Shuhei and Kanoh, Shin`ichiro and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {Constant-phase-mode operation of the light-addressable potentiometric sensor}, series = {Procedia Chemistry. 1 (2009), H. 1}, journal = {Procedia Chemistry. 1 (2009), H. 1}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1876-6196}, pages = {1487 -- 1490}, year = {2009}, language = {en} } @article{MiyamotoWagnerMimuraetal.2011, author = {Miyamoto, Ko-ichiro and Wagner, Torsten and Mimura, Shuhei and Kanoh, Shin{\´i}chiro and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {Constant-phase-mode operation of the light-addressable potentiometric sensor}, series = {Sensors and Actuators B: Chemical. 154 (2011), H. 2}, journal = {Sensors and Actuators B: Chemical. 154 (2011), H. 2}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1873-3077}, pages = {119 -- 123}, year = {2011}, language = {en} } @article{MiyamotoWagnerYoshinobuetal.2011, author = {Miyamoto, Ko-ichiro and Wagner, Torsten and Yoshinobu, Tatsuo and Kanoh, Shin`ichiro and Sch{\"o}ning, Michael Josef}, title = {Phase-mode LAPS and its application to chemical imaging}, series = {Sensors and Actuators B: Chemical. 154 (2011), H. 1}, journal = {Sensors and Actuators B: Chemical. 154 (2011), H. 1}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1873-3077}, pages = {28 -- 32}, year = {2011}, language = {en} } @article{MiyamotoWagnerYoshinobuetal.2011, author = {Miyamoto, Ko-ichiro and Wagner, Torsten and Yoshinobu, Tatsuo and Kanoh, Shin`ichiro and Sch{\"o}ning, Michael Josef}, title = {Phase-mode operation of FDM-LAPS}, series = {Sensor letters}, volume = {9}, journal = {Sensor letters}, number = {2}, publisher = {American Scientific Publishers}, address = {Stevenson Ranch, Calif.}, isbn = {1546-1971}, pages = {691 -- 694}, year = {2011}, language = {en} } @article{MiyamotoYoshidaSakaietal.2011, author = {Miyamoto, Ko-ichiro and Yoshida, Midori and Sakai, Taito and Matsuzaka, Atsushi and Wagner, Torsten and Kanoh, Sanoh and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {Differential setup of light-addressable potentiometric sensor with an enzyme reactor in a flow channel}, series = {Japanese Journal of Applied Physics. 50 (2011)}, journal = {Japanese Journal of Applied Physics. 50 (2011)}, publisher = {Japan Society of Applied Physics}, address = {Bristol}, isbn = {0021-4922}, pages = {04DL08-1 -- 04DL08-5}, year = {2011}, language = {en} } @article{MiyamotoYuIsodaetal.2016, author = {Miyamoto, Ko-ichiro and Yu, Bing and Isoda, Hiroko and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Visualization of the recovery process of defects in a cultured cell layer by chemical imaging sensor}, series = {Sensors and Actuators B: Chemical}, volume = {236}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2016.04.018}, pages = {965 -- 969}, year = {2016}, abstract = {The chemical imaging sensor is a field-effect sensor which is able to visualize both the distribution of ions (in LAPS mode) and the distribution of impedance (in SPIM mode) in the sample. In this study, a novel cell assay is proposed, in which the chemical imaging sensor operated in SPIM mode is applied to monitor the recovery of defects in a cell layer brought into proximity of the sensing surface. A reduced impedance at a defect formed artificially in a cell layer was successfully visualized in a photocurrent image. The cell layer was cultured over two weeks, during which the temporal change of the photocurrent distribution corresponding to the recovery of the defect was observed.}, language = {de} } @article{MiyamotoSekiSutoetal.2018, author = {Miyamoto, Koichiro and Seki, Kosuke and Suto, Takeyuki and Werner, Frederik and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Improved spatial resolution of the chemical imaging sensor with a hybrid illumination that suppresses lateral diffusion of photocarriers}, series = {Sensor and Actuators B: Chemical}, volume = {273}, journal = {Sensor and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2018.07.016}, pages = {1328 -- 1333}, year = {2018}, abstract = {The chemical imaging sensor is a semiconductor-based chemical sensor capable of visualizing pH and ion distributions. The spatial resolution depends on the lateral diffusion of photocarriers generated by illumination of the semiconductor substrate. In this study, two types of optical setups, one based on a bundle of optical fibers and the other based on a binocular tube head, were developed to project a hybrid illumination of a modulated light beam and a ring-shaped constant illumination onto the sensor plate. An improved spatial resolution was realized by the ring-shaped constant illumination, which suppressed lateral diffusion of photocarriers by enhanced recombination due to the increased carrier concentration.}, language = {en} } @inproceedings{MohanGrossMenzeletal.2021, author = {Mohan, Nijanthan and Groß, Rolf Fritz and Menzel, Karsten and Theis, Fabian}, title = {Opportunities and Challenges in the Implementation of Building Information Modeling for Prefabrication of Heating, Ventilation and Air Conditioning Systems in Small and Medium-Sized Contracting Companies in Germany - A Case Study}, series = {WIT Transactions on The Built Environment, Vol. 205}, booktitle = {WIT Transactions on The Built Environment, Vol. 205}, publisher = {WIT Press}, address = {Southampton}, issn = {1743-3509}, doi = {10.2495/BIM210101}, pages = {117 -- 126}, year = {2021}, abstract = {Even though BIM (Building Information Modelling) is successfully implemented in most of the world, it is still in the early stages in Germany, since the stakeholders are sceptical of its reliability and efficiency. The purpose of this paper is to analyse the opportunities and obstacles to implementing BIM for prefabrication. Among all other advantages of BIM, prefabrication is chosen for this paper because it plays a vital role in creating an impact on the time and cost factors of a construction project. The project stakeholders and participants can explicitly observe the positive impact of prefabrication, which enables the breakthrough of the scepticism factor among the small-scale construction companies. The analysis consists of the development of a process workflow for implementing prefabrication in building construction followed by a practical approach, which was executed with two case studies. It was planned in such a way that, the first case study gives a first-hand experience for the workers at the site on the BIM model so that they can make much use of the created BIM model, which is a better representation compared to the traditional 2D plan. The main aim of the first case study is to create a belief in the implementation of BIM Models, which was succeeded by the execution of offshore prefabrication in the second case study. Based on the case studies, the time analysis was made and it is inferred that the implementation of BIM for prefabrication can reduce construction time, ensures minimal wastes, better accuracy, less problem-solving at the construction site. It was observed that this process requires more planning time, better communication between different disciplines, which was the major obstacle for successful implementation. This paper was carried out from the perspective of small and medium-sized mechanical contracting companies for the private building sector in Germany.}, language = {en} } @book{Mohnke2005, author = {Mohnke, Andreas}, title = {Lehr- und {\"U}bungsbuch Mikrosystemtechnik : Grundlagen ; mit 24 Tabellen}, publisher = {Fachbuchverl. Leipzig im Carl-Hanser-Verl.}, address = {M{\"u}nchen}, isbn = {3-446-40007-9}, pages = {173 S. : graph. Darst. + 1 CD-ROM}, year = {2005}, language = {de} } @article{Mohnke1987, author = {Mohnke, Andreas}, title = {High-rate sputtering of zinc oxide with a funnel-shaped magnetic field: Effect of the target thickness on the layer properties}, series = {Vakuum-Technik. 36 (1987), H. 5}, journal = {Vakuum-Technik. 36 (1987), H. 5}, isbn = {0042-2266}, pages = {148 -- 151}, year = {1987}, language = {en} } @article{Mohnke1985, author = {Mohnke, Andreas}, title = {Kathodenzerst{\"a}ubung von Zinkoxid f{\"u}r die Akustoelektronik}, series = {Universit{\"a}t : Wissenschaftliche Beitr{\"a}ge : WB (1985)}, journal = {Universit{\"a}t : Wissenschaftliche Beitr{\"a}ge : WB (1985)}, isbn = {0440-1298}, pages = {94 -- 95}, year = {1985}, language = {de} } @article{MohnkeSchuckel1986, author = {Mohnke, Andreas and Schuckel, G.}, title = {Tempern von Oberfl{\"a}chenwellenwandlern in Schichtstruktur}, series = {Technische Hochschule Ilmenau / Bibliothek: Wissenschaftliche Zeitschrift. 32 (1986), H. 3}, journal = {Technische Hochschule Ilmenau / Bibliothek: Wissenschaftliche Zeitschrift. 32 (1986), H. 3}, isbn = {0043-6917}, pages = {151 -- 160}, year = {1986}, language = {de} } @article{MohnkeSchuckel1985, author = {Mohnke, Andreas and Schuckel, G.}, title = {Eigenschaften des Schichtsystems ZnO/Glas f{\"u}r die Mikroakustik. Schuckel, G.; Mohnke, A.}, series = {Technische Hochschule Ilmenau / Bibliothek: Wissenschaftliche Zeitschrift. 31 (1985), H. 4}, journal = {Technische Hochschule Ilmenau / Bibliothek: Wissenschaftliche Zeitschrift. 31 (1985), H. 4}, isbn = {0043-6917}, pages = {157 -- 164}, year = {1985}, language = {de} } @article{Mohr2005, author = {Mohr, Klaus}, title = {Das Bild im Kopf}, series = {Boxhorn. 12 (2005), H. Sehsturz}, journal = {Boxhorn. 12 (2005), H. Sehsturz}, pages = {8 -- 9}, year = {2005}, language = {de} } @article{Mohr2004, author = {Mohr, Klaus}, title = {Mein Gott bist du gut}, series = {Boxhorn. 11 (2004), H. Inflation}, journal = {Boxhorn. 11 (2004), H. Inflation}, pages = {24 -- 25}, year = {2004}, language = {de} } @article{Mohr2004, author = {Mohr, Klaus}, title = {-----}, series = {Boxhorn. 11 (2004), H. Inflation}, journal = {Boxhorn. 11 (2004), H. Inflation}, pages = {44}, year = {2004}, language = {de} } @article{Mohr2000, author = {Mohr, Klaus}, title = {Wo kommen wir her, wo gehen wir hin und was machen wir in der Zwischenzeit?}, series = {Boxhorn. 4 (2000), H. Boxenstop}, journal = {Boxhorn. 4 (2000), H. Boxenstop}, pages = {38 -- 39}, year = {2000}, language = {de} } @article{Mohr2013, author = {Mohr, Klaus}, title = {DEBEDE DE HAKAPE}, series = {Idiopendent Lyfestile (Boxhorn ; 27)}, journal = {Idiopendent Lyfestile (Boxhorn ; 27)}, publisher = {Fachhochschule Aachen}, address = {Aachen}, issn = {1864-2535}, pages = {40 -- 45}, year = {2013}, language = {de} } @masterthesis{Mok2023, type = {Bachelor Thesis}, author = {Mok, Pia Peixia}, title = {Flowcean Qi : a gentle Reminder to take a deep breath.}, publisher = {FH Aachen}, address = {Aachen}, pages = {84 Seiten}, year = {2023}, abstract = {Atmen tut jeder, automatisch. Es wird nicht auf die Ausf{\"u}hrung geachtet. Doch was, wenn nur ein wenig Feinschliff an unserer Atmung bereits Großes f{\"u}r unsere Gesundheit bewirkt? Von etlichen unterschiedlichen Studien wurde bezeugt, dass Atmung und Empfinden eins sind. Das pers{\"o}nliche Empfinden ist unser Portal zur Außenwelt. Die Art wie wir auf {\"a}ußerliche Reize reagieren, wie achtsam wir im Tun und Denken sind, spiegelt unsere Innenwelt und k{\"o}rperliches Wohlbefinden wieder. FLOWCEAN QI dient dazu, Stress- und Angstst{\"o}rungen im Alltagsleben f{\"u}r Berufst{\"a}tige mit hohem Stressfaktor zu reduzieren. Vor allem, um das Gesundheitssystem zu entlasten und die Psyche der Menschen gesund wieder aufzubauen. Sind Berufst{\"a}tige viel gelassener, steigen auch Leistung und Produktivit{\"a}t. Es ist immer wichtig, die Kernursache von Problemen zu finden und zu l{\"o}sen. So k{\"o}nnen auch vielerlei andere auf die Psyche zur{\"u}ckzuf{\"u}hrende Probleme der Gesellschaft gel{\"o}st werden. FLOWCEAN QI agiert durch modernste Technologie aktiv mit dem Nutzer. Die KI-Assistenz gestaltet das Lernen der Atemtechniken spaßiger, was wiederum den Lerneffekt verbessert. Der Beamer wird im Innenbereich platziert und der Tracker begleitet einen unterwegs und zeichnet die Datenanalyse auf. F{\"u}r mehr Datenschutz ist das Armband ein reines offline Produkt. F{\"o}rmlich sollte es dem Nutzer nah sein, naturverbunden, vertrauensw{\"u}rdig und beruhigend wirken. FLOWCEAN QI basiert gestalterisch auf eine antike japanische Philosophie namens „Kintsugi". Nach der japanischen Philosophie Kintsugi werden zerbrochene Teegl{\"a}ser wiederzusammengeklebt statt weggeworfen. Die in Teile getrennten Elemente werden glatt und geschmeidig wieder zusammengef{\"u}gt. Sie formen ein neues Ganzes, dass die Sch{\"o}nheit des Originals meist {\"u}bertrifft. Die {\"A}sthetik hinter „Kintsugi" nennt man „Wabi-Sabi". Es bedeutet, die Sch{\"o}nheit im Verg{\"a}nglichen, Alten oder Fehlerhaften zu verstehen. Die Philosophie dahinter wird metaphorisch auf das Design abgebildet und auf unsere Gesundheit {\"u}bertragen. Statt letztere zu ignorieren, schenken wir ihr unsere volle Aufmerksamkeit. Ziel der Produkte ist, uns stets an sie zu erinnern, sodass wir t{\"a}glich an unserem Wohlbefinden arbeiten k{\"o}nnen.}, language = {de} } @book{Molinnus2018, author = {Molinnus, Denise}, title = {Integration of biomolecular logic principles with electronic transducers on a chip}, publisher = {Philipps-Universit{\"a}t / Fachbereich Pharmazie}, address = {Marburg/Lahn}, year = {2018}, language = {de} } @article{MolinnusBegingLowisetal.2020, author = {Molinnus, Denise and Beging, Stefan and Lowis, Carsten and Sch{\"o}ning, Michael Josef}, title = {Towards a multi-enzyme capacitive field-effect biosensor by comparative study of drop-coating and nano-spotting technique}, series = {Sensors}, volume = {20}, journal = {Sensors}, number = {17}, publisher = {MDPI}, address = {Basel}, isbn = {1424-8220}, doi = {10.3390/s20174924}, pages = {Artikel 4942}, year = {2020}, abstract = {Multi-enzyme immobilization onto a capacitive field-effect biosensor by nano-spotting technique is presented. The nano-spotting technique allows to immobilize different enzymes simultaneously on the sensor surface with high spatial resolution without additional photolithographical patterning. The amount of applied enzymatic cocktail on the sensor surface can be tailored. Capacitive electrolyte-insulator-semiconductor (EIS) field-effect sensors with Ta2O5 as pH-sensitive transducer layer have been chosen to immobilize the three different (pL droplets) enzymes penicillinase, urease, and glucose oxidase. Nano-spotting immobilization is compared to conventional drop-coating method by defining different geometrical layouts on the sensor surface (fully, half-, and quarter-spotted). The drop diameter is varying between 84 µm and 102 µm, depending on the number of applied drops (1 to 4) per spot. For multi-analyte detection, penicillinase and urease are simultaneously nano-spotted on the EIS sensor. Sensor characterization was performed by C/V (capacitance/voltage) and ConCap (constant capacitance) measurements. Average penicillin, glucose, and urea sensitivities for the spotted enzymes were 81.7 mV/dec, 40.5 mV/dec, and 68.9 mV/dec, respectively.}, language = {en} } @article{MolinnusBaeckerIkenetal.2015, author = {Molinnus, Denise and B{\"a}cker, Matthias and Iken, Heiko and Poghossian, Arshak and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Concept for a biomolecular logic chip with an integrated sensor and actuator function}, series = {Physica status solidi (a)}, volume = {212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431913}, pages = {1382 -- 1388}, year = {2015}, abstract = {A concept for a new generation of an integrated multi-functional biosensor/actuator system is developed, which is based on biomolecular logic principles. Such a system is expected to be able to detect multiple biochemical input signals simultaneously and in real-time and convert them into electrical output signals with logical operations such as OR, AND, etc. The system can be designed as a closed-loop drug release device triggered by an enzyme logic gate, while the release of the drug induced by the actuator at the required dosage and timing will be controlled by an additional drug sensor. Thus, the system could help to make an accurate and specific diagnosis. The presented concept is exemplarily demonstrated by using an enzyme logic gate based on a glucose/glucose oxidase system, a temperature-responsive hydrogel mimicking the actuator function and an insulin (drug) sensor. In this work, the results of functional testing of individual amperometric glucose and insulin sensors as well as an impedimetric sensor for the detection of the hydrogel swelling/shrinking are presented.}, language = {en} } @article{MolinnusBaeckerSiegertetal.2015, author = {Molinnus, Denise and B{\"a}cker, Matthias and Siegert, Petra and Willenberg, H. and Poghossian, Arshak and Keusgen, M. and Sch{\"o}ning, Michael Josef}, title = {Detection of Adrenaline Based on Substrate Recycling Amplification}, series = {Procedia Engineering}, volume = {120}, journal = {Procedia Engineering}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2015.08.708}, pages = {540 -- 543}, year = {2015}, abstract = {An amperometric enzyme biosensor has been applied for the detection of adrenaline. The adrenaline biosensor has been prepared by modification of an oxygen electrode with the enzyme laccase that operates at a broad pH range between pH 3.5 to pH 8. The enzyme molecules were immobilized via cross-linking with glutaraldehyde. The sensitivity of the developed adrenaline biosensor in different pH buffer solutions has been studied.}, language = {en} } @article{MolinnusDrinicIkenetal.2021, author = {Molinnus, Denise and Drinic, Aleksander and Iken, Heiko and Kr{\"o}ger, Nadja and Zinser, Max and Smeets, Ralf and K{\"o}pf, Marius and Kopp, Alexander and Sch{\"o}ning, Michael Josef}, title = {Towards a flexible electrochemical biosensor fabricated from biocompatible Bombyx mori silk}, series = {Biosensors and Bioelectronics}, volume = {183}, journal = {Biosensors and Bioelectronics}, number = {Art. 113204}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0956-5663}, doi = {10.1016/j.bios.2021.113204}, year = {2021}, language = {en} } @article{MolinnusHardtKaeveretal.2018, author = {Molinnus, Denise and Hardt, G. and K{\"a}ver, L. and Willenberg, H.S. and Kr{\"o}ger, J.-C. and Poghossian, Arshak and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Chip-based biosensor for the detection of low adrenaline concentrations to support adrenal venous sampling}, series = {Sensor and Actuators B: Chemical}, volume = {272}, journal = {Sensor and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2018.05.136}, pages = {21 -- 27}, year = {2018}, abstract = {A chip-based amperometric biosensor referring on using the bioelectrocatalytical amplification principle for the detection of low adrenaline concentrations is presented. The adrenaline biosensor has been prepared by modification of a platinum thin-film electrode with an enzyme membrane containing the pyrroloquinoline quinone-dependent glucose dehydrogenase and glutaraldehyde. Measuring conditions such as temperature, pH value, and glucose concentration have been optimized to achieve a high sensitivity and a low detection limit of about 1 nM adrenaline measured in phosphate buffer at neutral pH value. The response of the biosensor to different catecholamines has also been proven. Long-term stability of the adrenaline biosensor has been studied over 10 days. In addition, the biosensor has been successfully applied for adrenaline detection in human blood plasma for future biomedical applications. Furthermore, preliminary experiments have been carried to detect the adrenaline-concentration difference measured in peripheral blood and adrenal venous blood, representing the adrenal vein sampling procedure of a physician.}, language = {en} } @inproceedings{MolinnusHardtKaeveretal.2017, author = {Molinnus, Denise and Hardt, Gabriel and K{\"a}ver, Larissa and Willenberg, Holger S. and Poghossian, Arshak and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Detection of Adrenaline Based on Bioelectrocatalytical System to Support Tumor Diagnostic Technology}, series = {MDPI Proceedings}, booktitle = {MDPI Proceedings}, doi = {10.3390/proceedings1040506}, pages = {4 Seiten}, year = {2017}, language = {en} } @article{MolinnusHardtSiegertetal.2018, author = {Molinnus, Denise and Hardt, Gabriel and Siegert, Petra and Willenberg, Holger S. and Poghossian, Arshak and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Detection of Adrenaline in Blood Plasma as Biomarker for Adrenal Venous Sampling}, series = {Electroanalysis}, volume = {30}, journal = {Electroanalysis}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1521-4109}, doi = {10.1002/elan.201800026}, pages = {937 -- 942}, year = {2018}, abstract = {An amperometric bi-enzyme biosensor based on substrate recycling principle for the amplification of the sensor signal has been developed for the detection of adrenaline in blood. Adrenaline can be used as biomarker verifying successful adrenal venous sampling procedure. The adrenaline biosensor has been realized via modification of a galvanic oxygen sensor with a bi-enzyme membrane combining a genetically modified laccase and a pyrroloquinoline quinone-dependent glucose dehydrogenase. The measurement conditions such as pH value and temperature were optimized to enhance the sensor performance. A high sensitivity and a low detection limit of about 0.5-1 nM adrenaline have been achieved in phosphate buffer at pH 7.4, relevant for measurements in blood samples. The sensitivity of the biosensor to other catecholamines such as noradrenaline, dopamine and dobutamine has been studied. Finally, the sensor has been successfully applied for the detection of adrenaline in human blood plasma.}, language = {en} } @article{MolinnusIkenJohnenetal.2022, author = {Molinnus, Denise and Iken, Heiko and Johnen, Anna Lynn and Richstein, Benjamin and Hellmich, Lena and Poghossian, Arshak and Knoch, Joachim and Sch{\"o}ning, Michael Josef}, title = {Miniaturized pH-Sensitive Field-Effect Capacitors with Ultrathin Ta₂O₅ Films Prepared by Atomic Layer Deposition}, series = {physica status solidi (a) applications and materials science}, volume = {219}, journal = {physica status solidi (a) applications and materials science}, number = {8}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.202100660}, pages = {7 Seiten}, year = {2022}, abstract = {Miniaturized electrolyte-insulator-semiconductor capacitors (EISCAPs) with ultrathin gate insulators have been studied in terms of their pH-sensitive sensor characteristics: three different EISCAP systems consisting of Al-p-Si-Ta2O5(5 nm), Al-p-Si-Si3N4(1 or 2 nm)-Ta2O5 (5 nm), and Al-p-Si-SiO2(3.6 nm)-Ta2O5(5 nm) layer structures are characterized in buffer solution with different pH values by means of capacitance-voltage and constant capacitance method. The SiO2 and Si3N4 gate insulators are deposited by rapid thermal oxidation and rapid thermal nitridation, respectively, whereas the Ta2O5 film is prepared by atomic layer deposition. All EISCAP systems have a clear pH response, favoring the stacked gate insulators SiO2-Ta2O5 when considering the overall sensor characteristics, while the Si3N4(1 nm)-Ta2O5 stack delivers the largest accumulation capacitance (due to the lower equivalent oxide thickness) and a higher steepness in the slope of the capacitance-voltage curve among the studied stacked gate insulator systems.}, language = {en} } @article{MolinnusJanusFangetal.2022, author = {Molinnus, Denise and Janus, Kevin Alexander and Fang, Anyelina C. and Drinic, Aleksander and Achtsnicht, Stefan and K{\"o}pf, Marius and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Thick-film carbon electrode deposited onto a biodegradable fibroin substrate for biosensing applications}, series = {Physica status solidi (a)}, volume = {219}, journal = {Physica status solidi (a)}, number = {23}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.202200100}, pages = {1 -- 9}, year = {2022}, abstract = {This study addresses a proof-of-concept experiment with a biocompatible screen-printed carbon electrode deposited onto a biocompatible and biodegradable substrate, which is made of fibroin, a protein derived from silk of the Bombyx mori silkworm. To demonstrate the sensor performance, the carbon electrode is functionalized as a glucose biosensor with the enzyme glucose oxidase and encapsulated with a silicone rubber to ensure biocompatibility of the contact wires. The carbon electrode is fabricated by means of thick-film technology including a curing step to solidify the carbon paste. The influence of the curing temperature and curing time on the electrode morphology is analyzed via scanning electron microscopy. The electrochemical characterization of the glucose biosensor is performed by amperometric/voltammetric measurements of different glucose concentrations in phosphate buffer. Herein, systematic studies at applied potentials from 500 to 1200 mV to the carbon working electrode (vs the Ag/AgCl reference electrode) allow to determine the optimal working potential. Additionally, the influence of the curing parameters on the glucose sensitivity is examined over a time period of up to 361 days. The sensor shows a negligible cross-sensitivity toward ascorbic acid, noradrenaline, and adrenaline. The developed biocompatible biosensor is highly promising for future in vivo and epidermal applications.}, language = {en} } @article{MolinnusMuschallikGonzalezetal.2018, author = {Molinnus, Denise and Muschallik, Lukas and Gonzalez, Laura Osorio and Bongaerts, Johannes and Wagner, Torsten and Selmer, Thorsten and Siegert, Petra and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Development and characterization of a field-effect biosensor for the detection of acetoin}, series = {Biosensors and Bioelectronics}, volume = {115}, journal = {Biosensors and Bioelectronics}, publisher = {Elsevier}, address = {Amsterdam}, doi = {10.1016/j.bios.2018.05.023}, pages = {1 -- 6}, year = {2018}, abstract = {A capacitive electrolyte-insulator-semiconductor (EIS) field-effect biosensor for acetoin detection has been presented for the first time. The EIS sensor consists of a layer structure of Al/p-Si/SiO₂/Ta₂O₅/enzyme acetoin reductase. The enzyme, also referred to as butane-2,3-diol dehydrogenase from B. clausii DSM 8716T, has been recently characterized. The enzyme catalyzes the (R)-specific reduction of racemic acetoin to (R,R)- and meso-butane-2,3-diol, respectively. Two different enzyme immobilization strategies (cross-linking by using glutaraldehyde and adsorption) have been studied. Typical biosensor parameters such as optimal pH working range, sensitivity, hysteresis, linear concentration range and long-term stability have been examined by means of constant-capacitance (ConCap) mode measurements. Furthermore, preliminary experiments have been successfully carried out for the detection of acetoin in diluted white wine samples.}, language = {en} } @article{MolinnusPoghossianKeusgenetal.2017, author = {Molinnus, Denise and Poghossian, Arshak and Keusgen, Michael and Katz, Evgeny and Sch{\"o}ning, Michael Josef}, title = {Coupling of Biomolecular Logic Gates with Electronic Transducers: From Single Enzyme Logic Gates to Sense/Act/Treat Chips}, series = {Electroanalysis}, volume = {29}, journal = {Electroanalysis}, number = {8}, publisher = {Wiley}, address = {Weinheim}, issn = {1521-4109}, doi = {10.1002/elan.201700208}, pages = {1840 -- 1849}, year = {2017}, abstract = {The integration of biomolecular logic principles with electronic transducers allows designing novel digital biosensors with direct electrical output, logically triggered drug-release, and closed-loop sense/act/treat systems. This opens new opportunities for advanced personalized medicine in the context of theranostics. In the present work, we will discuss selected examples of recent developments in the field of interfacing enzyme logic gates with electrodes and semiconductor field-effect devices. Special attention is given to an enzyme OR/Reset logic gate based on a capacitive field-effect electrolyte-insulator-semiconductor sensor modified with a multi-enzyme membrane. Further examples are a digital adrenaline biosensor based on an AND logic gate with binary YES/NO output and an integrated closed-loop sense/act/treat system comprising an amperometric glucose sensor, a hydrogel actuator, and an insulin (drug) sensor.}, language = {en} } @article{MolinnusSorichBartzetal.2016, author = {Molinnus, Denise and Sorich, Maren and Bartz, Alexander and Siegert, Petra and Willenberg, Holger S. and Lisdat, Fred and Poghossian, Arshak and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Towards an adrenaline biosensor based on substrate recycling amplification in combination with an enzyme logic gate}, series = {Sensors and Actuators B: Chemical}, volume = {237}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2016.06.064}, pages = {190 -- 195}, year = {2016}, abstract = {An amperometric biosensor using a substrate recycling principle was realized for the detection of low adrenaline concentrations (1 nM) by measurements in phosphate buffer and Ringer's solution at pH 6.5 and pH 7.4, respectively. In proof-of-concept experiments, a Boolean logic-gate principle has been applied to develop a digital adrenaline biosensor based on an enzyme AND logic gate. The obtained results demonstrate that the developed digital biosensor is capable for a rapid qualitative determination of the presence/absence of adrenaline in a YES/NO statement. Such digital biosensor could be used in clinical diagnostics for the control of a correct insertion of a catheter in the adrenal veins during adrenal venous-sampling procedure.}, language = {en} } @inproceedings{MollKoehlerWolf2019, author = {Moll, Florian and K{\"o}hler, Klemens and Wolf, Martin R.}, title = {Konzeption von IT-Sicherheitsl{\"o}sungen unter ethischen Gesichtspunkten am Beispiel einer Monitoring-App f{\"u}r mobile Endger{\"a}te}, series = {Angewandte Forschung in der Wirtschaftsinformatik 2019 : Tagungsband zur 32. AKWI-Jahrestagung}, booktitle = {Angewandte Forschung in der Wirtschaftsinformatik 2019 : Tagungsband zur 32. AKWI-Jahrestagung}, publisher = {mana-Buch}, address = {Heide}, isbn = {978-3-944330-62-4}, pages = {61 -- 72}, year = {2019}, abstract = {Die steigende Popularit{\"a}t von mobilen Endger{\"a}ten im privaten und gesch{\"a}ftlichen Umfeld geht mit einem Anstieg an Sicherheitsl{\"u}cken und somit potentiellen Angriffsfl{\"a}chen einher. Als ein Element der technischen und organisatorischen Maßnahmen zum Schutz eines Netzwerkes k{\"o}nnen Monitoring-Apps dienen, die unerw{\"u}nschtes Verhalten und Angriffe erkennen. Die automatisierte {\"U}berwachung von Endger{\"a}ten ist jedoch rechtlich und ethisch komplex. Dies in Kombination mit einer hohen Sensibilit{\"a}t der Nutzer und Nutzerinnen dieser Ger{\"a}te in Bezug auf Privatsph{\"a}re, kann zu einer geringen Akzeptanz und Compliance f{\"u}hren. Eine datenschutzrechtlich und ethisch einwandfreie Konzeption solcher Apps bereits im Designprozess f{\"u}hrt zu h{\"o}herer Akzeptanz und verbessert so die Effizienz. Diese Analyse beschreibt M{\"o}glichkeiten zur Umsetzung.}, language = {de} } @article{MonakhovaDiehl2021, author = {Monakhova, Yulia and Diehl, Bernd W. K.}, title = {A step towards optimization of the qNMR workflow: proficiency testing exercise at an GxP-accredited laboratory}, series = {Applied Magnetic Resonance}, volume = {52}, journal = {Applied Magnetic Resonance}, publisher = {Springer Nature}, address = {Wien}, issn = {1613-7507}, doi = {10.1007/s00723-021-01324-3}, pages = {581 -- 593}, year = {2021}, abstract = {Quantitative nuclear magnetic resonance (qNMR) is considered as a powerful tool for multicomponent mixture analysis as well as for the purity determination of single compounds. Special attention is currently paid to the training of operators and study directors involved in qNMR testing. To assure that only qualified personnel are used for sample preparation at our GxP-accredited laboratory, weighing test was proposed. Sixteen participants performed six-fold weighing of the binary mixture of dibutylated hydroxytoluene (BHT) and 1,2,4,5-tetrachloro-3-nitrobenzene (TCNB). To evaluate the quality of data analysis, all spectra were evaluated manually by a qNMR expert and using in-house developed automated routine. The results revealed that mean values are comparable and both evaluation approaches are free of systematic error. However, automated evaluation resulted in an approximately 20\% increase in precision. The same findings were revealed for qNMR analysis of 32 compounds used in pharmaceutical industry. Weighing test by six-fold determination in binary mixtures and automated qNMR methodology can be recommended as efficient tools for evaluating staff proficiency. The automated qNMR method significantly increases throughput and precision of qNMR for routine measurements and extends application scope of qNMR.}, language = {en} } @article{MonakhovaDiehl2021, author = {Monakhova, Yulia and Diehl, Bernd W. K.}, title = {Simplification of NMR Workflows by Standardization Using 2H Integral of Deuterated Solvent as Applied to Aloe vera Preparations}, series = {Applied Magnetic Resonance}, volume = {52}, journal = {Applied Magnetic Resonance}, number = {11}, publisher = {Springer}, address = {Cham}, issn = {1613-7507}, doi = {10.1007/s00723-021-01393-4}, pages = {1591 -- 1600}, year = {2021}, abstract = {In this study, a recently proposed NMR standardization approach by 2H integral of deuterated solvent for quantitative multicomponent analysis of complex mixtures is presented. As a proof of principle, the existing NMR routine for the analysis of Aloe vera products was modified. Instead of using absolute integrals of targeted compounds and internal standard (nicotinamide) from 1H-NMR spectra, quantification was performed based on the ratio of a particular 1H-NMR compound integral and 2H-NMR signal of deuterated solvent D2O. Validation characteristics (linearity, repeatability, accuracy) were evaluated and the results showed that the method has the same precision as internal standardization in case of multicomponent screening. Moreover, a dehydration process by freeze drying is not necessary for the new routine. Now, our NMR profiling of A. vera products needs only limited sample preparation and data processing. The new standardization methodology provides an appealing alternative for multicomponent NMR screening. In general, this novel approach, using standardization by 2H integral, benefits from reduced sample preparation steps and uncertainties, and is recommended in different application areas (purity determination, forensics, pharmaceutical analysis, etc.).}, language = {en} } @article{MonakhovaDiehl2021, author = {Monakhova, Yulia and Diehl, Bernd W.K.}, title = {Novel approach of qNMR workflow by standardization using 2H integral: Application to any intrinsic calibration standard}, series = {Talanta}, volume = {222}, journal = {Talanta}, number = {Article number: 121504}, publisher = {Elsevier}, isbn = {0039-9140}, doi = {10.1016/j.talanta.2020.121504}, year = {2021}, abstract = {Quantitative nuclear magnetic resonance (qNMR) is routinely performed by the internal or external standardization. The manuscript describes a simple alternative to these common workflows by using NMR signal of another active nuclei of calibration compound. For example, for any arbitrary compound quantification by NMR can be based on the use of an indirect concentration referencing that relies on a solvent having both 1H and 2H signals. To perform high-quality quantification, the deuteration level of the utilized deuterated solvent has to be estimated. In this contribution the new method was applied to the determination of deuteration levels in different deuterated solvents (MeOD, ACN, CDCl3, acetone, benzene, DMSO-d6). Isopropanol-d6, which contains a defined number of deuterons and protons, was used for standardization. Validation characteristics (precision, accuracy, robustness) were calculated and the results showed that the method can be used in routine practice. Uncertainty budget was also evaluated. In general, this novel approach, using standardization by 2H integral, benefits from reduced sample preparation steps and uncertainties, and can be applied in different application areas (purity determination, forensics, pharmaceutical analysis, etc.).}, language = {en} } @article{MonakhovaDiehl2022, author = {Monakhova, Yulia and Diehl, Bernd W.K.}, title = {Multinuclear NMR screening of pharmaceuticals using standardization by 2H integral of a deuterated solvent}, series = {Journal of Pharmaceutical and Biomedical Analysis}, volume = {209}, journal = {Journal of Pharmaceutical and Biomedical Analysis}, number = {Article number: 114530}, publisher = {Elsevier}, isbn = {0731-7085}, doi = {10.1016/j.jpba.2021.114530}, year = {2022}, abstract = {NMR standardization approach that uses the 2H integral of deuterated solvent for quantitative multinuclear analysis of pharmaceuticals is described. As a proof of principle, the existing NMR procedure for the analysis of heparin products according to US Pharmacopeia monograph is extended to the determination of Na+ and Cl- content in this matrix. Quantification is performed based on the ratio of a 23Na (35Cl) NMR integral and 2H NMR signal of deuterated solvent, D2O, acquired using the specific spectrometer hardware. As an alternative, the possibility of 133Cs standardization using the addition of Cs2CO3 stock solution is shown. Validation characteristics (linearity, repeatability, sensitivity) are evaluated. A holistic NMR profiling of heparin products can now also be used for the quantitative determination of inorganic compounds in a single analytical run using a single sample. In general, the new standardization methodology provides an appealing alternative for the NMR screening of inorganic and organic components in pharmaceutical products.}, language = {en} } @article{MonakhovaDiehl2022, author = {Monakhova, Yulia and Diehl, Bernd W.K.}, title = {Nuclear magnetic resonance spectroscopy as an elegant tool for a complete quality control of crude heparin material}, series = {Journal of Pharmaceutical and Biomedical Analysis}, volume = {219}, journal = {Journal of Pharmaceutical and Biomedical Analysis}, number = {Article number: 114915}, publisher = {Elsevier}, address = {New York, NY}, issn = {0731-7085}, doi = {10.1016/j.jpba.2022.114915}, year = {2022}, abstract = {Nuclear magnetic resonance (NMR) spectrometric methods for the quantitative analysis of pure heparin in crude heparin is proposed. For quantification, a two-step routine was developed using a USP heparin reference sample for calibration and benzoic acid as an internal standard. The method was successfully validated for its accuracy, reproducibility, and precision. The methodology was used to analyze 20 authentic porcine heparinoid samples having heparin content between 4.25 w/w \% and 64.4 w/w \%. The characterization of crude heparin products was further extended to a simultaneous analysis of these common ions: sodium, calcium, acetate and chloride. A significant, linear dependence was found between anticoagulant activity and assayed heparin content for thirteen heparinoids samples, for which reference data were available. A Diffused-ordered NMR experiment (DOSY) can be used for qualitative analysis of specific glycosaminoglycans (GAGs) in heparinoid matrices and, potentially, for quantitative prediction of molecular weight of GAGs. NMR spectrometry therefore represents a unique analytical method suitable for the simultaneous quantitative control of organic and inorganic composition of crude heparin samples (especially heparin content) as well as an estimation of other physical and quality parameters (molecular weight, animal origin and activity).}, language = {en} } @article{MonakhovaSobolevaFedotovaetal.2022, author = {Monakhova, Yulia and Soboleva, Polina M. and Fedotova, Elena S. and Musina, Kristina T. and Burmistrova, Natalia A.}, title = {Quantum chemical calculations of IR spectra of heparin disaccharide subunits}, series = {Computational and Theoretical Chemistry}, volume = {1217}, journal = {Computational and Theoretical Chemistry}, number = {Article number: 113891}, publisher = {Elsevier}, address = {New York, NY}, isbn = {2210-271X}, doi = {10.1016/j.comptc.2022.113891}, year = {2022}, abstract = {Heparin is a natural polysaccharide, which plays essential role in many biological processes. Alterations in building blocks can modify biological roles of commercial heparin products, due to significant changes in the conformation of the polymer chain. The variability structure of heparin leads to difficulty in quality control using different analytical methods, including infrared (IR) spectroscopy. In this paper molecular modelling of heparin disaccharide subunits was performed using quantum chemistry. The structural and spectral parameters of these disaccharides have been calculated using RHF/6-311G. In addition, over-sulphated chondroitin sulphate disaccharide was studied as one of the most widespread contaminants of heparin. Calculated IR spectra were analyzed with respect to specific structure parameters. IR spectroscopic fingerprint was found to be sensitive to substitution pattern of disaccharide subunits. Vibrational assignments of calculated spectra were correlated with experimental IR spectral bands of native heparin. Chemometrics was used to perform multivariate analysis of simulated spectral data.}, language = {en} } @misc{Monse2021, type = {Master Thesis}, author = {Monse, Henry}, title = {(K)eine Opposition: Die Wahlkampfgestaltung der SPD und CDU von 1945—1990 im historischen Kontext}, publisher = {FH Aachen}, address = {Aachen}, pages = {66 Seiten}, year = {2021}, abstract = {Im Zentrum des Buches stehen die beiden Volksparteien CDU und SPD, die sich als gegens{\"a}tzliche, gar verfeindete Parteien startend, gegenw{\"a}rtig in ihren visuellen und inhaltlichen Identit{\"a}ten immer unerkenntlicher vermischen. Das Buch geht dem Ursprung dieser Vermischung auf die Spur und untersucht inwiefern sich die visuellen Identit{\"a}ten der beiden Parteien zwischen 1945 und 1990 in Form der Gestaltung nach außen aneinander angeglichen haben und wer wann federf{\"u}hrend in der Gestaltung war. Beginnend 1945 in der »Stunde Null« f{\"u}hrt das Buch in den einzelnen Kapiteln durch das Zeitgeschehen der Bundesrepublik bis ins Jahr 1990. Der historische Querschnitt beleuchtet dabei das gesellschaftspolitische Zeitgeschehen, das den Wahlk{\"a}mpfen zugrunde liegt. Dabei stehen die politischen Wahlplakate im Fokus der Untersuchung: SPD und CDU — (k)eine gestalterische Opposition?}, language = {de} } @article{MontiWaldvogelRitzmannetal.2021, author = {Monti, Elena and Waldvogel, Janice and Ritzmann, Ramona and Freyler, Kathrin and Albracht, Kirsten and Helm, Michael and De Cesare, Niccol{\`o} and Pavan, Piero and Reggiani, Carlo and Gollhofer, Albert and Narici, Marco Vincenzo}, title = {Muscle in variable gravity: "I do not know where I am, but I know what to do"}, series = {Frontiers in Physiology}, volume = {12}, journal = {Frontiers in Physiology}, publisher = {Frontiers Research Foundation}, address = {Lausanne}, issn = {1664-042X}, doi = {10.3389/fphys.2021.714655}, pages = {19 Seiten}, year = {2021}, abstract = {Performing tasks, such as running and jumping, requires activation of the agonist and antagonist muscles before (motor unit pre-activation) and during movement performance (Santello and Mcdonagh, 1998). A well-timed and regulated muscle activation elicits a stretch-shortening cycle (SSC) response, naturally occurring in bouncing movements (Ishikawa and Komi, 2004; Taube et al., 2012). By definition, the SSC describes the stretching of a pre-activated muscle-tendon complex immediately followed by a muscle shortening in the concentric push-off phase (Komi, 1984). Given the importance of SSC actions for human movement, it is not surprising that many studies investigated the biomechanics of this phenomenon; in particular, drop jumps (DJs) represent a good paradigm to study muscle fascicle and tendon behavior in ballistic movements involving the SSC. Within a DJ, three main phases [pre-activation, braking, and push-off (PO; Komi, 2000)] have been recognized and extensively studied in common and challenging conditions, such as changes in load, falling height, or simulated hypo-gravity (Avela et al., 1994; Arampatzis et al., 2001; Fukashiro et al., 2005; Ishikawa et al., 2005; Sousa et al., 2007; Ritzmann et al., 2016; Helm et al., 2020). These studies show that the timing and amount of triceps-surae muscle-tendon unit pre-activation in DJs are differentially regulated based on the load applied to the muscle, being optimal in normal "Earth" gravity conditions (Avela et al., 1994), but decreased in simulated hypo-gravity, hyper-gravity (Avela et al., 1994; Ritzmann et al., 2016), or unknown conditions (i.e., unknown falling heights; Helm et al., 2020). Some authors indicated that, when falling from heights different from the optimal one [defined as the drop height giving a maximum DJ performance indicated as peak ground reaction force (GRF) or jump high], electromyographic (EMG) activity of the plantar flexors increases from lower than optimal to higher than optimal heights (Ishikawa and Komi, 2004; Sousa et al., 2007). These findings highlight the ability of the central nervous system to regulate the timing and amount of pre-activation according to different jumping conditions, thus regulating muscle fascicle length, tendon and joint stiffness as well as position, in order to safely land on the ground and quickly re-bounce. Similarly, to pre-activation, also in the braking phase, the plantar flexors are differentially regulated. In optimal height (i.e., load) jumping conditions, gastrocnemius medialis (GM) fascicles shorten at early ground contact (possibly due to the intervention of the stretch reflex; Gollhofer et al., 1992) and behave quasi-isometrically in the late braking phase, enabling tendon elongation, and storage of elastic energy (Gollhofer et al., 1992; Fukashiro et al., 2005; Sousa et al., 2007). When increasing the falling height (augmenting the impact GRF), the quasi-isometric behavior of fascicles disappears, and fast fascicle lengthening occurs (Ishikawa et al., 2005; Sousa et al., 2007). In the third and last PO phase, fascicles shorten and the tendon releases the elastic energy previously stored. Bobbert et al. (1987) reported no influence of jumping height on the work done and on the net vertical impulse assessed during PO; this observation suggests that, despite an optimal DJ performance might be achieved only in specific conditions (falling heights, loads), the central nervous system seems to be able to regulate muscle behavior in order to effectively perform the required task also in challenging situations. Although the regulation of triceps-surae muscle-tendon unit in DJs has been extensively investigated, very few studies focused on sarcomeres behavior during the performance of this SSC movement (Kurokawa et al., 2003; Fukashiro et al., 2005, 2006). Sarcomeres represent muscle contractile units and are known to express different amounts of force depending on their length (Gordon et al., 1966; Walker and Schrodt, 1974); thus, understanding the time course of their responses during DJs is fundamental to gain further insights into muscle force-generating capacity. In vivo measurement of sarcomere length in humans has been so far been performed only in static positions and under highly controlled experimental conditions (Llewellyn et al., 2008; Sanchez et al., 2015). Instead, human sarcomere length estimation (achieved by dividing GM measured fascicle length for a fixed sarcomere number) in dynamic contractions provided an indirect measure of sarcomere operating range during squat jump, countermovement jump, and DJ (Fukashiro et al., 2005, 2006; Kurokawa et al., 2003). The results of these studies showed that sarcomeres operate in the ascending limb of their length-tension (L-T) relationship in all types of jumps, and particularly so in DJ. However, most of the available observations on sarcomere and muscle fascicle behavior were made in condition of constant gravity. Thus, in order to understand how sarcomere and muscle fascicle length are regulated in variable gravity conditions, we performed experiments in a parabolic flight, involving variable gravity levels, ranging from about zero-g to about double the Earth's gravity (1 g; Waldvogel et al., 2021). Specifically, the aims of the present study were as follows: 1. To investigate the ability of the neuromuscular system in regulating fascicle length in response to conditions of variable gravity. 2. To estimate sarcomere operative length in the different DJ phases, in order to calculate its theoretical force production and its possible modulation in conditions of variable gravity. We hypothesized that muscle fascicles would be differentially regulated in different gravity conditions compared to 1 g, particularly in anticipation of landing and re-bouncing in unknown gravity levels. In addition, we hypothesized that sarcomeres would operate in the upper part of the ascending limb of their L-T relationship, possibly lengthening during the braking phase (especially in hyper-gravity) while operating quasi-isometrically in 1 g.}, language = {en} } @article{MoorkampPetersonUibel2016, author = {Moorkamp, Wilfried and Peterson, Leif Arne and Uibel, Thomas}, title = {Mit guten Aussichten. Bericht {\"u}ber den Studiengang Holzingenieurwesen an der FH Aachen}, series = {Bauen mit Holz}, journal = {Bauen mit Holz}, number = {5}, publisher = {Rudolf M{\"u}ller}, address = {K{\"o}ln}, issn = {0005-6545}, pages = {33 -- 36}, year = {2016}, language = {de} } @incollection{MoorkampPetersonUibel2022, author = {Moorkamp, Wilfried and Peterson, Leif Arne and Uibel, Thomas}, title = {Nachhaltige Holzbr{\"u}cken f{\"u}r Geh- und Radwege}, series = {Bauphysik Kalender 2022: Holzbau, 22. Jahrgang}, booktitle = {Bauphysik Kalender 2022: Holzbau, 22. Jahrgang}, editor = {Fouad, Nabil A.}, publisher = {Ernst \& Sohn}, address = {Berlin}, isbn = {9783433033609 (Print)}, doi = {10.1002/9783433611081.ch17}, pages = {574 -- 592}, year = {2022}, abstract = {Am Lehr- und Forschungsgebiet Holzbau der Fachhochschule Aachen wurden im Rahmen des Forschungsvorhabens „Nachhaltige Standardbr{\"u}cken in Holzbauweise" Standardtypen f{\"u}r Geh- und Radwegbr{\"u}cken entwickelt. Die Br{\"u}cken sind durch konsequente Umsetzungen von Maßnahmen des konstruktiven Holzschutzes f{\"u}r eine Nutzung von mehr als 80~Jahren konzipiert. Innovative L{\"o}sungen f{\"u}r Bauteile und Anschl{\"u}sse sowie Materialalternativen im Bereich des Belages und der Gel{\"a}nder erm{\"o}glichen eine wartungsarme Konstruktion und tragen somit zur Wirtschaftlichkeit und Nachhaltigkeit bei. Um den Einsatz der entwickelten Standardbr{\"u}ckentypen in der Praxis zu erleichtern, wurden Leistungsverzeichnisse, Musterstatiken, Musterzeichnungen und umfangreiche Detailkataloge als Unterst{\"u}tzung f{\"u}r Planer und Bauherren erstellt. Damit die Randbedingungen f{\"u}r eine lange Lebensdauer w{\"a}hrend der Nutzung der Br{\"u}cke erhalten bleiben, wurden Leitf{\"a}den f{\"u}r die Pflege und Wartung sowie f{\"u}r die Br{\"u}ckenpr{\"u}fung erarbeitet. Der Beitrag gibt Einblicke in das Forschungsvorhaben und seine Resultate.}, language = {de} } @incollection{MoorkampPetersonUibel2023, author = {Moorkamp, Wilfried and Peterson, Leif Arne and Uibel, Thomas}, title = {Standardholzbr{\"u}cken f{\"u}r kommunale Geh- und Radwege}, series = {Strukturen, Formen und Prinzipien : Festschrift zum 60. Geburtstag von Univ.-Prof. Dr.-Ing. Martin Trautz}, booktitle = {Strukturen, Formen und Prinzipien : Festschrift zum 60. Geburtstag von Univ.-Prof. Dr.-Ing. Martin Trautz}, editor = {Wehren, Cedric}, publisher = {RWTH Aachen}, address = {Aachen}, isbn = {978-3-95886-500-6}, pages = {140 -- 165}, year = {2023}, language = {de} } @article{Moosdorf2009, author = {Moosdorf, Andreas}, title = {It's not just the Talent, it's the Knowledge Transfer Method}, series = {GC Ticker}, journal = {GC Ticker}, number = {1}, pages = {16 -- 16}, year = {2009}, language = {en} } @book{Moosdorf2008, author = {Moosdorf, Andreas}, title = {The determinants of international knowledge transfer effectiveness - conceptual advances and empirical verification}, year = {2008}, language = {en} } @article{MootzMerschenzQuack1987, author = {Mootz, D. and Merschenz-Quack, Angelika}, title = {Zur Kenntnis der h{\"o}chsten Hydrate der Schwefels{\"a}ure: Bildung und Struktur von H2SO4·6,5 H2O und H2SO4·8H2O}, series = {Zeitschrift f{\"u}r Naturforschung B: Journal of chemical sciences}, volume = {42}, journal = {Zeitschrift f{\"u}r Naturforschung B: Journal of chemical sciences}, number = {H. 10}, issn = {1865-7117 (E-Journal); 0932-0776 (Print)}, pages = {1231 -- 1236}, year = {1987}, language = {de} } @article{MoraisGomesSilvaetal.2017, author = {Morais, Paulo V. and Gomes, Vanderley F., Jr. and Silva, Anielle C. A. and Dantas, Noelio O. and Sch{\"o}ning, Michael Josef and Siqueira, Jos{\´e} R., Jr.}, title = {Nanofilm of ZnO nanocrystals/carbon nanotubes as biocompatible layer for enzymatic biosensors in capacitive field-effect devices}, series = {Journal of Materials Science}, volume = {52}, journal = {Journal of Materials Science}, number = {20}, publisher = {Springer}, address = {Berlin}, issn = {1573-4803}, doi = {10.1007/s10853-017-1369-y}, pages = {12314 -- 12325}, year = {2017}, abstract = {The incorporation of nanomaterials that are biocompatible with different types of biological compounds has allowed the development of a new generation of biosensors applied especially in the biomedical field. In particular, the integration of film-based nanomaterials employed in field-effect devices can be interesting to develop biosensors with enhanced properties. In this paper, we studied the fabrication of sensitive nanofilms combining ZnO nanocrystals and carbon nanotubes (CNTs), prepared by means of the layer-by-layer (LbL) technique, in a capacitive electrolyte-insulator-semiconductor (EIS) structure for detecting glucose and urea. The ZnO nanocrystals were incorporated in a polymeric matrix of poly(allylamine) hydrochloride (PAH), and arranged with multi-walled CNTs in a LbL PAH-ZnO/CNTs film architecture onto EIS chips. The electrochemical characterizations were performed by capacitance-voltage and constant capacitance measurements, while the morphology of the films was characterized by atomic force microscopy. The enzymes glucose oxidase and urease were immobilized on film's surface for detection of glucose and urea, respectively. In order to obtain glucose and urea biosensors with optimized amount of sensitive films, we investigated the ideal number of bilayers for each detection system. The glucose biosensor showed better sensitivity and output signal for an LbL PAH-ZnO/CNTs nanofilm with 10 bilayers. On the other hand, the urea biosensor presented enhanced properties even for the first bilayer, exhibiting high sensitivity and output signal. The presence of the LbL PAH-ZnO/CNTs films led to biosensors with better sensitivity and enhanced response signal, demonstrating that the adequate use of nanostructured films is feasible for proof-of-concept biosensors with improved properties that may be employed for biomedical applications.}, language = {en} }