@article{WeckesserHufnagelZiemonsetal.1997, author = {Weckesser, Matthias and Hufnagel, Andreas and Ziemons, Karl and Grießmeier, Martin and Sonnenberg, Frank and Hackl{\"a}nder, Thomas and Langen, Karl-J. and Holschbach, Markus and Elger, Christian E. and M{\"u}ller-G{\"a}rtner, Hans-W.}, title = {Effect of partial volume correction on muscarinic cholinergic receptor imaging with single-photon emission tomography in patients with temporal lobe epilepsy}, series = {European Journal of Nuclear Medicine}, volume = {24}, journal = {European Journal of Nuclear Medicine}, number = {9}, isbn = {1619-7089}, pages = {1156 -- 1161}, year = {1997}, abstract = {Animal experiments and preliminary results in humans have indicated alterations of hippocampal muscarinic acetylcholine receptors (mAChR) in temporal lobe epilepsy. Patients with temporal lobe epilepsy often present with a reduction in hippocampal volume. The aim of this study was to investigate the influence of hippocampal atrophy on the quantification of mAChR with single photon emission tomography (SPET) in patients with temporal lobe epilepsy. Cerebral uptake of the muscarinic cholinergic antagonist [123I]4-iododexetimide (IDex) was investigated by SPET in patients suffering from temporal lobe epilepsy of unilateral (n=6) or predominantly unilateral (n=1) onset. Regions of interest were drawn on co-registered magnetic resonance images. Hippocampal volume was determined in these regions and was used to correct the SPET results for partial volume effects. A ratio of hippocampal IDex binding on the affected side to that on the unaffected side was used to detect changes in muscarinic cholinergic receptor density. Before partial volume correction a decrease in hippocampal IDex binding on the focus side was found in each patient. After partial volume no convincing differences remained. Our results indicate that the reduction in hippocampal IDex binding in patients with epilepsy is due to a decrease in hippocampal volume rather than to a decrease in receptor concentration.}, language = {en} } @article{SchmidtLangenHerzogetal.1997, author = {Schmidt, Daniela and Langen, Karl-J. and Herzog, Hans and Wirths, Jochen and Holschbach, Markus and Kiwit, J{\"u}rgen C. W. and Ziemons, Karl and Coenen, Heinz-H. and M{\"u}ller-G{\"a}rtner, Hans-W.}, title = {Whole-body kinetics and dosimetry of L-3[123I]-iodo-α-methyltyrosine}, series = {European Journal of Nuclear Medicine}, volume = {24}, journal = {European Journal of Nuclear Medicine}, number = {9}, isbn = {1619-7089}, pages = {1162 -- 1166}, year = {1997}, language = {en} } @article{WeckesserGriessmeierSchmidtetal.1998, author = {Weckesser, Martin and Grießmeier, Martin and Schmidt, Daniela and Sonnenberg, Frank and Ziemons, Karl and Kemna, Lars and Holschbach, Marcus and Langen, Karl-J. and M{\"u}ller-G{\"a}rtner, Hans-W.}, title = {Iodine-123 α-methyl tyrosine single-photon emission tomography of cerebral gliomas: standardised evaluation of tumour uptake and extent}, series = {European Journal of Nuclear Medicine}, volume = {25}, journal = {European Journal of Nuclear Medicine}, number = {2}, isbn = {1619-7089}, pages = {150 -- 156}, year = {1998}, abstract = {Single-photon emission tomography (SPET) with the amino acid analogue l-3-[123I]iodo-α-methyl tyrosine (IMT) is helpful in the diagnosis and monitoring of cerebral gliomas. Radiolabelled amino acids seem to reflect tumour infiltration more specifically than conventional methods like magnetic resonance imaging and computed tomography. Automatic tumour delineation based on maximal tumour uptake may cause an overestimation of mean tumour uptake and an underestimation of tumour extension in tumours with circumscribed peaks. The aim of this study was to develop a program for tumour delineation and calculation of mean tumour uptake which takes into account the mean background activity and is thus optimised to the problem of tumour definition in IMT SPET. Using the frequency distribution of pixel intensities of the tomograms a program was developed which automatically detects a reference brain region and draws an isocontour region around the tumour taking into account mean brain radioactivity. Tumour area and tumour/brain ratios were calculated. A three-compartment phantom was simulated to test the program. The program was applied to IMT SPET studies of 20 patients with cerebral gliomas and was compared to the results of manual analysis by three different investigators. Activity ratios and chamber extension of the phantom were correctly calculated by the automatic analysis. A method based on image maxima alone failed to determine chamber extension correctly. Manual region of interest analysis in patient studies resulted in a mean inter-observer standard deviation of 8.7\%±6.1\% (range 2.7\%-25.0\%). The mean value of the results of the manual analysis showed a significant correlation to the results of the automatic analysis (r = 0.91, P<0.0001 for the uptake ratio; r = 0.87, P<0.0001 for the tumour area). We conclude that the algorithm proposed simplifies the calculation of uptake ratios and may be used for observer-independent evaluation of IMT SPET studies. Three-dimensional tumour recognition and transfer to co-registered morphological images based on this program may be useful for the planning of surgical and radiation treatment.}, language = {en} } @article{TaylorSchmitzZiemonsetal.2000, author = {Taylor, J. G. and Schmitz, N. and Ziemons, Karl and Grosse-Ruyken, M.-L. and Gruber, O. and M{\"u}ller-G{\"a}rtner, H.-W. and Shah, N. J.}, title = {The network of brain areas involved in the motion aftereffect}, series = {Neuroimage}, volume = {11}, journal = {Neuroimage}, number = {4}, isbn = {1053-8119}, pages = {257 -- 270}, year = {2000}, abstract = {A network of brain areas is expected to be involved in supporting the motion aftereffect. The most active components of this network were determined by means of an fMRI study of nine subjects exposed to a visual stimulus of moving bars producing the effect. Across the subjects, common areas were identified during various stages of the effect, as well as networks of areas specific to a single stage. In addition to the well-known motion-sensitive area MT the prefrontal brain areas BA44 and 47 and the cingulate gyrus, as well as posterior sites such as BA37 and BA40, were important components during the period of the motion aftereffect experience. They appear to be involved in control circuitry for selecting which of a number of processing styles is appropriate. The experimental fMRI results of the activation levels and their time courses for the various areas are explored. Correlation analysis shows that there are effectively two separate and weakly coupled networks involved in the total process. Implications of the results for awareness of the effect itself are briefly considered in the final discussion.}, language = {en} } @article{FinkMarshallShahetal.2000, author = {Fink, G. R. and Marshall, J. C. and Shah, N. J. and Weiss, P.H. and Halligan, P. W. and Grosse-Ruyken, M. and Ziemons, Karl and Zilles, K. and Freund, H. J.}, title = {Line bisection judgments implicate right parietal cortex and cerebellum as assessed by fMRI}, series = {Neurology}, volume = {54}, journal = {Neurology}, number = {6}, isbn = {1526-632X}, pages = {1324 -- 1331}, year = {2000}, language = {en} } @article{StreunBrandenburgLarueetal.2000, author = {Streun, M. and Brandenburg, G. and Larue, H. and Zimmermann, E. and Ziemons, Karl and Halling, H.}, title = {Pulse recording by free-running sampling}, series = {2000 IEEE Nuclear Science Symposium Conference Record, Vol. 2}, journal = {2000 IEEE Nuclear Science Symposium Conference Record, Vol. 2}, issn = {1082-3654}, pages = {9/179 -- 9/181}, year = {2000}, abstract = {Pulses from a position-sensitive photomultiplier (PS-PMT) are recorded by free running ADCs at a sampling rate of 40 MHz. A four-channel acquisition-board has been developed which is equipped with four 12 bit-ADCs connected to one FPGA (field programmable gate array). The FPGA manages data acquisition and the transfer to the host computer. It can also work as a digital trigger, so a separate hardware-trigger can be omitted. The method of free running sampling provides a maximum of information, besides the pulse charge and amplitude also pulse shape and starting time are contained in the sampled data. These informations are crucial for many tasks such as distinguishing between different scintillator materials, determination of radiation type, pile-up recovery, coincidence detection or time-of-flight applications. The absence of an analog integrator allows coping with very high count rates. Since this method is going to be employed in positron emission tomography (PET), the position of an event is another important information. The simultaneous readout of four channels allows localization by means of center-of-gravity weighting. First results from a test setup with LSO-scintillators coupled to the PS-PMT are presented}, language = {en} } @article{WernerTakenagaTakietal.2013, author = {Werner, Frederik and Takenaga, Shoko and Taki, Hidenori and Sawada, Kazuaki and Sch{\"o}ning, Michael Josef}, title = {Comparison of label-free ACh-imaging sensors based on CCD and LAPS}, series = {Sensors and Actuators B: Chemical (2012)}, volume = {177}, journal = {Sensors and Actuators B: Chemical (2012)}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {0925-4005}, pages = {745 -- 752}, year = {2013}, abstract = {Semiconductor-based chemical imaging sensors, like the light-addressable potentiometric sensor (LAPS) or the pH-imaging sensor based on a charge-coupled device (CCD), are becoming a powerful tool for label-free imaging of biological phenomena. We have proposed a polyion-based enzymatic membrane to develop an acetylcholine (ACh) imaging sensor for neural cell-activity observations. In this study, a CCD-type ACh-imaging sensor and a LAPS-type ACh-imaging sensor were fabricated and the prospect of both sensors was clarified by making a comparison of their basic characteristics.}, language = {en} } @article{KirchnerOberlaenderSucoetal.2013, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Suco, Henri-Pierre and Rysstad, Gunnar and Sch{\"o}ning, Michael Josef}, title = {Monitoring the microbicidal effectiveness of gaseous hydrogen peroxide in sterilisation processes by means of a calorimetric gas sensor}, series = {Food control}, volume = {31}, journal = {Food control}, number = {2}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0956-7135}, doi = {10.1016/j.foodcont.2012.11.048}, pages = {530 -- 538}, year = {2013}, abstract = {In the present work, a novel method for monitoring sterilisation processes with gaseous H2O2 in combination with heat activation by means of a specially designed calorimetric gas sensor was evaluated. Therefore, the sterilisation process was extensively studied by using test specimens inoculated with Bacillus atrophaeus spores in order to identify the most influencing process factors on its microbicidal effectiveness. Besides the contact time of the test specimens with gaseous H2O2 varied between 0.2 and 0.5 s, the present H2O2 concentration in a range from 0 to 8\% v/v (volume percent) had a strong influence on the microbicidal effectiveness, whereas the change of the vaporiser temperature, gas flow and humidity were almost negligible. Furthermore, a calorimetric H2O2 gas sensor was characterised in the sterilisation process with gaseous H2O2 in a wide range of parameter settings, wherein the measurement signal has shown a linear response against the H2O2 concentration with a sensitivity of 4.75 °C/(\% v/v). In a final step, a correlation model by matching the measurement signal of the gas sensor with the microbial inactivation kinetics was established that demonstrates its suitability as an efficient method for validating the microbicidal effectiveness of sterilisation processes with gaseous H2O2.}, language = {en} } @article{Ziemons1987, author = {Ziemons, Karl}, title = {Jet production and fragmentation properties in deep inelastic muon scattering}, series = {Zeitschrift f{\"u}r Physik C : Particles and Fields}, volume = {36}, journal = {Zeitschrift f{\"u}r Physik C : Particles and Fields}, number = {4}, isbn = {0170-9739}, pages = {527 -- 543}, year = {1987}, language = {en} } @article{Ziemons1988, author = {Ziemons, Karl}, title = {A measurement of the spin asymmetry of the structure function g1 in deep inelastic muon-proton scattering}, series = {Physics Letters B}, volume = {206}, journal = {Physics Letters B}, number = {2}, isbn = {0370-2693}, pages = {364 -- 370}, year = {1988}, abstract = {The spin asymmetry in deep inelastic scattering of longitudinally polarised muons by longitudinally polarised protons has been measured over a large x range (0.01}, publisher = {Forschungszentrum J{\"u}lich}, address = {J{\"u}lich}, isbn = {3-00-009057-6}, pages = {V, 548 S. : graph. Darst.}, year = {2002}, language = {en} } @book{Grotendorst2002, author = {Grotendorst, Johannes}, title = {Quantum simulations of complex many-body systems: from theory to algorithms : winter school, 25 February - 1 March 2002, Rolduc Conference Centre, Kerkrade, the Netherlands ; poster presentations / ed. by Johannes Grotendorst}, publisher = {NIC}, address = {J{\"u}lich}, isbn = {3-00-009058-4}, year = {2002}, language = {en} } @book{Grotendorst2002, author = {Grotendorst, Johannes}, title = {Quantum Simulations of Complex Many-Body Systems: From Theory to Algorithms, Audio-Visual Lecture Notes / Grotendorst, Johannes [Ed.]}, publisher = {NIC}, address = {J{\"u}lich}, isbn = {3-00-010000-8}, pages = {DVD}, year = {2002}, language = {en} } @book{Grotendorst2000, author = {Grotendorst, Johannes}, title = {Workshop on Molecular Dynamics on Parallel Computers John von Neumann Institute for Computing (NIC), Research Centre J{\"u}lich, Germany 8 - 10 February 1999}, publisher = {World Scientific}, address = {Singapore}, isbn = {981-02-4232-8}, pages = {XI, 379 S. : Ill., graph. Darst.}, year = {2000}, language = {en} } @book{Grotendorst2000, author = {Grotendorst, Johannes}, title = {Modern methods and algorithms of quantum chemistry : winter school, 21 - 25 February 2000, Forschungszentrum J{\"u}lich, Germany ; proceedings / organized by John-von-Neumann-Institute for Computing (NIC). Ed. by Johannes Grotendorst ... 2. ed.}, publisher = {NIC}, address = {J{\"u}lich}, isbn = {3-00-005834-6}, pages = {IV, 638 S. : graph. Darst.}, year = {2000}, language = {en} } @book{Grotendorst2000, author = {Grotendorst, Johannes}, title = {Modern methods and algorithms of quantum chemistry : winter school, 21 - 25 February 2000, Forschungszentrum J{\"u}lich, Germany ; proceedings / organized by John-von-Neumann-Institute for Computing (NIC). Ed. by Johannes Grotendorst ...}, publisher = {NIC}, address = {J{\"u}lich}, isbn = {3-00-005618-1}, pages = {IV, 562 S.}, year = {2000}, language = {en} } @book{Grotendorst2000, author = {Grotendorst, Johannes}, title = {Modern methods and algorithms of quantum chemistry : winter school, 21 - 25 February 2000, Forschungszentrum J{\"u}lich, Germany ; Poster Presentations / organized by John-von-Neumann-Institute for Computing (NIC). Ed. by Johannes Grotendorst ...}, publisher = {NIC}, address = {J{\"u}lich}, isbn = {3-00-005746-3}, pages = {77 S.}, year = {2000}, language = {en} } @article{GrotendorstDornseiffer2000, author = {Grotendorst, Johannes and Dornseiffer, J{\"u}rgen}, title = {Computer-aided Modelling and Simulation of the Thermodynamics of Steam Reforming / Grotendorst, Johannes ; Dornseiffer, J{\"u}rgen}, series = {Mathematics and Computers in Simulation. 51 (2000), H. 5}, journal = {Mathematics and Computers in Simulation. 51 (2000), H. 5}, isbn = {0378-4754}, pages = {451 -- 471}, year = {2000}, language = {en} } @article{GrotendorstSchoberthChapmanetal.1996, author = {Grotendorst, Johannes and Schoberth, S. M. and Chapman, B. E. and Kuchel, P. W.}, title = {Ethanol Transport in Zymomonas mobilis Measured by Using in Vivo Nuclear Magnetic Resonance Spin Transfer / Schoberth, S. M. ; Chapman, B. E. ; Kuchel, P. W. ; Wittig, R. M. ; Grotendorst, Johannes ; Jansen, Paul ; Graaf, A. A. de}, series = {Journal of Bacteriology. 178 (1996), H. 6}, journal = {Journal of Bacteriology. 178 (1996), H. 6}, isbn = {0021-9193}, pages = {1756 -- 1761}, year = {1996}, language = {en} } @article{GrotendorstShuangRenHalling1996, author = {Grotendorst, Johannes and Shuang-Ren, Zhao and Halling, Horst}, title = {Calculation of the Potential Distribution for a Three-Layer Spherical Volume Conductor / Shuang-Ren, Zhao ; Grotendorst, Johannes ; Halling, Horst}, series = {MapleTech . 2 (1996), H. 1}, journal = {MapleTech . 2 (1996), H. 1}, isbn = {1061-5733}, pages = {59 -- 66}, year = {1996}, language = {en} } @book{Grotendorst1994, author = {Grotendorst, Johannes}, title = {Calculation of Chemical Equilibrium Compositions : Interner Bericht}, publisher = {Forschungszentrum J{\"u}lich}, address = {J{\"u}lich}, pages = {11 S.}, year = {1994}, language = {en} } @book{GrotendorstDornseifferSchoberth1994, author = {Grotendorst, Johannes and Dornseiffer, J{\"u}rgen and Schoberth, Siegfried M.}, title = {Symbolic-numeric computation techniques for problem-solving in Physical Chemistry and Biochemistry . Stand 08.06.1994 / Grotendorst, Johannes ; Dornseiffer, J{\"u}rgen ; Schoberth, Siegfried M.}, publisher = {ZAM, KFA}, address = {J{\"u}lich}, pages = {9 S.}, year = {1994}, language = {en} } @book{GrotendorstDornseifferSchoberth1994, author = {Grotendorst, Johannes and Dornseiffer, J{\"u}rgen and Schoberth, Siegfried M.}, title = {Symbolic-numeric computation techniques for problem-solving in Physical Chemistry and Biochemistry . Stand 08.06.1994 / Grotendorst, Johannes ; Dornseiffer, J{\"u}rgen ; Schoberth, Siegfried M.}, publisher = {ZAM, KFA}, address = {J{\"u}lich}, pages = {9 S.}, year = {1994}, language = {en} } @article{GrotendorstJansenSchoberth1993, author = {Grotendorst, Johannes and Jansen, Paul and Schoberth, Siegfried}, title = {On Solving the McConnell Equations in Biochemistry / Grotendorst, Johannes ; Jansen, Paul ; Schoberth, Siegfried}, series = {MapleTech. 1 (1993)}, journal = {MapleTech. 1 (1993)}, isbn = {1061-5733}, pages = {56 -- 62}, year = {1993}, language = {en} } @article{Grotendorst1992, author = {Grotendorst, Johannes}, title = {Algorithms of mixed symbolic-numeric type for rational approximation}, series = {Artificial intelligence, expert systems and symbolic computing : selected and revised papers from the IMACS 13th World Congress [on Computation and Applied Mathematics], Dublin, Ireland, July 1991 / ed. by Elias N. Houstis ...}, journal = {Artificial intelligence, expert systems and symbolic computing : selected and revised papers from the IMACS 13th World Congress [on Computation and Applied Mathematics], Dublin, Ireland, July 1991 / ed. by Elias N. Houstis ...}, publisher = {North-Holland}, address = {Amsterdam}, isbn = {0-444-89703-8}, pages = {145 -- 154}, year = {1992}, language = {en} } @article{Grotendorst1991, author = {Grotendorst, Johannes}, title = {A Maple package for transforming series, sequences and functions}, series = {Computer Physics Communications. 67 (1991), H. 2}, journal = {Computer Physics Communications. 67 (1991), H. 2}, isbn = {0010-4655}, pages = {325 -- 342}, year = {1991}, language = {en} } @article{Grotendorst1990, author = {Grotendorst, Johannes}, title = {Approximating functions by means of symbolic computation and a general extrapolation method}, series = {Computer Physics Communications. 59 (1990), H. 2}, journal = {Computer Physics Communications. 59 (1990), H. 2}, isbn = {0010-4655}, pages = {289 -- 301}, year = {1990}, language = {en} } @article{AminTemizArtmannArtmannetal.2009, author = {Amin, Rashid and Temiz Artmann, Ayseg{\"u}l and Artmann, Gerhard and Lazarovici, Philip and Lelkes, Peter I.}, title = {Permeability of an In Vitro Model of Blood Brain Barrier (BBB)}, series = {13th International Conference on Biomedical Engineering / Lim, Chwee Teck [Ed.]}, journal = {13th International Conference on Biomedical Engineering / Lim, Chwee Teck [Ed.]}, isbn = {978-3-540-92841-6}, pages = {81 -- 84}, year = {2009}, language = {en} } @article{BehnamBeckerWeber2011, author = {Behnam, S. and Becker, A. and Weber, Hans-Joachim}, title = {Clinical benefit and cost-efficiency of minimized perfusion circuits for extracorporeal circulation during cardiac surgery}, series = {Zeitschrift f{\"u}r Herz-, Thorax- und Gef{\"a}ßchirurgie}, volume = {25}, journal = {Zeitschrift f{\"u}r Herz-, Thorax- und Gef{\"a}ßchirurgie}, number = {5}, publisher = {Springer}, address = {Berlin}, issn = {0930-9225}, pages = {305 -- 306}, year = {2011}, language = {en} } @article{WagnerMiyamotoWerneretal.2011, author = {Wagner, Torsten and Miyamoto, K. and Werner, Frederik and Sch{\"o}ning, Michael Josef and Yoshinobu, T.}, title = {Flexible electrochemical imaging with "zoom-in" functionality by using a new type of light-addressable potentiometric sensor}, publisher = {IEEE}, address = {New York}, pages = {2133 -- 2135}, year = {2011}, language = {en} } @article{MiyamotoWagnerSchoeningetal.2011, author = {Miyamoto, K. and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, T.}, title = {Multi-well structure for cell culture on the chemical imaging sensor}, publisher = {IEEE}, address = {New York}, pages = {2130 -- 2132}, year = {2011}, language = {en} } @article{SpelthahnKirsanovLeginetal.2012, author = {Spelthahn, Heiko and Kirsanov, Dmitry and Legin, Andrey and Osterrath, Thomas and Schubert, J{\"u}rgen and Zander, Willi and Sch{\"o}ning, Michael Josef}, title = {Development of a thin-film sensor array for analytical monitoring of heavy metals in aqueous solutions}, series = {Physica Status Solidi (a)}, volume = {209}, journal = {Physica Status Solidi (a)}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, isbn = {1862-6319}, doi = {10.1002/pssa.201100733}, pages = {885 -- 891}, year = {2012}, abstract = {In industrial processes there is a variety of heavy metals (e.g., copper, zinc, cadmium, and lead) in use for wires, coatings, paints, alloys, batteries, etc. Since the application of these transition metals for industry is inevitable, it is a vital task to develop proper analytical techniques for their monitoring at low activity levels, especially because most of these elements are acutely toxic for biological organisms. The determination of ions in solution by means of a simple and inexpensive sensor array is, therefore, a promising task. In this work, a sensor array with heavy metal-sensitive chalcogenide glass membranes for the simultaneous detection of the four ions Ag⁺, Cu2⁺, Cd2⁺, and Pb2⁺ in solution is realized. The results of the physical characterization by means of microscopy, profilometry, Rutherford backscattering spectroscopy (RBS), and scanning electron microscopy (SEM) as well as the electrochemical characterization by means of potentiometric measurements are presented. Additionally, the possibility to expand the sensor array by polymeric sensor membranes is discussed.}, language = {en} } @article{SpelthahnSchubertSchoening2012, author = {Spelthahn, Heiko and Schubert, J{\"u}rgen and Sch{\"o}ning, Michael Josef}, title = {D{\"u}nnschichtsensoren f{\"u}r die Schwermetallanalytik}, series = {GIT : Labor-Fachzeitschrift}, volume = {56}, journal = {GIT : Labor-Fachzeitschrift}, number = {4}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0016-3538}, pages = {285 -- 287}, year = {2012}, abstract = {Die Detektion von Schadstoffen repr{\"a}sentiert in der Umweltanalytik eine wichtige Aufgabenstellung. Gerade die Abwasser- bzw. Brauchwasseranalytik sowie die Prozesskontrolle haben einen hohen Stellenwert. Siliziumbasierte D{\"u}nnschichtsensoren bieten eine kosteng{\"u}nstige M{\"o}glichkeit, „online"-Messungen bzw. Vor-Ort-Messungen zeitnah durchzuf{\"u}hren. In dieser Arbeit wird ein potentiometrisches Sensorarray auf der Basis von Chalkogenidgl{\"a}sern zur Detektion von Schwermetallen in w{\"a}ssrigen Medien vorgestellt.}, language = {en} } @inproceedings{GerhardsSanderBelloum2012, author = {Gerhards, Michael and Sander, Volker and Belloum, Adam}, title = {About the flexible Migration of Workflow Tasks to Clouds : Combining on- and off-premise Executions of Applications}, series = {CLOUD COMPUTING 2012 : The Third International Conference on Cloud Computing, GRIDs, and Virtualization ; July 22-27, 2012 - Nice, France}, booktitle = {CLOUD COMPUTING 2012 : The Third International Conference on Cloud Computing, GRIDs, and Virtualization ; July 22-27, 2012 - Nice, France}, editor = {Zimmermann, Wolf and Lee, Yong Woo and Demchenko, Yuri}, publisher = {IARIA Journals}, isbn = {978-1-61208-216-5}, pages = {82 -- 87}, year = {2012}, abstract = {An increasing number of applications target their executions on specific hardware like general purpose Graphics Processing Units. Some Cloud Computing providers offer this specific hardware so that organizations can rent such resources. However, outsourcing the whole application to the Cloud causes avoidable costs if only some parts of the application benefit from the specific expensive hardware. A partial execution of applications in the Cloud is a tradeoff between costs and efficiency. This paper addresses the demand for a consistent framework that allows for a mixture of on- and off-premise calculations by migrating only specific parts to a Cloud. It uses the concept of workflows to present how individual workflow tasks can be migrated to the Cloud whereas the remaining tasks are executed on-premise.}, language = {en} } @article{KotliarLanzl2011, author = {Kotliar, Konstantin and Lanzl, Ines M.}, title = {Can vascular function be assessed by the interpretation of retinal vascular diameter changes?}, series = {Investigative Ophthalmology \& Visual Science, IOVS. 52 (2011), H. 1}, journal = {Investigative Ophthalmology \& Visual Science, IOVS. 52 (2011), H. 1}, publisher = {ARVO}, address = {Rockville, Md.}, isbn = {0146-0404}, pages = {635 -- 636}, year = {2011}, language = {en} } @article{KotliarMueckeVilseretal.2008, author = {Kotliar, Konstantin and M{\"u}cke, Bruno and Vilser, Walthard and Schilling, Rudolf}, title = {Effect of aging on retinal artery blood column diameter measured along the vessel axis / Kotliar, Konstantin E. ; M{\"u}cke, Bruno ; Vilser, Walthard ; Schilling, Rudolf ; Lanzl, Ines M.}, series = {Investigative Ophthalmology \& Visual Science, IOVS. 49 (2008), H. 5}, journal = {Investigative Ophthalmology \& Visual Science, IOVS. 49 (2008), H. 5}, publisher = {-}, isbn = {0146-0404}, pages = {2094 -- 2102}, year = {2008}, language = {en} } @article{KotliarLanzlHanssenetal.2012, author = {Kotliar, Konstantin and Lanzl, Ines M. and Hanssen, Henner and Eberhardt, Karla and Vilser, Walthard and Halle, Martin and Heemann, Uwe and Schmidt-Trucks{\"a}ss, Arno and Baumann, Marcus}, title = {Does increased blood pressure rather than aging influence retinal pulse wave velocity?}, series = {Investigative Ophthalmology \& Visual Science, IOVS}, volume = {53}, journal = {Investigative Ophthalmology \& Visual Science, IOVS}, number = {4}, publisher = {ARVO}, address = {Rockville, Md.}, issn = {0146-0404}, doi = {10.1167/iovs.11-8815}, pages = {2119 -- 2126}, year = {2012}, abstract = {Purpose: It was demonstrated previously that retinal pulse wave velocity (rPWV) as a measure of retinal arterial stiffness is increased in aged anamnestically healthy volunteers compared with young healthy subjects. Using novel methodology of rPWV assessment this finding was confirmed and investigated whether it might relate to the increased blood pressure usually accompanying the aging process, rather than to the aging itself. Methods: A total of 12 young 25.5-year-old (24.0-28.8) [median(1st quartile-3rd quartile)] and 12 senior 68.5-year-old (63.8-71.8) anamnestically healthy volunteers; and 12 senior 63.0-year-old (60.8-65.0) validated healthy volunteers and 12 young 33.0-year-old (29.5-35.0) hypertensive patients were examined. Time-dependent alterations of vessel diameter were assessed by the Dynamic Vessel Analyzer in a retinal artery of each subject. The data were filtered and processed using mathematical signal analysis and rPWVs were calculated. Results: rPWV amounted to 1200 (990-1470) RU (relative units)/s in the hypertensive group and to 1040 (700-2230) RU/s in anamnestically healthy seniors. These differed significantly from rPWVs in young healthy group (410 [280-500] RU/s) and in validated healthy seniors (400 [320-510] RU/s). rPWV associated with age and mean arterial pressure (MAP) in the pooled cohort excluded validated healthy seniors. In a regression model these associations remain when alternately adjusted for MAP and age. When including validated healthy seniors in the pooled cohort only association with MAP remains. Conclusions: Both aging (with not excluded cardiovascular risk factors) and mild hypertension are associated with elevated rPWV. rPWV increases to a similar extent both in young mildly hypertensive subjects and in aged anamnestically healthy persons. Healthy aging is not associated with increased rPWV.}, language = {en} } @article{KotliarNagelVilseretal.2010, author = {Kotliar, Konstantin and Nagel, Edgar and Vilser, Walthard and Seidova, Seid-Fatima and Lanzl, Ines}, title = {Microstructural alterations of retinal arterial blood column along the vessel axis in systemic hypertension}, series = {Investigative Ophthalmology \& Visual Science, IOVS}, volume = {51}, journal = {Investigative Ophthalmology \& Visual Science, IOVS}, number = {4}, publisher = {ARVO}, address = {Rockville, Md.}, issn = {0146-0404}, doi = {10.1167/iovs.09-3649}, pages = {2165 -- 2172}, year = {2010}, abstract = {Purpose: Image analysis by the retinal vessel analyzer (RVA) observes retinal vessels in their dynamic state online noninvasively along a chosen vessel segment. It has been found that high-frequency diameter changes in the retinal artery blood column along the vessel increase significantly in anamnestically healthy volunteers with increasing age and in patients with glaucoma during vascular dilation. This study was undertaken to investigate whether longitudinal sections of the retinal artery blood column are altered in systemic hypertension. Methods: Retinal arteries of 15 untreated patients with essential arterial hypertension (age, 50.9 ± 11.9 years) and of 15 age-matched anamnestically healthy volunteers were examined by RVA. After baseline assessment, a monochromatic luminance flicker (530-600 nm; 12.5 Hz; 20 s) was applied to evoke retinal vasodilation. Differences in amplitude and frequency of spatial artery blood column diameter change along segments (longitudinal arterial profiles) of 1 mm in length were measured and analyzed using Fourier transformation. Results: In the control group, average reduced power spectra (ARPS) of longitudinal arterial profiles did not differ when arteries changed from constriction to dilation. In the systemic hypertension group, ARPS during constriction, baseline, and restoration were identical and differed from ARPS during dilation (P < 0.05). Longitudinal arterial profiles in both groups showed significant dissimilitude at baseline and restoration (P < 0.05). Conclusions: The retinal artery blood column demonstrates microstructural alterations in systemic hypertension and is less irregular along the vessel axis during vessel dilation. These microstructural changes may be an indication of alterations in vessel wall rigidity, vascular endothelial function, and smooth muscle cells in this disease, leading to impaired perfusion and regulation.}, language = {en} } @article{LanzlSeidovaMaieretal.2011, author = {Lanzl, Ines M. and Seidova, Seid-Fatima and Maier, Mathias and Schmidt-Trucks{\"a}ss, Arno and Halle, Martin and Kotliar, Konstantin}, title = {Dynamic retinal vessel response to flicker in age-related macular degeneration patients before and after vascular endothelial growth factor inhibitor injection}, series = {Acta Ophthalmologica}, volume = {89}, journal = {Acta Ophthalmologica}, number = {5}, publisher = {Wiley}, address = {Weinheim}, isbn = {1755-3768}, pages = {472 -- 479}, year = {2011}, language = {en} } @article{KotliarMaierBaueretal.2008, author = {Kotliar, Konstantin and Maier, Mathias and Bauer, Svetlana and Feucht, Nikolaus and Lohmann, Chris and Lanzl, Ines}, title = {Intravitreal injection of triamcinolone acetonide and intraocular pressure: author's reply}, series = {Acta Ophthalmologica}, volume = {86}, journal = {Acta Ophthalmologica}, number = {6}, publisher = {-}, isbn = {1755-3768}, pages = {692 -- 693}, year = {2008}, language = {en} } @article{KotliarNagelVilseretal.2008, author = {Kotliar, Konstantin and Nagel, Edgar and Vilser, Walthard and Lanzl, Ines M.}, title = {Functional in vivo assessment of retinal artery microirregularities in glaucoma / Kotliar, Konstantin E. ; Nagel, Edgar ; Vilser, Walthard ; Lanzl, Ines M.}, series = {Acta Ophthalmologica. 86 (2008), H. 4}, journal = {Acta Ophthalmologica. 86 (2008), H. 4}, publisher = {-}, isbn = {1755-3768}, pages = {424 -- 433}, year = {2008}, language = {en} } @article{KotliarMaierBaueretal.2007, author = {Kotliar, Konstantin and Maier, Mathias and Bauer, Svetlana and Feucht, Nikolaus}, title = {Effect of intravitreal injections and volume changes on intraocular pressure: clinical results and biomechanical model / Kotliar, Konstantin ; Maier, Mathias ; Bauer, Svetlana ; Feucht, Nikolaus ; Lohmann, Chris ; Lanzl, Ines}, series = {Acta Ophthalmologica Scandinavica. 85 (2007), H. 7}, journal = {Acta Ophthalmologica Scandinavica. 85 (2007), H. 7}, publisher = {-}, isbn = {1755-3768}, pages = {777 -- 781}, year = {2007}, language = {en} } @article{BohrnStuetzFuchsetal.2012, author = {Bohrn, U. and St{\"u}tz, E. and Fuchs, K. and Fleischer, M. and Sch{\"o}ning, Michael Josef and Wagner, P.}, title = {Monitoring of irritant gas using a whole-cell-based sensor system}, series = {Sensors and Actuators B: Chemical}, volume = {175}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2012.05.088}, pages = {208 -- 217}, year = {2012}, abstract = {Cell-based sensors for the detection of gases have long been underrepresented, due to the cellular requirement of being cultured in a liquid environment. In this work we established a cell-based gas biosensor for the detection of toxic substances in air, by adapting a commercial sensor chip (Bionas®), previously used for the measurement of pollutants in liquids. Cells of the respiratory tract (A549, RPMI 2650, V79), which survive at a gas phase in a natural context, are used as biological receptors. The physiological cell parameters acidification, respiration and morphology are continuously monitored in parallel. Ammonia was used as a highly water-soluble model gas to test the feasibility of the sensor system. Infrared measurements confirmed the sufficiency of the medium draining method. This sensor system provides a basis for many sensor applications such as environmental monitoring, building technology and public security.}, language = {en} } @article{HillenAlperSelverFischeretal.2007, author = {Hillen, Walter and Alper Selver, M. and Fischer, Felix and Kuntalp, Mehmet}, title = {A software tool for interactive generation, representation, and systematical storage of transfer functions for 3D medical images / Alper Selver, M. ; Fischer, Felix ; Kuntalp, Mehmet ; Hillen, Walter}, series = {Computer Methods and Programs in Biomedicine. 86 (2007), H. 3}, journal = {Computer Methods and Programs in Biomedicine. 86 (2007), H. 3}, publisher = {-}, isbn = {0169-2607}, pages = {270 -- 280}, year = {2007}, language = {en} } @article{KotliarMogilevskiĭShiloetal.2008, author = {Kotliar, Konstantin and Mogilevskiĭ, A. Ia. and Shilo, A. V. and Panchekha, A. P.}, title = {[Chaotic non-linear dynamics of alpha-band of the EEg and organization of the cortical activity of P300 wave] / Mogilevskiĭ, A. Ia. ; Kotliar, K. E. ; Shilo, A. V. ; Panchekha, A. P.}, series = {Zhurnal vyssheĭ nervnoĭ deiatelnosti imeni I P Pavlova. 58 (2008), H. 5}, journal = {Zhurnal vyssheĭ nervnoĭ deiatelnosti imeni I P Pavlova. 58 (2008), H. 5}, publisher = {-}, isbn = {0044-4677}, pages = {562 -- 575}, year = {2008}, language = {en} } @article{KotliarSvetlovaMakarovetal.2003, author = {Kotliar, Konstantin and Svetlova, O. V. and Makarov, F. N. and Zaseeva, M. V.}, title = {Morfologicheskie i funktsional'nye osobennosti resnichnogo poiaska khrustalika kak kliuchevogo ispolnitel'nogo zvena v mekhanizme akkommodatsii glaza cheloveka = Morpho-functional characteristics of lens ciliary body as a key mechanism of accommodation in}, series = {Morfologiia (Saint Petersburg, Russia). 123 (2003), H. 3}, journal = {Morfologiia (Saint Petersburg, Russia). 123 (2003), H. 3}, publisher = {-}, isbn = {1026-3543}, pages = {7 -- 16}, year = {2003}, language = {en} } @article{KotliarVolkovKoshitsetal.1997, author = {Kotliar, Konstantin and Volkov, V. V. and Koshits, I. N. and Svetlova, O. V.}, title = {Biomekhanicheskie osobennosti vzaimodeĭstviia drenazhno i akkomodatsionnoĭ reguliatornykh sistem glaza v norme i pri kontuzionnom podvyvikhe khrustalika / Volkov, V. V. ; Kotliar, K. E. ; Koshits, I. n. ; Svetlova, O. V. ; Smol´nikov, B. A.}, series = {Vestnik oftalmologii. 113 (1997), H. 3}, journal = {Vestnik oftalmologii. 113 (1997), H. 3}, publisher = {-}, isbn = {0042-465X}, pages = {5 -- 7}, year = {1997}, language = {en} } @article{PresslerEsefeldScherretal.2010, author = {Pressler, Axel and Esefeld, Katrin and Scherr, Johannes and Ali, Mohammad and Hanssen, Henner and Kotliar, Konstantin and Lanzl, Ines and Halle, Martin and Kaemmerer, Harald and Schmidt-Trucks{\"a}ss, Arno and Hager, Alfred}, title = {Structural alterations of retinal arterioles in adults late after repair of aortic isthmic coarctation}, series = {The American Journal of Cardiology}, volume = {105}, journal = {The American Journal of Cardiology}, number = {5}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0002-9149}, doi = {10.1016/j.amjcard.2009.10.070}, pages = {740 -- 744}, year = {2010}, abstract = {Patients after coarctation repair still have an increased risk of cardiovascular or cerebrovascular events. This has been explained by the persisting hypertension and alterations in the peripheral vessels. However, involvement of the central vessels such as the retinal arteries is virtually unknown. A total of 34 patients after coarctation repair (22 men and 12 women; 23 to 58 years old, age range 0 to 32 years at surgical repair) and 34 nonhypertensive controls underwent structural and functional retinal vessel analysis. Using structural analysis, the vessel diameters were measured. Using functional analysis, the endothelium-dependent vessel dilation in response to flicker light stimulation was assessed. In the patients after coarctation repair, the retinal arteriolar diameter was significantly reduced compared to that of the controls (median 182 μm, first to third quartile 171 to 197; vs 197 μm, first to third quartile 193 to 206; p <0.001). These findings were independent of the peripheral blood pressure and age at intervention. No differences were found for venules. The functional analysis findings were not different between the patients and controls (maximum dilation 3.5\%, first to third quartile 2.1\% to 4.5\% vs 3.6\%, first to third quartile 2.2\% to 4.3\%; p = 0.81), indicating preserved autoregulative mechanisms. In conclusion, the retinal artery diameter is reduced in patients after coarctation repair, independent of their current blood pressure level and age at intervention. As a structural marker of chronic vessel damage associated with past, current, or future hypertension, retinal arteriolar narrowing has been linked to stroke incidence. These results indicate an involvement of cerebral microcirculation in aortic coarctation, despite timely repair, and might contribute to explain the increased rate of cerebrovascular events in such patients.}, language = {en} } @article{MikielewiczKotliarBarraqueretal.2011, author = {Mikielewicz, Marek and Kotliar, Konstantin and Barraquer, Rafael I. and Michael, Ralph}, title = {Air-pulse corneal applanation signal curve parameters for the characterisation of keratoconus}, series = {British Journal of Ophthalmology (eBJO)}, volume = {95}, journal = {British Journal of Ophthalmology (eBJO)}, number = {6}, publisher = {BMJ Publ. Group}, address = {London}, issn = {1468-2079}, pages = {793 -- 798}, year = {2011}, language = {en} } @article{KotliarBaumannVilseretal.2011, author = {Kotliar, Konstantin and Baumann, Marcus and Vilser, Walthard and Lanzl, Ines M.}, title = {Pulse wave velocity in retinal arteries of healthy volunteers}, series = {British Journal of Ophthalmology (eBJO)}, volume = {95}, journal = {British Journal of Ophthalmology (eBJO)}, number = {11}, publisher = {BMJ Publ. Group}, address = {London}, isbn = {1468-2079}, pages = {675 -- 679}, year = {2011}, language = {en} } @article{KotliarLanzlSchmidtTrucksaessetal.2011, author = {Kotliar, Konstantin and Lanzl, Ines M. and Schmidt-Trucks{\"a}ss, A. and Sitnikova, Diana and Ali, Mohammad and Blume, Katharina and Halle, Martin and Hansser, Henner}, title = {Dynamic retinal vessel response to flicker in obesity: A methodological approach}, series = {Microvascular Research}, volume = {81}, journal = {Microvascular Research}, number = {1}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0026-2862}, pages = {123 -- 128}, year = {2011}, language = {en} } @article{DashevskyLanzlKotliar2011, author = {Dashevsky, Alexey V. and Lanzl, Ines M. and Kotliar, Konstantin}, title = {Non-penetrating intracanalicular partial trabeculectomy via the ostia of Schlemm's canal}, series = {Graefe's Archive for Clinical and Experimental Ophthalmology}, volume = {249}, journal = {Graefe's Archive for Clinical and Experimental Ophthalmology}, number = {4}, publisher = {Springer}, address = {Berlin}, issn = {0721-832x}, pages = {565 -- 573}, year = {2011}, language = {en} } @article{BaumannSchwarzKotliaretal.2009, author = {Baumann, Marcus and Schwarz, Sonja and Kotliar, Konstantin and Eynatten, Maximilian von and Trucksaess, Arno and Burckhardt, Klaus and Lutz, Jens and Heemann, Uwe and Lanzl, Ines}, title = {Non-diabetic chronic kidney disease influences retinal microvasculature}, series = {Kidney and Blood Pressure Research}, volume = {32}, journal = {Kidney and Blood Pressure Research}, number = {6}, publisher = {-}, isbn = {1423-0143}, pages = {428 -- 433}, year = {2009}, language = {en} } @article{HanssenNickelDrexeletal.2011, author = {Hanssen, H. and Nickel, T. and Drexel, V. and Hertel, G. and Emslander, I. and Sisic, Z. and Lorang, D. and Schuster, T. and Kotliar, Konstantin and Pressler, A. and Schmidt-Trucks{\"a}ss, A. and Weis, M. and Halle, M.}, title = {Exercise-induced alterations of retinal vessel diameters and cardiovascular risk reduction in obesity}, series = {Atherosclerosis}, volume = {216}, journal = {Atherosclerosis}, number = {2}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {0021-9150}, pages = {433 -- 439}, year = {2011}, language = {en} } @article{KirchnerReisertPuetzetal.2012, author = {Kirchner, Patrick and Reisert, Steffen and P{\"u}tz, Patrick and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Characterisation of polymeric materials as passivation layer for calorimetric H2O2 gas sensors}, series = {Physica Status Solidi (a)}, volume = {209}, journal = {Physica Status Solidi (a)}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201100773}, pages = {859 -- 863}, year = {2012}, abstract = {Calorimetric gas sensors for monitoring the H₂O₂ concentration at elevated temperatures in industrial sterilisation processes have been presented in previous works. These sensors are built up in form of a differential set-up of a catalytically active and passive temperature-sensitive structure. Although, various types of catalytically active dispersions have been studied, the passivation layer has to be established and therefore, chemically as well as physically characterised. In the present work, fluorinated ethylene propylene (FEP), perfluoralkoxy (PFA) and epoxy-based SU-8 photoresist as temperature-stable polymeric materials have been investigated for sensor passivation in terms of their chemical inertness against H₂O₂, their hygroscopic properties as well as their morphology. The polymeric materials were deposited via spin-coating on the temperature-sensitive structure, wherein spin-coated FEP and PFA show slight agglomerates. However, they possess a low absorption of humidity due to their hydrophobic surface, whereas the SU-8 layer has a closed surface but shows a slightly higher absorption of water. All of them were inert against gaseous H₂O₂ during the characterisation in H₂O₂ atmosphere that demonstrates their suitability as passivation layer for calorimetric H₂O₂ gas sensors.}, language = {en} } @article{BurkhardtSchwarzPanetal.2009, author = {Burkhardt, Klaus and Schwarz, Sonja and Pan, Chengrui and Stelter, Felix and Kotliar, Konstantin and Eynatten, Maxilian von and Sollinger, Daniel and Lanzl, Ines and Heemann, Uwe and Baumann, Marcus}, title = {Myeloid-related protein 8/14 complex describes microcirculatory alterations in patients with type 2 diabetes and nephropathy}, series = {Cardiovascular Diabetology}, volume = {8}, journal = {Cardiovascular Diabetology}, number = {10}, publisher = {-}, isbn = {1475-2840}, pages = {1 -- 8}, year = {2009}, language = {en} } @article{GarhoferBekBoehmetal.2010, author = {Garhofer, Gerhard and Bek, Toke and Boehm, Andreas G. and Gherghel, Doina and Grundwald, Juan and Jeppesen, Peter and Kergoat, H{\´e}l{\`e}ne and Kotliar, Konstantin and Lanzl, Ines and Lovasik, John V. and Nagel, Edgar and Vilser, Walthard and Orgul, Selim and Schmetterer, Leopold}, title = {Use of the retinal vessel analyzer in ocular blood flow research}, series = {Acta Ophthalmol}, volume = {88}, journal = {Acta Ophthalmol}, number = {7}, publisher = {Wiley-Blackwell}, address = {Oxford}, issn = {1755-3768}, doi = {10.1111/j.1755-3768.2009.01587.x}, pages = {717 -- 722}, year = {2010}, abstract = {The present article describes a standard instrument for the continuous online determination of retinal vessel diameters, the commercially available retinal vessel analyzer. This report is intended to provide informed guidelines for measuring ocular blood flow with this system. The report describes the principles underlying the method and the instruments currently available, and discusses clinical protocol and the specific parameters measured by the system. Unresolved questions and the possible limitations of the technique are also discussed.}, language = {en} }