@article{SchoeningKirchnerNgetal.2010, author = {Sch{\"o}ning, Michael Josef and Kirchner, Patrick and Ng, Yue Ann and Spelthahn, Heiko and Schneider, Andreas and Henkel, Hartmut and Friedrich, Peter and Kolstad, Jens and Berger, J{\"o}rg and Keusgen, Michael}, title = {Gas sensor investigation based on a catalytically activated thin-film thermopile for H2O2 detection}, series = {Physica Status Solidi (A)}, volume = {207}, journal = {Physica Status Solidi (A)}, number = {4}, publisher = {Wiley-VCH}, address = {Berlin}, issn = {1862-6300}, doi = {10.1002/pssa.200983309}, pages = {787 -- 792}, year = {2010}, abstract = {In aseptic filling systems, hydrogen peroxide vapour is commonly used for the reduction of microbial contaminations in carton packages. In this process, the germicidal efficiency of the vapour depends especially on the H₂O₂ concentration. To monitor the H₂O₂ concentration, a calorimetric H₂O₂ gas sensor based on a catalytically activated thin-film thermopile is investigated. Two different sensor layouts, namely a circular and a linear form, as well as two various material pairs such as tungsten/nickel and gold/nickel, have been examined for the realization of a thin-film thermopile. Additionally, manganese oxide and palladium particles have been compared as responsive catalysts towards H₂O₂. The thin-film sensors have been investigated at various H₂O₂ concentrations, gas temperatures and flow rates.}, language = {en} } @article{TurekHeidenGuoetal.2010, author = {Turek, Monik and Heiden, Wolfgang and Guo, Sharon and Riesen, Alfred and Schubert, J{\"u}rgen and Zander, Willi and Kr{\"u}ger, Peter and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Simultaneous detection of cyanide and heavy metals for environmental analysis by means of µISEs}, series = {Physica Status Solidi (A)}, volume = {207}, journal = {Physica Status Solidi (A)}, number = {4}, publisher = {Wiley-VCH}, address = {Berlin}, issn = {1862-6300}, doi = {10.1002/pssa.200983303}, pages = {817 -- 823}, year = {2010}, abstract = {In environmental analysis, cyanide and heavy metals play an important role, because these substances are highly toxic for biological systems. They can lead to chronic and acute diseases. Due to the chemical properties of cyanide it is frequently used for industrial processes such as extraction of silver and gold. Heavy metals can be found as trace elements in nature and are often applied in industries e.g., galvanization processes. Up to now, cyanide and heavy metals can be detected by several sensors separately and their detection is often limited to laboratory investigations. In this publication, with regard to an in situ analysis, a new miniaturized silicon-based sensor system for the simultaneous detection of cyanide and heavy metals in aqueous solutions is presented that is based on chalcogenide glass-based micro ion-selective electrodes (µISEs). The µISEs are incorporated into a specially designed measuring system for the simultaneous detection of heavy metals and cyanide in solutions and validated by simultaneous measurements of Cu2+- and CN--ions, Cd2+- and CN-- ions and Pb2+- and CN--ions. The particular sensor system has shown good sensor properties in the µ-molar ion-concentration range. For simultaneous measurements in complex heavy metal and cyanide solutions an intelligent software using fuzzy logic is discussed.}, language = {en} } @article{JansenBehbahaniLaumenetal.2010, author = {Jansen, S. V. and Behbahani, Mehdi and Laumen, M. and Kaufmann, T. and Hormes, M. and Behr, Marek and Schmitz-Rode, T. and Steinseifer, U.}, title = {Investigation of Steady Flow Through a Realistic Model of the Thoracic Human Aorta Using 3D Stereo PIV and CFD-Simulation}, series = {ASAIO Journal}, volume = {56}, journal = {ASAIO Journal}, number = {2}, publisher = {Lippincott Williams \& Wilkins}, address = {Philadelphia}, doi = {10.1097/01.mat.0000369377.65122.a3}, pages = {98}, year = {2010}, language = {en} } @article{BehbahaniProbstMaietal.2010, author = {Behbahani, Mehdi and Probst, M. and Mai, A. and Tran, L. and Vonderstein, K. and Keschenau, P. and Linde, T. and Steinseifer, U. and Behr, Marek and Mottaghy, K.}, title = {The influence of high shear on thrombosis and hemolysis in artificial organs}, series = {The International Journal of Artificial Organs}, volume = {33}, journal = {The International Journal of Artificial Organs}, number = {7}, publisher = {Sage}, address = {Thousand Oaks}, issn = {0391-3988}, pages = {426 -- 426}, year = {2010}, language = {en} } @article{SchoeningBeckersSchaubetal.1996, author = {Sch{\"o}ning, Michael Josef and Beckers, Leah and Schaub, A. and Zander, W. and Schubert, J. and Mesters, S. and Kordos, P. and L{\"u}th, H.}, title = {A novel silicon-based pH sensor prepared by pulsed laser deposition technique}, series = {Proceedings of Eurosensors X, the 10th European Conference on Solid-State Transducers, September 8-11, 1996, Leuven, Belgium / [KU Leuven]. Puers, Robert. Vol. 3.}, journal = {Proceedings of Eurosensors X, the 10th European Conference on Solid-State Transducers, September 8-11, 1996, Leuven, Belgium / [KU Leuven]. Puers, Robert. Vol. 3.}, publisher = {Catholic University Leuven}, address = {Heverlee, Belgium}, isbn = {90-803282-1-9}, pages = {781 -- 784}, year = {1996}, language = {en} } @article{SiqueiraBaeckerPoghossianetal.2010, author = {Siqueira, Jos{\´e} R. Jr. and B{\"a}cker, Matthias and Poghossian, Arshak and Zucolotto, Valtencir and Oliveira, Osvaldo N. Jr. and Sch{\"o}ning, Michael Josef}, title = {Associating biosensing properties with the morphological structure of multilayers containing carbon nanotubes on field-effect devices}, series = {Physica Status Solidi (A)}, volume = {207}, journal = {Physica Status Solidi (A)}, number = {4}, publisher = {Wiley-VCH}, address = {Berlin}, issn = {1862-6300}, doi = {10.1002/pssa.200983301}, pages = {781 -- 786}, year = {2010}, abstract = {The control of molecular architecture provided by the layer-by-layer (LbL) technique has led to enhanced biosensors, in which advantageous features of distinct materials can be combined. Full optimization of biosensing performance, however, is only reached if the film morphology is suitable for the principle of detection of a specific biosensor. In this paper, we report a detailed morphology analysis of LbL films made with alternating layers of single-walled carbon nanotubes (SWNTs) and polyamidoamine (PAMAM) dendrimers, which were then covered with a layer of penicillinase (PEN). An optimized performance to detect penicillin G was obtained with 6-bilayer SWNT/PAMAM LbL films deposited on p-Si-SiO2-Ta2O5 chips, used in biosensors based on a capacitive electrolyte-insulator-semiconductor (EIS) and a light-addressable potentiometric sensor (LAPS) structure, respectively. Field-emission scanning electron microscopy (FESEM) and atomic force microscopy (AFM) images indicated that the LbL films were porous, with a large surface area due to interconnection of SWNT into PAMAM layers. This morphology was instrumental for the adsorption of a larger quantity of PEN, with the resulting LbL film being highly stable. The experiments to detect penicillin were performed with constant-capacitance (ConCap) and constant-current (CC) measurements for EIS and LAPS sensors, respectively, which revealed an enhanced detection signal and sensitivity of ca. 100 mV/decade for the field-effect sensors modified with the PAMAM/SWNT LbL film. It is concluded that controlling film morphology is essential for an enhanced performance of biosensors, not only in terms of sensitivity but also stability and response time.}, language = {en} } @article{BehbahaniTranWalugaetal.2009, author = {Behbahani, Mehdi and Tran, L. and Waluga, C. and Behr, Marek and Oedekoven, B. and Mottaghy, K.}, title = {Model-based Numerical Analysis of Platelet Adhesion, Thrombus Growth and Aggregation for Assist Devices}, series = {The International Journal of Artificial Organs. 32 (2009), H. 7}, journal = {The International Journal of Artificial Organs. 32 (2009), H. 7}, isbn = {0391-3988}, pages = {398 -- 398}, year = {2009}, language = {en} } @article{SchoeningSchaubZundeletal.1995, author = {Sch{\"o}ning, Michael Josef and Schaub, A. and Zundel, A. and Beckers, Leah and Schubert, J. and Zander, W. and Kordos, P. and L{\"u}th, H.}, title = {Pulsed laser deposition as a novel thin film preparation method for silicon-based field effect sensors}, series = {Proceedings of the 25th European Solid State Device Research Conference : the Netherlands Congress Centre, The Hague, the Netherlands, 25th - 27th September 1995 / ESSDERC '95. Ed. by H. C. de Graaff}, journal = {Proceedings of the 25th European Solid State Device Research Conference : the Netherlands Congress Centre, The Hague, the Netherlands, 25th - 27th September 1995 / ESSDERC '95. Ed. by H. C. de Graaff}, publisher = {Ed. Fronti{\`e}res}, address = {Gif-sur-Yvette}, isbn = {2-86332-182-X}, pages = {601 -- 604}, year = {1995}, language = {en} } @article{BehbahaniBehrAroraetal.2006, author = {Behbahani, Mehdi and Behr, Marek and Arora, D. and Coronado, O. and Pasquali, M.}, title = {CFD Analysis of MicroMed Debakey Pump and Hemolysis Prediction / Behbahani, M. ; Behr, M. ; Arora, D. ; Coronado, O. ; Pasquali, M.}, series = {Artificial Organs. 30 (2006), H. 11}, journal = {Artificial Organs. 30 (2006), H. 11}, isbn = {1525-1594}, pages = {A45 -- A46}, year = {2006}, language = {en} } @article{BehbahaniBehrHormesetal.2009, author = {Behbahani, Mehdi and Behr, Marek and Hormes, M. and Steinseifer, U. and Arora, D. and Coronado, O. and Pasquali, M.}, title = {A Review of Computational Fluid Dynamics Analysis of Blood Pumps}, series = {European Journal of Applied Mathematics. 20 (2009), H. 4}, journal = {European Journal of Applied Mathematics. 20 (2009), H. 4}, publisher = {Cambridge Univ. Press}, address = {Cambridge}, pages = {363 -- 397}, year = {2009}, language = {en} } @article{BehbahaniTranJockenhoeveletal.2011, author = {Behbahani, Mehdi and Tran, L. and Jockenh{\"o}vel, S. and Behr, Marek and Mottaghy, K.}, title = {Numerical prediction of thrombocyte reactions for application to a vascular flow model}, series = {British Journal of Surgery}, volume = {98}, journal = {British Journal of Surgery}, number = {S5}, publisher = {Oxford University Press}, address = {Oxford}, isbn = {1365-2168}, pages = {S17}, year = {2011}, language = {en} } @inproceedings{BaeckerKochGeigeretal.2016, author = {B{\"a}cker, Matthias and Koch, Claudia and Geiger, Fania and Eber, Fabian and Gliemann, Hartmut and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {A New Class of Biosensors Based on Tobacco Mosaic Virus and Coat Proteins as Enzyme Nanocarrier}, series = {Procedia Engineering}, volume = {Vol. 168}, booktitle = {Procedia Engineering}, issn = {1877-7058}, doi = {10.1016/j.proeng.2016.11.228}, pages = {618 -- 621}, year = {2016}, language = {en} } @article{UllrichGrottkeRossaintetal.2010, author = {Ullrich, Sebastian and Grottke, Oliver and Rossaint, Rolf and Staat, Manfred and Deserno, Thomas M. and Kuhlen, Torsten}, title = {Virtual Needle Simulation with Haptics for Regional Anaesthesia}, pages = {3 Seiten}, year = {2010}, language = {en} } @article{BehbahaniWalugaArltetal.2008, author = {Behbahani, Mehdi and Waluga, C. and Arlt, S. and Behr, Marek and Mottaghy, K.}, title = {Computational Analysis of Platelet Aggregation in a Taylor-Couette System}, series = {The International Journal of Artificial Organs. 31 (2008), H. 7}, journal = {The International Journal of Artificial Organs. 31 (2008), H. 7}, isbn = {0391-3988}, pages = {643}, year = {2008}, language = {en} } @article{ProbstBehbahaniBorrmannetal.2010, author = {Probst, M. and Behbahani, Mehdi and Borrmann, E. and Elgeti, S. and Nicolai, M. and Behr, Marek}, title = {Hemodynamic Modeling for Numerical Analysis and Design of Medical Devices}, year = {2010}, language = {en} } @article{BehbahaniMaiBergmannetal.2010, author = {Behbahani, Mehdi and Mai, A. and Bergmann, B. and Waluga, C. and Behr, Marek and Tran, L. and Vonderstein, K. and Mottaghy, K.}, title = {Modeling and Numerical Simulation of Blood Damage}, year = {2010}, language = {en} } @article{BehbahaniWalugaStocketal.2009, author = {Behbahani, Mehdi and Waluga, C. and Stock, S. and Mai, A. and Bergmann, B. and Behr, Marek and Tran, L. and Vonderstein, K. and Scheidt, H. and Oedekoven, B. and Mottaghy, K.}, title = {Modelling and Numerical Analysis of Platelet Reactions and Surface Thrombus Growth}, year = {2009}, language = {en} } @article{KowalskiLinderZierkeetal.2016, author = {Kowalski, Julia and Linder, Peter and Zierke, Simon and von Wulfen, Benedikt and Clemens, Joachim and Konstantinidis, Konstantinos and Ameres, Gerald and Hoffmann, Ruth and Mikucki, Jill A. and Tulaczyk, Slawek M. and Funke, Oliver and Blandfort, Daniel and Espe, Clemens and Feldmann, Marco and Francke, Gero and Hiecker, S. and Plescher, Engelbert and Sch{\"o}ngarth, Sarah and Dachwald, Bernd and Digel, Ilya and Artmann, Gerhard and Eliseev, Dmitry and Heinen, Dirk and Scholz, Franziska and Wiebusch, Christopher H. and Macht, Sabine and Bestmann, Ulf and Reineking, Thomas and Zetzsche, Christoph and Schill, Kerstin and F{\"o}rstner, Roger and Niedermeier, Herbert and Szumski, Arkadiusz and Eissfeller, Bernd and Naumann, Uwe and Helbing, Klaus}, title = {Navigation technology for exploration of glacier ice with maneuverable melting probes}, series = {Cold Regions Science and Technology}, journal = {Cold Regions Science and Technology}, number = {123}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0165-232X}, doi = {10.1016/j.coldregions.2015.11.006}, pages = {53 -- 70}, year = {2016}, abstract = {The Saturnian moon Enceladus with its extensive water bodies underneath a thick ice sheet cover is a potential candidate for extraterrestrial life. Direct exploration of such extraterrestrial aquatic ecosystems requires advanced access and sampling technologies with a high level of autonomy. A new technological approach has been developed as part of the collaborative research project Enceladus Explorer (EnEx). The concept is based upon a minimally invasive melting probe called the IceMole. The force-regulated, heater-controlled IceMole is able to travel along a curved trajectory as well as upwards. Hence, it allows maneuvers which may be necessary for obstacle avoidance or target selection. Maneuverability, however, necessitates a sophisticated on-board navigation system capable of autonomous operations. The development of such a navigational system has been the focal part of the EnEx project. The original IceMole has been further developed to include relative positioning based on in-ice attitude determination, acoustic positioning, ultrasonic obstacle and target detection integrated through a high-level sensor fusion. This paper describes the EnEx technology and discusses implications for an actual extraterrestrial mission concept.}, language = {en} } @article{PoghossianBerndsenSchoening2002, author = {Poghossian, Arshak and Berndsen, Lars and Sch{\"o}ning, Michael Josef}, title = {Chemical sensor as a physical sensor: ISFET-based flowvelocity, flow-direction and diffusion-coefficient sensor}, series = {Book of abstracts / ed. by J. Saneistr.}, journal = {Book of abstracts / ed. by J. Saneistr.}, publisher = {Czech Technical University, Faculty of Electrical Engineering, Department of Measurement}, address = {Prague}, isbn = {80-01-02576-4}, pages = {649 -- 652}, year = {2002}, language = {en} } @article{MuribYeapMartensetal.2015, author = {Murib, Mohammed Sharif and Yeap, Weng Siang and Martens, Daan and Liu, Xianjie and Bienstman, Peter and Fahlman, M. and Sch{\"o}ning, Michael Josef and Michiels, Luc and Haenen, Ken and Serpeng{\"u}zel, Ali and Wagner, Patrick}, title = {Photonic studies on polymer-coated sapphire-spheres : a model system for biological ligands}, series = {Sensors and actuators A: Physical}, volume = {222}, journal = {Sensors and actuators A: Physical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3069 (E-Journal); 0924-4247 (Print)}, doi = {10.1016/j.sna.2014.11.024}, pages = {212 -- 219}, year = {2015}, abstract = {In this study we show an optical biosensor concept, based on elastic light scattering from sapphire microspheres. Transmitted and elastic scattering intensity of the microspheres (radius 500 μm, refractive index 1.77) on an optical fiber half coupler is analyzed at 1510 nm. The 0.43 nm angular mode spacing of the resonances is comparable to the angular mode spacing value estimated using the optical size of the microsphere. The spectral linewidths of the resonances are in the order of 0.01 nm, which corresponds to quality factors of approximately 105. A polydopamine layer is used as a functionalizing agent on sapphire microspherical resonators in view of biosensor implementation. The varying layer thickness on the microsphere is determined as a function of the resonance wavelength shift. It is shown that polymer functionalization has a minor effect on the quality factor. This is a promising step toward the development of an optical biosensor.}, language = {en} } @article{MansurovDigelBiisenbaevetal.2012, author = {Mansurov, Zulkhair A. and Digel, Ilya and Biisenbaev, M. and Savistkaya, I. and Kistaubaeva, Aida and Akimbekov, Nuraly S. and Zhubanova, Azhar Achmet}, title = {Bio-composite material on the basis of carbonized rice husk in biomedicine and environmental applications}, series = {Eurasian Chemico-Technological Journal}, volume = {14}, journal = {Eurasian Chemico-Technological Journal}, number = {2}, publisher = {Institute of Combustion Problems}, address = {Almaty}, issn = {2522-4867}, doi = {10.18321/ectj105}, pages = {115 -- 131}, year = {2012}, language = {en} } @article{PoghossianBerndsenSchultzeetal.2001, author = {Poghossian, Arshak and Berndsen, Lars and Schultze, J. W. and L{\"u}th, H. and Sch{\"o}ning, Michael Josef}, title = {„High order" hybrid sensor module based on an identical transducer principle}, series = {Chemical and biological sensors and analytical methods : proceedings of the international symposium / Sensor, Physical Electrochemistry, and Organic and Biological Electrochemistry Divisions. Ed.: M. Butler}, journal = {Chemical and biological sensors and analytical methods : proceedings of the international symposium / Sensor, Physical Electrochemistry, and Organic and Biological Electrochemistry Divisions. Ed.: M. Butler}, publisher = {Electrochemical Society}, address = {Pennington, NJ}, isbn = {1-56677-351-2}, pages = {143 -- 152}, year = {2001}, language = {en} } @article{ChristiaensAbouzarPoghossianetal.2007, author = {Christiaens, Pieter and Abouzar, Maryam H. and Poghossian, Arshak and Wagner, Torsten and Bijnens, Nathalie and Williams, Oliver A. and Daenen, Michael and Haenen, Ken and Douth{\´e}ret, Olivier and D'Haen, Jan and Mekhalif, Z. and Sch{\"o}ning, Michael Josef and Wagner, Patrick}, title = {pH sensitivity of nanocrystalline diamond films}, series = {Physica status solidi (A). 204 (2007), H. 9}, journal = {Physica status solidi (A). 204 (2007), H. 9}, isbn = {0031-8965}, pages = {2925 -- 2930}, year = {2007}, language = {en} } @article{ChristiaensAbouzarPoghossianetal.2007, author = {Christiaens, Pieter and Abouzar, Maryam H. and Poghossian, Arshak and Wagner, Torsten and Bijnens, Nathalie and Williams, Oliver A. and Daenen, Michael and Haenen, Ken and Sch{\"o}ning, Michael Josef and Wagner, Patrick}, title = {Nanocrystalline diamond-based field-effect capacitive pH sensor}, series = {Transducers '07 Eurosensors XXI : digest of technical papers ; the14th International Conference on Solid-State Sensors, Actuators and Microsystems, June 10-14, 2007, Lyon, France / Gilles Delapierre (Ed.)}, journal = {Transducers '07 Eurosensors XXI : digest of technical papers ; the14th International Conference on Solid-State Sensors, Actuators and Microsystems, June 10-14, 2007, Lyon, France / Gilles Delapierre (Ed.)}, publisher = {IEEE}, address = {Piscataway}, isbn = {1-4244-0841-5}, pages = {1891 -- 1894}, year = {2007}, language = {en} } @article{PoghossianAbouzarRazavietal.2009, author = {Poghossian, Arshak and Abouzar, Maryam H. and Razavi, Arash and B{\"a}cker, Matthias and Bijnens, Nathalie and Williams, Oliver A. and Haenen, Ken and Moritz, Werner and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Nanocrystalline-diamond thin films with high pH and penicillin sensitivity prepared on a capacitive Si-SiO2 structure}, series = {Electrochimica Acta. 54 (2009), H. 25}, journal = {Electrochimica Acta. 54 (2009), H. 25}, isbn = {0013-4686}, pages = {5981 -- 5985}, year = {2009}, language = {en} } @article{AbouzarPoghossianRazavietal.2009, author = {Abouzar, Maryam H. and Poghossian, Arshak and Razavi, Arash and Williams, Oliver A. and Bijnens, Nathalie and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Characterisation of capacitive field-effect sensors with a nanocrystalline-diamond film as transducer material for multi-parameter sensing}, series = {Biosensors and Bioelectronics. 24 (2009), H. 5}, journal = {Biosensors and Bioelectronics. 24 (2009), H. 5}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {0956-5663}, pages = {1298 -- 1304}, year = {2009}, language = {en} } @article{SchoeningKrauseBlocketal.2003, author = {Sch{\"o}ning, Michael Josef and Krause, Robin and Block, Kirstin and Musahmeh, Mustafa and Mulchandani, Ashok and Wang, Joseph}, title = {A dual amperometric/potentiometric FIA-based biosensor for the distinctive detection of organophosphorus pesticides}, series = {Sensors and Actuators B. 95 (2003), H. 1-3}, journal = {Sensors and Actuators B. 95 (2003), H. 1-3}, isbn = {0925-4005}, pages = {291 -- 296}, year = {2003}, language = {en} } @article{WangKrauseBlocketal.2003, author = {Wang, J. and Krause, R. and Block, Kirstin and Musameh, M. and Mulchandani, A. and Sch{\"o}ning, Michael Josef}, title = {Flow injection amperometric detection of OP nerve agents based on organophosphorus-hydrolase biosensor detector}, series = {Biosensors \& Bioelectronics. 18 (2003), H. 2-3}, journal = {Biosensors \& Bioelectronics. 18 (2003), H. 2-3}, isbn = {0956-5663}, pages = {255 -- 260}, year = {2003}, language = {en} } @article{SchoeningKloockKnobbeetal.2004, author = {Sch{\"o}ning, Michael Josef and Kloock, Joachim P. and Knobbe, D.-T. and Krause, R. and Block, Kirstin and Wang, J. and Mulchandani, A. and Keusgen, M.}, title = {Direktnachweis von Pestiziden und Cyanid mit elektrochemischen Enzymsensoren}, series = {Sensoren und Messsysteme 2004 : Tagung Ludwigsburg, 15. und 16. M{\"a}rz 2004 / VDI-VDE-Gesellschaft Mess- und Automatisierungstechnik}, journal = {Sensoren und Messsysteme 2004 : Tagung Ludwigsburg, 15. und 16. M{\"a}rz 2004 / VDI-VDE-Gesellschaft Mess- und Automatisierungstechnik}, publisher = {VDI}, address = {D{\"u}sseldorf}, isbn = {3-18-091829-2}, pages = {699 -- 706}, year = {2004}, language = {en} } @article{SchoeningKrauseBlocketal.2002, author = {Sch{\"o}ning, Michael Josef and Krause, R. and Block, Kirstin and Musameh, M. and Mulchandani, A. and Wang, J.}, title = {A dual amperometric / potentiometric FIA-based biosensor for the distinctive detection of organophosphorus pesticides}, series = {Book of abstracts / ed. by J. Saneistr.}, journal = {Book of abstracts / ed. by J. Saneistr.}, publisher = {Czech Technical University, Faculty of Electrical Engineering, Department of Measurement}, address = {Prague}, isbn = {80-01-02576-4}, pages = {76 -- 79}, year = {2002}, language = {en} } @article{AkimbekovDigelZhubanovaetal.2024, author = {Akimbekov, Nuraly and Digel, Ilya and Zhubanova, Azhar and Tastambek, Kuanysh T. and Tepecik, Atakan and Sherelkhan, Dinara}, title = {Biotechnological potentials of surfactants in coal utilization: a review}, series = {Environmental Science and Pollution Research}, volume = {31}, journal = {Environmental Science and Pollution Research}, publisher = {Springer}, address = {Berlin}, issn = {1614-7499}, doi = {10.1007/s11356-024-34892-5}, pages = {55099 -- 55118}, year = {2024}, abstract = {The quest for scientifically advanced and sustainable solutions is driven by growing environmental and economic issues associated with coal mining, processing, and utilization. Consequently, within the coal industry, there is a growing recognition of the potential of microbial applications in fostering innovative technologies. Microbial-based coal solubilization, coal beneficiation, and coal dust suppression are green alternatives to traditional thermochemical and leaching technologies and better meet the need for ecologically sound and economically viable choices. Surfactant-mediated approaches have emerged as powerful tools for modeling, simulation, and optimization of coal-microbial systems and continue to gain prominence in clean coal fuel production, particularly in microbiological co-processing, conversion, and beneficiation. Surfactants (surface-active agents) are amphiphilic compounds that can reduce surface tension and enhance the solubility of hydrophobic molecules. A wide range of surfactant properties can be achieved by either directly influencing microbial growth factors, stimulants, and substrates or indirectly serving as frothers, collectors, and modifiers in the processing and utilization of coal. This review highlights the significant biotechnological potential of surfactants by providing a thorough overview of their involvement in coal biodegradation, bioprocessing, and biobeneficiation, acknowledging their importance as crucial steps in coal consumption.}, language = {en} } @article{FreyerKemptKloeser2024, author = {Freyer, Nils and Kempt, Hendrik and Kl{\"o}ser, Lars}, title = {Easy-read and large language models: on the ethical dimensions of LLM-based text simplification}, series = {Ethics and Information Technology}, volume = {26}, journal = {Ethics and Information Technology}, publisher = {Springer}, address = {Dortrecht}, issn = {1388-1957 (Print)}, doi = {10.1007/s10676-024-09792-4}, pages = {10 Seiten}, year = {2024}, abstract = {The production of easy-read and plain language is a challenging task, requiring well-educated experts to write context-dependent simplifications of texts. Therefore, the domain of easy-read and plain language is currently restricted to the bare minimum of necessary information. Thus, even though there is a tendency to broaden the domain of easy-read and plain language, the inaccessibility of a significant amount of textual information excludes the target audience from partaking or entertainment and restricts their ability to live life autonomously. Large language models can solve a vast variety of natural language tasks, including the simplification of standard language texts to easy-read or plain language. Moreover, with the rise of generative models like GPT, easy-read and plain language may be applicable to all kinds of natural language texts, making formerly inaccessible information accessible to marginalized groups like, a.o., non-native speakers, and people with mental disabilities. In this paper, we argue for the feasibility of text simplification and generation in that context, outline the ethical dimensions, and discuss the implications for researchers in the field of ethics and computer science.}, language = {en} } @article{MyburghJacobszBothaLeRouxKotliaretal.2024, author = {Myburgh-Jacobsz, Catharina Elizabeth and Botha-Le Roux, Shani and Kotliar, Konstantin and Wentzel, Annemarie and Jacobs, Adriaan and De Boever, Patrick and Goswami, Nandu and Strijdom, Hans and Smith, Wayne}, title = {Retinal vessel functional responses in South Africans living with and without HIV: the EndoAfrica-NWU study}, series = {Microcirculation}, journal = {Microcirculation}, number = {Early View}, publisher = {Wiley}, address = {Malden, MA}, issn = {1073-9688 (Print)}, doi = {10.1111/micc.12878}, pages = {11 Seiten}, year = {2024}, language = {en} } @article{BaroudWuBohneretal.2003, author = {Baroud, Gamal and Wu, J.Z. and Bohner, Marc and Sponagel, Stefan and Steffen, Thomas}, title = {How to determine the permeability for cement infiltration into osteoporotic cancellous bone}, series = {Medical Engineering \& Physics. 25 (2003), H. 4}, journal = {Medical Engineering \& Physics. 25 (2003), H. 4}, issn = {1350-4533}, pages = {283 -- 288}, year = {2003}, abstract = {Cement augmentation is an emerging surgical procedure in which bone cement is used to infiltrate and reinforce osteoporotic vertebrae. Although this infiltration procedure has been widely applied, it is performed empirically and little is known about the flow characteristics of cement during the injection process. We present a theoretical and experimental approach to investigate the intertrabecular bone permeability during the infiltration procedure. The cement permeability was considered to be dependent on time, bone porosity, and cement viscosity in our analysis. In order to determine the time-dependent permeability, ten cancellous bone cores were harvested from osteoporotic vertebrae, infiltrated with acrylic cement at a constant flow rate, and the pressure drop across the cores during the infiltration was measured. The viscosity dependence of the permeability was determined based on published experimental data. The theoretical model for the permeability as a function of bone porosity and time was then fit to the testing data. Our findings suggest that the intertrabecular bone permeability depends strongly on time. For instance, the initial permeability (60.89 mm4/N.s) reduced to approximately 63\% of its original value within 18 seconds. This study is the first to analyze cement flow through osteoporotic bone. The theoretical and experimental models provided in this paper are generic. Thus, they can be used to systematically study and optimize the infiltration process for clinical practice.}, subject = {Osteoporose}, language = {en} } @inproceedings{BohrnStuetzFleischeretal.2012, author = {Bohrn, Ulrich and St{\"u}tz, Evamaria and Fleischer, M. and Sch{\"o}ning, Michael Josef and Wagner, P.}, title = {Towards a paradigm change - mammalian cells as sensitive biosensor layers for the detection of unexpected toxic substances in air}, series = {Nanoscale Science and Technology (NS\&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012}, booktitle = {Nanoscale Science and Technology (NS\&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012}, editor = {Abdelghani, Adnane and Sch{\"o}ning, Michael Josef}, pages = {44 -- 44}, year = {2012}, language = {en} } @article{SeynnesBojsenMollerAlbrachtetal.2015, author = {Seynnes, Olivier R. and Bojsen-M{\o}ller, Jens and Albracht, Kirsten and Arndt, Anton and Cronin, Neil J. and Finni, Taija and Magnusson, Stig Peter}, title = {Ultrasound-based testing of tendon mechanical properties: a critical evaluation}, series = {Journal of Applied Physiology}, volume = {118}, journal = {Journal of Applied Physiology}, number = {2}, issn = {8750-7587}, doi = {10.1152/japplphysiol.00849.2014}, pages = {133 -- 141}, year = {2015}, language = {en} } @article{BohrnStuetzFuchsetal.2012, author = {Bohrn, Ulrich and St{\"u}tz, Evamaria and Fuchs, Karen and Fleischer, M. and Sch{\"o}ning, Michael Josef and Wagner, P.}, title = {Monitoring of irritant gas using a whole-cell-based sensor system}, series = {Sensors and Actuators B: Chemical}, volume = {175}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2012.05.088}, pages = {208 -- 217}, year = {2012}, abstract = {Cell-based sensors for the detection of gases have long been underrepresented, due to the cellular requirement of being cultured in a liquid environment. In this work we established a cell-based gas biosensor for the detection of toxic substances in air, by adapting a commercial sensor chip (Bionas®), previously used for the measurement of pollutants in liquids. Cells of the respiratory tract (A549, RPMI 2650, V79), which survive at a gas phase in a natural context, are used as biological receptors. The physiological cell parameters acidification, respiration and morphology are continuously monitored in parallel. Ammonia was used as a highly water-soluble model gas to test the feasibility of the sensor system. Infrared measurements confirmed the sufficiency of the medium draining method. This sensor system provides a basis for many sensor applications such as environmental monitoring, building technology and public security.}, language = {en} } @article{BohrnStuetzFuchsetal.2011, author = {Bohrn, Ulrich and St{\"u}tz, Evamaria and Fuchs, Karen and Fleischer, M. and Sch{\"o}ning, Michael Josef and Wagner, P.}, title = {Air Quality Monitoring using a Whole-Cell based Sensor System}, series = {Procedia Engineering. 25 (2011)}, journal = {Procedia Engineering. 25 (2011)}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1877-7058}, pages = {1421 -- 1424}, year = {2011}, language = {en} } @misc{BurgethKleefeldNaegeletal.2020, author = {Burgeth, Bernhard and Kleefeld, Andreas and Naegel, Beno{\^i}t and Perret, Benjamin}, title = {Editorial — Special Issue: ISMM 2019}, series = {Mathematical Morphology - Theory and Applications}, volume = {4}, journal = {Mathematical Morphology - Theory and Applications}, number = {1}, publisher = {De Gruyter}, address = {Warschau}, issn = {2353-3390}, doi = {10.1515/mathm-2020-0200}, pages = {159 -- 161}, year = {2020}, abstract = {This editorial presents the Special Issue dedicated to the conference ISMM 2019 and summarizes the articles published in this Special Issue.}, language = {en} } @article{KleefeldZimmermann2022, author = {Kleefeld, Andreas and Zimmermann, M.}, title = {Computing Elastic Interior Transmission Eigenvalues}, series = {Integral Methods in Science and Engineering}, journal = {Integral Methods in Science and Engineering}, editor = {Constanda, Christian and Bodmann, Bardo E.J. and Harris, Paul J.}, publisher = {Birkh{\"a}user}, address = {Cham}, isbn = {978-3-031-07171-3}, doi = {10.1007/978-3-031-07171-3_10}, pages = {139 -- 155}, year = {2022}, abstract = {An alternative method is presented to numerically compute interior elastic transmission eigenvalues for various domains in two dimensions. This is achieved by discretizing the resulting system of boundary integral equations in combination with a nonlinear eigenvalue solver. Numerical results are given to show that this new approach can provide better results than the finite element method when dealing with general domains.}, language = {en} } @incollection{PieronekKleefeld2019, author = {Pieronek, Lukas and Kleefeld, Andreas}, title = {The Method of Fundamental Solutions for Computing Interior Transmission Eigenvalues of Inhomogeneous Media}, series = {Integral Methods in Science and Engineering: Analytic Treatment and Numerical Approximations}, booktitle = {Integral Methods in Science and Engineering: Analytic Treatment and Numerical Approximations}, editor = {Constanda, Christian and Harris, Paul}, publisher = {Birkh{\"a}user}, address = {Cham}, isbn = {978-3-030-16077-7}, doi = {10.1007/978-3-030-16077-7_28}, pages = {353 -- 365}, year = {2019}, abstract = {The method of fundamental solutions is applied to the approximate computation of interior transmission eigenvalues for a special class of inhomogeneous media in two dimensions. We give a short approximation analysis accompanied with numerical results that clearly prove practical convenience of our alternative approach.}, language = {en} } @misc{NamAroraBehbahanietal.2010, author = {Nam, J. and Arora, D. and Behbahani, Mehdi and Probst, M. and Benkowski, R. and Behr, Marek and Pasquali, M.}, title = {New computational method in hemolysis analysis for artificial heart pump}, series = {ASAIO Journal}, volume = {56}, journal = {ASAIO Journal}, number = {2}, publisher = {Lippincott Williams \& Wilkins}, address = {Philadelphia}, doi = {10.1097/01.mat.0000369377.65122.a3}, pages = {98}, year = {2010}, abstract = {The MicroMed DeBakey ventricular assist device is an axial flow pump designed for providing long-term support to end-stage heartfailure patients. Previously, we presented computational analysis of the blood pump flow. From the analysis, we were able to identify regions of high shear and recirculating flow that may cause blood damage, for example, deformation and fragmentation of the red blood cell (RBC). This mechanical hemolysis can be predicted using a tensor-based blood damage model that is based on the physical properties of the RBCs, for example, the relaxation time of the RBC membrane. However, an extensive and detailed analysis was complicated by the fact that the previous method predicts hemolysis along a finite number of pathlines traversed by the RBCs, possibly omitting parts of the flow domain. Furthermore, it is computationally expensive and is not easily parallelizable. Here, we propose a new method to estimate hemolysis. The method is based on treating the shape of droplet (tensor) as a field variable, like velocity in the Navier-Stokes system. The governing equation for the RBC shape is treated by least-squares finite element method and the volume conservation of the RBC is augmented by Lagrangian multiplier. Unlike the previous method, the proposed method can visualize areas of high RBC strain that is potentially dangerous for mechanical hemolysis. Also, the amount of plasma-free hemoglobin and, consequently, normalized index of hemolysis can be computed as a byproduct. The method is tested in a simple shear flow for validation and an artery graft flow is chosen to show its potential usefulness. Finally, the method is applied to the blood damage estimation for the pump.}, language = {en} } @inproceedings{BremmBlaneckBornheimetal.2024, author = {Bremm, Florian and Blaneck, Patrick Gustav and Bornheim, Tobias and Grieger, Niklas and Bialonski, Stephan}, title = {Detecting Sexism in German Online Newspaper Comments with Open-Source Text Embeddings (Team GDA, GermEval2024 Shared Task 1: GerMS-Detect, Subtasks 1 and 2, Closed Track)}, series = {Proceedings of GermEval 2024 Task 1 GerMS-Detect Workshop on Sexism Detection in German Online News Fora (GerMS-Detect 2024)}, booktitle = {Proceedings of GermEval 2024 Task 1 GerMS-Detect Workshop on Sexism Detection in German Online News Fora (GerMS-Detect 2024)}, publisher = {ACL}, address = {Kerrville}, doi = {10.48550/arXiv.2403.08592}, pages = {33 -- 38}, year = {2024}, abstract = {Sexism in online media comments is a pervasive challenge that often manifests subtly, complicating moderation efforts as interpretations of what constitutes sexism can vary among individuals. We study monolingual and multilingual open-source text embeddings to reliably detect sexism and misogyny in Germanlanguage online comments from an Austrian newspaper. We observed classifiers trained on text embeddings to mimic closely the individual judgements of human annotators. Our method showed robust performance in the GermEval 2024 GerMS-Detect Subtask 1 challenge, achieving an average macro F1 score of 0.597 (4th place, as reported on Codabench). It also accurately predicted the distribution of human annotations in GerMS-Detect Subtask 2, with an average Jensen-Shannon distance of 0.301 (2nd place). The computational efficiency of our approach suggests potential for scalable applications across various languages and linguistic contexts.}, language = {en} } @article{MuribYeapEurlingsetal.2016, author = {Murib, Mohammed Sharif and Yeap, Weng Siang and Eurlings, Y. and Grinsven, Bart van and Boyen, Hans-Gerd and Conings, Bert and Michiels, Luc and Ameloot, Marcel and Carleer, R. and Warmer, Johannes and Kaul, Peter Michael and Haenen, Ken and Sch{\"o}ning, Michael Josef and de Ceuninck, Ward A. and Wagner, Patrick Hermann}, title = {Heat-transfer based characterization of DNA on synthetic sapphire chips}, series = {Sensors and Actuators B: Chemical}, volume = {230}, journal = {Sensors and Actuators B: Chemical}, number = {230}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2016.02.027}, pages = {260 -- 271}, year = {2016}, abstract = {In this study, we show that synthetic sapphire (Al₂O₃), an established implant material, can also serve as a platform material for biosensors comparable to nanocrystalline diamond. Sapphire chips, beads, and powder were first modified with (3-aminopropyl) triethoxysilane (APTES), followed by succinic anhydride (SA), and finally single-stranded probe DNA was EDC coupled to the functionalized layer. The presence of the APTES-SA layer on sapphire powders was confirmed by thermogravimetric analyis and Fourier-transform infrared spectroscopy. Using planar sapphire chips as substrates and X-ray photoelectron spectroscopy (XPS) as surface-sensitive tool, the sequence of individual layers was analyzed with respect to their chemical state, enabling the quantification of areal densities of the involved molecular units. Fluorescence microscopy was used to demonstrate the hybridization of fluorescently tagged target DNA to the probe DNA, including denaturation- and re-hybridization experiments. Due to its high thermal conductivity, synthetic sapphire is especially suitable as a chip material for the heat-transfer method, which was employed to distinguish complementary- and non-complementary DNA duplexes containing single-nucleotide polymorphisms. These results indicate that it is possible to detect mutations electronically with a chemically resilient and electrically insulating chip material.}, language = {en} } @article{ZiemonsHerzogBosettietal.1992, author = {Ziemons, Karl and Herzog, Hans and Bosetti, P. and Feinendegen, L. E.}, title = {Iterative image reconstruction with weighted pixel contribution to projection elements}, series = {European Journal of Nuclear Medicine}, volume = {19}, journal = {European Journal of Nuclear Medicine}, number = {8}, isbn = {1619-7089}, pages = {588 -- 588}, year = {1992}, language = {en} } @article{RichterBraunsteinStaeudleetal.2021, author = {Richter, Charlotte and Braunstein, Bjoern and Staeudle, Benjamin and Attias, Julia and Suess, Alexander and Weber, Tobias and Mileva, Katya N. and Rittweger, Joern and Green, David A. and Albracht, Kirsten}, title = {Contractile behavior of the gastrocnemius medialis muscle during running in simulated hypogravity}, series = {npj Microgravity}, volume = {7}, journal = {npj Microgravity}, number = {Article number: 32}, publisher = {Springer Nature}, address = {New York}, issn = {2373-8065}, doi = {10.1038/s41526-021-00155-7}, pages = {7 Seiten}, year = {2021}, abstract = {Vigorous exercise countermeasures in microgravity can largely attenuate muscular degeneration, albeit the extent of applied loading is key for the extent of muscle wasting. Running on the International Space Station is usually performed with maximum loads of 70\% body weight (0.7 g). However, it has not been investigated how the reduced musculoskeletal loading affects muscle and series elastic element dynamics, and thereby force and power generation. Therefore, this study examined the effects of running on the vertical treadmill facility, a ground-based analog, at simulated 0.7 g on gastrocnemius medialis contractile behavior. The results reveal that fascicle-series elastic element behavior differs between simulated hypogravity and 1 g running. Whilst shorter peak series elastic element lengths at simulated 0.7 g appear to be the result of lower muscular and gravitational forces acting on it, increased fascicle lengths and decreased velocities could not be anticipated, but may inform the development of optimized running training in hypogravity. However, whether the alterations in contractile behavior precipitate musculoskeletal degeneration warrants further study.}, language = {en} } @article{BaeckerRaueSchusseretal.2012, author = {B{\"a}cker, Matthias and Raue, Markus and Schusser, Sebastian and Jeitner, C. and Breuer, Lars and Wagner, P. and Poghossian, Arshak and F{\"o}rster, Arnold and Mang, Thomas and Sch{\"o}ning, Michael Josef}, title = {Microfluidic chip with integrated microvalves based on temperature- and pH-responsive hydrogel thin films}, series = {Physica Status Solidi (a)}, volume = {209}, journal = {Physica Status Solidi (a)}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201100763}, pages = {839 -- 845}, year = {2012}, abstract = {Two types of microvalves based on temperature-responsive poly(N-isopropylacrylamide) (PNIPAAm) and pH-responsive poly(sodium acrylate) (PSA) hydrogel films have been developed and tested. The PNIPAAm and PSA hydrogel films were prepared by means of in situ photopolymerization directly inside the fluidic channel of a microfluidic chip fabricated by combining Si and SU-8 technologies. The swelling/shrinking properties and height changes of the PNIPAAm and PSA films inside the fluidic channel were studied at temperatures of deionized water from 14 to 36 °C and different pH values (pH 3-12) of Titrisol buffer, respectively. Additionally, in separate experiments, the lower critical solution temperature (LCST) of the PNIPAAm hydrogel was investigated by means of a differential scanning calorimetry (DSC) and a surface plasmon resonance (SPR) method. Mass-flow measurements have shown the feasibility of the prepared hydrogel films to work as an on-chip integrated temperature- or pH-responsive microvalve capable to switch the flow channel on/off.}, language = {en} } @article{BaeckerKramerHucketal.2014, author = {B{\"a}cker, Matthias and Kramer, F. and Huck, Christina and Poghossian, Arshak and Bratov, Andrey V. and Abramova, N. and Sch{\"o}ning, Michael Josef}, title = {Planar and 3D interdigitated electrodes for biosensing applications: The impact of a dielectric barrier on the sensor properties}, series = {Physica Status Solidi (A) - Applications and Materials Science}, volume = {211}, journal = {Physica Status Solidi (A) - Applications and Materials Science}, number = {6}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1521-396X (E-Journal); 1862-6319 (E-Journal); 0031-8965 (Print); 1862-6300 (Print)}, doi = {10.1002/pssa.201330416}, pages = {1357 -- 1363}, year = {2014}, abstract = {Planar and three-dimensional (3D) interdigitated electrodes (IDE) with electrode digits separated by an insulating barrier of different heights were electrochemically characterized and compared in terms of their sensing properties. Due to the impact of the surface resistance, both types of IDE structures display a non-linear behavior in low-ionic strength solutions. The experimental data were fitted to an electrical equivalent circuit and interpreted taking into account the surface-charge-governed properties. The effect of a charged polyelectrolyte layer electrostatically assembled onto the sensor surface on the surface resistance in solutions with different KCl concentration is studied. In case of the same electrode footprint, 3D-IDEs show a larger cell constant and a higher sensitivity to molecular adsorption than that of planar IDEs. The obtained results demonstrate the potential of 3D-IDEs as a new transducer structure for a direct label-free sensing of charged molecules.}, language = {en} } @article{KloockMorenoBratovetal.2006, author = {Kloock, Joachim P. and Moreno, Lia and Bratov, Andrey V. and Huachupoma, S. and Xu, Jingjuan and Wagner, Torsten and Yoshinobu, Tatsuo and Ermolenko, Y. E. and Vlasov, Yu G. G. and Sch{\"o}ning, Michael Josef}, title = {PLD-prepared cadmium sensors based on chalcogenide glasses —ISFET, LAPS and \&\#956;ISE semiconductor structures}, series = {Sensors and Actuators B: Chemical. 118 (2006), H. 1-2}, journal = {Sensors and Actuators B: Chemical. 118 (2006), H. 1-2}, isbn = {0925-4005}, pages = {149 -- 155}, year = {2006}, language = {en} } @inproceedings{RichterBraunsteinStaeudleetal.2018, author = {Richter, Charlotte and Braunstein, Bjoern and St{\"a}udle, Benjamin and Attias, Julia and Suess, Alexander and Weber, T. and Rittweger, Joern and Green, David A. and Albracht, Kirsten}, title = {In vivo fascicle length of the gastrocnemius muscle during walking in simulated martian gravity using two different body weight support devices}, series = {23rd Annual Congress of the European College of Sport Science, Dublin, Irland}, booktitle = {23rd Annual Congress of the European College of Sport Science, Dublin, Irland}, year = {2018}, language = {en} } @inproceedings{GoldmannBraunsteinHeinrichetal.2015, author = {Goldmann, Jan-Peter and Braunstein, Bjoern and Heinrich, Kai and Sanno, Maximilian and St{\"a}udle, Benjamin and Ritzdorf, Wolfgang and Br{\"u}ggemann, Gert-Peter and Albracht, Kirsten}, title = {Joint work of the take-off leg during elite high jump}, series = {Proceedings of the 33th International Conference on Biomechanics in Sports (ISBS)}, booktitle = {Proceedings of the 33th International Conference on Biomechanics in Sports (ISBS)}, pages = {3 S.}, year = {2015}, language = {en} } @inproceedings{KloockSchubertErmelenkoetal.2006, author = {Kloock, Joachim P. and Schubert, J. and Ermelenko, Y. and Vlasov, Y. G. and Bratov, Andrey V. and Sch{\"o}ning, Michael Josef}, title = {Thin-film sensors with chalcogenide glass materials - a general survey}, series = {Biochemical sensing utilisation of micro- and nanotechnologies : Warsaw, [23rd - 26th] November 2005 / ed. by M. Mascini ...}, booktitle = {Biochemical sensing utilisation of micro- and nanotechnologies : Warsaw, [23rd - 26th] November 2005 / ed. by M. Mascini ...}, address = {Warsaw}, pages = {92 -- 97}, year = {2006}, language = {en} } @article{KetelhutGoellBraunsteinetal.2018, author = {Ketelhut, Maike and G{\"o}ll, Fabian and Braunstein, Bj{\"o}rn and Albracht, Kirsten and Abel, Dirk}, title = {Comparison of different training algorithms for the leg extension training with an industrial robot}, series = {Current Directions in Biomedical Engineering}, volume = {4}, journal = {Current Directions in Biomedical Engineering}, number = {1}, publisher = {De Gruyter}, address = {Berlin}, issn = {2364-5504}, doi = {10.1515/cdbme-2018-0005}, pages = {17 -- 20}, year = {2018}, abstract = {In the past, different training scenarios have been developed and implemented on robotic research platforms, but no systematic analysis and comparison have been done so far. This paper deals with the comparison of an isokinematic (motion with constant velocity) and an isotonic (motion against constant weight) training algorithm. Both algorithms are designed for a robotic research platform consisting of a 3D force plate and a high payload industrial robot, which allows leg extension training with arbitrary six-dimensional motion trajectories. In the isokinematic as well as the isotonic training algorithm, individual paths are defined i n C artesian s pace by sufficient s upport p oses. I n t he i sotonic t raining s cenario, the trajectory is adapted to the measured force as the robot should only move along the trajectory as long as the force applied by the user exceeds a minimum threshold. In the isotonic training scenario however, the robot's acceleration is a function of the force applied by the user. To validate these findings, a simulative experiment with a simple linear trajectory is performed. For this purpose, the same force path is applied in both training scenarios. The results illustrate that the algorithms differ in the force dependent trajectory adaption.}, language = {en} } @article{KetelhutBrueggeGoelletal.2020, author = {Ketelhut, Maike and Br{\"u}gge, G. M. and G{\"o}ll, Fabian and Braunstein, Bjoern and Albracht, Kirsten and Abel, Dirk}, title = {Adaptive iterative learning control of an industrial robot during neuromuscular training}, series = {IFAC PapersOnLine}, volume = {53}, journal = {IFAC PapersOnLine}, number = {2}, publisher = {Elsevier}, address = {Amsterdam}, issn = {2405-8963}, doi = {10.1016/j.ifacol.2020.12.741}, pages = {16468 -- 16475}, year = {2020}, abstract = {To prevent the reduction of muscle mass and loss of strength coming along with the human aging process, regular training with e.g. a leg press is suitable. However, the risk of training-induced injuries requires the continuous monitoring and controlling of the forces applied to the musculoskeletal system as well as the velocity along the motion trajectory and the range of motion. In this paper, an adaptive norm-optimal iterative learning control algorithm to minimize the knee joint loadings during the leg extension training with an industrial robot is proposed. The response of the algorithm is tested in simulation for patients with varus, normal and valgus alignment of the knee and compared to the results of a higher-order iterative learning control algorithm, a robust iterative learning control and a recently proposed conventional norm-optimal iterative learning control algorithm. Although significant improvements in performance are made compared to the conventional norm-optimal iterative learning control algorithm with a small learning factor, for the developed approach as well as the robust iterative learning control algorithm small steady state errors occur.}, language = {en} } @inproceedings{KetelhutGoellBraunsteinetal.2019, author = {Ketelhut, Maike and G{\"o}ll, Fabian and Braunstein, Bjoern and Albracht, Kirsten and Abel, Dirk}, title = {Iterative learning control of an industrial robot for neuromuscular training}, series = {2019 IEEE Conference on Control Technology and Applications}, booktitle = {2019 IEEE Conference on Control Technology and Applications}, publisher = {IEEE}, address = {New York}, isbn = {978-1-7281-2767-5 (ePub)}, doi = {10.1109/CCTA.2019.8920659}, pages = {7 Seiten}, year = {2019}, abstract = {Effective training requires high muscle forces potentially leading to training-induced injuries. Thus, continuous monitoring and controlling of the loadings applied to the musculoskeletal system along the motion trajectory is required. In this paper, a norm-optimal iterative learning control algorithm for the robot-assisted training is developed. The algorithm aims at minimizing the external knee joint moment, which is commonly used to quantify the loading of the medial compartment. To estimate the external knee joint moment, a musculoskeletal lower extremity model is implemented in OpenSim and coupled with a model of an industrial robot and a force plate mounted at its end-effector. The algorithm is tested in simulation for patients with varus, normal and valgus alignment of the knee. The results show that the algorithm is able to minimize the external knee joint moment in all three cases and converges after less than seven iterations.}, language = {en} } @article{HerssensCowburnAlbrachtetal.2022, author = {Herssens, Nolan and Cowburn, James and Albracht, Kirsten and Braunstein, Bjoern and Cazzola, Dario and Colyer, Steffi and Minetti, Alberto E. and Pavei, Gaspare and Rittweger, J{\"o}rn and Weber, Tobias and Green, David A.}, title = {Movement in low gravity environments (MoLo) programme - the MoLo-L.O.O.P. study protocol}, series = {PLOS ONE / Public Library of Science}, volume = {17}, journal = {PLOS ONE / Public Library of Science}, number = {11}, editor = {Cattaneo, Luigi}, publisher = {Plos}, address = {San Francisco}, issn = {1932-6203}, doi = {10.1371/journal.pone.0278051}, pages = {e0278051}, year = {2022}, abstract = {Exposure to prolonged periods in microgravity is associated with deconditioning of the musculoskeletal system due to chronic changes in mechanical stimulation. Given astronauts will operate on the Lunar surface for extended periods of time, it is critical to quantify both external (e.g., ground reaction forces) and internal (e.g., joint reaction forces) loads of relevant movements performed during Lunar missions. Such knowledge is key to predict musculoskeletal deconditioning and determine appropriate exercise countermeasures associated with extended exposure to hypogravity.}, language = {en} } @inproceedings{BraunsteinGoldmannAlbrachtetal.2013, author = {Braunstein, Bjoern and Goldmann, Jan-Peter and Albracht, Kirsten and Sanno, Maximilian and Willwacher, Steffen and Heinrich, Kai and Herrmann, Volker and Br{\"u}ggemann, Gert-Peter}, title = {Joint specific contribution of mechanical power and work during acceleration and top speed in elite sprinters}, series = {31 International Conference on Biomechanics in Sports, Taipei, Taiwan, July 07 - July 22, 2013}, booktitle = {31 International Conference on Biomechanics in Sports, Taipei, Taiwan, July 07 - July 22, 2013}, issn = {1999-4168}, year = {2013}, language = {en} } @article{RichterBraunsteinStaeudleetal.2021, author = {Richter, Charlotte and Braunstein, Bjoern and St{\"a}udle, Benjamin and Attias, Julia and Suess, Alexander and Weber, Tobias and Mileva, Katja N. and Rittweger, Joern and Green, David A. and Albracht, Kirsten}, title = {Gastrocnemius medialis contractile behavior is preserved during 30\% body weight supported gait training}, series = {Frontiers in Sports and Active Living}, volume = {2021}, journal = {Frontiers in Sports and Active Living}, number = {2}, publisher = {Frontiers}, address = {Lausanne}, issn = {2624-9367}, doi = {10.3389/fspor.2020.614559}, pages = {Artikel 614559}, year = {2021}, abstract = {Rehabilitative body weight supported gait training aims at restoring walking function as a key element in activities of daily living. Studies demonstrated reductions in muscle and joint forces, while kinematic gait patterns appear to be preserved with up to 30\% weight support. However, the influence of body weight support on muscle architecture, with respect to fascicle and series elastic element behavior is unknown, despite this having potential clinical implications for gait retraining. Eight males (31.9 ± 4.7 years) walked at 75\% of the speed at which they typically transition to running, with 0\% and 30\% body weight support on a lower-body positive pressure treadmill. Gastrocnemius medialis fascicle lengths and pennation angles were measured via ultrasonography. Additionally, joint kinematics were analyzed to determine gastrocnemius medialis muscle-tendon unit lengths, consisting of the muscle's contractile and series elastic elements. Series elastic element length was assessed using a muscle-tendon unit model. Depending on whether data were normally distributed, a paired t-test or Wilcoxon signed rank test was performed to determine if body weight supported walking had any effects on joint kinematics and fascicle-series elastic element behavior. Walking with 30\% body weight support had no statistically significant effect on joint kinematics and peak series elastic element length. Furthermore, at the time when peak series elastic element length was achieved, and on average across the entire stance phase, muscle-tendon unit length, fascicle length, pennation angle, and fascicle velocity were unchanged with respect to body weight support. In accordance with unchanged gait kinematics, preservation of fascicle-series elastic element behavior was observed during walking with 30\% body weight support, which suggests transferability of gait patterns to subsequent unsupported walking.}, language = {en} } @article{KaramanidisAlbrachtBraunsteinetal.2011, author = {Karamanidis, Kiros and Albracht, Kirsten and Braunstein, Bjoern and Catala, Maria Moreno and Goldmann, Jan-Peter and Br{\"u}ggemann, Gert-Peter}, title = {Lower leg musculoskeletal geometry and sprint performance}, series = {Gait and Posture}, volume = {34}, journal = {Gait and Posture}, number = {1}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0966-6362}, doi = {10.1016/j.gaitpost.2011.03.009}, pages = {138 -- 141}, year = {2011}, abstract = {The purpose of this study was to investigate whether sprint performance is related to lower leg musculoskeletal geometry within a homogeneous group of highly trained 100-m sprinters. Using a cluster analysis, eighteen male sprinters were divided into two groups based on their personal best (fast: N = 11, 10.30 ± 0.07 s; slow: N = 7, 10.70 ± 0.08 s). Calf muscular fascicle arrangement and Achilles tendon moment arms (calculated by the gradient of tendon excursion versus ankle joint angle) were analyzed for each athlete using ultrasonography. Achilles tendon moment arm, foot and ankle skeletal geometry, fascicle arrangement as well as the ratio of fascicle length to Achilles tendon moment arm showed no significant (p > 0.05) correlation with sprint performance, nor were there any differences in the analyzed musculoskeletal parameters between the fast and slow sprinter group. Our findings provide evidence that differences in sprint ability in world-class athletes are not a result of differences in the geometrical design of the lower leg even when considering both skeletal and muscular components.}, language = {en} } @article{KetelhutKolditzGoelletal.2019, author = {Ketelhut, Maike and Kolditz, Melanie and G{\"o}ll, Fabian and Braunstein, Bjoern and Albracht, Kirsten and Abel, Dirk}, title = {Admittance control of an industrial robot during resistance training}, series = {IFAC-PapersOnLine}, volume = {52}, journal = {IFAC-PapersOnLine}, number = {19}, publisher = {Elsevier}, address = {Amsterdam}, issn = {2405-8963}, doi = {10.1016/j.ifacol.2019.12.102}, pages = {223 -- 228}, year = {2019}, abstract = {Neuromuscular strength training of the leg extensor muscles plays an important role in the rehabilitation and prevention of age and wealth related diseases. In this paper, we focus on the design and implementation of a Cartesian admittance control scheme for isotonic training, i.e. leg extension and flexion against a predefined weight. For preliminary testing and validation of the designed algorithm an experimental research and development platform consisting of an industrial robot and a force plate mounted at its end-effector has been used. Linear, diagonal and arbitrary two-dimensional motion trajectories with different weights for the leg extension and flexion part are applied. The proposed algorithm is easily adaptable to trajectories consisting of arbitrary six-dimensional poses and allows the implementation of individualized trajectories.}, language = {en} } @inproceedings{DroszezSannoGoldmannetal.2016, author = {Droszez, Anna and Sanno, Maximilian and Goldmann, Jan-Peter and Albracht, Kirsten and Br{\"u}ggemann, Gert-Peter and Braunstein, Bjoern}, title = {Differences between take-off behavior during vertical jumps and two artistic elements}, series = {34th International Conference of Biomechanics in Sport, Tsukuba, Japan, July 18-22, 2016}, booktitle = {34th International Conference of Biomechanics in Sport, Tsukuba, Japan, July 18-22, 2016}, issn = {1999-4168}, pages = {577 -- 580}, year = {2016}, language = {en} } @article{RichterBraunsteinWinnardetal.2017, author = {Richter, Charlotte and Braunstein, Bjoern and Winnard, Andrew and Nasser, Mona and Weber, T.}, title = {Human Biomechanical and Cardiopulmonary Responses to Partial Gravity - A Systematic Review}, series = {Frontiers in physiology}, journal = {Frontiers in physiology}, number = {8, article 583}, doi = {10.3389/fphys.2017.00583}, pages = {22 Seiten}, year = {2017}, language = {en} } @inproceedings{MorenoDosevBratovetal.2006, author = {Moreno, Lia and Dosev, D. and Bratov, Andrey V. and Dominguez, C. and Sch{\"o}ning, Michael Josef and Kloock, Joachim P.}, title = {Effect of electrical properties of the surrounding medium on the response of an interdigitated electrode array with chalcogenide glass film}, series = {XX Eurosensors : 20th anniversary ; G{\"o}teborg, Sweden, 17 - 20 September 2006 ; [proceedings]. - Vol. 1}, booktitle = {XX Eurosensors : 20th anniversary ; G{\"o}teborg, Sweden, 17 - 20 September 2006 ; [proceedings]. - Vol. 1}, address = {G{\"o}teborg}, isbn = {978-91-631-9280-7}, pages = {384 -- 385}, year = {2006}, language = {en} } @article{BertzSchoeningMolinnusetal.2024, author = {Bertz, Morten and Sch{\"o}ning, Michael Josef and Molinnus, Denise and Homma, Takayuki}, title = {Influence of temperature, light, and H₂O₂ concentration on microbial spore inactivation: in-situ Raman spectroscopy combined with optical trapping}, series = {Physica status solidi (a) applications and materials science}, journal = {Physica status solidi (a) applications and materials science}, number = {Early View}, publisher = {Wiley-VCH}, address = {Berlin}, issn = {1862-6319 (Online)}, doi = {10.1002/pssa.202300866}, pages = {8 Seiten}, year = {2024}, abstract = {To gain insight on chemical sterilization processes, the influence of temperature (up to 70 °C), intense green light, and hydrogen peroxide (H₂O₂) concentration (up to 30\% in aqueous solution) on microbial spore inactivation is evaluated by in-situ Raman spectroscopy with an optical trap. Bacillus atrophaeus is utilized as a model organism. Individual spores are isolated and their chemical makeup is monitored under dynamically changing conditions (temperature, light, and H₂O₂ concentration) to mimic industrially relevant process parameters for sterilization in the field of aseptic food processing. While isolated spores in water are highly stable, even at elevated temperatures of 70 °C, exposure to H₂O₂ leads to a loss of spore integrity characterized by the release of the key spore biomarker dipicolinic acid (DPA) in a concentration-dependent manner, which indicates damage to the inner membrane of the spore. Intensive light or heat, both of which accelerate the decomposition of H₂O₂ into reactive oxygen species (ROS), drastically shorten the spore lifetime, suggesting the formation of ROS as a rate-limiting step during sterilization. It is concluded that Raman spectroscopy can deliver mechanistic insight into the mode of action of H₂O₂-based sterilization and reveal the individual contributions of different sterilization methods acting in tandem.}, language = {en} } @article{MorenoiCodinachsKloockSchoeningetal.2008, author = {Moreno i Codinachs, Lia and Kloock, Joachim P. and Sch{\"o}ning, Michael Josef and Baldi, Antoni and Ipatov, Andrey and Bratov, Andrey V. and Jimenez-Jorquera, Cecilia}, title = {Electronic integrated multisensor tongue applied to grape juice and wine analysis}, series = {Analyst. 133 (2008)}, journal = {Analyst. 133 (2008)}, isbn = {1364-5528}, pages = {1440 -- 1448}, year = {2008}, language = {en} } @article{ZiemonsAuffrayBarbieretal.2005, author = {Ziemons, Karl and Auffray, Etiennette and Barbier, R{\´e}mi and Brandenburg, G. and Bruyndonckx, Peter and Choi, Yong and Christ, Daniela and Costes, Nicolas and D{\´e}clais, Yves R. A. and Devroede, Olivier and Dujardin, Christophe and Fedorovd, A. and Heinrichs, U. and Korzhik, Mikhail V. and Krieguer, Magalie and Kuntner, Claudia and Largeron, G. and Lartizien, Carole and Larue, H. and Lecoq, Paul R. and Vieira, Jean Marc}, title = {The ClearPET™ project: Development of a 2nd generation high-performance small animal PET scanner}, series = {Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, volume = {537}, journal = {Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, number = {1-2}, issn = {0168-9002}, pages = {307 -- 311}, year = {2005}, abstract = {Second generation high-performance PET scanners, called ClearPET™1, have been developed by working groups of the Crystal Clear Collaboration (CCC). High sensitivity and high spatial resolution for the ClearPET camera is achieved by using a phoswich arrangement combining two different types of lutetium-based scintillator materials: LSO from CTI and LuYAP:Ce from the CCC (ISTC project). In a first ClearPET prototype, phoswich arrangements of 8×8 crystals of 2×2×10 mm3 are coupled to multi-channel photomultiplier tubes (Hamamatsu R7600). A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the ring is 120 mm, the axial detector length is 110 mm.The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the exact pulse starting time, which is subsequently used for coincidence detection. The gantry allows rotation of the detector modules around the field of view. Preliminary data shows a correct identification of the crystal layer about (98±1)\%. Typically the energy resolution is (23.3±0.5)\% for the luyap layer and (15.4±0.4)\% for the lso layer. early studies showed the timing resolution of 2 ns FWHM and 4.8 ns FWTM. the intrinsic spatial resolution ranges from 1.37 mm to 1.61 mm full-width of half-maximum (FWHM) with a mean of 1.48 mm FWHM. further improvements in image and energy resolution are expected when the system geometry is fully modeled.}, language = {en} } @article{AuffrayBruyndonckxDevroedeetal.2004, author = {Auffray, Etiennette and Bruyndonckx, Peter and Devroede, Olivier and Fedorov, Andrei A. and Ziemons, Karl and Heinrichs, U. and Korjik, Mikhail V. and Krieguer, Magalie and Kuntner, Claudia and Lartizien, Carole and Lecoq, Paul R. and L{\´e}onard, Sophie M. A. and Morel, Christian and Mosset, Jean-Baptiste and P{\´e}drini, Christian and Petrosian, A. G. and Pietrzyk, Uwe K. and Rey, Martin and Saladino, S. and Sappey-Marinier, D. and Simon, Luc}, title = {The ClearPET project}, series = {Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, volume = {527}, journal = {Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, number = {1-2}, isbn = {0168-9002}, pages = {171 -- 174}, year = {2004}, abstract = {The Crystal Clear Collaboration has designed and is building a high-resolution small animal PET scanner. The design is based on the use of the Hamamatsu R7600-M64 multi-anode photomultiplier tube and a LSO/LuYAP phoswich matrix with one to one coupling between the crystals and the photo-detector. The complete system will have 80 PM tubes in four rings with an inner diameter of 137 mm and an axial field of view of 110 mm. The PM pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. Simulations, and measurements a 2×4 module test set-up predict a spatial resolution of 1.5 mm in the centre of the field of view and a sensitivity of 5.9\% for a point source in the centre of the field of view.}, language = {en} } @article{ZiemonsBruyndonckxPerezetal.2008, author = {Ziemons, Karl and Bruyndonckx, Peter and Perez, Jose M. and Pietrzyk, Uwe and Rato, P. and Tavernier, Stefaan}, title = {Beyond ClearPET: Next Aims}, series = {5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro Symposium Proceedings ISBI 2008}, journal = {5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro Symposium Proceedings ISBI 2008}, isbn = {978-1-4244-2003-2}, pages = {1421 -- 1424}, year = {2008}, abstract = {The CRYSTAL CLEAR collaboration, in short CCC, is a consortium of 12 academic institutions, mainly from Europe, joining efforts in the area of developing instrumentation for nuclear medicine and medical imaging. In the framework of the CCC a high performance small animal PET system, called ClearPET, was developed by using new technologies in electronics and crystals in a phoswich arrangement combining two types of lutetium- based scintillator materials: LSO:Ce and LuYAP:Ce. Our next aim will be the development of hybrid image systems. Hybrid MR-PET imaging has many unique advantages for brain research. This has sparked a new research line within CCC for the development of novel MR-PET compatible technologies. MRI is not as sensitive as PET but PET has poorer spatial resolution than MRI. Two major advantages of PET are sensitivity and its ability to acquire metabolic information. To assess these innovations, the development of a 9.4T hybrid animal MR-PET scanner is proposed based on an existing 9.4T MR scanner that will be adapted to enable simultaneous acquisition of MR and PET data using cutting- edge technology for both MR and PET.}, language = {en} } @article{WedrowskiBruyndonckxTavernieretal.2009, author = {Wedrowski, Mateusz and Bruyndonckx, Peter and Tavernier, Stefaan and Zhi, Li and Dang, Jun and Mendes, Pedro Rato and Perez, Jose Manuel and Ziemons, Karl}, title = {Robustness of neural networks algorithm for gamma detection in monolithic block detector, positron emission tomography}, series = {2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC)}, journal = {2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC)}, isbn = {1082-3654}, pages = {2625 -- 2628}, year = {2009}, abstract = {The monolithic scintillator block approach for gamma detection in the Positron Emission Tomography (PET) avoids estimating Depth of Interaction (DOI), reduces dead zones in detector and diminishes costs of detector production. Neural Networks (NN) are very efficient to determine the entrance point of a gamma incident on a scintillator block. This paper presents results on the robustness of the spatial resolution as a function of the random fraction in the data, temperature and HV fluctuations. This is important when implementing the method in a real scanner. Measurements were done with two Hamamatsu S8550 APD arrays, glued on a 20 {\~A}— 20 {\~A}— 10 mm3 monolithic LSO crystal block.}, language = {en} } @article{SlabuRoethEngelmannetal.2019, author = {Slabu, Ioana and Roeth, Anjali A. and Engelmann, Ulrich M. and Wiekhorst, Frank and Buhl, Eva Miriam and Neumann, Ulf P. and Schmitz-Rode, Thomas}, title = {Modeling of magnetoliposome uptake in human pancreatic tumor cells in vitro}, series = {Nanotechnology}, volume = {30}, journal = {Nanotechnology}, number = {18}, issn = {1361-6528}, doi = {10.1088/1361-6528/ab033e}, pages = {184004}, year = {2019}, language = {en} } @article{ArtmannKelemenPorstetal.1998, author = {Artmann, Gerhard and Kelemen, Christina and Porst, Dariusz and B{\"u}ldt, Georg and Chien, Shu}, title = {Temperature transitions of protein properties in human red blood cells. Artmann, Gerhard Michael, Kelemen, Christina; Porst, D.; B{\"u}ldt, G.; Chien, S.}, series = {Biophysical Journal. 75 (1998), H. 6}, journal = {Biophysical Journal. 75 (1998), H. 6}, isbn = {1542-0086}, pages = {3179 -- 3183}, year = {1998}, language = {en} } @article{BuniatyanAbouzarMartirosyanetal.2010, author = {Buniatyan, Vahe Vazgen and Abouzar, Maryam H. and Martirosyan, Norayr W. and Schubert, J{\"u}rgen and Gevorgian, Spartak and Sch{\"o}ning, Michael Josef and Poghossian, Arshak}, title = {pH-sensitive properties of barium strontium titanate (BST) thin films prepared by pulsed laser deposition technique}, series = {Physica Status Solidi (A)}, volume = {207}, journal = {Physica Status Solidi (A)}, number = {4}, publisher = {Wiley-VCH}, address = {Berlin}, issn = {1862-6300}, doi = {10.1002/pssa.200983310}, pages = {824 -- 830}, year = {2010}, abstract = {pH-sensitive properties of barium strontium titanate (BST) high-k thin films as alternative gate material for field-effect capacitive (bio-)chemical sensors based on an electrolyte-insulator-semiconductor system have been investigated. The BST films of different compositions (Ba0.31Sr0.69TiO3, Ba0.25Sr0.75TiO3 and Mg-doped Ba0.8Sr0.2Mg0.1Ti0.9O3) were deposited by pulsed laser deposition technique from targets fabricated by self-propagating high-temperature synthesis. The realised sensors have been electrochemically characterised by means of impedance-spectroscopy, capacitance-voltage and constant-capacitance method. The sensors possess a Nernstian-like pH sensitivity in the concentration range between pH 3 and 11 with a response time of 5-10 s. An equivalent circuit model for the BST-based capacitive field-effect sensor is discussed.}, language = {en} } @article{BuniatyanMatirosyanAbouzaretal.2009, author = {Buniatyan, Vahe Vazgen and Matirosyan, N. and Abouzar, Maryam H. and Schubert, J. and Zander, W. and Gevorgian, S. and Sch{\"o}ning, Michael Josef and Poghossian, Arshak}, title = {Capacitive field-effect pH sensor based on an electrolyte-ferroelectric-insulator-semiconductor structure}, series = {SENSOR 2009 : : 14th International Conference on Sensors, Technologies, Electronics and Applications; N{\"u}rnberg, Germany, 26 - 28 May 2009; proceedings; [part of] Sensor + Test Conference 2009 / AMA, Fachverband f{\"u}r Sensorik e.V}, journal = {SENSOR 2009 : : 14th International Conference on Sensors, Technologies, Electronics and Applications; N{\"u}rnberg, Germany, 26 - 28 May 2009; proceedings; [part of] Sensor + Test Conference 2009 / AMA, Fachverband f{\"u}r Sensorik e.V}, publisher = {AMA Service}, address = {Wunstorf}, isbn = {9783981099355}, pages = {317 -- 322}, year = {2009}, language = {en} } @article{HacklMayerWeberetal.2017, author = {Hackl, Michael and Mayer, Katharina and Weber, Mareike and Staat, Manfred and van Riet, Roger and Burkhart, Klaus Josef and M{\"u}ller, Lars-Peter and Wegmann, Kilian}, title = {Plate osteosynthesis of proximal ulna fractures : a biomechanical micromotion analysis}, series = {The journal of hand surgery}, volume = {42}, journal = {The journal of hand surgery}, number = {10}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0363-5023}, doi = {10.1016/j.jhsa.2017.05.014}, pages = {834.e1 -- 834.e7}, year = {2017}, language = {en} } @article{StaatFioriniLensaetal.1997, author = {Staat, Manfred and Fiorini, Gian Luigi and Lensa, Werner von and Burgazzi, Luciano}, title = {Reliability Methods for Passive Safety Functions}, series = {Proceedings of the SMiRT 14 Post Conference Seminar No 18 on Passive Safety Features in Nuclear Installations}, journal = {Proceedings of the SMiRT 14 Post Conference Seminar No 18 on Passive Safety Features in Nuclear Installations}, address = {Pisa}, year = {1997}, language = {en} } @article{BuniatyanHuckPoghossianetal.2013, author = {Buniatyan, Vahe Vazgen and Huck, Christina and Poghossian, Arshak and Aroutiounian, V. M. and Sch{\"o}ning, Michael Josef}, title = {BaxSr1-x TiO3/pc-Si heterojunction capacitance}, series = {Armenian journal of physics}, volume = {6}, journal = {Armenian journal of physics}, number = {4}, publisher = {National Academy of Sciences of Armenia}, address = {Yerevan}, issn = {1829-1171}, pages = {188 -- 197}, year = {2013}, language = {en} } @article{BuniatyanHuckPoghossianetal.2013, author = {Buniatyan, Vahe Vazgen and Huck, Christina and Poghossian, Arshak and Aroutiounian, V. M. and Sch{\"o}ning, Michael Josef}, title = {BaxSr1-x TiO3/pc-Si heterojunction}, series = {Armenian journal of physics}, volume = {6}, journal = {Armenian journal of physics}, number = {4}, publisher = {National Academy of Sciences of Armenia}, address = {Yerevan}, issn = {1829-1171}, pages = {177 -- 187}, year = {2013}, language = {en} } @article{BuniatyanMatirosyanAbouzaretal.2009, author = {Buniatyan, Vahe Vazgen and Matirosyan, N. W. and Abouzar, Maryam H. and Sch{\"o}ning, Michael Josef and Poghossian, Arshak and Schubert, J. and Khachatryan, V. R. and Soukiassyan, G. R.}, title = {(Ba,Sr)TiO3 based electrolyte-insulator-semiconductor pHsensors: comparitive study}, series = {Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009}, journal = {Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009}, pages = {71 -- 74}, year = {2009}, language = {en} } @article{StulpeBuschHellwig1993, author = {Stulpe, Werner and Busch, Paul and Hellwig, K.-E.}, title = {Classical Representations of Finite-Dimensional Quantum Mechanics. Busch, P.; Hellwig, K.-E.; Stulpe, W.}, series = {International Journal of Theoretical Physics. 32 (1993), H. 3}, journal = {International Journal of Theoretical Physics. 32 (1993), H. 3}, isbn = {1572-9575}, pages = {399 -- 405}, year = {1993}, language = {en} } @article{HuckPoghossianKerroumietal.2014, author = {Huck, Christina and Poghossian, Arshak and Kerroumi, Iman and Schusser, Sebastian and B{\"a}cker, Matthias and Zander, Willi and Schubert, J{\"u}rgen and Buniatyan, Vahe Vazgen and Martirosyan, Norayr W. and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Multiparameter sensor chip with Barium Strontium Titanate as multipurpose material}, series = {Electroanalysis}, volume = {26}, journal = {Electroanalysis}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1521-4109 (E-Journal); 1040-0397 (Print)}, doi = {10.1002/elan.201400076}, pages = {980 -- 987}, year = {2014}, abstract = {It is well known that biochemical and biotechnological processes are strongly dependent and affected by a variety of physico-chemical parameters such as pH value, temperature, pressure and electrolyte conductivity. Therefore, these quantities have to be monitored or controlled in order to guarantee a stable process operation, optimization and high yield. In this work, a sensor chip for the multiparameter detection of three physico-chemical parameters such as electrolyte conductivity, pH and temperature is realized using barium strontium titanate (BST) as multipurpose material. The chip integrates a capacitively coupled four-electrode electrolyte-conductivity sensor, a capacitive field-effect pH sensor and a thin-film Pt-temperature sensor. Due to the multifunctional properties of BST, it is utilized as final outermost coating layer of the processed sensor chip and serves as passivation and protection layer as well as pH-sensitive transducer material at the same time. The results of testing of the individual sensors of the developed multiparameter sensor chip are presented. In addition, a quasi-simultaneous multiparameter characterization of the sensor chip in buffer solutions with different pH value and electrolyte conductivity is performed. To study the sensor behavior and the suitability of BST as multifunctional material under harsh environmental conditions, the sensor chip was exemplarily tested in a biogas digestate.}, language = {en} } @article{HuckPoghossianBaeckeretal.2014, author = {Huck, Christina and Poghossian, Arshak and B{\"a}cker, Matthias and Chaudhuri, S. and Zander, W. and Schubert, J. and Begoyan, Vardges K. and Buniatyan, Vahe Vazgen and Wagner, P. and Sch{\"o}ning, Michael Josef}, title = {Capacitively coupled electrolyte-conductivity sensor based on high-k material of barium strontium titanate}, series = {Sensors and actuators. B: Chemical}, journal = {Sensors and actuators. B: Chemical}, number = {198}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3077 (E-Journal); 0925-4005 (Print)}, doi = {10.1016/j.snb.2014.02.103}, pages = {102 -- 109}, year = {2014}, language = {en} } @article{PoghossianWernerBuniatyanetal.2017, author = {Poghossian, Arshak and Werner, Frederik and Buniatyan, Vahe Vazgen and Wagner, Torsten and Miamoto, K. and Yoshinobu, T. and Sch{\"o}ning, Michael Josef}, title = {Towards addressability of light-addressable potentiometric sensors: Shunting effect of non-illuminated region and cross-talk}, series = {Sensor and Actuators B: Chemical}, journal = {Sensor and Actuators B: Chemical}, number = {244}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2017.01.047}, pages = {1071 -- 1079}, year = {2017}, abstract = {The LAPS (light-addressable potentiometric sensor) platform is one of the most attractive approaches for chemical and biological sensing with many applications ranging from pH and ion/analyte concentration measurements up to cell metabolism detection and chemical imaging. However, although it is generally accepted that LAPS measurements are spatially resolved, the light-addressability feature of LAPS devices has not been discussed in detail so far. In this work, an extended electrical equivalent-circuit model of the LAPS has been presented, which takes into account possible cross-talk effects due to the capacitive coupling of the non-illuminated region. A shunting effect of the non-illuminated area on the measured photocurrent and addressability of LAPS devices has been studied. It has been shown, that the measured photocurrent will be determined not only by the local interfacial potential in the illuminated region but also by possible interfacial potential changes in the non-illuminated region, yielding cross-talk effects. These findings were supported by the experimental investigations of a penicillin-sensitive multi-spot LAPS and a metal-insulator-semiconductor LAPS as model systems.}, language = {en} } @article{HuckPoghossianBaeckeretal.2014, author = {Huck, Christina and Poghossian, Arshak and B{\"a}cker, Matthias and Reisert, Steffen and Schubert, J. and Zander, W. and Begoyan, Vardges K. and Buniatyan, Vahe Vazgen and Sch{\"o}ning, Michael Josef}, title = {Chemical sensors based on a high-k perovskite oxide of barium strontium titanate}, series = {Procedia Engineering}, volume = {87}, journal = {Procedia Engineering}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2014.11.258}, pages = {28 -- 31}, year = {2014}, abstract = {High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors for liquids. In this work, BST films have been applied as a sensitive transducer material for a label-free detection of adsorbed charged macromolecules (positively charged polyelectrolytes) and concentration of hydrogen peroxide vapor as well as protection insulator layer for a contactless electrolyte-conductivity sensor. The experimental results of characterization of individual sensors are presented. Special emphasis is devoted towards the development of a capacitively-coupled contactless electrolyte-conductivity sensor.}, language = {en} } @article{HuckPoghossianBaeckeretal.2015, author = {Huck, Christina and Poghossian, Arshak and B{\"a}cker, Matthias and Reisert, Steffen and Kramer, Friederike and Begoyan, Vardges K. and Buniatyan, Vahe Vazgen and Sch{\"o}ning, Michael Josef}, title = {Multi-parameter sensing using high-k oxide of barium strontium titanate}, series = {Physica status solidi (a)}, volume = {212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431911}, pages = {1259}, year = {2015}, abstract = {High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors. In this work, a Si-based sensor chip containing Pt interdigitated electrodes covered with a thin BST layer (485 nm) has been developed for multi-parameter chemical sensing. The chip has been applied for the contactless measurement of the electrolyte conductivity, the detection of adsorbed charged macromolecules (positively charged polyelectrolytes of polyethylenimine) and the concentration of hydrogen peroxide (H2O2) vapor. The experimental results of functional testing of individual sensors are presented. The mechanism of the BST sensitivity to charged polyelectrolytes and H2O2 vapor has been proposed and discussed.}, language = {en} } @inproceedings{BuniatyanHuckPoghossianetal.2014, author = {Buniatyan, Vahe Vazgen and Huck, Christina and Poghossian, Arshak and Sch{\"o}ning, Michael Josef and Rustamyan, L. G. and Hovnikyan, H. H.}, title = {Equivalent circuit and optimization of impedance characteristics of an electrolyte conductivity sensor}, series = {Proceedings of State Engineering University Armenia : Series Information technologies, electronics, radio engineering}, volume = {Iss. 17}, booktitle = {Proceedings of State Engineering University Armenia : Series Information technologies, electronics, radio engineering}, number = {No. 1}, pages = {69 -- 76}, year = {2014}, language = {en} } @inproceedings{HuckPoghossianBuniatyanetal.2014, author = {Huck, Christina and Poghossian, Arshak and Buniatyan, Vahe Vazgen and Sch{\"o}ning, Michael Josef and Wagner, Patrick}, title = {Multi-parameter detection for supporting monitoring and control of biogas processes in agriculture}, series = {Sensoren und Messsysteme 2014 ; Beitr{\"a}ge der 17. GMA/ITG-Fachtagung vom 3. bis 4. Juni 2014 in N{\"u}rnberg. (ITG-Fachbericht ; 250)}, booktitle = {Sensoren und Messsysteme 2014 ; Beitr{\"a}ge der 17. GMA/ITG-Fachtagung vom 3. bis 4. Juni 2014 in N{\"u}rnberg. (ITG-Fachbericht ; 250)}, publisher = {VDE-Verl.}, address = {Berlin}, organization = {VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik}, isbn = {978-3-8007-3622-5}, pages = {1 -- 5}, year = {2014}, language = {en} } @article{WagnerMolinaBisellietal.2007, author = {Wagner, Torsten and Molina, R. and Biselli, Manfred and Canzoneri, Michelangelo and Schnitzler, Thomas and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {A light-addressable potentiometric sensor system for fast, simultaneous and spatial detection of the metabolic activity of biological cells}, series = {Transducers '07 Eurosensors XXI : digest of technical papers ; the14th International Conference on Solid-State Sensors, Actuators and Microsystems, June 10-14, 2007, Lyon, France / Gilles Delapierre (Ed.)}, journal = {Transducers '07 Eurosensors XXI : digest of technical papers ; the14th International Conference on Solid-State Sensors, Actuators and Microsystems, June 10-14, 2007, Lyon, France / Gilles Delapierre (Ed.)}, publisher = {IEEE}, address = {Piscataway}, isbn = {1-4244-0841-5}, pages = {1107 -- 1110}, year = {2007}, language = {en} } @article{WagnerMolinaYoshinobuetal.2007, author = {Wagner, Torsten and Molina, Roberto and Yoshinobu, Tatsuo and Kloock, Joachim P. and Biselli, Manfred and Canzoneri, Michelangelo and Schnitzler, Thomas and Sch{\"o}ning, Michael Josef}, title = {Handheld multi-channel LAPS device as a transducer platform for possible biological and chemical multi-sensor applications}, series = {Electrochimica Acta. 53 (2007), H. 2}, journal = {Electrochimica Acta. 53 (2007), H. 2}, isbn = {0013-4686}, pages = {305 -- 311}, year = {2007}, language = {en} } @article{TemizArtmannCavdarYeniceriogluetal.2003, author = {Temiz Artmann, Ayseg{\"u}l and Cavdar, Caner and Yenicerioglu, Yavuz and Caliskan, Sezer and Celik, Ali and Aykut, Sifil and Onvural, Banu and Camsari, Taner}, title = {The effects of intravenous iron treatment on oxidant stress and erythrocyte deformability in haemodialysis patients. Cavdar, C.; Temiz, A.; Yenicerioglu, Y.; Caliskan, S.; Celik, A.; Sifil, A.; Onvural, B.; Camsari, T.}, series = {Scandinavian Journal of Urology and Nephrology. 37 (2003), H. 1}, journal = {Scandinavian Journal of Urology and Nephrology. 37 (2003), H. 1}, isbn = {0036-5599}, pages = {77 -- 82}, year = {2003}, language = {en} }