@inproceedings{ViehmannLimpertHofmannetal.2023, author = {Viehmann, Tarik and Limpert, Nicolas and Hofmann, Till and Henning, Mike and Ferrein, Alexander and Lakemeyer, Gerhard}, title = {Winning the RoboCup logistics league with visual servoing and centralized goal reasoning}, series = {RoboCup 2022}, booktitle = {RoboCup 2022}, editor = {Eguchi, Amy and Lau, Nuno and Paetzel-Pr{\"u}smann, Maike and Wanichanon, Thanapat}, publisher = {Springer}, address = {Cham}, isbn = {978-3-031-28468-7 (Print)}, doi = {https://doi.org/10.1007/978-3-031-28469-4_25}, pages = {300 -- 312}, year = {2023}, abstract = {The RoboCup Logistics League (RCLL) is a robotics competition in a production logistics scenario in the context of a Smart Factory. In the competition, a team of three robots needs to assemble products to fulfill various orders that are requested online during the game. This year, the Carologistics team was able to win the competition with a new approach to multi-agent coordination as well as significant changes to the robot's perception unit and a pragmatic network setup using the cellular network instead of WiFi. In this paper, we describe the major components of our approach with a focus on the changes compared to the last physical competition in 2019.}, language = {en} } @inproceedings{NeugebauerBrutschyMeyeretal.2014, author = {Neugebauer, Georg and Brutschy, Lucas and Meyer, Ulrike and Wetzel, Susanne}, title = {Privacy-preserving multi-party reconciliation secure in the malicious model}, series = {DPM 2013, SETOP 2013: Data Privacy Management and Autonomous Spontaneous Security}, booktitle = {DPM 2013, SETOP 2013: Data Privacy Management and Autonomous Spontaneous Security}, editor = {Garcia-Alfaro, Joaquin and Lioudakis, Georgios and Cuppens-Boulahia, Nora and Foley, Simon and Fitzgerald, William M.}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-642-54567-2 (Print)}, doi = {10.1007/978-3-642-54568-9_12}, pages = {178 -- 193}, year = {2014}, abstract = {The problem of fair and privacy-preserving ordered set reconciliation arises in a variety of applications like auctions, e-voting, and appointment reconciliation. While several multi-party protocols have been proposed that solve this problem in the semi-honest model, there are no multi-party protocols that are secure in the malicious model so far. In this paper, we close this gap. Our newly proposed protocols are shown to be secure in the malicious model based on a variety of novel non-interactive zero-knowledge-proofs. We describe the implementation of our protocols and evaluate their performance in comparison to protocols solving the problem in the semi-honest case.}, language = {en} } @inproceedings{SchulteTiggesMatheisRekeetal.2023, author = {Schulte-Tigges, Joschua and Matheis, Dominik and Reke, Michael and Walter, Thomas and Kaszner, Daniel}, title = {Demonstrating a V2X enabled system for transition of control and minimum risk manoeuvre when leaving the operational design domain}, series = {HCII 2023: HCI in Mobility, Transport, and Automotive Systems}, booktitle = {HCII 2023: HCI in Mobility, Transport, and Automotive Systems}, editor = {Kr{\"o}mker, Heidi}, publisher = {Springer}, address = {Cham}, isbn = {978-3-031-35677-3 (Print)}, doi = {10.1007/978-3-031-35678-0_12}, pages = {200 -- 210}, year = {2023}, abstract = {Modern implementations of driver assistance systems are evolving from a pure driver assistance to a independently acting automation system. Still these systems are not covering the full vehicle usage range, also called operational design domain, which require the human driver as fall-back mechanism. Transition of control and potential minimum risk manoeuvres are currently research topics and will bridge the gap until full autonomous vehicles are available. The authors showed in a demonstration that the transition of control mechanisms can be further improved by usage of communication technology. Receiving the incident type and position information by usage of standardised vehicle to everything (V2X) messages can improve the driver safety and comfort level. The connected and automated vehicle's software framework can take this information to plan areas where the driver should take back control by initiating a transition of control which can be followed by a minimum risk manoeuvre in case of an unresponsive driver. This transition of control has been implemented in a test vehicle and was presented to the public during the IEEE IV2022 (IEEE Intelligent Vehicle Symposium) in Aachen, Germany.}, language = {en} } @inproceedings{GaldiHartungDugelay2017, author = {Galdi, Chiara and Hartung, Frank and Dugelay, Jean-Luc}, title = {Videos versus still images: Asymmetric sensor pattern noise comparison on mobile phones}, series = {Electronic Imaging}, booktitle = {Electronic Imaging}, publisher = {Society for Imaging Science and Technology}, address = {Springfield, Virginia}, issn = {2470-1173}, doi = {10.2352/ISSN.2470-1173.2017.7.MWSF-331}, pages = {100 -- 103}, year = {2017}, abstract = {Nowadays, the most employed devices for recoding videos or capturing images are undoubtedly the smartphones. Our work investigates the application of source camera identification on mobile phones. We present a dataset entirely collected by mobile phones. The dataset contains both still images and videos collected by 67 different smartphones. Part of the images consists in photos of uniform backgrounds, especially collected for the computation of the RSPN. Identifying the source camera given a video is particularly challenging due to the strong video compression. The experiments reported in this paper, show the large variation in performance when testing an highly accurate technique on still images and videos.}, language = {en} } @inproceedings{KueppersSchubaNeugebaueretal.2023, author = {K{\"u}ppers, Malte and Schuba, Marko and Neugebauer, Georg and H{\"o}ner, Tim and Hack, Sacha}, title = {Security analysis of the KNX smart building protocol}, series = {ARES '23: Proceedings of the 18th International Conference on Availability, Reliability and Security}, booktitle = {ARES '23: Proceedings of the 18th International Conference on Availability, Reliability and Security}, publisher = {ACM}, doi = {10.1145/3600160.3605167}, pages = {1 -- 7}, year = {2023}, abstract = {KNX is a protocol for smart building automation, e.g., for automated heating, air conditioning, or lighting. This paper analyses and evaluates state-of-the-art KNX devices from manufacturers Merten, Gira and Siemens with respect to security. On the one hand, it is investigated if publicly known vulnerabilities like insecure storage of passwords in software, unencrypted communication, or denialof-service attacks, can be reproduced in new devices. On the other hand, the security is analyzed in general, leading to the discovery of a previously unknown and high risk vulnerability related to so-called BCU (authentication) keys.}, language = {en} } @inproceedings{AlhaskirTschescheLinkeetal.2023, author = {Alhaskir, Mohamed and Tschesche, Matteo and Linke, Florian and Schriewer, Elisabeth and Weber, Yvonne and Wolking, Stefan and R{\"o}hrig, Rainer and Koch, Henner and Kutafina, Ekaterina}, title = {ECG matching: an approach to synchronize ECG datasets for data quality comparisons}, series = {German Medical Data Sciences 2023 - Science. Close to People.}, volume = {307}, booktitle = {German Medical Data Sciences 2023 - Science. Close to People.}, editor = {R{\"o}hrig, Rainer and Grabe, Niels and Haag, Martin and H{\"u}bner, Ursula and Sax, Ulrich and Schmidt, Carsten Oliver and Sedlmayr, Martin and Zapf, Antonia}, publisher = {IOS Press}, isbn = {978-1-64368-428-4 (Print)}, doi = {10.3233/SHTI230718}, pages = {225 -- 232}, year = {2023}, abstract = {Clinical assessment of newly developed sensors is important for ensuring their validity. Comparing recordings of emerging electrocardiography (ECG) systems to a reference ECG system requires accurate synchronization of data from both devices. Current methods can be inefficient and prone to errors. To address this issue, three algorithms are presented to synchronize two ECG time series from different recording systems: Binned R-peak Correlation, R-R Interval Correlation, and Average R-peak Distance. These algorithms reduce ECG data to their cyclic features, mitigating inefficiencies and minimizing discrepancies between different recording systems. We evaluate the performance of these algorithms using high-quality data and then assess their robustness after manipulating the R-peaks. Our results show that R-R Interval Correlation was the most efficient, whereas the Average R-peak Distance and Binned R-peak Correlation were more robust against noisy data.}, language = {en} } @article{KowalewskiBragardHueningetal.2023, author = {Kowalewski, Paul and Bragard, Michael and H{\"u}ning, Felix and De Doncker, Rik W.}, title = {An inexpensive Wiegand-sensor-based rotary encoder without rotating magnets for use in electrical drives}, series = {IEEE Transactions on Instrumentation and Measurement}, journal = {IEEE Transactions on Instrumentation and Measurement}, publisher = {IEEE}, issn = {0018-9456 (Print)}, doi = {10.1109/TIM.2023.3326166}, pages = {10 Seiten}, year = {2023}, abstract = {This paper introduces an inexpensive Wiegand-sensor-based rotary encoder that avoids rotating magnets and is suitable for electrical-drive applications. So far, Wiegand-sensor-based encoders usually include a magnetic pole wheel with rotating permanent magnets. These encoders combine the disadvantages of an increased magnet demand and a limited maximal speed due to the centripetal force acting on the rotating magnets. The proposed approach reduces the total demand of permanent magnets drastically. Moreover, the rotating part is manufacturable from a single piece of steel, which makes it very robust and cheap. This work presents the theoretical operating principle of the proposed approach and validates its benefits on a hardware prototype. The presented proof-of-concept prototype achieves a mechanical resolution of 4.5 ° by using only 4 permanent magnets, 2Wiegand sensors and a rotating steel gear wheel with 20 teeth.}, language = {en} } @inproceedings{SteuerDankert2023, author = {Steuer-Dankert, Linda}, title = {A crazy little thing called sustainability}, series = {51st Annual Conference of the European Society for Engineering Education (SEFI)}, booktitle = {51st Annual Conference of the European Society for Engineering Education (SEFI)}, doi = {10.21427/9CQR-VC94}, pages = {11 Seiten}, year = {2023}, abstract = {Achieving the 17 Sustainable Development Goals (SDGs) set by the United Nations (UN) in 2015 requires global collaboration between different stakeholders. Industry, and in particular engineers who shape industrial developments, have a special role to play as they are confronted with the responsibility to holistically reflect sustainability in industrial processes. This means that, in addition to the technical specifications, engineers must also question the effects of their own actions on an ecological, economic and social level in order to ensure sustainable action and contribute to the achievement of the SDGs. However, this requires competencies that enable engineers to apply all three pillars of sustainability to their own field of activity and to understand the global impact of industrial processes. In this context, it is relevant to understand how industry already reflects sustainability and to identify competences needed for sustainable development.}, language = {en} } @inproceedings{HueningMund2023, author = {H{\"u}ning, Felix and Mund, Cindy}, title = {Integration of agile development in standard labs}, series = {51st Annual Conference of the European Society for Engineering Education (SEFI)}, booktitle = {51st Annual Conference of the European Society for Engineering Education (SEFI)}, doi = {10.21427/NK4Z-WS73}, pages = {11 Seiten}, year = {2023}, abstract = {In addition to the technical content, modern courses at university should also teach professional skills to enhance the competencies of students towards their future work. The competency driven approach including technical as well as professional skills makes it necessary to find a suitable way for the integration into the corresponding module in a scalable and flexible manner. Agile development, for example, is essential for the development of modern systems and applications and makes use of dedicated professional skills of the team members, like structured group dynamics and communication, to enable the fast and reliable development. This paper presents an easy to integrate and flexible approach to integrate Scrum, an agile development method, into the lab of an existing module. Due to the different role models of Scrum the students have an individual learning success, gain valuable insight into modern system development and strengthen their communication and organization skills. The approach is implemented and evaluated in the module Vehicle Systems, but it can be transferred easily to other technical courses as well. The evaluation of the implementation considers feedback of all stakeholders, students, supervisor and lecturers, and monitors the observations during project lifetime.}, language = {en} } @article{KraffBitzDammannetal.2010, author = {Kraff, Oliver and Bitz, Andreas and Dammann, Philipp and Ladd, Susanne C. and Ladd, Mark E. and Quick, Harald H.}, title = {An eight-channel transmit/receive multipurpose coil for musculoskeletal MR imaging at 7 T}, series = {Medical Physics}, volume = {37}, journal = {Medical Physics}, number = {12}, publisher = {Wiley}, address = {Hoboken, NJ}, issn = {2473-4209}, doi = {10.1118/1.3517176}, pages = {6368 -- 6376}, year = {2010}, abstract = {Purpose: MRI plays a leading diagnostic role in assessing the musculoskeletal (MSK) system and is well established for most questions at clinically used field strengths (up to 3 T). However, there are still limitations in imaging early stages of cartilage degeneration, very fine tendons and ligaments, or in locating nerve lesions, for example. 7 T MRI of the knee has already received increasing attention in the current published literature, but there is a strong need to develop new radiofrequency (RF) coils to assess more regions of the MSK system. In this work, an eight-channel transmit/receive RF array was built as a multipurpose coil for imaging some of the thus far neglected regions. An extensive coil characterization protocol and first in vivo results of the human wrist, shoulder, elbow, knee, and ankle imaged at 7 T will be presented. Methods: Eight surface loop coils with a dimension ofurn:x-wiley:00942405:media:mp7176:mp7176-math-0001 were machined from FR4 circuit board material. To facilitate easy positioning, two coil clusters, each with four loop elements, were combined to one RF transmit/receive array. An overlapped and shifted arrangement of the coil elements was chosen to reduce the mutual inductance between neighboring coils. A phantom made of body-simulating liquid was used for tuning and matching on the bench. Afterward, the S-parameters were verified on a human wrist, elbow, and shoulder. For safety validation, a detailed compliance test was performed including full wave simulations of the RF field distribution and the corresponding specific absorption rate (SAR) for all joints. In vivo images of four volunteers were assessed with gradient echo and spin echo sequences modified to obtain optimal image contrast, full anatomic coverage, and the highest spatial resolution within a reasonable acquisition time. The performance of the RF coil was additionally evaluated by in vivo B1 mapping. Results: A comparison of B1 per unit power, flip angle distribution, and anatomic images showed a fairly homogeneous excitation for the smaller joints (elbow, wrist, and ankle), while for the larger joints, the shoulder and especially the knee, B1 inhomogeneities and limited penetration depth were more pronounced. However, the greater part of the shoulder joint could be imaged.In vivo images rendered very fine anatomic details such as fascicles of the median nerve and the branching of the nerve bundles. High-resolution images of cartilage, labrum, and tendons could be acquired. Additionally, turbo spin echo (TSE) and inversion recovery sequences performed very well. Conclusions: This study demonstrates that the concept of two four-channel transmit/receive RF arrays can be used as a multipurpose coil for high-resolutionin vivo MR imaging of the musculoskeletal system at 7 T. Not only gradient echo but also typical clinical and SAR-intensive sequences such as STIR and TSE performed well. Imaging of small structures and peripheral nerves could in particular benefit from this technique.}, language = {en} } @article{SchlamannYoonMaderwaldetal.2010, author = {Schlamann, Marc and Yoon, Min-Suk and Maderwald, Stefan and Pietrzyk, Thomas and Bitz, Andreas and Gerwig, Marcus and Forsting, Michael and Ladd, Susanne C. and Ladd, Mark E. and Kastrup, Oliver}, title = {Short term effects of magnetic resonance imaging on excitability of the motor cortex at 1.5T and 7T}, series = {Academic Radiology}, volume = {17}, journal = {Academic Radiology}, number = {3}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1076-6332}, doi = {10.1016/j.acra.2009.10.004}, pages = {277 -- 281}, year = {2010}, abstract = {Rationale and Objectives The increasing spread of high-field and ultra-high-field magnetic resonance imaging (MRI) scanners has encouraged new discussion of the safety aspects of MRI. Few studies have been published on possible cognitive effects of MRI examinations. The aim of this study was to examine whether changes are measurable after MRI examinations at 1.5 and 7 T by means of transcranial magnetic stimulation (TMS). Materials and Methods TMS was performed in 12 healthy, right-handed male volunteers. First the individual motor threshold was specified, and then the cortical silent period (SP) was measured. Subsequently, the volunteers were exposed to the 1.5-T MRI scanner for 63 minutes using standard sequences. The MRI examination was immediately followed by another TMS session. Fifteen minutes later, TMS was repeated. Four weeks later, the complete setting was repeated using a 7-T scanner. Control conditions included lying in the 1.5-T scanner for 63 minutes without scanning and lying in a separate room for 63 minutes. TMS was performed in the same way in each case. For statistical analysis, Wilcoxon's rank test was performed. Results Immediately after MRI exposure, the SP was highly significantly prolonged in all 12 subjects at 1.5 and 7 T. The motor threshold was significantly increased. Fifteen minutes after the examination, the measured value tended toward normal again. Control conditions revealed no significant differences. Conclusion MRI examinations lead to a transient and highly significant alteration in cortical excitability. This effect does not seem to depend on the strength of the static magnetic field.}, language = {en} } @article{SchlamannVoigtMaderwaldetal.2010, author = {Schlamann, Marc and Voigt, Melanie A. and Maderwald, Stefan and Bitz, Andreas and Kraff, Oliver and Ladd, Susanne C. and Ladd, Mark E. and Forsting, Michael and Wilhelm, Hans}, title = {Exposure to high-field MRI does not affect cognitive function}, series = {Journal of Magnetic Resonance Imaging}, volume = {31}, journal = {Journal of Magnetic Resonance Imaging}, number = {5}, publisher = {Wiley-Liss}, address = {New York}, issn = {1522-2586}, doi = {10.1002/jmri.22065}, pages = {1061 -- 1066}, year = {2010}, abstract = {Purpose To assess potential cognitive deficits under the influence of static magnetic fields at various field strengths some studies already exist. These studies were not focused on attention as the most vulnerable cognitive function. Additionally, mostly no magnetic resonance imaging (MRI) sequences were performed. Materials and Methods In all, 25 right-handed men were enrolled in this study. All subjects underwent one MRI examination of 63 minutes at 1.5 T and one at 7 T within an interval of 10 to 30 days. The order of the examinations was randomized. Subjects were referred to six standardized neuropsychological tests strictly focused on attention immediately before and after each MRI examination. Differences in neuropsychological variables between the timepoints before and after each MRI examination were assessed and P-values were calculated Results Only six subtests revealed significant differences between pre- and post-MRI. In these tests the subjects achieved better results in post-MRI testing than in pre-MRI testing (P = 0.013-0.032). The other tests revealed no significant results. Conclusion The improvement in post-MRI testing is only explicable as a result of learning effects. MRI examinations, even in ultrahigh-field scanners, do not seem to have any persisting influence on the attention networks of human cognition immediately after exposure.}, language = {en} } @article{OrzadaMaderwaldPoseretal.2010, author = {Orzada, Stephan and Maderwald, Stefan and Poser, Benedikt Andreas and Bitz, Andreas and Quick, Harald H. and Ladd, Mark E.}, title = {RF excitation using time interleaved acquisition of modes (TIAMO) to address B1 inhomogeneity in high-field MRI}, series = {Magnetic Resonance in Medicine}, volume = {64}, journal = {Magnetic Resonance in Medicine}, number = {2}, publisher = {Wiley-Liss}, address = {New York}, issn = {1522-2594}, doi = {10.1002/mrm.22527}, pages = {327 -- 333}, year = {2010}, abstract = {As the field strength and, therefore, the operational frequency in MRI is increased, the wavelength approaches the size of the human head/body, resulting in wave effects, which cause signal decreases and dropouts. Several multichannel approaches have been proposed to try to tackle these problems, including RF shimming, where each element in an array is driven by its own amplifier and modulated with a certain (constant) amplitude and phase relative to the other elements, and Transmit SENSE, where spatially tailored RF pulses are used. In this article, a relatively inexpensive and easy to use imaging scheme for 7 Tesla imaging is proposed to mitigate signal voids due to B1 field inhomogeneity. Two time-interleaved images are acquired using a different excitation mode for each. By forming virtual receive elements, both images are reconstructed together using GRAPPA to achieve a more homogeneous image, with only small SNR and SAR penalty in head and body imaging at 7 Tesla.}, language = {en} } @inproceedings{AltherrConzenElsenetal.2023, author = {Altherr, Lena and Conzen, Max and Elsen, Ingo and Frauenrath, Tobias and Lyrmann, Andreas}, title = {Sensor retrofitting of existing buildings in an interdisciplinary teaching project at university level}, series = {Tagungsband AALE 2023 : mit Automatisierung gegen den Klimawandel}, booktitle = {Tagungsband AALE 2023 : mit Automatisierung gegen den Klimawandel}, editor = {Reiff-Stephan, J{\"o}rg and J{\"a}kel, Jens and Schwarz, Andr{\´e}}, publisher = {le-tex publishing services GmbH}, address = {Leipzig}, isbn = {978-3-910103-01-6}, doi = {10.33968/2023.04}, pages = {31 -- 40}, year = {2023}, abstract = {Existing residential buildings have an average lifetime of 100 years. Many of these buildings will exist for at least another 50 years. To increase the efficiency of these buildings while keeping costs at reasonable rates, they can be retrofitted with sensors that deliver information to central control units for heating, ventilation and electricity. This retrofitting process should happen with minimal intervention into existing infrastructure and requires new approaches for sensor design and data transmission. At FH Aachen University of Applied Sciences, students of different disciplines work together to learn how to design, build, deploy and operate such sensors. The presented teaching project already created a low power design for a combined CO2, temperature and humidity measurement device that can be easily integrated into most home automation systems}, language = {en} } @article{SchoppRohrbachLangeretal.2024, author = {Schopp, Christoph and Rohrbach, Felix and Langer, Luc and Heuermann, Holger}, title = {Detection of welding wire length by active S11 measurement}, series = {IEEE Transactions on Plasma Science}, journal = {IEEE Transactions on Plasma Science}, number = {Early Access}, publisher = {IEEE}, issn = {0093-3813 (Print)}, doi = {10.1109/TPS.2024.3356659}, pages = {1 -- 6}, year = {2024}, abstract = {A novel method to determine the extruded length of a metallic wire for a directed energy deposition (DED) process using a microwave (MW) plasma jet with a straight-through wire feed is presented. The method is based on the relative comparison of the measured frequency response obtained by the large-signal scattering parameter (Hot-S) technique. In the practical working range, repeatability of less than 6\% for a nonactive plasma and 9\% for the active plasma state is found. Measurements are conducted with a focus on a simple solution to decrease the processing time and reduce the integration time of the process into the existing hardware. It is shown that monitoring a single frequency for magnitude and phase changes is sufficient to achieve good accuracy. A combination of different measurement values to determine the length is possible. The applicability to different diameter of the same material is shown as well as a contact detection of the wire and metallic substrate.}, language = {en} } @inproceedings{ArndtConzenElsenetal.2023, author = {Arndt, Tobias and Conzen, Max and Elsen, Ingo and Ferrein, Alexander and Galla, Oskar and K{\"o}se, Hakan and Schiffer, Stefan and Tschesche, Matteo}, title = {Anomaly detection in the metal-textile industry for the reduction of the cognitive load of quality control workers}, series = {PETRA '23: Proceedings of the 16th International Conference on PErvasive Technologies Related to Assistive Environments}, booktitle = {PETRA '23: Proceedings of the 16th International Conference on PErvasive Technologies Related to Assistive Environments}, publisher = {ACM}, isbn = {9798400700699}, doi = {10.1145/3594806.3596558}, pages = {535 -- 542}, year = {2023}, abstract = {This paper presents an approach for reducing the cognitive load for humans working in quality control (QC) for production processes that adhere to the 6σ -methodology. While 100\% QC requires every part to be inspected, this task can be reduced when a human-in-the-loop QC process gets supported by an anomaly detection system that only presents those parts for manual inspection that have a significant likelihood of being defective. This approach shows good results when applied to image-based QC for metal textile products.}, language = {en} } @article{TurdumamatovBeldaHeuermann2024, author = {Turdumamatov, Samat and Belda, Aljoscha and Heuermann, Holger}, title = {Shaping a decoupled atmospheric pressure microwave plasma with antenna structures, Maxwell's equations, and boundary conditions}, series = {IEEE Transactions on Plasma Science}, journal = {IEEE Transactions on Plasma Science}, number = {Early Access}, publisher = {IEEE}, issn = {0093-3813 (Print)}, doi = {10.1109/TPS.2024.3383589}, pages = {1 -- 9}, year = {2024}, abstract = {This article addresses the need for an innovative technique in plasma shaping, utilizing antenna structures, Maxwell's laws, and boundary conditions within a shielded environment. The motivation lies in exploring a novel approach to efficiently generate high-energy density plasma with potential applications across various fields. Implemented in an E01 circular cavity resonator, the proposed method involves the use of an impedance and field matching device with a coaxial connector and a specially optimized monopole antenna. This setup feeds a low-loss cavity resonator, resulting in a high-energy density air plasma with a surface temperature exceeding 3500 o C, achieved with a minimal power input of 80 W. The argon plasma, resembling the shape of a simple monopole antenna with modeled complex dielectric values, offers a more energy-efficient alternative compared to traditional, power-intensive plasma shaping methods. Simulations using a commercial electromagnetic (EM) solver validate the design's effectiveness, while experimental validation underscores the method's feasibility and practical implementation. Analyzing various parameters in an argon atmosphere, including hot S -parameters and plasma beam images, the results demonstrate the successful application of this technique, suggesting its potential in coating, furnace technology, fusion, and spectroscopy applications.}, language = {en} } @article{BragardSoltauThomasetal.2010, author = {Bragard, Michael and Soltau, N. and Thomas, S. and De Doncker, R. W.}, title = {The balance of renewable sources and user demands in grids : power electronics for modular battery energy storage systems}, series = {IEEE transactions on power electronics}, volume = {25}, journal = {IEEE transactions on power electronics}, number = {12}, publisher = {IEEE}, address = {New York}, issn = {0885-8993}, doi = {10.1109/TPEL.2010.2085455}, pages = {3049 -- 3056}, year = {2010}, abstract = {The continuously growing amount of renewable sources starts compromising the stability of electrical grids. Contradictory to fossil fuel power plants, energy production of wind and photovoltaic (PV) energy is fluctuating. Although predictions have significantly improved, an outage of multi-MW offshore wind farms poses a challenging problem. One solution could be the integration of storage systems in the grid. After a short overview, this paper focuses on two exemplary battery storage systems, including the required power electronics. The grid integration, as well as the optimal usage of volatile energy reserves, is presented for a 5- kW PV system for home application, as well as for a 100- MW medium-voltage system, intended for wind farm usage. The efficiency and cost of topologies are investigated as a key parameter for large-scale integration of renewable power at medium- and low-voltage.}, language = {en} } @article{FerreinNiemuellerSteinbauer2010, author = {Ferrein, Alexander and Niem{\"u}ller, Tim and Steinbauer, Gerald}, title = {Team Zadeat 2010 : application for participation}, pages = {5 Seiten}, year = {2010}, language = {en} } @article{ProchnowGebingLadageetal.2011, author = {Prochnow, Nora and Gebing, Tina and Ladage, Kerstin and Krause-Finkeldey, Dorothee and Ourdi, Abessamad El and Bitz, Andreas and Streckert, Joachim and Hansen, Volkert and Dermietzel, Rolf}, title = {Electromagnetic field effect or simply stress? Effects of UMTS exposure on hippocampal longterm plasticity in the context of procedure related hormone release}, series = {PLoS one}, volume = {6}, journal = {PLoS one}, number = {5}, publisher = {PLOS}, address = {San Francisco}, doi = {10.1371/journal.pone.0019437}, pages = {e19437}, year = {2011}, abstract = {Harmful effects of electromagnetic fields (EMF) on cognitive and behavioural features of humans and rodents have been controversially discussed and raised persistent concern about adverse effects of EMF on general brain functions. In the present study we applied radio-frequency (RF) signals of the Universal Mobile Telecommunications System (UMTS) to full brain exposed male Wistar rats in order to elaborate putative influences on stress hormone release (corticosteron; CORT and adrenocorticotropic hormone; ACTH) and on hippocampal derived synaptic long-term plasticity (LTP) and depression (LTD) as electrophysiological hallmarks for memory storage and memory consolidation. Exposure was computer controlled providing blind conditions. Nominal brain-averaged specific absorption rates (SAR) as a measure of applied mass-related dissipated RF power were 0, 2, and 10 W/kg over a period of 120 min. Comparison of cage exposed animals revealed, regardless of EMF exposure, significantly increased CORT and ACTH levels which corresponded with generally decreased field potential slopes and amplitudes in hippocampal LTP and LTD. Animals following SAR exposure of 2 W/kg (averaged over the whole brain of 2.3 g tissue mass) did not differ from the sham-exposed group in LTP and LTD experiments. In contrast, a significant reduction in LTP and LTD was observed at the high power rate of SAR (10 W/kg). The results demonstrate that a rate of 2 W/kg displays no adverse impact on LTP and LTD, while 10 W/kg leads to significant effects on the electrophysiological parameters, which can be clearly distinguished from the stress derived background. Our findings suggest that UMTS exposure with SAR in the range of 2 W/kg is not harmful to critical markers for memory storage and memory consolidation, however, an influence of UMTS at high energy absorption rates (10 W/kg) cannot be excluded.}, language = {en} } @article{TheysohnKraffEilersetal.2014, author = {Theysohn, Jens M. and Kraff, Oliver and Eilers, Kristina and Andrade, Dorian and Gerwig, Marcus and Timmann, Dagmar and Schmitt, Franz and Ladd, Mark E. and Ladd, Susanne C. and Bitz, Andreas}, title = {Vestibular effects of a 7 Tesla MRI examination compared to 1.5 T and 0 T in healthy volunteers}, series = {PLoS one}, volume = {9}, journal = {PLoS one}, number = {3}, publisher = {PLOS}, address = {San Francisco}, issn = {1932-6203}, doi = {10.1371/journal.pone.0092104}, pages = {e92104}, year = {2014}, abstract = {Ultra-high-field MRI (7 Tesla (T) and above) elicits more temporary side-effects compared to 1.5 T and 3 T, e.g. dizziness or "postural instability" even after exiting the scanner. The current study aims to assess quantitatively vestibular performance before and after exposure to different MRI scenarios at 7 T, 1.5 T and 0 T. Sway path and body axis rotation (Unterberger's stepping test) were quantitatively recorded in a total of 46 volunteers before, 2 minutes after, and 15 minutes after different exposure scenarios: 7 T head MRI (n = 27), 7 T no RF (n = 22), 7 T only B₀ (n = 20), 7 T in \& out B₀ (n = 20), 1.5 T no RF (n = 20), 0 T (n = 15). All exposure scenarios lasted 30 minutes except for brief one minute exposure in 7 T in \& out B₀. Both measures were documented utilizing a 3D ultrasound system. During sway path evaluation, the experiment was repeated with eyes both open and closed. Sway paths for all long-lasting 7 T scenarios (normal, no RF, only B₀) with eyes closed were significantly prolonged 2 minutes after exiting the scanner, normalizing after 15 minutes. Brief exposure to 7 T B₀ or 30 minutes exposure to 1.5 T or 0 T did not show significant changes. End positions after Unterberger's stepping test were significantly changed counter-clockwise after all 7 T scenarios, including the brief in \& out B₀ exposure. Shorter exposure resulted in a smaller alteration angle. In contrast to sway path, reversal of changes in body axis rotation was incomplete after 15 minutes. 1.5 T caused no rotational changes. The results show that exposure to the 7 Tesla static magnetic field causes only a temporary dysfunction or "over-compensation" of the vestibular system not measurable at 1.5 or 0 Tesla. Radiofrequency fields, gradient switching, and orthostatic dysregulation do not seem to play a role.}, language = {en} }