@article{BussmannEngelsFussetal.2000, author = {Bussmann, N. and Engels, R. and Fuss, L. and Kemmerling, G. and Reinartz, R. and Langen, K.-J. and Schelten, J. and Ziemons, Karl}, title = {Performance measurement of a new high resolution detector system for I-131 thyroid studies}, series = {2000 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, journal = {2000 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, issn = {1082-3654}, pages = {22/35 -- 22/37}, year = {2000}, abstract = {A 2-dimensional detector system for high resolution thyroid I-131 scintigraphy was developed. It has a sensitive area of 4 cm×4 cm and consists of a lead-collimator and an array of 10×10 EGO crystals combined with a position sensitive photomultiplier. The spatial resolution and the sensitivity of the detector has been measured and compared to two commercially available gamma-cameras. Furthermore first patient measurements have been carried out}, language = {de} } @article{StreunBrandenburgLarueetal.2000, author = {Streun, M. and Brandenburg, G. and Larue, H. and Zimmermann, E. and Ziemons, Karl and Halling, H.}, title = {Pulse recording by free-running sampling}, series = {2000 IEEE Nuclear Science Symposium Conference Record, Vol. 2}, journal = {2000 IEEE Nuclear Science Symposium Conference Record, Vol. 2}, issn = {1082-3654}, pages = {9/179 -- 9/181}, year = {2000}, abstract = {Pulses from a position-sensitive photomultiplier (PS-PMT) are recorded by free running ADCs at a sampling rate of 40 MHz. A four-channel acquisition-board has been developed which is equipped with four 12 bit-ADCs connected to one FPGA (field programmable gate array). The FPGA manages data acquisition and the transfer to the host computer. It can also work as a digital trigger, so a separate hardware-trigger can be omitted. The method of free running sampling provides a maximum of information, besides the pulse charge and amplitude also pulse shape and starting time are contained in the sampled data. These informations are crucial for many tasks such as distinguishing between different scintillator materials, determination of radiation type, pile-up recovery, coincidence detection or time-of-flight applications. The absence of an analog integrator allows coping with very high count rates. Since this method is going to be employed in positron emission tomography (PET), the position of an event is another important information. The simultaneous readout of four channels allows localization by means of center-of-gravity weighting. First results from a test setup with LSO-scintillators coupled to the PS-PMT are presented}, language = {en} } @article{WeckesserGriessmeierSchmidtetal.1998, author = {Weckesser, Martin and Grießmeier, Martin and Schmidt, Daniela and Sonnenberg, Frank and Ziemons, Karl and Kemna, Lars and Holschbach, Marcus and Langen, Karl-J. and M{\"u}ller-G{\"a}rtner, Hans-W.}, title = {Iodine-123 α-methyl tyrosine single-photon emission tomography of cerebral gliomas: standardised evaluation of tumour uptake and extent}, series = {European Journal of Nuclear Medicine}, volume = {25}, journal = {European Journal of Nuclear Medicine}, number = {2}, isbn = {1619-7089}, pages = {150 -- 156}, year = {1998}, abstract = {Single-photon emission tomography (SPET) with the amino acid analogue l-3-[123I]iodo-α-methyl tyrosine (IMT) is helpful in the diagnosis and monitoring of cerebral gliomas. Radiolabelled amino acids seem to reflect tumour infiltration more specifically than conventional methods like magnetic resonance imaging and computed tomography. Automatic tumour delineation based on maximal tumour uptake may cause an overestimation of mean tumour uptake and an underestimation of tumour extension in tumours with circumscribed peaks. The aim of this study was to develop a program for tumour delineation and calculation of mean tumour uptake which takes into account the mean background activity and is thus optimised to the problem of tumour definition in IMT SPET. Using the frequency distribution of pixel intensities of the tomograms a program was developed which automatically detects a reference brain region and draws an isocontour region around the tumour taking into account mean brain radioactivity. Tumour area and tumour/brain ratios were calculated. A three-compartment phantom was simulated to test the program. The program was applied to IMT SPET studies of 20 patients with cerebral gliomas and was compared to the results of manual analysis by three different investigators. Activity ratios and chamber extension of the phantom were correctly calculated by the automatic analysis. A method based on image maxima alone failed to determine chamber extension correctly. Manual region of interest analysis in patient studies resulted in a mean inter-observer standard deviation of 8.7\%±6.1\% (range 2.7\%-25.0\%). The mean value of the results of the manual analysis showed a significant correlation to the results of the automatic analysis (r = 0.91, P<0.0001 for the uptake ratio; r = 0.87, P<0.0001 for the tumour area). We conclude that the algorithm proposed simplifies the calculation of uptake ratios and may be used for observer-independent evaluation of IMT SPET studies. Three-dimensional tumour recognition and transfer to co-registered morphological images based on this program may be useful for the planning of surgical and radiation treatment.}, language = {en} } @article{ZiemonsKleinesErkenetal.1997, author = {Ziemons, Karl and Kleines, H. and Erken, I. and Knoben, J. and Zwoll, K.}, title = {IME-DV Projekt: M-FIRBe, Multi-Modality Functional Imaging for Brain Research}, series = {Bildverarbeitung f{\"u}r die Medizin : Algorithmen - Systeme - Anwendungen}, journal = {Bildverarbeitung f{\"u}r die Medizin : Algorithmen - Systeme - Anwendungen}, editor = {Lehmann, Thomas}, publisher = {Verl. der. Augustinus-Buchh.}, address = {Aachen}, isbn = {3-86073-519-5}, pages = {363 -- 366}, year = {1997}, language = {de} } @article{KleinesErkiZiemonsetal.1997, author = {Kleines, H. and Erki, I. and Ziemons, Karl and Zwoll, K.}, title = {ATM- und Multimedia Pilotsystem im Rahmen des Projektes M-FIBRe Aufbau und Erfahrungen}, series = {Bildverarbeitung f{\"u}r die Medizin : Algorithmen - Systeme - Anwendungen}, journal = {Bildverarbeitung f{\"u}r die Medizin : Algorithmen - Systeme - Anwendungen}, editor = {Lehmann, Thomas}, publisher = {Verl. der. Augustinus-Buchh.}, address = {Aachen}, isbn = {3-86073-519-5}, pages = {241 -- 248}, year = {1997}, language = {de} } @article{ErkiKleinesZiemonsetal.1997, author = {Erki, I. and Kleines, H. and Ziemons, Karl and Zwoll, K.}, title = {Interaktives System zur Darstellung funktionaler Bilddaten}, series = {Bildverarbeitung f{\"u}r die Medizin : Algorithmen - Systeme - Anwendungen}, journal = {Bildverarbeitung f{\"u}r die Medizin : Algorithmen - Systeme - Anwendungen}, editor = {Lehmann, Thomas}, publisher = {Verl. der. Augustinus-Buchh.}, address = {Aachen}, isbn = {3-86073-519-5}, pages = {249 -- 254}, year = {1997}, language = {de} } @article{LangenZiemonsKiwitetal.1997, author = {Langen, Karl J. and Ziemons, Karl and Kiwit, J{\"u}rgen C. W. and Herzog, Hans and Kuwert, Torsten and Bock, Wolfgang and St{\"o}cklin, Gerhard and Feinendegen, Ludwig E. and M{\"u}ller-G{\"a}rtner, Hans-W.}, title = {3-[123I]iodo-α-methyltyrosine and [methyl-11C]-L-methionine uptake in cerebral gliomas: a compara-tive study using SPECT and PET}, series = {Journal of Nuclear Medicine}, volume = {38}, journal = {Journal of Nuclear Medicine}, number = {4}, isbn = {0161-5505}, pages = {517 -- 522}, year = {1997}, language = {en} } @article{WeckesserHufnagelZiemonsetal.1997, author = {Weckesser, Matthias and Hufnagel, Andreas and Ziemons, Karl and Grießmeier, Martin and Sonnenberg, Frank and Hackl{\"a}nder, Thomas and Langen, Karl-J. and Holschbach, Markus and Elger, Christian E. and M{\"u}ller-G{\"a}rtner, Hans-W.}, title = {Effect of partial volume correction on muscarinic cholinergic receptor imaging with single-photon emission tomography in patients with temporal lobe epilepsy}, series = {European Journal of Nuclear Medicine}, volume = {24}, journal = {European Journal of Nuclear Medicine}, number = {9}, isbn = {1619-7089}, pages = {1156 -- 1161}, year = {1997}, abstract = {Animal experiments and preliminary results in humans have indicated alterations of hippocampal muscarinic acetylcholine receptors (mAChR) in temporal lobe epilepsy. Patients with temporal lobe epilepsy often present with a reduction in hippocampal volume. The aim of this study was to investigate the influence of hippocampal atrophy on the quantification of mAChR with single photon emission tomography (SPET) in patients with temporal lobe epilepsy. Cerebral uptake of the muscarinic cholinergic antagonist [123I]4-iododexetimide (IDex) was investigated by SPET in patients suffering from temporal lobe epilepsy of unilateral (n=6) or predominantly unilateral (n=1) onset. Regions of interest were drawn on co-registered magnetic resonance images. Hippocampal volume was determined in these regions and was used to correct the SPET results for partial volume effects. A ratio of hippocampal IDex binding on the affected side to that on the unaffected side was used to detect changes in muscarinic cholinergic receptor density. Before partial volume correction a decrease in hippocampal IDex binding on the focus side was found in each patient. After partial volume no convincing differences remained. Our results indicate that the reduction in hippocampal IDex binding in patients with epilepsy is due to a decrease in hippocampal volume rather than to a decrease in receptor concentration.}, language = {en} } @article{SchmidtLangenHerzogetal.1997, author = {Schmidt, Daniela and Langen, Karl-J. and Herzog, Hans and Wirths, Jochen and Holschbach, Markus and Kiwit, J{\"u}rgen C. W. and Ziemons, Karl and Coenen, Heinz-H. and M{\"u}ller-G{\"a}rtner, Hans-W.}, title = {Whole-body kinetics and dosimetry of L-3[123I]-iodo-α-methyltyrosine}, series = {European Journal of Nuclear Medicine}, volume = {24}, journal = {European Journal of Nuclear Medicine}, number = {9}, isbn = {1619-7089}, pages = {1162 -- 1166}, year = {1997}, language = {en} } @article{GriessmeierSonnenbergWeckesseretal.1996, author = {Grießmeier, M. and Sonnenberg, F. and Weckesser, M. and Ziemons, Karl and Langen, K.-J. and M{\"u}ller-G{\"a}rtner, H. W.}, title = {Improvement of SPECT quantification in small brain structures by using experiment based recovery-coefficient corrections}, series = {European Journal of Nuclear Medicine}, volume = {23}, journal = {European Journal of Nuclear Medicine}, number = {9}, issn = {1619-7089}, pages = {1238 -- 1238}, year = {1996}, language = {en} } @article{BoeckerKuwertLangenetal.1994, author = {Boecker, Henning and Kuwert, Torsten and Langen, Karl-J. and Lange, Herwig W. and Czech, Norbert and Ziemons, Karl and Herzog, Hans and Shikare, Shekar and Weindl, Anton and Feinendegen, Ludwig E.}, title = {SPECT with HMPAO compared to PET with FDG in Huntington disease}, series = {Journal of Computer Assisted Tomography}, volume = {18}, journal = {Journal of Computer Assisted Tomography}, number = {4}, isbn = {1532-3145}, pages = {542 -- 548}, year = {1994}, language = {en} } @article{Ziemons1993, author = {Ziemons, Karl}, title = {A measurement of the ratio of the nucleon structure function in copper and deuterium}, series = {Zeitschrift f{\"u}r Physik C Particles and Fields}, volume = {57}, journal = {Zeitschrift f{\"u}r Physik C Particles and Fields}, number = {2}, isbn = {1431-5858}, pages = {211 -- 218}, year = {1993}, abstract = {Results are presented on the ratios of the nucleon structure function in copper to deuterium from two separate experiments. The data confirm that the nucleon structure function,F 2, is different for bound nucleons than for the quasi-free ones in the deuteron. The redistribution in the fraction of the nucleon's momentum carried by quarks is investigated and it is found that the data are compatible with no integral loss of quark momenta due to nuclear effects.}, language = {en} } @article{Ziemons1992, author = {Ziemons, Karl}, title = {Muoproduction of J/ψ and the gluon distribution of the nucleon}, series = {Zeitschrift f{\"u}r Physik C Particles and Fields}, volume = {56}, journal = {Zeitschrift f{\"u}r Physik C Particles and Fields}, number = {1}, isbn = {1431-5858}, pages = {21 -- 28}, year = {1992}, abstract = {Measurements are presented of the inclusive distributions of the J/Ψ meson produced by muons of energy 200 GeV from an ammonia target. The gluon distribution of the nucleon has been derived from the data in the range 0.04