@article{LeursMezoOehlschlaegeretal.2012, author = {Leurs, Ulrike and Mezo, Gabor and {\"O}hlschl{\"a}ger, Peter and Orban, Erika and Marquard, Andrea and Manea, Marilena}, title = {Design, synthesis, in vitro stability and cytostatic effect of multifunctional anticancer drug-bioconjugates containing GnRH-III as a targeting moiety}, series = {Peptide Science}, volume = {98}, journal = {Peptide Science}, number = {1}, publisher = {Wiley}, address = {New York, NY}, issn = {1097-0282}, doi = {10.1002/bip.21640}, pages = {1 -- 10}, year = {2012}, abstract = {Bioconjugates containing the GnRH-III hormone decapeptide as a targeting moiety are able to deliver chemotherapeutic agents specifically to cancer cells expressing GnRH receptors, thereby increasing their local efficacy while limiting the peripheral toxicity. However, the number of GnRH receptors on cancer cells is limited and they desensitize under continuous hormone treatment. A possible approach to increase the receptor mediated tumor targeting and consequently the cytostatic effect of the bioconjugates would be the attachment of more than one chemotherapeutic agent to one GnRH-III molecule. Here we report on the design, synthesis and biochemical characterization of multifunctional bioconjugates containing GnRH-III as a targeting moiety and daunorubicin as a chemotherapeutic agent. Two different drug design approaches were pursued. The first one was based on the bifunctional [4Lys]-GnRH-III (Glp-His-Trp-Lys-His-Asp-Trp-Lys-Pro-Gly-NH2) containing two lysine residues in positions 4 and 8, whose ϵ-amino groups were used for the coupling of daunorubicin. In the second drug design, the native GnRH-III (Glp-His-Trp-Ser-His-Asp-Trp-Lys-Pro-Gly-NH2) was used as a scaffold; an additional lysine residue was coupled to the ϵ-amino group of 8Lys in order to generate two free amino groups available for conjugation of daunorubicin. The in vitro stability/degradation of all synthesized compounds was investigated in human serum, as well as in the presence of rat liver lysosomal homogenate. Their cellular uptake was determined on human breast cancer cells and the cytostatic effect was evaluated on human breast, colon and prostate cancer cell lines. Compared with a monofunctional compound, both drug design approaches resulted in multifunctional bioconjugates with increased cytostatic effect.}, language = {en} } @article{BitzFelderWittig2013, author = {Bitz, Andreas and Felder, Jorg and Wittig, Tilmann}, title = {Designing MRI Coils with Aid of Simulation}, series = {Microwaves \& RF}, volume = {52}, journal = {Microwaves \& RF}, number = {7}, publisher = {Penton}, address = {Cleveland, Ohio}, issn = {0745-2993}, pages = {56}, year = {2013}, language = {en} } @article{BindalSharmaJanseretal.2013, author = {Bindal, Gaurav and Sharma, Sparsh and Janser, Frank and Neu, Eugen}, title = {Detailed analysis of variables affecting wing kinematics of bat flight}, series = {SAE International Journal of Aerospace}, volume = {6}, journal = {SAE International Journal of Aerospace}, number = {2}, issn = {1946-3901}, doi = {10.4271/2013-01-9003}, pages = {811 -- 818}, year = {2013}, language = {en} } @article{RochefortVerverGrunendahletal.2005, author = {Rochefort, E. de and Verver, M. and Grunendahl, A. and Mooi, H. and Butenweg, Christoph}, title = {Detailed modelling of the lumbar spine for investigations of low back pain}, series = {SAE transactions : papers presented at Society and Section meetings / Society of Automotive Engineers}, volume = {Volume 114}, journal = {SAE transactions : papers presented at Society and Section meetings / Society of Automotive Engineers}, number = {Part 7}, organization = {Society of Automotive Engineers}, issn = {0096-736X}, pages = {788 -- 796}, year = {2005}, language = {en} } @article{GrajewskiKleefeld2023, author = {Grajewski, Matthias and Kleefeld, Andreas}, title = {Detecting and approximating decision boundaries in low-dimensional spaces}, series = {Numerical Algorithms}, volume = {93}, journal = {Numerical Algorithms}, number = {4}, publisher = {Springer Science+Business Media}, address = {Dordrecht}, issn = {1572-9265}, pages = {35 Seiten}, year = {2023}, abstract = {A method for detecting and approximating fault lines or surfaces, respectively, or decision curves in two and three dimensions with guaranteed accuracy is presented. Reformulated as a classification problem, our method starts from a set of scattered points along with the corresponding classification algorithm to construct a representation of a decision curve by points with prescribed maximal distance to the true decision curve. Hereby, our algorithm ensures that the representing point set covers the decision curve in its entire extent and features local refinement based on the geometric properties of the decision curve. We demonstrate applications of our method to problems related to the detection of faults, to multi-criteria decision aid and, in combination with Kirsch's factorization method, to solving an inverse acoustic scattering problem. In all applications we considered in this work, our method requires significantly less pointwise classifications than previously employed algorithms.}, language = {en} } @article{PoghossianSchoening2004, author = {Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Detecting Both Physical and (Bio-)Chemical Parameters by Means of ISFET Devices}, series = {Electroanalysis. 16 (2004), H. 22}, journal = {Electroanalysis. 16 (2004), H. 22}, isbn = {1040-0397}, pages = {1863 -- 1872}, year = {2004}, language = {en} } @article{AllefeldBialonski2007, author = {Allefeld, Carsten and Bialonski, Stephan}, title = {Detecting synchronization clusters in multivariate time series via coarse-graining of Markov chains}, series = {Physical Review E}, volume = {76}, journal = {Physical Review E}, number = {6}, issn = {2470-0053}, doi = {10.1103/PhysRevE.76.066207}, pages = {066207}, year = {2007}, language = {en} } @article{SchmichEdererEbert1992, author = {Schmich, Peter and Ederer, Hanns J. and Ebert, Klaus H.}, title = {Detection and identification of free radicals in hydrocarbon pyrolysis by an iodine trapping method}, series = {Industrial \& Engineering Chemistry Research. 31 (1992), H. 1}, journal = {Industrial \& Engineering Chemistry Research. 31 (1992), H. 1}, isbn = {1520-5045}, pages = {29 -- 37}, year = {1992}, language = {en} } @article{WeldenSeverinsPoghossianetal.2022, author = {Welden, Melanie and Severins, Robin and Poghossian, Arshak and Wege, Christina and Bongaerts, Johannes and Siegert, Petra and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Detection of acetoin and diacetyl by a tobacco mosaic virus-assisted field-effect biosensor}, series = {Chemosensors}, volume = {10}, journal = {Chemosensors}, number = {6}, publisher = {MDPI}, address = {Basel}, issn = {2227-9040}, doi = {10.3390/chemosensors10060218}, pages = {Artikel 218}, year = {2022}, abstract = {Acetoin and diacetyl have a major impact on the flavor of alcoholic beverages such as wine or beer. Therefore, their measurement is important during the fermentation process. Until now, gas chromatographic techniques have typically been applied; however, these require expensive laboratory equipment and trained staff, and do not allow for online monitoring. In this work, a capacitive electrolyte-insulator-semiconductor sensor modified with tobacco mosaic virus (TMV) particles as enzyme nanocarriers for the detection of acetoin and diacetyl is presented. The enzyme acetoin reductase from Alkalihalobacillus clausii DSM 8716ᵀ is immobilized via biotin-streptavidin affinity, binding to the surface of the TMV particles. The TMV-assisted biosensor is electrochemically characterized by means of leakage-current, capacitance-voltage, and constant capacitance measurements. In this paper, the novel biosensor is studied regarding its sensitivity and long-term stability in buffer solution. Moreover, the TMV-assisted capacitive field-effect sensor is applied for the detection of diacetyl for the first time. The measurement of acetoin and diacetyl with the same sensor setup is demonstrated. Finally, the successive detection of acetoin and diacetyl in buffer and in diluted beer is studied by tuning the sensitivity of the biosensor using the pH value of the measurement solution.}, language = {en} } @article{MolinnusBaeckerSiegertetal.2015, author = {Molinnus, Denise and B{\"a}cker, Matthias and Siegert, Petra and Willenberg, H. and Poghossian, Arshak and Keusgen, M. and Sch{\"o}ning, Michael Josef}, title = {Detection of Adrenaline Based on Substrate Recycling Amplification}, series = {Procedia Engineering}, volume = {120}, journal = {Procedia Engineering}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2015.08.708}, pages = {540 -- 543}, year = {2015}, abstract = {An amperometric enzyme biosensor has been applied for the detection of adrenaline. The adrenaline biosensor has been prepared by modification of an oxygen electrode with the enzyme laccase that operates at a broad pH range between pH 3.5 to pH 8. The enzyme molecules were immobilized via cross-linking with glutaraldehyde. The sensitivity of the developed adrenaline biosensor in different pH buffer solutions has been studied.}, language = {en} } @article{MolinnusHardtSiegertetal.2018, author = {Molinnus, Denise and Hardt, Gabriel and Siegert, Petra and Willenberg, Holger S. and Poghossian, Arshak and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Detection of Adrenaline in Blood Plasma as Biomarker for Adrenal Venous Sampling}, series = {Electroanalysis}, volume = {30}, journal = {Electroanalysis}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1521-4109}, doi = {10.1002/elan.201800026}, pages = {937 -- 942}, year = {2018}, abstract = {An amperometric bi-enzyme biosensor based on substrate recycling principle for the amplification of the sensor signal has been developed for the detection of adrenaline in blood. Adrenaline can be used as biomarker verifying successful adrenal venous sampling procedure. The adrenaline biosensor has been realized via modification of a galvanic oxygen sensor with a bi-enzyme membrane combining a genetically modified laccase and a pyrroloquinoline quinone-dependent glucose dehydrogenase. The measurement conditions such as pH value and temperature were optimized to enhance the sensor performance. A high sensitivity and a low detection limit of about 0.5-1 nM adrenaline have been achieved in phosphate buffer at pH 7.4, relevant for measurements in blood samples. The sensitivity of the biosensor to other catecholamines such as noradrenaline, dopamine and dobutamine has been studied. Finally, the sensor has been successfully applied for the detection of adrenaline in human blood plasma.}, language = {en} } @article{SchoeningPoghossian2008, author = {Sch{\"o}ning, Michael Josef and Poghossian, Arshak}, title = {Detection of charged macromolecules by means of field-effect devices (FEDs): possibilities and limitations}, series = {Electrochemical sensors, biosensors and their biomedical applications / ed. by Xueji Zhang ...}, journal = {Electrochemical sensors, biosensors and their biomedical applications / ed. by Xueji Zhang ...}, publisher = {Elsevier Acad. Press}, address = {Amsterdam}, isbn = {978-0-12-373738-0}, pages = {187 -- 212}, year = {2008}, language = {en} } @article{HerberErnstBussetal.1999, author = {Herber, R. and Ernst, S. and Buß, G. and Sch{\"o}ning, Michael Josef and Baltruschat, H.}, title = {Detection of hydrocarbons in air and water by adsorption on Pt electrodes using continuous impedance measurements}, series = {Proceedings of the Symposium on New Directions in Electroanalytical Chemistry II : [held at the 195th Meeting of the Electrochemical Society in Seattle, Washington on May 3 and 4, 1999] / Physical Electrochemistry, Sensor, and Organic and Biological Electrochemistry Divisions. Ed.: J. Leddy, P. Vanysek, M.D. Porter}, journal = {Proceedings of the Symposium on New Directions in Electroanalytical Chemistry II : [held at the 195th Meeting of the Electrochemical Society in Seattle, Washington on May 3 and 4, 1999] / Physical Electrochemistry, Sensor, and Organic and Biological Electrochemistry Divisions. Ed.: J. Leddy, P. Vanysek, M.D. Porter}, publisher = {Electrochemical Society}, address = {Pennington, NJ}, isbn = {1-56677-227-3}, pages = {168 -- 177}, year = {1999}, language = {en} } @article{OberlaenderKirchnerBoyenetal.2014, author = {Oberl{\"a}nder, Jan and Kirchner, Patrick and Boyen, Hans-Gerd and Sch{\"o}ning, Michael Josef}, title = {Detection of hydrogen peroxide vapor by use of manganese(IV) oxide as catalyst for calorimetric gas sensors}, series = {Physica status solidi A: Applications and materials science}, volume = {211}, journal = {Physica status solidi A: Applications and materials science}, number = {6}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1521-396X (E-Journal); 1862-6319 (E-Journal); 0031-8965 (Print); 1862-6300 (Print)}, doi = {10.1002/pssa.201330359}, pages = {1372 -- 1376}, year = {2014}, abstract = {In this work, the catalyst manganese(IV) oxide (MnO2), of calorimetric gas sensors (to monitor the sterilization agent vaporized hydrogen peroxide) has been investigated in more detail. Chemical analyses by means of X-ray-induced photoelectron spectroscopy have been performed to unravel the surface chemistry prior and after exposure to hydrogen peroxide vapor at elevated temperature, as applied in the sterilization processes of beverage cartons. The surface characterization reveals a change in oxidation states of the metal oxide catalyst after exposure to hydrogen peroxide. Additionally, a cleaning effect of the catalyst, which itself is attached to the sensor surface by means of a polymer interlayer, could be observed.}, language = {en} } @article{KassabHanPoghossianetal.2004, author = {Kassab, T. and Han, Y. and Poghossian, Arshak and Ingebrandt, S. and Offenh{\"a}usser, A. and Sch{\"o}ning, Michael Josef}, title = {Detection of layerby-layer adsorbed polyelectrolytes by means of field-effect based capacitive EIS structures}, series = {Biomedizinische Technik. 49 (2004), H. 2}, journal = {Biomedizinische Technik. 49 (2004), H. 2}, isbn = {0932-4666}, pages = {1034 -- 1035}, year = {2004}, language = {en} } @article{EmonsHuellenkremerSchoening2001, author = {Emons, H. and H{\"u}llenkremer, B. and Sch{\"o}ning, Michael Josef}, title = {Detection of metal ions in aqueous solutions by voltohmmetry}, series = {Fresenius' Journal of Analytical Chemistry. 369 (2001), H. 1}, journal = {Fresenius' Journal of Analytical Chemistry. 369 (2001), H. 1}, isbn = {0937-0633}, pages = {42 -- 46}, year = {2001}, language = {en} } @article{BronderJessingPoghossianetal.2018, author = {Bronder, Thomas and Jessing, Max P. and Poghossian, Arshak and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Detection of PCR-Amplified Tuberculosis DNA Fragments with Polyelectrolyte-Modified Field-Effect Sensors}, series = {Analytical Chemistry}, volume = {90}, journal = {Analytical Chemistry}, number = {12}, publisher = {ACS Publications}, address = {Washington, DC}, issn = {0003-2700}, doi = {10.1021/acs.analchem.8b01807}, pages = {7747 -- 7753}, year = {2018}, abstract = {Field-effect-based electrolyte-insulator-semiconductor (EIS) sensors were modified with a bilayer of positively charged weak polyelectrolyte (poly(allylamine hydrochloride) (PAH)) and probe single-stranded DNA (ssDNA) and are used for the detection of complementary single-stranded target DNA (cDNA) in different test solutions. The sensing mechanism is based on the detection of the intrinsic molecular charge of target cDNA molecules after the hybridization event between cDNA and immobilized probe ssDNA. The test solutions contain synthetic cDNA oligonucleotides (with a sequence of tuberculosis mycobacteria genome) or PCR-amplified DNA (which origins from a template DNA strand that has been extracted from Mycobacterium avium paratuberculosis-spiked human sputum samples), respectively. Sensor responses up to 41 mV have been measured for the test solutions with DNA, while only small signals of ∼5 mV were detected for solutions without DNA. The lower detection limit of the EIS sensors was ∼0.3 nM, and the sensitivity was ∼7.2 mV/decade. Fluorescence experiments using SybrGreen I fluorescence dye support the electrochemical results.}, language = {en} } @article{JablonskiPoghossianKeusgenetal.2021, author = {Jablonski, Melanie and Poghossian, Arshak and Keusgen, Michael and Wege, Christina and Sch{\"o}ning, Michael Josef}, title = {Detection of plant virus particles with a capacitive field-effect sensor}, series = {Analytical and Bioanalytical Chemistry}, volume = {413}, journal = {Analytical and Bioanalytical Chemistry}, publisher = {Springer Nature}, address = {Cham}, issn = {1618-2650}, doi = {10.1007/s00216-021-03448-8}, pages = {5669 -- 5678}, year = {2021}, abstract = {Plant viruses are major contributors to crop losses and induce high economic costs worldwide. For reliable, on-site and early detection of plant viral diseases, portable biosensors are of great interest. In this study, a field-effect SiO2-gate electrolyte-insulator-semiconductor (EIS) sensor was utilized for the label-free electrostatic detection of tobacco mosaic virus (TMV) particles as a model plant pathogen. The capacitive EIS sensor has been characterized regarding its TMV sensitivity by means of constant-capacitance method. The EIS sensor was able to detect biotinylated TMV particles from a solution with a TMV concentration as low as 0.025 nM. A good correlation between the registered EIS sensor signal and the density of adsorbed TMV particles assessed from scanning electron microscopy images of the SiO2-gate chip surface was observed. Additionally, the isoelectric point of the biotinylated TMV particles was determined via zeta potential measurements and the influence of ionic strength of the measurement solution on the TMV-modified EIS sensor signal has been studied.}, language = {en} } @article{WarmerWagnerSchoeningetal.2015, author = {Warmer, Johannes and Wagner, Patrick and Sch{\"o}ning, Michael Josef and Kaul, Peter}, title = {Detection of triacetone triperoxide using temperature cycled metal-oxide semiconductor gas sensors}, series = {Physica status solidi (a)}, volume = {212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431882}, pages = {1289 -- 1298}, year = {2015}, language = {en} } @article{SchoppRohrbachLangeretal.2024, author = {Schopp, Christoph and Rohrbach, Felix and Langer, Luc and Heuermann, Holger}, title = {Detection of welding wire length by active S11 measurement}, series = {IEEE Transactions on Plasma Science}, journal = {IEEE Transactions on Plasma Science}, number = {Early Access}, publisher = {IEEE}, issn = {0093-3813 (Print)}, doi = {10.1109/TPS.2024.3356659}, pages = {1 -- 6}, year = {2024}, abstract = {A novel method to determine the extruded length of a metallic wire for a directed energy deposition (DED) process using a microwave (MW) plasma jet with a straight-through wire feed is presented. The method is based on the relative comparison of the measured frequency response obtained by the large-signal scattering parameter (Hot-S) technique. In the practical working range, repeatability of less than 6\% for a nonactive plasma and 9\% for the active plasma state is found. Measurements are conducted with a focus on a simple solution to decrease the processing time and reduce the integration time of the process into the existing hardware. It is shown that monitoring a single frequency for magnitude and phase changes is sufficient to achieve good accuracy. A combination of different measurement values to determine the length is possible. The applicability to different diameter of the same material is shown as well as a contact detection of the wire and metallic substrate.}, language = {en} } @article{TippkoetterDeterdingUlber2008, author = {Tippk{\"o}tter, Nils and Deterding, A. and Ulber, Roland}, title = {Determination of acetic acid in fermentation broth by gas-diffusion technique}, series = {Engineering in Life Sciences}, volume = {8}, journal = {Engineering in Life Sciences}, number = {1, Special Issue: Technical Systems for the Use in Life Sciences}, doi = {10.1002/elsc.200820227}, pages = {62 -- 67}, year = {2008}, abstract = {Due to the interfering effects of acetic acid in many fermentation processes, a gas-diffusion technique was developed for the online determination of acetic acid. The measurements were accomplished with a flow diffusion analysis (FDA) unit from the TRACE Analytics GmbH, Braunschweig, Germany. The diffusion analysis is based on the UV-absorbance of acetic acid at 205 nm. The measurement was achieved by the separation of an acceptor and a carrier stream (acidified fermentation broth) using a gas permeable polytetrafluoroethylene (PTFE) membrane, whereby broth constituents that would otherwise disturb the UV-measurement of acetic acid, are held back efficiently. Merely, the fermentation by-products, e.g. formic acid, is capable of diffusing through the membrane. While formic acid can disturb the measurement, carbon dioxide does not absorb at 205 nm. The method operates with time-dependent sample enrichment. During the analysis, a small volume of the acceptor stream is stopped for a defined time interval in the acceptor chamber. During this period, the gaseous acetic acid diffuses through the membrane and is enriched in the acceptor chamber. Subsequently after the enrichment, the acceptor stream flows through a UV-detector. The intensity of the signal is proportional to the acetic acid concentration. Online measurements in bioreactors via a sterile filtration probe have been accomplished. A linear calibration in the range of 0.5-5.0 g/L acetic acid with a relative standard deviation of <5 \% was obtained. A sampling rate of 8 samples per hour was possible. The system was applied for the determination of acetic acid in E. coli fermentation broth. The instrument is easy to clean, very user-friendly and does not require any toxic or expensive reagents.}, language = {en} } @article{WagnerKloockSchoening2007, author = {Wagner, Torsten and Kloock, Joachim P. and Sch{\"o}ning, Michael Josef}, title = {Determination of cadmium concentration and pH value in aqueous solutions by means of a handheld light-addressable potentiometric sensor (LAPS) device}, series = {Electrochemical sensor analysis / edited by S. Alegret ...}, journal = {Electrochemical sensor analysis / edited by S. Alegret ...}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {978-0-444-53133-9}, pages = {e35 -- e44}, year = {2007}, language = {en} } @article{HelsperFissanThielen1983, author = {Helsper, Christoph and Fißan, H. J. and Thielen, H. J.}, title = {Determination of Particle Size Distributions by Means of an Electrostatic Classifier / Fißan, H. J.; Helsper, C. ; Thielen, H. J.}, series = {Journal of Aerosol Science. 14 (1983), H. 3}, journal = {Journal of Aerosol Science. 14 (1983), H. 3}, isbn = {0021-8502}, pages = {354 -- 357}, year = {1983}, language = {en} } @article{FoersterTillmannThust1996, author = {F{\"o}rster, Arnold and Tillmann, K. and Thust, M.}, title = {Determination of segregation, elastic strain and thin-foil relaxation in InxGa-1-x As islands on GaAs(001) by high resolution transmission electron microscopy / K. Tillmann ; A. Thust ; M. Lentzen ... A. F{\"o}rster ...}, series = {Philosophical magazine / Letters. 74 (1996), H. 5}, journal = {Philosophical magazine / Letters. 74 (1996), H. 5}, isbn = {1362-3036}, pages = {309 -- 315}, year = {1996}, language = {en} } @article{HelsperWiedensohlerWeiseetal.1986, author = {Helsper, Christoph and Wiedensohler, A. and Weise, W. and L{\"u}tkemeier, E.}, title = {Determination of the Bipolar Charge Equilibrium in Pure Gases / Wiedensohler, A. ; Weise, W. ; Helsper, C. ; L{\"u}tkemeier, E.}, series = {Aerosols : formation and reactivity ; proceedings of the second International Aerosol Conference, 22-26 Sept. 1986, Berlin (West) / Gesellschaft f{\"u}r Aerosolforschung (GAeF) ; American Association for Aerosol Research (AAAR)}, journal = {Aerosols : formation and reactivity ; proceedings of the second International Aerosol Conference, 22-26 Sept. 1986, Berlin (West) / Gesellschaft f{\"u}r Aerosolforschung (GAeF) ; American Association for Aerosol Research (AAAR)}, publisher = {Pergamon Press}, address = {Oxford [u.a.]}, pages = {383 -- 386}, year = {1986}, language = {en} } @article{MaggakisKelemenBiselliArtmann2002, author = {Maggakis-Kelemen, Christina and Biselli, Manfred and Artmann, Gerhard}, title = {Determination of the elastic shear modulus of cultured human red blood cells}, series = {Biomedizinische Technik. 47 (2002), H. Suppl. 1 Pt. 1}, journal = {Biomedizinische Technik. 47 (2002), H. Suppl. 1 Pt. 1}, isbn = {0013-5585}, pages = {106 -- 109}, year = {2002}, language = {en} } @article{WernerKrumbeSchumacheretal.2011, author = {Werner, Frederik and Krumbe, Christoph and Schumacher, Katharina and Groebel, Simone and Spelthahn, Heiko and Stellberg, Michael and Wagner, Torsten and Yoshinobu, Tatsuo and Selmer, Thorsten and Keusgen, Michael and Baumann, Marcus and Sch{\"o}ning, Michael Josef}, title = {Determination of the extracellular acidification of Escherichia coli by a light-addressable potentiometric sensor}, series = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, journal = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, publisher = {Wiley}, address = {Weinheim}, isbn = {1862-6319}, pages = {1340 -- 1344}, year = {2011}, language = {en} } @article{DantismTakenagaWagneretal.2016, author = {Dantism, Shahriar and Takenaga, Shoko and Wagner, Patrick and Wagner, Torsten and Sch{\"o}ning, Michael Josef}, title = {Determination of the extracellular acidification of Escherichia coli K12 with a multi-​chamber-​based LAPS system}, series = {Physica status solidi (a)}, volume = {213}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6300}, doi = {10.1002/pssa.201533043}, pages = {1479 -- 1485}, year = {2016}, abstract = {On-line monitoring of the metabolic activity of microorganisms involved in intermediate stages of biogas production plays an important role to avoid undesirable "down times" during the biogas production. In order to control this process, an on-chip differential measuring system based on the light-addressable potentiometric sensor (LAPS) principle combined with a 3D-printed multi-chamber structure has been realized. As a test microorganism, Escherichia coli K12 (E. coli K12) were used for cell-based measurements. Multi-chamber structures were developed to determine the metabolic activity of E. coli K12 in suspension for a different number of cells, responding to the addition of a constant or variable amount of glucose concentrations, enabling differential and simultaneous measurements.}, language = {en} } @article{HasanKeilStaatetal.2012, author = {Hasan, Istabrak and Keil, Ludger and Staat, Manfred and Wahl, Gerhard and Bourauel, Christoph}, title = {Determination of the frictional coefficient of the implant-antler interface : experimental approach}, series = {Biomedical Engineering / Biomedizinische Technik}, volume = {57}, journal = {Biomedical Engineering / Biomedizinische Technik}, number = {5}, publisher = {De Gruyter}, address = {Berlin}, issn = {1862-278X}, pages = {359 -- 363}, year = {2012}, abstract = {The similar bone structure of reindeer antler to human bone permits studying the osseointegration of dental implants in the jawbone. As the friction is one of the major factors that have a significant influence on the initial stability of immediately loaded dental implants, it is essential to define the frictional coefficient of the implant-antler interface. In this study, the kinetic frictional forces at the implant-antler interface were measured experimentally using an optomechanical setup and a stepping motor controller under different axial loads and sliding velocities. The corresponding mean values of the static and kinetic frictional coefficients were within the range of 0.5-0.7 and 0.3-0.5, respectively. An increase in the frictional forces with increasing applied axial loads was registered. The measurements showed an evidence of a decrease in the magnitude of the frictional coefficient with increasing sliding velocity. The results of this study provide a considerable assessment to clarify the suitable frictional coefficient to be used in the finite element contact analysis of antler specimens.}, language = {en} } @article{ArpshofenPoolSommeretal.1983, author = {Arpshofen, Ingo and Pool, M. J. and Sommer, Ferdinand and Gerling, Ulrich and Predel, Bruno and Schultheiss, Emil}, title = {Determination of the integral mixing enthalpies in the Cu-Pd-Si liquid ternary alloy system at 1600 K}, series = {Zeitschrift f{\"u}r Metallkunde : international journal of materials research and advanced techniques. Bd. 74, H. 1}, journal = {Zeitschrift f{\"u}r Metallkunde : international journal of materials research and advanced techniques. Bd. 74, H. 1}, issn = {0044-3093 ; 0179-4841}, pages = {25 -- 32}, year = {1983}, language = {en} } @article{SchererTuerlerGaeggeleretal.1988, author = {Scherer, Ulrich W. and T{\"u}rler, A. and G{\"a}ggeler, H. W. and Jost, D. T.}, title = {Determination of the Partial Electron-Capture- and Spontaneous-Fission Half-Lives of 254No / A. T{\"u}rler, H.W. G{\"a}ggeler, D.T. Jost, P. Armbruster, W. Br{\"u}chle, H. Folger, F.P. Heßberger, S. Hofmann,}, series = {Zeitschrift f{\"u}r Physik A Hadrons and Nuclei. 331 (1988), H. 3}, journal = {Zeitschrift f{\"u}r Physik A Hadrons and Nuclei. 331 (1988), H. 3}, isbn = {0939-7922}, pages = {363 -- 364}, year = {1988}, language = {en} } @article{Grap2003, author = {Grap, Rolf Dietmar}, title = {Determining manpower requirements in a spinning mill}, series = {Chemical fibers international : CFI ; fiber polymers, fibers, texturing, and spunbonds (2003)}, journal = {Chemical fibers international : CFI ; fiber polymers, fibers, texturing, and spunbonds (2003)}, isbn = {0340-3343}, pages = {455 -- 458}, year = {2003}, language = {en} } @article{SousaSiqueiraVerciketal.2017, author = {Sousa, Marcos A. M. and Siqueira, Jose R. Jr. and Vercik, Andres and Sch{\"o}ning, Michael Josef and Oliveira, Osvaldo N. Jr.}, title = {Determining the optimized layer-by-layer film architecture with dendrimer/carbon nanotubes for field-effect sensors}, series = {IEEE Sensors Journal}, volume = {17}, journal = {IEEE Sensors Journal}, number = {6}, publisher = {IEEE}, address = {New York}, issn = {1558-1748}, doi = {10.1109/JSEN.2017.2653238}, pages = {1735 -- 1740}, year = {2017}, abstract = {The capacitive electrolyte-insulator-semiconductor (EIS) structure is a typical device based on a field-effect sensor platform. With a simple silicon-based structure, EIS have been useful for several sensing applications, especially with incorporation of nanostructured films to modulate the ionic transport and the flat-band potential. In this paper, we report on ion transport and changes in flat-band potential in EIS sensors made with layer-by-layer films containing poly(amidoamine) (PAMAM) dendrimer and single-walled carbon nanotubes (SWNTs) adsorbed on p-Si/SiO 2 /Ta 2 O 5 chips with an Al ohmic contact. The impedance spectra were fitted using an equivalent circuit model, from which we could determine parameters such as the double-layer capacitance. This capacitance decreased with the number of bilayers owing to space charge accumulated at the electrolyte-insulator interface, up to three PAMAM/SWNTs bilayers, after which it stabilized. The charge-transfer resistance was also minimum for three bilayers, thus indicating that this is the ideal architecture for an optimized EIS performance. The understanding of the influence of nanostructures and the fine control of operation parameters pave the way for optimizing the design and performance of new EIS sensors.}, language = {en} } @article{PoettgenEdererAltherretal.2015, author = {P{\"o}ttgen, Philipp and Ederer, Thorsten and Altherr, Lena and Pelz, Peter F.}, title = {Developing a control strategy for booster stations under uncertain load}, series = {Applied Mechanics and Materials}, volume = {807}, journal = {Applied Mechanics and Materials}, number = {807}, publisher = {Trans Tech Publications}, address = {B{\"a}ch}, isbn = {1662-7482}, doi = {10.4028/www.scientific.net/AMM.807.241}, pages = {241 -- 246}, year = {2015}, abstract = {Booster stations can fulfill a varying pressure demand with high energy-efficiency, because individual pumps can be deactivated at smaller loads. Although this is a seemingly simple approach, it is not easy to decide precisely when to activate or deactivate pumps. Contemporary activation controls derive the switching points from the current volume flow through the system. However, it is not measured directly for various reasons. Instead, the controller estimates the flow based on other system properties. This causes further uncertainty for the switching decision. In this paper, we present a method to find a robust, yet energy-efficient activation strategy.}, language = {en} } @article{KueppersSteffenHellmuthetal.2014, author = {K{\"u}ppers, Tobias and Steffen, Victoria and Hellmuth, Hendrik and O'Connell, Timothy and Bongaerts, Johannes and Maurer, Karl-Heinz and Wiechert, Wolfgang}, title = {Developing a new production host from a blueprint: Bacillus pumilus as an industrial enzyme producer}, series = {Microbial cell factories}, volume = {13}, journal = {Microbial cell factories}, publisher = {BioMed Central}, address = {London}, issn = {1475-2859 (E-Journal)}, doi = {10.1186/1475-2859-13-46}, pages = {Article No. 46}, year = {2014}, language = {en} } @article{Bung2011, author = {Bung, Daniel B.}, title = {Developing flow in skimming flow regime on embankment stepped spillways}, series = {Journal of hydraulic research}, volume = {Vol. 49}, journal = {Journal of hydraulic research}, number = {Iss. 5}, publisher = {Taylor \& Francis}, address = {London}, issn = {1814-2079 (E-Journal); 0022-1686 (Print)}, pages = {639 -- 648}, year = {2011}, language = {en} } @article{WagnerWernerMiyamotoetal.2012, author = {Wagner, Torsten and Werner, Frederik and Miyamoto, Ko-Ichiro and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Development and characterisation of a compact light-addressable potentiometric sensor (LAPS) based on the digital light processing (DLP) technology for flexible chemical imaging}, series = {Sensors and Actuators B: Chemical}, volume = {170}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2010.12.003}, pages = {34 -- 39}, year = {2012}, abstract = {Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach to read out light-addressable potentiometric sensors (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device, which allows fast and flexible generation of light patterns. With the help of these light patterns, the sensor surface of the LAPS device can be addressed. The DLP approach has several advantages compared to conventional LAPS set-ups, e.g., the spot size and the shape of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of the measurement. In addition, the modulation frequency and intensity of the light beam are important parameters of the LAPS set-up. Within this work, the authors will discuss two different ways of light modulation by the DLP set-up, investigate the influence of different modulation frequencies and different light intensities as well as demonstrate the scanning capabilities of the new set-up by pH mapping on the sensor surface.}, language = {en} } @article{MolinnusMuschallikGonzalezetal.2018, author = {Molinnus, Denise and Muschallik, Lukas and Gonzalez, Laura Osorio and Bongaerts, Johannes and Wagner, Torsten and Selmer, Thorsten and Siegert, Petra and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Development and characterization of a field-effect biosensor for the detection of acetoin}, series = {Biosensors and Bioelectronics}, volume = {115}, journal = {Biosensors and Bioelectronics}, publisher = {Elsevier}, address = {Amsterdam}, doi = {10.1016/j.bios.2018.05.023}, pages = {1 -- 6}, year = {2018}, abstract = {A capacitive electrolyte-insulator-semiconductor (EIS) field-effect biosensor for acetoin detection has been presented for the first time. The EIS sensor consists of a layer structure of Al/p-Si/SiO₂/Ta₂O₅/enzyme acetoin reductase. The enzyme, also referred to as butane-2,3-diol dehydrogenase from B. clausii DSM 8716T, has been recently characterized. The enzyme catalyzes the (R)-specific reduction of racemic acetoin to (R,R)- and meso-butane-2,3-diol, respectively. Two different enzyme immobilization strategies (cross-linking by using glutaraldehyde and adsorption) have been studied. Typical biosensor parameters such as optimal pH working range, sensitivity, hysteresis, linear concentration range and long-term stability have been examined by means of constant-capacitance (ConCap) mode measurements. Furthermore, preliminary experiments have been successfully carried out for the detection of acetoin in diluted white wine samples.}, language = {en} } @article{TurekKettererClassenetal.2007, author = {Turek, Monika and Ketterer, Lothar and Claßen, Melanie and Berndt, Heinz and Elbers, Gereon and Kr{\"u}ger, Peter and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Development and Electrochemical Investigations of an EIS-(Electrolyte-Insulator-Semiconductor) based Biosensor for Cyanide Detection}, series = {Sensors}, volume = {7}, journal = {Sensors}, number = {8}, isbn = {1424-8220}, pages = {1415 -- 1426}, year = {2007}, language = {en} } @article{RietschBrunheimOrzadaetal.2019, author = {Rietsch, Stefan H. G. and Brunheim, Sascha and Orzada, Stephan and Voelker, Maximilian N. and Maderwald, Stefan and Bitz, Andreas and Gratz, Marcel and Ladd, Mark E. and Quick, Harald H.}, title = {Development and evaluation of a 16-channel receive-only RF coil to improve 7T ultra-high field body MRI with focus on the spine}, series = {Magnetic Resonance in Medicine}, journal = {Magnetic Resonance in Medicine}, number = {Early view}, publisher = {Wiley}, address = {Weinheim}, issn = {1522-2594}, doi = {10.1002/mrm.27731}, year = {2019}, language = {en} } @article{WolfFoltzSchlicketal.2002, author = {Wolf, Martin and Foltz, Christian and Schlick, Christopher and Luczak, Holger}, title = {Development and evaluation of a groupware system to support chemical design processes / Wolf, Martin ; Foltz, Christian ; Schlick, Christopher ; Luczak, Holger}, series = {International Journal of Human-Computer Interaction . 14 (2002), H. 2}, journal = {International Journal of Human-Computer Interaction . 14 (2002), H. 2}, publisher = {-}, isbn = {1044-7318}, pages = {181 -- 198}, year = {2002}, language = {en} } @article{KraemerDaabMuelleretal.2013, author = {Kr{\"a}mer, Stefan and Daab, Dominique Jonas and M{\"u}ller, Brigitte and Wagner, Tobias and Baader, Fabian and Hessel, Joana and Gdalewitsch, Georg and Plescher, Engelbert and Dachwald, Bernd and Wahle, Michael and Gierse, Andreas and Vetter, Rudolf and Pf{\"u}tzenreuter, Lysan}, title = {Development and flight-testing of a system to isolate vibrations for microgravity experiments on sounding rockets}, series = {21st ESA Symposium on Rocket and Balloon Research}, journal = {21st ESA Symposium on Rocket and Balloon Research}, pages = {1 -- 8}, year = {2013}, language = {en} } @article{EnningJenayehMuelleretal.1997, author = {Enning, Manfred and Jenayeh, I. and M{\"u}ller, C. and Rake, Heinrich}, title = {Development and realization of a manipulator for automatic decoupling of freight cars in marshalling yards / Jenayeh, I. ; M{\"u}ller, C. ; Enning, Manfred ; Rake, Heinrich ; Peter, J.}, year = {1997}, language = {en} } @article{FunkeRoennaRobinson2008, author = {Funke, Harald and R{\"o}nna, Uwe and Robinson, A. E.}, title = {Development and testing of a 10 kW diffusive micromix combustor for hydrogen-fuelled μ-scale gas turbines}, series = {Proceedings of ASME Turbo Expo 2008: Power for Land, Sea and Air ; GT2008 ; June 9-13, 2008, Berlin, Germany}, journal = {Proceedings of ASME Turbo Expo 2008: Power for Land, Sea and Air ; GT2008 ; June 9-13, 2008, Berlin, Germany}, publisher = {ASME}, address = {New York, NY}, pages = {1 -- 8}, year = {2008}, language = {en} } @article{StarkeDrews1985, author = {Starke, G{\"u}nther and Drews, P.}, title = {Development approaches for advanced control in automated arc welding}, pages = {115 -- 124}, year = {1985}, language = {en} } @article{SeifarthGossmannGrosseetal.2015, author = {Seifarth, Volker and Goßmann, Matthias and Grosse, J. O. and Becker, C. and Heschel, I. and Artmann, Gerhard and Temiz Artmann, Ayseg{\"u}l}, title = {Development of a Bioreactor to Culture Tissue Engineered Ureters Based on the Application of Tubular OPTIMAIX 3D Scaffolds}, series = {Urologia Internationalis}, volume = {2015}, journal = {Urologia Internationalis}, number = {95}, publisher = {Karger}, address = {Basel}, issn = {0042-1138}, doi = {10.1159/000368419}, pages = {106 -- 113}, year = {2015}, language = {en} } @article{KeusgenJuengerKrestetal.2003, author = {Keusgen, M. and J{\"u}nger, M. and Krest, I. and Sch{\"o}ning, Michael Josef}, title = {Development of a biosensor specific for cysteine sulfoxides}, series = {Biosensors \& Bioelectronics. 18 (2003), H. 5-6}, journal = {Biosensors \& Bioelectronics. 18 (2003), H. 5-6}, isbn = {0956-5663}, pages = {805 -- 812}, year = {2003}, language = {en} } @article{IkenBronderGoretzkietal.2019, author = {Iken, Heiko and Bronder, Thomas and Goretzki, Alexander and Kriesel, Jana and Ahlborn, Kristina and Gerlach, Frank and Vonau, Winfried and Zander, Willi and Schubert, J{\"u}rgen and Sch{\"o}ning, Michael Josef}, title = {Development of a Combined pH- and Redox-Sensitive Bi-Electrode Glass Thin-Film Sensor}, series = {physica status solidi a : applications and materials sciences}, volume = {216}, journal = {physica status solidi a : applications and materials sciences}, number = {12}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201900114}, pages = {1 -- 8}, year = {2019}, language = {en} } @article{DuenkelmannKolterJungNitscheetal.2002, author = {D{\"u}nkelmann, Pascal and Kolter-Jung, Doris and Nitsche, Adam and Demir, Ayhan S. and Siegert, Petra and Lingen, Bettina and Baumann, Martin and Pohl, Martina and M{\"u}ller, Michael}, title = {Development of a donor-acceptor concept for enzymatic cross-coupling reactions of adehydes : the first asymmetric cross-benzoin condensation}, series = {Journal of the American Chemical Society}, volume = {Vol. 124}, journal = {Journal of the American Chemical Society}, issn = {1520-5126 (E-Journal); 0002-7863 (Print)}, pages = {12084 -- 12085}, year = {2002}, language = {en} } @article{BiselliMeissnerSchroederetal.1999, author = {Biselli, Manfred and Meissner, Petra and Schr{\"o}der, Bernd and Herfurth, Cornelia}, title = {Development of a fixed bed bioreactor for the expansion of human hematopoietic progenitor cells / Meissner, Petra ; Schr{\"o}der, Bernd ; Herfurth, Cornelia ; Biselli, Manfred}, series = {Cytotechnology. 30 (1999), H. 1}, journal = {Cytotechnology. 30 (1999), H. 1}, isbn = {0920-9069}, pages = {227 -- 234}, year = {1999}, language = {en} } @article{SchoeningWagnerWangetal.2005, author = {Sch{\"o}ning, Michael Josef and Wagner, Torsten and Wang, C. and Otto, R. and Yoshinobu, T.}, title = {Development of a handheld 16 channel pen-type LAPS for electrochemical sensing}, series = {Sensors and Actuators B. 108 (2005)}, journal = {Sensors and Actuators B. 108 (2005)}, isbn = {0925-4005}, pages = {808 -- 814}, year = {2005}, language = {en} } @article{SchoeningWagnerWangetal.2004, author = {Sch{\"o}ning, Michael Josef and Wagner, Torsten and Wang, C. and Otto, R. and Yoshinobu, T.}, title = {Development of a handheld 16 channel pen-type LAPS for electrochemical sensing}, series = {Technical digest of the 10th International Meeting on Chemical Sensors, July 11 - 14, 2004, Tsukuba, Japan / Japan Association of Chemical Sensors}, journal = {Technical digest of the 10th International Meeting on Chemical Sensors, July 11 - 14, 2004, Tsukuba, Japan / Japan Association of Chemical Sensors}, publisher = {Japan Association of Chemical Sensors}, address = {Fukuoka}, pages = {136 -- 137}, year = {2004}, language = {en} } @article{ReisertHenkelSchneideretal.2010, author = {Reisert, Steffen and Henkel, Hartmut and Schneider, Andreas and Sch{\"a}fer, Daniel and Friedrich, Peter and Berger, J{\"o}rg and Sch{\"o}ning, Michael Josef}, title = {Development of a handheld sensor system for the online measurement of hydrogen peroxide in aseptic filling systems}, series = {Physica Status Solidi (A). 207 (2010), H. 4}, journal = {Physica Status Solidi (A). 207 (2010), H. 4}, isbn = {1862-6300}, pages = {913 -- 918}, year = {2010}, language = {en} } @article{TrillaGrossenRobinsonetal.2008, author = {Trilla, Joan and Grossen, J{\"u}rgen and Robinson, Alexander and Funke, Harald and Bosschaerts, Walter and Hendrick, Patrick}, title = {Development of a hydrogen combustion chamber for an ultra micro gas turbine}, series = {PowerMEMS 2008, 8th International Workshop on Micro and Nanotechnology for Power Generation and Energy Conversion Applications, microEMS 2008, 2nd Symposium on Micro Environmental Machine Systems, Sendai, JP, Nov 9-12, 2008}, journal = {PowerMEMS 2008, 8th International Workshop on Micro and Nanotechnology for Power Generation and Energy Conversion Applications, microEMS 2008, 2nd Symposium on Micro Environmental Machine Systems, Sendai, JP, Nov 9-12, 2008}, pages = {101 -- 104}, year = {2008}, language = {en} } @article{RobinsonFunkeHendricketal.2008, author = {Robinson, A. E. and Funke, Harald and Hendrick, P. and Recker, E. and Peirs, J.}, title = {Development of a hydrogen fuelled 1 kW ultra micro gas turbine with special respect to designing, testing and mapping of the µ-scale combustor}, series = {IEEE International Conference on Sustainable Energy Technologies, 2008 : ICSET 2008 ; Singapore, 24 - 27 Nov. 2008.}, journal = {IEEE International Conference on Sustainable Energy Technologies, 2008 : ICSET 2008 ; Singapore, 24 - 27 Nov. 2008.}, publisher = {IEEE}, address = {Piscataway, NJ}, isbn = {978-1-4244-1887-9}, pages = {656 -- 660}, year = {2008}, language = {en} } @article{PilasIkenSelmeretal.2015, author = {Pilas, Johanna and Iken, Heiko and Selmer, Thorsten and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Development of a multi-parameter sensor chip for the simultaneous detection of organic compounds in biogas processes}, series = {Physica status solidi (a)}, volume = {212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431894}, pages = {1306 -- 1312}, year = {2015}, abstract = {An enzyme-based multi-parameter biosensor is developed for monitoring the concentration of formate, d-lactate, and l-lactate in biological samples. The sensor is based on the specific dehydrogenation by an oxidized β-nicotinamide adenine dinucleotide (NAD+)-dependent dehydrogenase (formate dehydrogenase, d-lactic dehydrogenase, and l-lactic dehydrogenase, respectively) in combination with a diaphorase from Clostridium kluyveri (EC 1.8.1.4). The enzymes are immobilized on a platinum working electrode by cross-linking with glutaraldehyde (GA). The principle of the determination scheme in case of l-lactate is as follows: l-lactic dehydrogenase (l-LDH) converts l-lactate into pyruvate by reaction with NAD+. In the presence of hexacyanoferrate(III), the resulting reduced β-nicotinamide adenine dinucleotide (NADH) is then regenerated enzymatically by diaphorase. The electrochemical detection is based on the current generated by oxidation of hexacyanoferrate(II) at an applied potential of +0.3 V vs. an Ag/AgCl reference electrode. The biosensor will be electrochemically characterized in terms of linear working range and sensitivity. Additionally, the successful practical application of the sensor is demonstrated in an extract from maize silage.}, language = {en} } @article{FunkeRobinson2007, author = {Funke, Harald and Robinson, A. E.}, title = {Development of a new test rig for a micro scale hydrogen combustion chamber}, series = {Proceedings of the 2nd European Conference for Aero-Space Sciences : July 1 - 6, 2007, Brussels, Belgium}, journal = {Proceedings of the 2nd European Conference for Aero-Space Sciences : July 1 - 6, 2007, Brussels, Belgium}, publisher = {-}, pages = {1 -- 8}, year = {2007}, language = {en} } @article{JildehKirchnerOberlaenderetal.2020, author = {Jildeh, Zaid B. and Kirchner, Patrick and Oberl{\"a}nder, Jan and Vahidpour, Farnoosh and Wagner, Patrick H. and Sch{\"o}ning, Michael Josef}, title = {Development of a package-sterilization process for aseptic filling machines: A numerical approach and validation for surface treatment with hydrogen peroxide}, series = {Sensor and Actuators A: Physical}, volume = {303}, journal = {Sensor and Actuators A: Physical}, number = {111691}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0924-4247}, doi = {10.1016/j.sna.2019.111691}, year = {2020}, abstract = {Within the present work a sterilization process by a heated gas mixture that contains hydrogen peroxide (H₂O₂) is validated by experiments and numerical modeling techniques. The operational parameters that affect the sterilization efficacy are described alongside the two modes of sterilization: gaseous and condensed H₂O₂. Measurements with a previously developed H₂O₂ gas sensor are carried out to validate the applied H₂O₂ gas concentration during sterilization. We performed microbiological tests at different H₂O₂ gas concentrations by applying an end-point method to carrier strips, which contain different inoculation loads of Geobacillus stearothermophilus spores. The analysis of the sterilization process of a pharmaceutical glass vial is performed by numerical modeling. The numerical model combines heat- and advection-diffusion mass transfer with vapor-pressure equations to predict the location of condensate formation and the concentration of H₂O₂ at the packaging surfaces by changing the gas temperature. For a sterilization process of 0.7 s, a H₂O₂ gas concentration above 4\% v/v is required to reach a log-count reduction above six. The numerical results showed the location of H₂O₂ condensate formation, which decreases with increasing sterilant-gas temperature. The model can be transferred to different gas nozzle- and packaging geometries to assure the absence of H₂O₂ residues.}, language = {en} } @article{AboulnagaZouSelmeretal.2018, author = {Aboulnaga, E. A. and Zou, H. and Selmer, Thorsten and Xian, M.}, title = {Development of a plasmid-based, tunable, tolC-derived expression system for application in Cupriavidus necator H16}, series = {Journal of Biotechnology}, volume = {274}, journal = {Journal of Biotechnology}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0168-1656}, doi = {10.1016/j.jbiotec.2018.03.007}, pages = {15 -- 27}, year = {2018}, abstract = {Cupriavidus necator H16 gains increasing attention in microbial research and biotechnological application due to its diverse metabolic features. Here we present a tightly controlled gene expression system for C. necator including the pBBR1-vector that contains hybrid promoters originating from C. necator native tolC-promoter in combination with a synthetic tetO-operator. The expression of the reporter gene from these plasmids relies on the addition of the exogenous inducer doxycycline (dc). The novel expression system offers a combination of advantageous features as; (i) high and dose-dependent recombinant protein production, (ii) tight control with a high dynamic range (On/Off ratio), which makes it applicable for harmful pathways or for toxic protein production, (iii) comparable cheap inducer (doxycycline, dc), (iv) effective at low inducer concentration, that makes it useful for large scale application, (v) rapid, diffusion controlled induction, and (vi) the inducer does not interfere within the cell metabolism. As applications of the expression system in C. necator H16, the growth ability on glycerol was enhanced by constitutively expressing the E. coli glpk gene-encoding for glycerol kinase. Likewise, we used the system to overcome the expression toxicity of mevalonate pathway in C. necator H16. With this system, the mevalonate-genes were successfully introduced in the host and the recombinant strains could produce about 200 mg/l mevalonate.}, language = {en} } @article{BiselliHambachRunstadleretal.1992, author = {Biselli, Manfred and Hambach, B. and Runstadler, P. W. and Wandrey, Christian}, title = {Development of a reactor-integrated aeration system for cultivation of animal cells in fluidized beds / Hambach, B. ; Biselli, M. ; Runstadler, P.W. ; Wandrey, C.}, series = {Animal cell technology : developments, processes, and products ; ESACT, European Society for Animal Cell Technology, the 11th meeting / Ed. R. E. Spier}, journal = {Animal cell technology : developments, processes, and products ; ESACT, European Society for Animal Cell Technology, the 11th meeting / Ed. R. E. Spier}, publisher = {Butterworth-Heinemann}, address = {Oxford}, isbn = {0750604212}, pages = {381 -- 385}, year = {1992}, language = {en} } @article{WertIkenSchoeningetal.2021, author = {Wert, Stefan and Iken, Heiko and Sch{\"o}ning, Michael Josef and Matysik, Frank-Michael}, title = {Development of a temperature-pulse enhanced electrochemical glucose biosensor and characterization of its stability via scanning electrochemical microscopy}, series = {Electroanalysis}, journal = {Electroanalysis}, number = {Early View}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1521-4109}, doi = {10.1002/elan.202100089}, year = {2021}, abstract = {Glucose oxidase (GOx) is an enzyme frequently used in glucose biosensors. As increased temperatures can enhance the performance of electrochemical sensors, we investigated the impact of temperature pulses on GOx that was drop-coated on flattened Pt microwires. The wires were heated by an alternating current. The sensitivity towards glucose and the temperature stability of GOx was investigated by amperometry. An up to 22-fold increase of sensitivity was observed. Spatially resolved enzyme activity changes were investigated via scanning electrochemical microscopy. The application of short (<100 ms) heat pulses was associated with less thermal inactivation of the immobilized GOx than long-term heating.}, language = {en} } @article{HailerWeberNevelingetal.2020, author = {Hailer, Benjamin and Weber, Tobias and Neveling, Sebastian and Dera, Samuel and Arent, Jan-Christoph and Middendorf, Peter}, title = {Development of a test device to determine the frictional behavior between honeycomb and prepreg layers under realistic manufacturing conditions}, series = {Journal of Sandwich Structures \& Materials}, journal = {Journal of Sandwich Structures \& Materials}, number = {Volume 23, Issue 7}, publisher = {Sage}, address = {London}, issn = {1530-7972}, doi = {10.1177/1099636220923986}, pages = {3017 -- 3043}, year = {2020}, abstract = {In the friction tests between honeycomb with film adhesive and prepreg, the relative displacement occurs between the film adhesive and the prepreg. The film adhesive does not shift relative to the honeycomb. This is consistent with the core crush behavior where the honeycomb moves together with the film adhesive, as can be seen in Figure 2(a). The pull-through forces of the friction measurements between honeycomb and prepreg at 1 mm deformation are plotted in Figure 17(a). While the friction at 100°C is similar to the friction at 120°C, it decreases significantly at 130°C and exhibits a minimum at 140°C. At 150°C, the friction rises again slightly and then sharply at 160°C. Since the viscosity of the M18/1 prepreg resin drops significantly before it cures [23], the minimum friction at 140°C could result from a minimum viscosity of the mixture of prepreg resin and film adhesive before the bond subsequently cures. Figure 17(b) shows the mean value curve of the friction measurements at 140°C. The error bars, which represent the standard deviation, reveal the good repeatability of the tests. The force curve is approximately horizontal between 1 mm and 2 mm. The friction then slightly rises. As with interlaminar friction measurements, this could be due to the fact that resin is removed by friction and the proportion of boundary lubrication increases. Figure 18 shows the surfaces after the friction measurement. The honeycomb cell walls are clearly visible in the film adhesive. There are areas where the film adhesive is completely removed and the carrier material of the film adhesive becomes visible. In addition, the viscosity of the resin changes as the curing progresses during the friction test. This can also affect the force-displacement curve.}, language = {en} } @article{SpelthahnKirsanovLeginetal.2012, author = {Spelthahn, Heiko and Kirsanov, Dmitry and Legin, Andrey and Osterrath, Thomas and Schubert, J{\"u}rgen and Zander, Willi and Sch{\"o}ning, Michael Josef}, title = {Development of a thin-film sensor array for analytical monitoring of heavy metals in aqueous solutions}, series = {Physica Status Solidi (a)}, volume = {209}, journal = {Physica Status Solidi (a)}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, isbn = {1862-6319}, doi = {10.1002/pssa.201100733}, pages = {885 -- 891}, year = {2012}, abstract = {In industrial processes there is a variety of heavy metals (e.g., copper, zinc, cadmium, and lead) in use for wires, coatings, paints, alloys, batteries, etc. Since the application of these transition metals for industry is inevitable, it is a vital task to develop proper analytical techniques for their monitoring at low activity levels, especially because most of these elements are acutely toxic for biological organisms. The determination of ions in solution by means of a simple and inexpensive sensor array is, therefore, a promising task. In this work, a sensor array with heavy metal-sensitive chalcogenide glass membranes for the simultaneous detection of the four ions Ag⁺, Cu2⁺, Cd2⁺, and Pb2⁺ in solution is realized. The results of the physical characterization by means of microscopy, profilometry, Rutherford backscattering spectroscopy (RBS), and scanning electron microscopy (SEM) as well as the electrochemical characterization by means of potentiometric measurements are presented. Additionally, the possibility to expand the sensor array by polymeric sensor membranes is discussed.}, language = {en} } @article{RoehlenPilasSchoeningetal.2017, author = {R{\"o}hlen, Desiree and Pilas, Johanna and Sch{\"o}ning, Michael Josef and Selmer, Thorsten}, title = {Development of an amperometric biosensor platform for the combined determination of l-Malic, Fumaric, and l-Aspartic acid}, series = {Applied Biochemistry and Biotechnology}, volume = {183}, journal = {Applied Biochemistry and Biotechnology}, publisher = {Springer}, address = {Berlin}, issn = {1559-0291}, doi = {10.1007/s12010-017-2578-1}, pages = {566 -- 581}, year = {2017}, abstract = {Three amperometric biosensors have been developed for the detection of L-malic acid, fumaric acid, and L -aspartic acid, all based on the combination of a malate-specific dehydrogenase (MDH, EC 1.1.1.37) and diaphorase (DIA, EC 1.8.1.4). The stepwise expansion of the malate platform with the enzymes fumarate hydratase (FH, EC 4.2.1.2) and aspartate ammonia-lyase (ASPA, EC 4.3.1.1) resulted in multi-enzyme reaction cascades and, thus, augmentation of the substrate spectrum of the sensors. Electrochemical measurements were carried out in presence of the cofactor β-nicotinamide adenine dinucleotide (NAD+) and the redox mediator hexacyanoferrate (III) (HCFIII). The amperometric detection is mediated by oxidation of hexacyanoferrate (II) (HCFII) at an applied potential of + 0.3 V vs. Ag/AgCl. For each biosensor, optimum working conditions were defined by adjustment of cofactor concentrations, buffer pH, and immobilization procedure. Under these improved conditions, amperometric responses were linear up to 3.0 mM for L-malate and fumarate, respectively, with a corresponding sensitivity of 0.7 μA mM-1 (L-malate biosensor) and 0.4 μA mM-1 (fumarate biosensor). The L-aspartate detection system displayed a linear range of 1.0-10.0 mM with a sensitivity of 0.09 μA mM-1. The sensor characteristics suggest that the developed platform provides a promising method for the detection and differentiation of the three substrates.}, language = {en} } @article{SpelthahnSchaffrathCoppeetal.2010, author = {Spelthahn, Heiko and Schaffrath, Sophie and Coppe, Thomas and Rufi, Frederic and Sch{\"o}ning, Michael Josef}, title = {Development of an electrolyte-insulator-semiconductor (EIS) based capacitive heavy metal sensor for the detection of Pb2+ und Cd2+ ions}, series = {Physica status solidi (a) : applications and material science. 207 (2010), H. 4}, journal = {Physica status solidi (a) : applications and material science. 207 (2010), H. 4}, isbn = {1862-6300}, pages = {930 -- 934}, year = {2010}, language = {en} } @article{BiselliVanderPolJokschetal.1992, author = {Biselli, Manfred and Van der Pol, Jens J. and Joksch, B. and Eberhardt, R.}, title = {Development of an enzymatic multichannel flow injection analysis system for monitoring mammalian cell fermentations / Van der Pol, J.J.; Joksch, B.; Eberhardt, R.; Biselli, M.; Wandrey, C., Tramper, J.}, series = {Biosensors : fundamentals, technologies and applications ; contributions to the BMFT status seminar with international participation May, 12 to 14, 1991, Internationales Bildungs-Centrum Bogensee/Brandenburg, Germany / org. by ZIM-Zentralinstitut f{\"u}r Molekularbiologie, Berlin-Buch and GBF, Braunschweig. Ed. by F. Scheller}, journal = {Biosensors : fundamentals, technologies and applications ; contributions to the BMFT status seminar with international participation May, 12 to 14, 1991, Internationales Bildungs-Centrum Bogensee/Brandenburg, Germany / org. by ZIM-Zentralinstitut f{\"u}r Molekularbiologie, Berlin-Buch and GBF, Braunschweig. Ed. by F. Scheller}, publisher = {VCH}, address = {Weinheim}, isbn = {3527284370}, pages = {349 -- 352}, year = {1992}, language = {en} } @article{JildehKirchnerBaltesetal.2019, author = {Jildeh, Zaid B. and Kirchner, Patrick and Baltes, Klaus and Wagner, Patrick H. and Sch{\"o}ning, Michael Josef}, title = {Development of an in-line evaporation unit for the production of gas mixtures containing hydrogen peroxide - numerical modeling and experimental results}, series = {International Journal of Heat and Mass Transfer}, volume = {143}, journal = {International Journal of Heat and Mass Transfer}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0017-9310}, doi = {10.1016/j.ijheatmasstransfer.2019.118519}, pages = {Article number 118519}, year = {2019}, abstract = {Hydrogen peroxide (H2O2) is a typical surface sterilization agent for packaging materials used in the pharmaceutical, food and beverage industries. We use the finite-elements method to analyze the conceptual design of an in-line thermal evaporation unit to produce a heated gas mixture of air and evaporated H2O2 solution. For the numerical model, the required phase-transition variables of pure H2O2 solution and of the aerosol mixture are acquired from vapor-liquid equilibrium (VLE) diagrams derived from vapor-pressure formulations. This work combines homogeneous single-phase turbulent flow with heat-transfer physics to describe the operation of the evaporation unit. We introduce the apparent heat-capacity concept to approximate the non-isothermal phase-transition process of the H2O2-containing aerosol. Empirical and analytical functions are defined to represent the temperature- and pressure-dependent material properties of the aqueous H2O2 solution, the aerosol and the gas mixture. To validate the numerical model, the simulation results are compared to experimental data on the heating power required to produce the gas mixture. This shows good agreement with the deviations below 10\%. Experimental observations on the formation of deposits due to the evaporation of stabilized H2O2 solution fits the prediction made from simulation results.}, language = {en} } @article{MossetDevroedeKriegueretal.2006, author = {Mosset, J.-B. and Devroede, O. and Krieguer, M. and Rey, M. and Vieira, J.-M. and Jung, J. H. and Kuntner, C. and Streun, M. and Ziemons, Karl and Auffray, E. and Sempere-Roldan, P. and Lecoq, P. and Bruyndonckx, P. and Loude, J.-F. and Tavernier, S. and Morcel, C.}, title = {Development of an optimized LSO/LuYAP phoswich detector head for the Lausanne ClearPET demonstrator}, series = {IEEE Transactions on Nuclear Science}, volume = {53}, journal = {IEEE Transactions on Nuclear Science}, number = {1}, isbn = {0018-9499}, pages = {25 -- 29}, year = {2006}, abstract = {This paper describes the LSO/LuYAP phoswich detector head developed for the ClearPET small animal PET scanner demonstrator that is under construction in Lausanne within the Crystal Clear Collaboration. The detector head consists of a dual layer of 8×8 LSO and LuYAP crystal arrays coupled to a multi-anode photomultiplier tube (Hamamatsu R7600-M64). Equalistion of the LSO/LuYAP light collection is obtained through partial attenuation of the LSO scintillation light using a thin aluminum deposit of 20-35 nm on LSO and appropriate temperature regulation of the phoswich head between 30°C to 60°C. At 511keV, typical FWHM energy resolutions of the pixels of a phoswich head amounts to (28±2)\% for LSO and (25±2)\% for LuYAP. The LSO versus LuYAP crystal identification efficiency is better than 98\%. Six detector modules have been mounted on a rotating gantry. Axial and tangential spatial resolutions were measured up to 4 cm from the scanner axis and compared to Monte Carlo simulations using GATE. FWHM spatial resolution ranges from 1.3 mm on axis to 2.6 mm at 4 cm from the axis.}, language = {en} } @article{HoffschmidtFernandezKonstandopoulus2001, author = {Hoffschmidt, Bernhard and Fernandez, V. and Konstandopoulus, A. G.}, title = {Development of ceramic volumetric receiver technology}, series = {Forschungsbericht : DLR FB. 10 (2001)}, journal = {Forschungsbericht : DLR FB. 10 (2001)}, isbn = {0939-2963}, pages = {51 -- 61}, year = {2001}, language = {en} } @article{EdipSesovButenwegetal.2018, author = {Edip, K. and Sesov, V. and Butenweg, Christoph and Bojadjieva, J.}, title = {Development of coupled numerical model for simulation of multiphase soil}, series = {Computers and Geotechnics}, volume = {96}, journal = {Computers and Geotechnics}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0266-352X}, doi = {10.1016/j.compgeo.2017.08.016}, pages = {118 -- 131}, year = {2018}, abstract = {In this paper, a coupled multiphase model considering both non-linearities of water retention curves and solid state modeling is proposed. The solid displacements and the pressures of both water and air phases are unknowns of the proposed model. The finite element method is used to solve the governing differential equations. The proposed method is demonstrated through simulation of seepage test and partially consolidation problem. Then, implementation of the model is done by using hypoplasticity for the solid phase and analyzing the fully saturated triaxial experiments. In integration of the constitutive law error controlling is improved and comparisons done accordingly. In this work, the advantages and limitations of the numerical model are discussed.}, language = {en} } @article{Kaemper1996, author = {K{\"a}mper, Klaus-Peter}, title = {Development of low-cost injection moulded micropumps. Entwicklung von kosteng{\"u}nstigen, mittels Spritzguß hergestellten Mikropumpen / D{\"o}pper, J. (u.a.)}, series = {Actuator 96 : Conference Proceedings ; 5th International Conference on New Actuators ; 26- 28 June, Bremen, Germany / Ed.: Hubert Borgmann. Publ. by: AXON Technology Consult GmbH}, journal = {Actuator 96 : Conference Proceedings ; 5th International Conference on New Actuators ; 26- 28 June, Bremen, Germany / Ed.: Hubert Borgmann. Publ. by: AXON Technology Consult GmbH}, address = {Bremen}, pages = {37 -- 40}, year = {1996}, language = {en} } @article{KaemperLehrEhrfeldetal.1997, author = {K{\"a}mper, Klaus-Peter and Lehr, H. and Ehrfeld, W. and Hagemann, B.}, title = {Development of micro and millimotors. Lehr, H.; Ehrfeld, W.; Hagemann, B.; K{\"a}mper, K.-P.; Michel, F.; Schulz, C.; Th{\"u}rigen C.}, series = {Minimally Invasive Therapy and Allied Technologies. 6 (1997)}, journal = {Minimally Invasive Therapy and Allied Technologies. 6 (1997)}, isbn = {1364-5706}, year = {1997}, language = {en} } @article{MourzinaSchubertZanderetal.2001, author = {Mourzina, Yu. G. and Schubert, J and Zander, W. and Legin, A. and Vlasov, Y. G. and L{\"u}th, H. and Sch{\"o}ning, Michael Josef}, title = {Development of multisensor systems based on chalcogenide thin film chemical sensors for the simultaneous multicomponent analysis of metal ions in complex solutions}, series = {Scaling down in electrochemistry : electrochemical micro- and nanosystem technology ; proceedings of the 3rd International Symposium on Electrochemical Microsystem Technologies, Garmisch-Patenkirchen, Germany, 11 - 15 September 2000 / ed. by J. W. Schultz}, journal = {Scaling down in electrochemistry : electrochemical micro- and nanosystem technology ; proceedings of the 3rd International Symposium on Electrochemical Microsystem Technologies, Garmisch-Patenkirchen, Germany, 11 - 15 September 2000 / ed. by J. W. Schultz}, publisher = {Elsevier [u.a.]}, address = {Amsterdam [u.a.]}, isbn = {0-08-044014-2}, pages = {251 -- 263}, year = {2001}, language = {en} } @article{IkenAhlbornGerlachetal.2013, author = {Iken, Heiko and Ahlborn, K. and Gerlach, F. and Vonau, W. and Zander, W. and Schubert, J. and Sch{\"o}ning, Michael Josef}, title = {Development of redox glasses and subsequent processing by means of pulsed laser deposition for realizing silicon-based thin-film sensors}, series = {Electrochimica acta}, journal = {Electrochimica acta}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3859 (E-Journal); 0013-4686 (Print)}, pages = {Available online 30.8.2013}, year = {2013}, language = {en} } @article{ValeroBung2016, author = {Valero, Daniel and Bung, Daniel B.}, title = {Development of the interfacial air layer in the non-aerated region of high-velocity spillway flows: Instabilities growth, entrapped air and influence on the self-aeration onset}, series = {International Journal of Multiphase Flow}, volume = {84}, journal = {International Journal of Multiphase Flow}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0301-9322}, doi = {10.1016/j.ijmultiphaseflow.2016.04.012}, pages = {66 -- 74}, year = {2016}, abstract = {Self-aeration is traditionally explained by the water turbulent boundary layer outer edge intersection with the free surface. This paper presents a discussion on the commonly accepted hypothesis behind the computation of the critical point of self-aeration in spillway flows and a new formulation is proposed based on the existence of a developing air flow over the free surface. Upstream of the inception point of self-aeration, some surface roughening has been often reported in previous studies which consequently implies some entrapped air transport and air-water flows coupling. Such air flow is proven in this study by presenting measured air velocities and computing the air boundary layer thickness for a 1V:2H smooth chute flow. Additionally, the growth rate of free surface waves has been analysed by means of Ultrasonic Sensors measurements, obtaining also the entrapped air concentration. High-speed camera imaging has been used for qualitative study of the flow perturbations.}, language = {en} } @article{GuoMiyamotoWagneretal.2014, author = {Guo, Yuanyuan and Miyamoto, Ko-ichiro and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Device simulation of the light-addressable potentiometric sensor for the investigation of the spatial resolution}, series = {Sensors and actuators B: Chemical}, volume = {204}, journal = {Sensors and actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3077 (E-Journal); 0925-4005 (Print)}, doi = {10.1016/j.snb.2014.08.016}, pages = {659 -- 665}, year = {2014}, abstract = {As a semiconductor-based electrochemical sensor, the light-addressable potentiometric sensor (LAPS) can realize two dimensional visualization of (bio-)chemical reactions at the sensor surface addressed by localized illumination. Thanks to this imaging capability, various applications in biochemical and biomedical fields are expected, for which the spatial resolution is critically significant. In this study, therefore, the spatial resolution of the LAPS was investigated in detail based on the device simulation. By calculating the spatiotemporal change of the distributions of electrons and holes inside the semiconductor layer in response to a modulated illumination, the photocurrent response as well as the spatial resolution was obtained as a function of various parameters such as the thickness of the Si substrate, the doping concentration, the wavelength and the intensity of illumination. The simulation results verified that both thinning the semiconductor substrate and increasing the doping concentration could improve the spatial resolution, which were in good agreement with known experimental results and theoretical analysis. More importantly, new findings of interests were also obtained. As for the dependence on the wavelength of illumination, it was found that the known dependence was not always the case. When the Si substrate was thick, a longer wavelength resulted in a higher spatial resolution which was known by experiments. When the Si substrate was thin, however, a longer wavelength of light resulted in a lower spatial resolution. This finding was explained as an effect of raised concentration of carriers, which reduced the thickness of the space charge region. The device simulation was found to be helpful to understand the relationship between the spatial resolution and device parameters, to understand the physics behind it, and to optimize the device structure and measurement conditions for realizing higher performance of chemical imaging systems.}, language = {en} } @article{GuoSekiMiyamotoetal.2014, author = {Guo, Yuanyuan and Seki, Kosuke and Miyamoto, Ko-ichiro and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Device simulation of the light-addressable potentiometric sensor with a novel photoexcitation method for a higher spatial resolution}, series = {Procedia Engineering}, volume = {87}, journal = {Procedia Engineering}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2014.11.369}, pages = {456 -- 459}, year = {2014}, abstract = {A novel photoexcitation method for the light-addressable potentiometric sensor (LAPS) realized a higher spatial resolution of chemical imaging. In this method, a modulated light probe, which generates the alternating photocurrent signal, is surrounded by a ring of constant light, which suppresses the lateral diffusion of photocarriers by enhancing recombination. A device simulation verified that a higher spatial resolution could be obtained by adjusting the gap between the modulated and constant light. It was also found that a higher intensity and a longer wavelength of constant light was more effective. However, there exists a tradeoff between the spatial resolution and the amplitude of the photocurrent, and thus, the signal-to-noise ratio. A tilted incidence of constant light was applied, which could achieve even higher resolution with a smaller loss of photocurrent.}, language = {en} } @article{HagemannBachmannLadeetal.1994, author = {Hagemann, Hans-J{\"u}rgen and Bachmann, P.K. and Lade, H. and Leers, D.}, title = {Diamond chemical vapor deposition: gas compositions and film properties / Bachmann, P.K.; Hagemann, H.-J.; Lade, H; Leers, D.; Picht, F.; Wiechert, D.U.; Wilson, H.}, series = {Diamond, SiC and nitride wide bandgap semiconductors : symposium held April 4 - 8, 1994, San Francisco, California, U.S.A. / ed.: Calvin H. Carter, Jr. ...}, journal = {Diamond, SiC and nitride wide bandgap semiconductors : symposium held April 4 - 8, 1994, San Francisco, California, U.S.A. / ed.: Calvin H. Carter, Jr. ...}, address = {Pittsburgh, Penn.}, isbn = {1-55899-239-1}, pages = {267 -- 277}, year = {1994}, language = {en} } @article{HagemannCassidy1994, author = {Hagemann, Hans-J{\"u}rgen and Cassidy, Wiliam D.}, title = {Diamond growth rates and quality: dependence on gas phase cpmposition / William D. Cassidy [...], Hans-Jurgen Hagemann}, series = {Diamond, SiC and nitride wide bandgap semiconductors : symposium held April 4 - 8, 1994, San Francisco, California, U.S.A. / ed.: Calvin H. Carter, Jr. ....}, journal = {Diamond, SiC and nitride wide bandgap semiconductors : symposium held April 4 - 8, 1994, San Francisco, California, U.S.A. / ed.: Calvin H. Carter, Jr. ....}, address = {Pittsburgh, Penn. ,}, isbn = {1-55899-239-1}, pages = {285 -- 291}, year = {1994}, language = {en} } @article{Mischke1995, author = {Mischke, Winfried}, title = {Die Garantie im Kaufrecht}, series = {Betriebs-Berater. 50 (1995), H. 22}, journal = {Betriebs-Berater. 50 (1995), H. 22}, isbn = {0340-7918}, pages = {1093 -- 1096}, year = {1995}, language = {en} } @article{KrauseMoellerMeurer1989, author = {Krause, Gregor and M{\"o}ller, K. and Meurer, D.}, title = {Dielectric phenomena in semicrystalline polymers}, series = {IEEE Transaction on Electrical Insulation. Vol. 24 (1989), H. No. 2}, journal = {IEEE Transaction on Electrical Insulation. Vol. 24 (1989), H. No. 2}, pages = {215 -- 222}, year = {1989}, language = {en} } @article{ChenJostVolkeretal.2017, author = {Chen, Chao and Jost, Peter and Volker, Hanno and Kaminski, Marvin and Wirtssohn, Matti R. and Engelmann, Ulrich M. and Kr{\"u}ger, K. and Schlich, Franziska F. and Schlockermann, Carl and Lobo, Ricardo P.S.M. and Wuttig, Matthias}, title = {Dielectric properties of amorphous phase-change materials}, series = {Physical Review B}, volume = {95}, journal = {Physical Review B}, number = {9}, issn = {2469-9950}, doi = {10.1103/PhysRevB.95.094111}, pages = {Article number 094111}, year = {2017}, language = {en} } @article{KrauseFruth1988, author = {Krause, Gregor and Fruth, B.}, title = {Dielectric Properties of Polyolefins Stressed by High Electrical Fields / Fruth, B. ; Krause, G.}, series = {Plenary lectures and contributions presented at the International Symposium on Polymer Materials : held in San Sebastian (Donostia), Spain, 31 August - 4 September, 1987 / symposium ed. G. M. Guzm{\´a}n ; A. Santamaria}, journal = {Plenary lectures and contributions presented at the International Symposium on Polymer Materials : held in San Sebastian (Donostia), Spain, 31 August - 4 September, 1987 / symposium ed. G. M. Guzm{\´a}n ; A. Santamaria}, publisher = {Huethig \& Wepf}, address = {Basel}, isbn = {3-85739-220-7}, pages = {XIV, 629 S.}, year = {1988}, language = {en} } @article{KrauseFruth1987, author = {Krause, Gregor and Fruth, Bernhard}, title = {Dielectric Properties of Polyolefins Stressed by High Electrical Fields. Fruth, B. ; Krause, G.}, year = {1987}, language = {en} } @article{BiselliNoll1998, author = {Biselli, Manfred and Noll, T.}, title = {Dielectric spectroscopy in the cultivation of suspended and immobilized hybridoma cells / Noll, T.; Biselli, M.}, series = {Journal of Biotechnology. 63 (1998), H. 3}, journal = {Journal of Biotechnology. 63 (1998), H. 3}, isbn = {0168-1656}, pages = {187 -- 198}, year = {1998}, language = {en} } @article{OezsoyluKizildagSchoeningetal.2020, author = {{\"O}zsoylu, Dua and Kizildag, Sefa and Sch{\"o}ning, Michael Josef and Wagner, Torsten}, title = {Differential chemical imaging of extracellular acidification within microfluidic channels using a plasma-functionalized light-addressable potentiometric sensor (LAPS)}, series = {Physics in Medicine}, volume = {10}, journal = {Physics in Medicine}, number = {100030}, publisher = {Elsevier}, address = {Amsterdam}, issn = {2352-4510}, doi = {10.1016/j.phmed.2020.100030}, pages = {8}, year = {2020}, abstract = {Extracellular acidification is a basic indicator for alterations in two vital metabolic pathways: glycolysis and cellular respiration. Measuring these alterations by monitoring extracellular acidification using cell-based biosensors such as LAPS plays an important role in studying these pathways whose disorders are associated with numerous diseases including cancer. However, the surface of the biosensors must be specially tailored to ensure high cell compatibility so that cells can represent more in vivo-like behavior, which is critical to gain more realistic in vitro results from the analyses, e.g., drug discovery experiments. In this work, O2 plasma patterning on the LAPS surface is studied to enhance surface features of the sensor chip, e.g., wettability and biofunctionality. The surface treated with O2 plasma for 30 s exhibits enhanced cytocompatibility for adherent CHO-K1 cells, which promotes cell spreading and proliferation. The plasma-modified LAPS chip is then integrated into a microfluidic system, which provides two identical channels to facilitate differential measurements of the extracellular acidification of CHO-K1 cells. To the best of our knowledge, it is the first time that extracellular acidification within microfluidic channels is quantitatively visualized as differential (bio-)chemical images.}, language = {en} } @article{DantismTakenagaWagneretal.2017, author = {Dantism, Shahriar and Takenaga, Shoko and Wagner, Torsten and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Differential imaging of the metabolism of bacteria and eukaryotic cells based on light-addressable potentiometric sensors}, series = {Electrochimica Acta}, volume = {246}, journal = {Electrochimica Acta}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0013-4686}, doi = {10.1016/j.electacta.2017.05.196}, pages = {234 -- 241}, year = {2017}, abstract = {A light-addressable potentiometric sensor (LAPS) is a field-effect-based potentiometric sensor with an electrolyte/insulator/semiconductor (EIS) structure, which is able to monitor analyte concentrations of (bio-)chemical species in aqueous solutions in a spatially resolved way. Therefore, it is also an appropriate tool to record 2D-chemical images of concentration variations on the sensor surface. In the present work, two differential, LAPS-based measurement principles are introduced to determine the metabolic activity of Escherichia coli (E. coli) K12 and Chinese hamster ovary (CHO) cells as test microorganisms. Hereby, we focus on i) the determination of the extracellular acidification rate (ΔpH/min) after adding glucose solutions to the cell suspensions; and ii) recording the amplitude increase of the photocurrent (Iph) related to the produced acids from E. coli K12 bacteria and CHO cells on the sensor surface by 2D-chemical imaging. For this purpose, 3D-printed multi-chamber structures were developed and mounted on the planar sensor-chip surface to define four independent compartments, enabling differential measurements with varying cell concentrations. The differential concept allows eliminating unwanted drift effects and, with the four-chamber structures, measurements on the different cell concentrations were performed simultaneously, thus reducing also the overall measuring time.}, language = {en} } @article{HeinzelSchaeferMuelleretal.2010, author = {Heinzel, Alexander and Sch{\"a}fer, Ralf and M{\"u}ller, Hans-Wilhelm and Schieffer, Andre and Ingenhag, Ariane and Northoff, Georg and Franz, Matthias and Hautzel, Hubertus}, title = {Differential modulation of valence and arousal in high-alexithymic and low-alexithymic individuals}, series = {Neuroreport}, volume = {21}, journal = {Neuroreport}, number = {15}, publisher = {Lippincott Williams \& Wilkins}, address = {London}, issn = {1473-558X}, doi = {10.1097/WNR.0b013e32833f38e0}, pages = {998 -- 1002}, year = {2010}, abstract = {High-alexithymic individuals are characterized by an impaired ability to identify and communicate emotions whereas low-alexithymic individuals have a wide-ranging ability to deal with emotions. This study examined the hypothesis that valence and arousal modifications of emotional stimuli differentially modulate cortical regions in high-alexithymic and low-alexithymic individuals. To this end, 28 high-alexithymic and 25 low-alexithymic individuals were investigated with event-related fMRI using visual emotional stimuli. We found differential neural activations in the dorsal anterior cingulate, the insula and the amygdala. We suggest that these differences may account for the impaired ability of high-alexithymic individuals to appropriately handle emotional stimuli.}, language = {en} } @article{CapitainRossJonesMoehringetal.2020, author = {Capitain, Charlotte and Ross-Jones, Jesse and M{\"o}hring, Sophie and Tippk{\"o}tter, Nils}, title = {Differential scanning calorimetry for quantification of polymer biodegradability in compost}, series = {International Biodeterioration \& Biodegradation}, volume = {149}, journal = {International Biodeterioration \& Biodegradation}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0964-8305}, doi = {10.1016/j.ibiod.2020.104914}, pages = {In Press, Article number 104914}, year = {2020}, abstract = {The objective of this study is the establishment of a differential scanning calorimetry (DSC) based method for online analysis of the biodegradation of polymers in complex environments. Structural changes during biodegradation, such as an increase in brittleness or crystallinity, can be detected by carefully observing characteristic changes in DSC profiles. Until now, DSC profiles have not been used to draw quantitative conclusions about biodegradation. A new method is presented for quantifying the biodegradation using DSC data, whereby the results were validated using two reference methods. The proposed method is applied to evaluate the biodegradation of three polymeric biomaterials: polyhydroxybutyrate (PHB), cellulose acetate (CA) and Organosolv lignin. The method is suitable for the precise quantification of the biodegradability of PHB. For CA and lignin, conclusions regarding their biodegradation can be drawn with lower resolutions. The proposed method is also able to quantify the biodegradation of blends or composite materials, which differentiates it from commonly used degradation detection methods.}, language = {en} } @article{MiyamotoYoshidaSakaietal.2011, author = {Miyamoto, Ko-ichiro and Yoshida, Midori and Sakai, Taito and Matsuzaka, Atsushi and Wagner, Torsten and Kanoh, Sanoh and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {Differential setup of light-addressable potentiometric sensor with an enzyme reactor in a flow channel}, series = {Japanese Journal of Applied Physics. 50 (2011)}, journal = {Japanese Journal of Applied Physics. 50 (2011)}, publisher = {Japan Society of Applied Physics}, address = {Bristol}, isbn = {0021-4922}, pages = {04DL08-1 -- 04DL08-5}, year = {2011}, language = {en} } @article{JahnkeBaumann1987, author = {Jahnke, J. and Baumann, Marcus}, title = {Differentiation between Phaeocystis pouchetii (Har.) Lagerheim and Phaeocystis globosa Scherffel}, series = {Hydrobiological bulletin}, volume = {Vol. 21}, journal = {Hydrobiological bulletin}, number = {Iss. 2}, issn = {0165-1404 (Print); 1573-5125 (E-Journal)}, pages = {141 -- 147}, year = {1987}, language = {en} } @article{BiselliSchroederHerfurthetal.1997, author = {Biselli, Manfred and Schr{\"o}der, B. and Herfurth, C. and Meißner, P.}, title = {Differentiation of bone marrow cells immobilized on microcarriers in a fluidized bed reactor / Schr{\"o}der, B. ; Herfurth, C. ; Meißner, P. ; Biselli, M. ; Link, H. ; Wandrey, C.}, series = {Animal cell technology : from vaccines to genetic medicine ; [Vilamoura, Portugal, May 1996] / ed. by Manuel J. T. Carrondo}, journal = {Animal cell technology : from vaccines to genetic medicine ; [Vilamoura, Portugal, May 1996] / ed. by Manuel J. T. Carrondo}, publisher = {Kluwer}, address = {Dordrecht}, isbn = {0-7923-4321-2}, pages = {589 -- 593}, year = {1997}, language = {en} } @article{ReichertDeLucchi2001, author = {Reichert, Gerhard and De Lucchi, Michele}, title = {Diffuse Reflexe / Des. Michele De Lucchi, Gerhard Reichert}, series = {MD - Internatioal magazine of design (2001)}, journal = {MD - Internatioal magazine of design (2001)}, isbn = {0343-0642}, pages = {26 -- 27}, year = {2001}, language = {en} } @article{KotterHeeringRiekert1982, author = {Kotter, Michael and Heering, J. and Riekert, L.}, title = {Diffusion and catalytic reaction in zeolite ZSM-5 / J. Heering ; M. Kotter ; L. Riekert}, series = {Chemical engineering science . 37 (1982), H. 4}, journal = {Chemical engineering science . 37 (1982), H. 4}, isbn = {0009-2509}, pages = {581 -- 584}, year = {1982}, language = {en} } @article{PrielmeierSpeedyVardagetal.1989, author = {Prielmeier, Franz and Speedy, R. J. and Vardag, T. and Lang, E. W.}, title = {Diffusion in simple fluids / R. J. Speedy; F. X. Prielmeier; T. Vardag; E. W. Lang; H.-D. L{\"u}demann}, series = {Molecular Physics. 66 (1989), H. 3}, journal = {Molecular Physics. 66 (1989), H. 3}, isbn = {0026-8976}, pages = {577 -- 590}, year = {1989}, language = {en} } @article{PrielmeierLangSpeedyetal.1987, author = {Prielmeier, Franz and Lang, E. W. and Speedy, R. J. and L{\"u}demann, H.-D.}, title = {Diffusion in supercooled water to 300 MPa}, series = {Physical Review Letters. 59 (1987), H. 10}, journal = {Physical Review Letters. 59 (1987), H. 10}, isbn = {0031-9007}, pages = {1128 -- 1131}, year = {1987}, language = {en} } @article{ErmolenkoVlasovKolodnikovetal.2004, author = {Ermolenko, Y.E. and Vlasov, Y.G. and Kolodnikov, V.V. and Shabaldkin, D. A. and Kloock, Joachim P. and Sch{\"o}ning, Michael Josef}, title = {Diffusion of radioactive tracers (204Tl, 110mAg) and ionic conductivity in membrane materials for the chemical sensors}, series = {Advances in nuclear and radiochemistry : extended abstracts of papers presented at the Sixth International Conference on Nuclear and Radiochemistry (NRC-6), 29 August to 3 September 2004, Aachen, Germany ; in cooperation with University of Cologne, GDCh, FECS, OECD-NEA and IAEA / Syed M. Qaim ... (eds.).}, journal = {Advances in nuclear and radiochemistry : extended abstracts of papers presented at the Sixth International Conference on Nuclear and Radiochemistry (NRC-6), 29 August to 3 September 2004, Aachen, Germany ; in cooperation with University of Cologne, GDCh, FECS, OECD-NEA and IAEA / Syed M. Qaim ... (eds.).}, publisher = {Forschungszentrum J{\"u}lich, Zentralbibliothek}, address = {J{\"u}lich}, isbn = {3893363629}, pages = {483 -- 485}, year = {2004}, language = {en} } @article{HartungRamme2000, author = {Hartung, Frank and Ramme, F.}, title = {Digital rights management and watermarking of multimedia content for m-commerce applications / Hartung, F. ; Ramme, F.}, series = {IEEE Communications Magazine. 38 (2000), H. 11}, journal = {IEEE Communications Magazine. 38 (2000), H. 11}, isbn = {0163-6804}, pages = {78 -- 84}, year = {2000}, language = {en} } @article{Benkner1993, author = {Benkner, Thorsten}, title = {Digital TV Receiver with a low IF}, series = {IEEE transactions on consumer electronics : CE ; a publication by the IEEE Consumer Electronics Society. Vol. 39 (1993), H. No. 3}, journal = {IEEE transactions on consumer electronics : CE ; a publication by the IEEE Consumer Electronics Society. Vol. 39 (1993), H. No. 3}, year = {1993}, language = {en} } @article{ArtmannLi1994, author = {Artmann, Gerhard and Li, Anlan}, title = {Dihydroergocryptine maintains erythrocyte fluidity in acidotic and hyperosmolar suspensions modelling hypoxic and ischemic microcirculation. Li, Anlan; Artmann, Gerhard Michael}, series = {Clinical Hemorheology. 15 (1994), H. 2}, journal = {Clinical Hemorheology. 15 (1994), H. 2}, isbn = {0271-5198}, pages = {133 -- 146}, year = {1994}, language = {en} }